Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Clin Neurophysiol Pract ; 7: 183-200, 2022.
Article in English | MEDLINE | ID: mdl-35865124

ABSTRACT

Objective: To determine the prevalence and characteristics of normal variants in EEG recordings in a large cohort, and provide readers with typical examples of all normal variants for educational purposes. Methods: Using the SCORE EEG system (Standardized Computer-Based Organized Reporting of EEG), we prospectively extracted EEG features in consecutive patients. In this dataset, we analyzed 3050 recordings from 2319 patients (mean age 38.5 years; range: 1-89 years). Results: The distribution of the normal variants was as follows: sharp transients 19.21% (including wicket spikes), rhythmic temporal theta of drowsiness 6.03%, temporal slowing of the old 2.89%, slow fused transients 2.59%, 14-and 6-Hz bursts 1.83%, breach rhythm 1.25%, small sharp spikes 1.05%, 6-Hz spike and slow wave 0.69% and SREDA 0.03%. Conclusions: The most prevalent normal variants are the sharp transients, which must not be over-read as epileptiform discharges. Significance: EEG readers must be familiar with the normal variants to avoid misdiagnosis and misclassification of patients referred to clinical EEG recordings.

2.
Clin Neurophysiol Pract ; 7: 135-138, 2022.
Article in English | MEDLINE | ID: mdl-35620351

ABSTRACT

Objective: To determine the feasibility and accuracy of a handheld optical scanner to measure the three-dimensional (3D) EEG electrode coordinates in a high-density array of 256 electrodes. Methods: We compared the optical scanning with a previously validated method, based on photogrammetry. Electrode coordinates were co-registered with the MRI of the patients, and mean distance error relative to the three-dimensional MRI reconstruction was determined for each patient. We included 60 patients: 30 were measured using the photogrammetry method, and 30 age and gender matched patients were measured with the optical scanner. Results: Using the optical scanner, the mean distance error was 1.78 mm (95% confidence interval: 1.59-1.98 mm) which was significantly lower (p < 0.001) compared with the photogrammetry method (mean distance error: 2.43 mm; 95% confidence interval: 2.28-2.57 mm). The real-time scanning took 5-10 min per patient. Conclusions: The handheld optical scanner is more accurate and feasible, compared to the photogrammetry method. Significance: Measuring EEG electrode positions in high-density array, using the optical scanner is suitable for clinical implementation in EEG source imaging for presurgical evaluation.

SELECTION OF CITATIONS
SEARCH DETAIL
...