Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Pacing Clin Electrophysiol ; 37(11): 1510-9, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25053272

ABSTRACT

BACKGROUND: The aim of the Endocardial T-Wave Alternans Study was to prospectively assess the presence of T-wave alternans (TWA) or beat-to-beat repolarization changes on implantable cardioverter-defibrillator (ICD)-stored electrograms (EGMs) immediately preceding the onset of spontaneous ventricular tachycardia (VT) or fibrillation (VF). METHODS: Thirty-seven VT/VF episodes were compared to 116 baseline reference EGMs from the same 57 patients. A Bayesian model was used to estimate the T-wave waveform in each cardiac beat and a set of 10 parameters was selected to segment each detected T wave. Beat-by-beat differences in each T-wave parameter were computed using the absolute value of the difference between each beat and the following one. Fisher criterion was used for determining the most discriminant T-wave parameters, then top-M ranked parameters yielding a normalized cumulative Fisher score > 95% were selected, and analysis was applied on these selected parameters. Simulated TWA EGMs were used to validate the algorithm. RESULTS: In the simulation study, TWA was detectable even in the case of the smallest simulated alternans of 25 µV. In 13 of the 37 episodes (35%) occurring in nine of 16 patients, significant larger beat-to-beat variations before arrhythmia onset were detected compared to their respective references (median one positive episode per patient). Parameters including the T-wave apex amplitude seem the more discriminant parameters. CONCLUSIONS: Detection of beat-by-beat repolarization variations in ICD-stored EGMs is feasible in a significant subset of cases and may be used for predicting the onset of ventricular arrhythmias.


Subject(s)
Defibrillators, Implantable , Electrophysiologic Techniques, Cardiac , Tachycardia, Ventricular/physiopathology , Tachycardia, Ventricular/therapy , Adult , Aged , Aged, 80 and over , Arrhythmias, Cardiac , Brugada Syndrome , Cardiac Conduction System Disease , Female , Heart Conduction System/abnormalities , Humans , Male , Middle Aged , Prospective Studies
2.
Cardiology ; 110(1): 17-28, 2008.
Article in English | MEDLINE | ID: mdl-17934265

ABSTRACT

OBJECTIVES: Complete bidirectional cavo-tricuspid isthmus (CTI) block is mandatory for radio-frequency (RF) ablation of typical atrial flutter (AF). CTI block can be assessed by a simplified method using two catheters and the technique of differential pacing, but long-term results in large series are poorly known. METHODS: CTI RF ablation was performed in 255 consecutive patients with typical AF, using one quadripolar catheter, and the ablation catheter, in association with the technique of differential pacing. RESULTS: Procedural success, as defined by documentation of complete bidirectional CTI block using limited activation mapping, positive differential pacing together with termination of ongoing AF, was achieved in 80% of patients. AF recurred in 37 patients (14%) over a mean follow-up period of 15 +/- 9 months. Two hundred and forty-one patients (94%) were finally cured, with 1.1 procedures/patient. The recurrence rate was related to the achievement of complete CTI bidirectional block (12% vs. 29%, p = 0.01). CONCLUSIONS: Long-term results of CTI ablation, employing a simplified method using the differential pacing technique, are similar to those for the standard methods using multipolar catheters. Therefore, this technique compares favorably to other established methods for such common RF procedures, especially due to its lower cost.


Subject(s)
Atrial Flutter/diagnosis , Atrial Flutter/surgery , Catheter Ablation/methods , Electrocardiography , Heart Block/diagnosis , Adolescent , Adult , Aged , Aged, 80 and over , Atrial Flutter/mortality , Female , Follow-Up Studies , Heart Conduction System , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Predictive Value of Tests , Probability , Prospective Studies , Recurrence , Risk Assessment , Severity of Illness Index , Statistics, Nonparametric , Survival Rate , Time Factors , Treatment Outcome , Tricuspid Valve
SELECTION OF CITATIONS
SEARCH DETAIL
...