Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
PLoS One ; 15(1): e0225397, 2020.
Article in English | MEDLINE | ID: mdl-31910204

ABSTRACT

Wearable electronics capable of recording and transmitting biosignals can provide convenient and pervasive health monitoring. A typical EEG recording produces large amount of data. Conventional compression methods cannot compress date below Nyquist rate, thus resulting in large amount of data even after compression. This needs large storage and hence long transmission time. Compressed sensing has proposed solution to this problem and given a way to compress data below Nyquist rate. In this paper, double temporal sparsity based reconstruction algorithm has been applied for the recovery of compressively sampled EEG data. The results are further improved by modifying the double temporal sparsity based reconstruction algorithm using schattern-p norm along with decorrelation transformation of EEG data before processing. The proposed modified double temporal sparsity based reconstruction algorithm out-perform block sparse bayesian learning and Rackness based compressed sensing algorithms in terms of SNDR and NMSE. Simulation results further show that the proposed algorithm has better convergence rate and less execution time.


Subject(s)
Electroencephalography/methods , Monitoring, Physiologic , Signal Processing, Computer-Assisted , Wearable Electronic Devices/trends , Algorithms , Bayes Theorem , Humans , Image Processing, Computer-Assisted
2.
Int J Biomed Imaging ; 2018: 7803067, 2018.
Article in English | MEDLINE | ID: mdl-29610569

ABSTRACT

Transformed domain sparsity of Magnetic Resonance Imaging (MRI) has recently been used to reduce the acquisition time in conjunction with compressed sensing (CS) theory. Respiratory motion during MR scan results in strong blurring and ghosting artifacts in recovered MR images. To improve the quality of the recovered images, motion needs to be estimated and corrected. In this article, a two-step approach is proposed for the recovery of cardiac MR images in the presence of free breathing motion. In the first step, compressively sampled MR images are recovered by solving an optimization problem using gradient descent algorithm. The L1-norm based regularizer, used in optimization problem, is approximated by a hyperbolic tangent function. In the second step, a block matching algorithm, known as Adaptive Rood Pattern Search (ARPS), is exploited to estimate and correct respiratory motion among the recovered images. The framework is tested for free breathing simulated and in vivo 2D cardiac cine MRI data. Simulation results show improved structural similarity index (SSIM), peak signal-to-noise ratio (PSNR), and mean square error (MSE) with different acceleration factors for the proposed method. Experimental results also provide a comparison between k-t FOCUSS with MEMC and the proposed method.

3.
Magn Reson Imaging ; 36: 159-166, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27746392

ABSTRACT

Respiratory motion during Magnetic Resonance (MR) acquisition causes strong blurring artifacts in the reconstructed images. These artifacts become more pronounced when used with the fast imaging reconstruction techniques like compressed sensing (CS). Recently, an MR reconstruction technique has been done with the help of compressed sensing (CS), to provide good quality sparse images from the highly under-sampled k-space data. In order to maximize the benefits of CS, it is obvious to use CS with the motion corrected samples. In this paper, we propose a novel CS based motion corrected image reconstruction technique. First, k-space data have been assigned to different respiratory state with the help of frequency domain phase correlation method. Then, multiple sparsity constraints has been used to provide good quality reconstructed cardiac cine images with the highly under-sampled k-space data. The proposed method exploits the multiple sparsity constraints, in combination with demon based registration technique and a novel reconstruction technique to provide the final motion free images. The proposed method is very simple to implement in clinical settings as compared to existing motion corrected methods. The performance of the proposed method is examined using simulated data and clinical data. Results show that this method performs better than the reconstruction of CS based method of cardiac cine images. Different acceleration rates have been used to show the performance of the proposed method.


Subject(s)
Heart/diagnostic imaging , Heart/physiology , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Algorithms , Artifacts , Computer Simulation , Humans , Motion
SELECTION OF CITATIONS
SEARCH DETAIL
...