Artif Intell Med ; 132: 102381, 2022 10.
Article in English | MEDLINE | ID: mdl-36207087

ABSTRACT

BACKGROUND: The application of artificial intelligence to interpret the electrocardiogram (ECG) has predominantly included the use of knowledge engineered rule-based algorithms which have become widely used today in clinical practice. However, over recent decades, there has been a steady increase in the number of research studies that are using machine learning (ML) to read or interrogate ECG data. OBJECTIVE: The aim of this study is to review the use of ML with ECG data using a time series approach. METHODS: Papers that address the subject of ML and the ECG were identified by systematically searching databases that archive papers from January 1995 to October 2019. Time series analysis was used to study the changing popularity of the different types of ML algorithms that have been used with ECG data over the past two decades. Finally, a meta-analysis of how various ML techniques performed for various diagnostic classifications was also undertaken. RESULTS: A total of 757 papers was identified. Based on results, the use of ML with ECG data started to increase sharply (p < 0.001) from 2012. Healthcare applications, especially in heart abnormality classification, were the most common application of ML when using ECG data (p < 0.001). However, many new emerging applications include using ML and the ECG for biometrics and driver drowsiness. The support vector machine was the technique of choice for a decade. However, since 2018, deep learning has been trending upwards and is likely to be the leading technique in the coming few years. Despite the accuracy paradox, accuracy was the most frequently used metric in the studies reviewed, followed by sensitivity, specificity, F1 score and then AUC. CONCLUSION: Applying ML using ECG data has shown promise. Data scientists and physicians should collaborate to ensure that clinical knowledge is being applied appropriately and is informing the design of ML algorithms. Data scientists also need to consider knowledge guided feature engineering and the explicability of the ML algorithm as well as being transparent in the algorithm's performance to appropriately calibrate human-AI trust. Future work is required to enhance ML performance in ECG classification.


Subject(s)
Artificial Intelligence , Benchmarking , Algorithms , Electrocardiography , Humans , Machine Learning , Time Factors
2.
Article in English | MEDLINE | ID: mdl-37786732

ABSTRACT

Electrocardiographic Imaging (ECGI) is a promising tool to non-invasively map the electrical activity of the heart using body surface potentials (BSPs) and the patient specific anatomical data. One of the first steps of ECGI is the segmentation of the heart and torso geometries. In the clinical practice, the segmentation procedure is not fully-automated yet and is in consequence operator-dependent. We expect that the inter-operator variation in cardiac segmentation would influence the ECGI solution. This effect remains however non quantified. In the present work, we study the effect of segmentation variability on the ECGI estimation of the cardiac activity with 262 shape models generated from fifteen different segmentations. Therefore, we designed two test cases: with and without shape model uncertainty. Moreover, we used four cases for ectopic ventricular excitation and compared the ECGI results in terms of reconstructed activation times and excitation origins. The preliminary results indicate that a small variation of the activation maps can be observed with a model uncertainty but no significant effect on the source localization is observed.

3.
Article in English | MEDLINE | ID: mdl-37799667

ABSTRACT

Segmentation of patient-specific anatomical models is one of the first steps in Electrocardiographic imaging (ECGI). However, the effect of segmentation variability on ECGI remains unexplored. In this study, we assess the effect of heart segmentation variability on ECG simulation. We generated a statistical shape model from segmentations of the same patient and generated 262 cardiac geometries to run in an ECG forward computation of body surface potentials (BSPs) using an equivalent dipole layer cardiac source model and 5 ventricular stimulation protocols. Variability between simulated BSPs for all models and protocols was assessed using Pearson's correlation coefficient (CC). Compared to the BSPs of the mean cardiac shape model, the lowest variability (average CC = 0.98 ± 0.03) was found for apical pacing whereas the highest variability (average CC = 0.90 ± 0.23) was found for right ventricular free wall pacing. Furthermore, low amplitude BSPs show a larger variation in QRS morphology compared to high amplitude signals. The results indicate that the uncertainty in cardiac shape has a significant impact on ECGI.

4.
Comput Biol Med ; 136: 104666, 2021 09.
Article in English | MEDLINE | ID: mdl-34315032

ABSTRACT

Electrocardiographic imaging is an imaging modality that has been introduced recently to help in visualizing the electrical activity of the heart and consequently guide the ablation therapy for ventricular arrhythmias. One of the main challenges of this modality is that the electrocardiographic signals recorded at the torso surface are contaminated with noise from different sources. Low amplitude leads are more affected by noise due to their low peak-to-peak amplitude. In this paper, we have studied 6 datasets from two torso tank experiments (Bordeaux and Utah experiments) to investigate the impact of removing or interpolating these low amplitude leads on the inverse reconstruction of cardiac electrical activity. Body surface potential maps used were calculated by using the full set of recorded leads, removing 1, 6, 11, 16, or 21 low amplitude leads, or interpolating 1, 6, 11, 16, or 21 low amplitude leads using one of the three interpolation methods - Laplacian interpolation, hybrid interpolation, or the inverse-forward interpolation. The epicardial potential maps and activation time maps were computed from these body surface potential maps and compared with those recorded directly from the heart surface in the torso tank experiments. There was no significant change in the potential maps and activation time maps after the removal of up to 11 low amplitude leads. Laplacian interpolation and hybrid interpolation improved the inverse reconstruction in some datasets and worsened it in the rest. The inverse forward interpolation of low amplitude leads improved it in two out of 6 datasets and at least remained the same in the other datasets. It was noticed that after doing the inverse-forward interpolation, the selected lambda value was closer to the optimum lambda value that gives the inverse solution best correlated with the recorded one.

