1.
Magn Reson Med ; 85(3): 1481-1492, 2021 03.
Article in English | MEDLINE | ID: mdl-33009877

ABSTRACT

PURPOSE: Evolutionary medicine aims to study disease development from a long-term perspective, and through the analysis of mummified tissue, timescales of several thousand years are unlocked. Due to the status of mummies as ancient relics, noninvasive techniques are preferable, and, currently, CT imaging is the most widespread method. However, CT images lack soft-tissue contrast, making complementary MRI data desirable. Unfortunately, the dehydrated nature and short T2 times of mummified tissues render them practically invisible to standard MRI techniques. Specialized short-T2 approaches have therefore been used, but currently suffer severe resolution limitations. The purpose of the present study is to improve resolution in MRI of mummified tissues. METHODS: The zero-TE-based hybrid filling technique, together with a high-performance magnetic field gradient, was used to image three ancient Egyptian mummified human body parts: a hand, a foot, and a head. A similar pairing has already been shown to increase resolution and image quality in MRI of short-T2 tissues. RESULTS: MRI images of yet unparalleled image quality were obtained for all samples, reaching isotropic resolutions of 0.6 mm and SNR values above 100. The same general features as present in CT images were depicted but with different contrast, particularly for regions containing embalming substances. CONCLUSION: Mummy MRI is a potentially valuable tool for (paleo)pathological studies, as well as for investigations into ancient mummification processes. The results presented here show sufficient improvement in the depiction of mummified tissues to clear new paths for the exploration of this field.


Subject(s)
Mummies , Egypt , Hand/anatomy & histology , Head , Humans , Magnetic Resonance Imaging , Mummies/diagnostic imaging
2.
Neuroimage ; 217: 116888, 2020 08 15.
Article in English | MEDLINE | ID: mdl-32360688

ABSTRACT

Myelin plays a key role in the function of the central nervous system and is involved in many neurodegenerative diseases. Hence, depiction of myelin is desired for both research and diagnosis. However, MRI of the lipid bilayer constituting the myelin membrane is hampered by extremely rapid signal decay and cannot be accomplished with conventional sequences. Dedicated short-T2 techniques have therefore been employed, yet with extended sequence timings not well matched to the rapid transverse relaxation in the bilayer, which leads to signal loss and blurring. In the present work, capture and encoding of the ultra-short-T2 signals in the myelin bilayer is considerably improved by employing advanced short-T2 methodology and hardware, in particular a high-performance human-sized gradient insert. The approach is applied to tissue samples excised from porcine brain and in vivo in a human volunteer. It is found that the rapidly decaying non-aqueous components in the brain can indeed be depicted with MRI at useful resolution. As a considerable fraction of these signals is related to the myelin bilayer, the presented approach has strong potential to contribute to myelin research and diagnosis.


Subject(s)
Lipid Bilayers , Magnetic Resonance Imaging/methods , Myelin Sheath , Algorithms , Animals , Body Water , Brain/diagnostic imaging , Computer Simulation , Humans , Image Processing, Computer-Assisted , Magnetic Resonance Imaging/instrumentation , Phantoms, Imaging , Swine
3.
Magn Reson Med ; 83(2): 412-426, 2020 02.
Article in English | MEDLINE | ID: mdl-31502718

ABSTRACT

PURPOSE: To perform direct, selective MRI of short-T2 tissues using zero echo time (ZTE) imaging with weighted echo subtraction (WSUB). METHODS: Radial imaging was performed at 7T, acquiring both ZTE and gradient echo (GRE) signals created by bipolar gradients. Long-T2 suppression was achieved by weighted subtraction of ZTE and GRE images. Special attention was given to imperfections of gradient dynamics, to which radial GRE imaging is particularly susceptible. To compensate for gradient errors, matching of gradient history was combined with data correction based on trajectory measurement. The proposed approach was first validated in phantom experiments and then demonstrated in musculoskeletal (MSK) imaging. RESULTS: Trajectory analysis and phantom imaging demonstrated that gradient imperfections were successfully addressed. Gradient history matching enabled consistency between antiparallel projections as required for deriving zeroth-order eddy current dynamics. Trajectory measurement provided individual echo times per projection that showed considerable variation between gradient directions. In in vivo imaging of knee, ankle, and tibia, the proposed approach enabled high-resolution 3D depiction of bone, tendons, and ligaments. Distinct contrast of these structures indicates excellent selectivity of long-T2 suppression. Clarity of depiction also confirmed sufficient SNR of short-T2 tissues, achieved by high baseline sensitivity at 7T combined with high SNR efficiency of ZTE acquisition. CONCLUSION: Weighted subtraction of ZTE and GRE data reconciles robust long-T2 suppression with fastest k-space coverage and high SNR efficiency. This approach enables high-resolution imaging with excellent selectivity to short-T2 tissues, which are of major interest in MSK and neuroimaging applications.


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging , Algorithms , Bone and Bones/diagnostic imaging , Calibration , Humans , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional , Knee/diagnostic imaging , Ligaments/diagnostic imaging , Male , Muscle, Skeletal/diagnostic imaging , Phantoms, Imaging , Signal-To-Noise Ratio , Tendons/diagnostic imaging , Tibia/diagnostic imaging
4.
Magn Reson Med ; 79(6): 3256-3266, 2018 06.
Article in English | MEDLINE | ID: mdl-28983969

ABSTRACT

PURPOSE: The goal of this study was to devise a gradient system for MRI in humans that reconciles cutting-edge gradient strength with rapid switching and brings up the duty cycle to 100% at full continuous amplitude. Aiming to advance neuroimaging and short-T2 techniques, the hardware design focused on the head and the extremities as target anatomies. METHODS: A boundary element method with minimization of power dissipation and stored magnetic energy was used to design anatomy-targeted gradient coils with maximally relaxed geometry constraints. The design relies on hollow conductors for high-performance cooling and split coils to enable dual-mode gradient amplifier operation. With this approach, strength and slew rate specifications of either 100 mT/m with 1200 mT/m/ms or 200 mT/m with 600 mT/m/ms were reached at 100% duty cycle, assuming a standard gradient amplifier and cooling unit. RESULTS: After manufacturing, the specified values for maximum gradient strength, maximum switching rate, and field geometry were verified experimentally. In temperature measurements, maximum local values of 63°C were observed, confirming that the device can be operated continuously at full amplitude. Testing for peripheral nerve stimulation showed nearly unrestricted applicability in humans at full gradient performance. In measurements of acoustic noise, a maximum average sound pressure level of 132 dB(A) was determined. In vivo capability was demonstrated by head and knee imaging. Full gradient performance was employed with echo planar and zero echo time readouts. CONCLUSION: Combining extreme gradient strength and switching speed without duty cycle limitations, the described system offers unprecedented options for rapid and short-T2 imaging. Magn Reson Med 79:3256-3266, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Brain/diagnostic imaging , Equipment Design , Humans , Knee/diagnostic imaging , Male , Nonlinear Dynamics , Phantoms, Imaging , Temperature