Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
J Magn Reson Imaging ; 2024 Jul 04.
Article in English | MEDLINE | ID: mdl-38963154

ABSTRACT

BACKGROUND: Lower back pain affects 75%-85% of people at some point in their lives. The detection of biochemical changes with sodium (23Na) MRI has potential to enable an earlier and more accurate diagnosis. PURPOSE: To measure 23Na relaxation times and apparent tissue sodium concentration (aTSC) in ex-vivo intervertebral discs (IVDs), and to investigate the relationship between aTSC and histological Thompson grade. STUDY TYPE: Ex-vivo. SPECIMEN: Thirty IVDs from the lumbar spines of 11 human body donors (4 female, 7 male, mean age 86 ± 8 years). FIELD STRENGTH/SEQUENCE: 3 T; density-adapted 3D radial sequence (DA-3D-RAD). ASSESSMENT: IVD 23Na longitudinal (T1), short and long transverse (T2s* and T2l*) relaxation times and the proportion of the short transverse relaxation (ps) were calculated for one IVD per spine sample (11 IVDs). Furthermore, aTSCs were calculated for all IVDs. The degradation of the IVDs was assessed via histological Thompson grading. STATISTICAL TESTS: A Kendall Tau correlation (τ) test was performed between the aTSCs and the Thompson grades. The significance level was set to P < 0.05. RESULTS: Mean 23Na relaxation parameters of a subset of 11 IVDs were T1 = 9.8 ± 1.3 msec, T2s* = 0.7 ± 0.1 msec, T2l* = 7.3 ± 1.1 msec, and ps = 32.7 ± 4.0%. A total of 30 IVDs were examined, of which 3 had Thompson grade 1, 4 had grade 2, 5 had grade 3, 5 had grade 4, and 13 had grade 5. The aTSC decreased with increasing degradation, being 274.6 ± 18.9 mM for Thompson grade 1 and 190.5 ± 29.5 mM for Thompson grade 5. The correlation between whole IVD aTSC and Thompson grade was significant and strongly negative (τ = -0.56). DATA CONCLUSION: This study showed a significant correlation between aTSC and degenerative IVD changes. Consequently, aTSC has potential to be useful as an indicator of degenerative spinal changes. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY: Stage 1.

2.
Diagnostics (Basel) ; 14(10)2024 May 08.
Article in English | MEDLINE | ID: mdl-38786276

ABSTRACT

Quantitative MRI techniques such as T2 and T1ρ mapping are beneficial in evaluating knee joint pathologies; however, long acquisition times limit their clinical adoption. MIXTURE (Multi-Interleaved X-prepared Turbo Spin-Echo with IntUitive RElaxometry) provides a versatile turbo spin-echo (TSE) platform for simultaneous morphologic and quantitative joint imaging. Two MIXTURE sequences were designed along clinical requirements: "MIX1", combining proton density (PD)-weighted fat-saturated (FS) images and T2 mapping (acquisition time: 4:59 min), and "MIX2", combining T1-weighted images and T1ρ mapping (6:38 min). MIXTURE sequences and their reference 2D and 3D TSE counterparts were acquired from ten human cadaveric knee joints at 3.0 T. Contrast, contrast-to-noise ratios, and coefficients of variation were comparatively evaluated using parametric tests. Clinical radiologists (n = 3) assessed diagnostic quality as a function of sequence and anatomic structure using five-point Likert scales and ordinal regression, with a significance level of α = 0.01. MIX1 and MIX2 had at least equal diagnostic quality compared to reference sequences of the same image weighting. Contrast, contrast-to-noise ratios, and coefficients of variation were largely similar for the PD-weighted FS and T1-weighted images. In clinically feasible scan times, MIXTURE sequences yield morphologic, TSE-based images of diagnostic quality and quantitative parameter maps with additional insights on soft tissue composition and ultrastructure.

3.
Curr Med Imaging ; 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38415484

ABSTRACT

Background: Despite the availability of vaccines, there is an increasing number of SARS-CoV-2-breakthrough-infections. OBJECTIVE: The aim of this study was to determine whether there is a radiological difference in lung parenchymal involvement between infected vaccinated and unvaccinated patients. Additionally, we aimed to investigate whether vaccination has an impact on the course of illness and the need for intensive care. METHODS: This study includes all patients undergoing chest computed tomography (CT) or x-ray imaging in case of a proven SARS-CoV-2 infection between September and November 2021. Anonymized CT and x-ray images were reviewed retrospectively and in consensus by two radiologists, applying an internal severity score scheme for CT and x-ray as well as CARE and BRIXIA scores for x-ray. Radiological findings were compared to vaccination status, comorbidities, inpatient course of the patient's illness and the subjective onset of symptoms. RESULTS: In total, 38 patients with acute SARS-CoV-2 infection underwent a CT scan, and 168 patients underwent an x-ray examination during the study period. Of these, 32% were vaccinated in the CT group, and 45% in the x-ray group. For the latter, vaccinated patients exhibited significantly more comorbidities (cardiovascular (p=0.002), haemato-oncological diseases (p=0.016), immunosuppression (p=0.004)), and a higher age (p<0.001). Vaccinated groups showed significantly lower extent of lung involvement (severity scores in CT cohort and x-ray cohort both p≤0.020; ARDS 42% in unvaccinated CT cohort vs. 8% in vaccinated CT cohort). Furthermore, vaccinated patients in the CT cohort had significantly less need for intensive care treatment (p=0.040). CONCLUSION: Our data suggest that vaccination, in the case of breakthrough infection, favours a milder course of illness concerning lung parenchymal involvement and the need for intensive care, despite negative predictors, such as immunosuppression or other pre-existing conditions.