5.
JMIR Med Inform ; 9(4): e25347, 2021 Apr 16.
Article in English | MEDLINE | ID: mdl-33861205

ABSTRACT

BACKGROUND: A 12-lead electrocardiogram (ECG) is the most commonly used method to diagnose patients with cardiovascular diseases. However, there are a number of possible misinterpretations of the ECG that can be caused by several different factors, such as the misplacement of chest electrodes. OBJECTIVE: The aim of this study is to build advanced algorithms to detect precordial (chest) electrode misplacement. METHODS: In this study, we used traditional machine learning (ML) and deep learning (DL) to autodetect the misplacement of electrodes V1 and V2 using features from the resultant ECG. The algorithms were trained using data extracted from high-resolution body surface potential maps of patients who were diagnosed with myocardial infarction, diagnosed with left ventricular hypertrophy, or a normal ECG. RESULTS: DL achieved the highest accuracy in this study for detecting V1 and V2 electrode misplacement, with an accuracy of 93.0% (95% CI 91.46-94.53) for misplacement in the second intercostal space. The performance of DL in the second intercostal space was benchmarked with physicians (n=11 and age 47.3 years, SD 15.5) who were experienced in reading ECGs (mean number of ECGs read in the past year 436.54, SD 397.9). Physicians were poor at recognizing chest electrode misplacement on the ECG and achieved a mean accuracy of 60% (95% CI 56.09-63.90), which was significantly poorer than that of DL (P<.001). CONCLUSIONS: DL provides the best performance for detecting chest electrode misplacement when compared with the ability of experienced physicians. DL and ML could be used to help flag ECGs that have been incorrectly recorded and flag that the data may be flawed, which could reduce the number of erroneous diagnoses.

6.
J Electrocardiol ; 62: 116-123, 2020.
Article in English | MEDLINE | ID: mdl-32866909

ABSTRACT

INTRODUCTION: Electrode misplacement and interchange errors are known problems when recording the 12­lead electrocardiogram (ECG). Automatic detection of these errors could play an important role for improving clinical decision making and outcomes in cardiac care. The objectives of this systematic review and meta-analysis is to 1) study the impact of electrode misplacement on ECG signals and ECG interpretation, 2) to determine the most challenging electrode misplacements to detect using machine learning (ML), 3) to analyse the ML performance of algorithms that detect electrode misplacement or interchange according to sensitivity and specificity and 4) to identify the most commonly used ML technique for detecting electrode misplacement/interchange. This review analysed the current literature regarding electrode misplacement/interchange recognition accuracy using machine learning techniques. METHOD: A search of three online databases including IEEE, PubMed and ScienceDirect identified 228 articles, while 3 articles were included from additional sources from co-authors. According to the eligibility criteria, 14 articles were selected. The selected articles were considered for qualitative analysis and meta-analysis. RESULTS: The articles showed the effect of lead interchange on ECG morphology and as a consequence on patient diagnoses. Statistical analysis of the included articles found that machine learning performance is high in detecting electrode misplacement/interchange except left arm/left leg interchange. CONCLUSION: This review emphasises the importance of detecting electrode misplacement detection in ECG diagnosis and the effects on decision making. Machine learning shows promise in detecting lead misplacement/interchange and highlights an opportunity for developing and operationalising deep learning algorithms such as convolutional neural network (CNN) to detect electrode misplacement/interchange.


Subject(s)
Electrocardiography , Machine Learning , Algorithms , Electrodes , Humans , Neural Networks, Computer
7.
J Electrocardiol ; 57: 39-43, 2019.
Article in English | MEDLINE | ID: mdl-31476727

ABSTRACT

BACKGROUND: Electrocardiogram (ECG) lead misplacement can adversely affect ECG diagnosis and subsequent clinical decisions. V1 and V2 are commonly placed superior of their correct position. The aim of the current study was to use machine learning approaches to detect V1 and V2 lead misplacement to enhance ECG data quality. METHOD: ECGs for 453 patients, (normal n = 151, Left Ventricular Hypertrophy (LVH) n = 151, Myocardial Infarction n = 151) were extracted from body surface potential maps. These were used to extract both the correct and incorrectly placed V1 and V2 leads. The prevalence for correct and incorrect leads were 50%. Sixteen features were extracted in three different domains: time-based, statistical and time-frequency features using a wavelet transform. A hybrid feature selection approach was applied to select an optimal set of features. To ensure optimal model selection, five classifiers were used and compared. The aforementioned feature selection approach and classifiers were applied for V1 and V2 misplacement in three different positions: first, second and third intercostal spaces (ICS). RESULTS: The accuracy for V1 misplacement detection was 93.9%, 89.3%, 72.8% in the first, second and third ICS respectively. In V2, the accuracy was 93.6%, 86.6% and 68.1% in the first, second and third ICS respectively. There is a noticeable decline in accuracy when detecting misplacement in the third ICS which is expected.


Subject(s)
Electrocardiography , Myocardial Infarction , Electrodes , Humans , Machine Learning , Thorax