2.
EJIFCC ; 29(2): 129-137, 2018 Jul.
Article in English | MEDLINE | ID: mdl-30050396

ABSTRACT

The development and evaluation of novel biomarkers and testing strategies requires a close examination of existing clinical pathways, including mapping of current pathways and identifying areas of unmet need. This approach enables early recognition of analytical and clinical performance criteria to guide evaluation studies, in a cyclical and iterative manner, all the time keeping the clinical pathway and patient health outcomes as the key drivers in the process. The Test Evaluation Working Group of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM TE-WG) https://www.eflm.eu/site/page/a/1158 has published a conceptual framework of the test evaluation cycle which is driven by the clinical pathway, inherent to which is the test purpose and role within the pathway that are defined by clinical need. To supplement this framework, the EFLM TE-WG has also published an interactive checklist for identifying unmet clinical needs for new biomarkers; a practical tool that laboratories, clinicians, researchers and industry can equally use in a consistent manner when new tests are developed and before they are released to the market. It is hoped that these practical tools will provide consistent and appropriate terminology in this diverse field and offer a platform that facilitates greater consultation and collaboration between all stakeholders. The checklist should assist the work of all colleagues involved in the discovery of novel biomarkers and implementation of new medical tests. The tool is aligned with the IOM recommendations and the FDA and CE regulating body's requirements.

4.
Clin Chem Lab Med ; 40(5): 529-36, 2002 May.
Article in English | MEDLINE | ID: mdl-12113300

ABSTRACT

Soluble transferrin receptor (sTfR) is reported to be a reliable marker for the diagnosis of iron deficiency, especially when iron metabolism is influenced by inflammatory disorders such as infection, chronic inflammation and cancer-related anemia. In the present multicenter study the analytical performance of a recently introduced, latex-enhanced immunoturbidimetric assay for the determination of soluble transferrin receptor (Tina quant [a] sTfR, Roche Diagnostics) on different fully mechanized analyzers such as Hitachi 917 and 911, and Cobas Integra 400 and 700 was evaluated. Within-run and between-run imprecision showed good results (CV<5% and <7%, respectively). The assay was found to be linear over a wide measuring range (0.4-35 mg/l). Endogenous substances did not interfere with the test results. Comparison of serum sTfR concentrations with those of heparinized plasma revealed good correlation (r>0.976). Method comparison with an existing fully mechanized method as well as with ELISA tests for sTfR showed very good correlation (r>0.987). Because of the lack of international standardization the results differed from each other up to 2.5-fold. The 95% of serum levels in healthy individuals ranged from 1.9 to 4.4 mg/l (n=427). However, the reference ranges should be reported in a sex-dependent manner, as 2.2-5.0 mg/l for men (n=211) and as 1.9-4.4 mg/l for premenopausal (n=216) and postmenopausal (n=45) women. The Tina quant [a] sTfR assay enables the precise, accurate, rapid and convenient determination of sTfR concentrations for routine clinical chemistry purposes.


Subject(s)
Nephelometry and Turbidimetry/methods , Receptors, Transferrin/blood , Adolescent , Adult , Aged , Anemia, Iron-Deficiency/diagnosis , Female , Hematologic Tests , Humans , Latex Fixation Tests/methods , Latex Fixation Tests/standards , Male , Middle Aged , Nephelometry and Turbidimetry/standards , Reference Values , Reproducibility of Results , Sex Factors , Solubility
SELECTION OF CITATIONS
SEARCH DETAIL
...