.

4.
Skeletal Radiol ; 53(4): 791-800, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37819279

ABSTRACT

OBJECTIVE: Clinical-standard MRI is the imaging modality of choice for the wrist, yet limited to static evaluation, thereby potentially missing dynamic instability patterns. We aimed to investigate the clinical benefit of (dynamic) real-time MRI, complemented by automatic analysis, in patients with complete or partial scapholunate ligament (SLL) tears. MATERIAL AND METHODS: Both wrists of ten patients with unilateral SLL tears (six partial, four complete tears) as diagnosed by clinical-standard MRI were imaged during continuous active radioulnar motion using a 1.5-T MRI scanner in combination with a custom-made motion device. Following automatic segmentation of the wrist, the scapholunate and lunotriquetral joint widths were analyzed across the entire range of motion (ROM). Mixed-effects model analysis of variance (ANOVA) followed by Tukey's posthoc test and two-way ANOVA were used for statistical analysis. RESULTS: With the increasing extent of SLL tear, the scapholunate joint widths in injured wrists were significantly larger over the entire ROM compared to those of the contralateral healthy wrists (p<0.001). Differences between partial and complete tears were most pronounced at 5°-15° ulnar abduction (p<0.001). Motion patterns and trajectories were altered. Complete SLL deficiency resulted in complex alterations of the lunotriquetral joint widths. CONCLUSION: Real-time MRI may improve the functional diagnosis of SLL insufficiency and aid therapeutic decision-making by revealing dynamic forms of dissociative instability within the proximal carpus. Static MRI best differentiates SLL-injured wrists at 5°-15° of ulnar abduction.


Subject(s)
Carpal Joints , Joint Instability , Wrist Injuries , Humans , Wrist Joint/diagnostic imaging , Magnetic Resonance Imaging/methods , Carpal Joints/diagnostic imaging , Ligaments, Articular/diagnostic imaging , Magnetic Resonance Spectroscopy , Joint Instability/diagnostic imaging , Wrist Injuries/diagnostic imaging
5.
Quant Imaging Med Surg ; 13(11): 7467-7483, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37969627

ABSTRACT

Background: The field of orthopedics seeks effective, safer methods for evaluating articular cartilage regeneration. Despite various treatment innovations, non-invasive, contrast-free full quantitative assessments of hyaline articular cartilage's regenerative potential using compositional magnetic resonance (MR) sequences remain challenging. In this context, our aim was to investigate the effectiveness of different MR sequences for quantitative assessment of cartilage and to compare them with the current gold standard delayed gadolinium-enhanced MR imaging of cartilage (dGEMRIC) measurements. Methods: We employed ex vivo imaging in a preclinical minipig model to assess knee cartilage regeneration. Standardized osteochondral defects were drilled in the proximal femur of the specimens (n=14), which were divided into four groups. Porcine collagen scaffolds seeded with autologous adipose-derived stromal cells (ASC), autologous bone marrow stromal cells (BMSC), and unseeded scaffolds (US) were implanted in femoral defects. Furthermore, there was a defect group which received no treatment. After 6 months, the specimens were examined using different compositional MR methods, including the gold standard dGEMRIC as well as T1, T2, T2*, and T1ρ techniques. The statistical evaluation involved comparing the defect region with the uninjured tibia and femur cartilage layers and all measurements were performed on a clinical 3T MR Scanner. Results: In the untreated defect group, we observed significant differences in the defect region, with dGEMRIC values significantly lower (404.86±64.2 ms, P=0.018) and T2 times significantly higher (44.24±2.75 ms, P<0.001). Contrastingly, in all three treatment groups (ASC, BMSC, US), there were no significant differences among the three regions in the dGEMRIC sequence, suggesting successful cartilage regeneration. However, T1, T2*, and T1ρ sequences failed to detect such differences, highlighting their lower sensitivity for cartilage regeneration. Conclusions: As expected, dGEMRIC is well suited for monitoring cartilage regeneration. Interestingly, T2 imaging also proved to be a reliable cartilage imaging technique and thus offers a contrast agent-free alternative to the former gold standard for subsequent in vivo studies investigating the cartilage regeneration potential of different treatment modalities.

6.
Diagnostics (Basel) ; 13(21)2023 Oct 27.
Article in English | MEDLINE | ID: mdl-37958222

ABSTRACT

Chemical Exchange Saturation Transfer (CEST) magnetic resonance imaging (MRI) provides a novel method for analyzing biomolecule concentrations in tissues without exogenous contrast agents. Despite its potential, achieving a high signal-to-noise ratio (SNR) is imperative for detecting small CEST effects. Traditional metrics such as Magnetization Transfer Ratio Asymmetry (MTRasym) and Lorentzian analyses are vulnerable to image noise, hampering their precision in quantitative concentration estimations. Recent noise-reduction algorithms like principal component analysis (PCA), nonlocal mean filtering (NLM), and block matching combined with 3D filtering (BM3D) have shown promise, as there is a burgeoning interest in the utilization of neural networks (NNs), particularly autoencoders, for imaging denoising. This study uses the Bloch-McConnell equations, which allow for the synthetic generation of CEST images and explores NNs efficacy in denoising these images. Using synthetically generated phantoms, autoencoders were created, and their performance was compared with traditional denoising methods using various datasets. The results underscored the superior performance of NNs, notably the ResUNet architectures, in noise identification and abatement compared to analytical approaches across a wide noise gamut. This superiority was particularly pronounced at elevated noise intensities in the in vitro data. Notably, the neural architectures significantly improved the PSNR values, achieving up to 35.0, while some traditional methods struggled, especially in low-noise reduction scenarios. However, the application to the in vivo data presented challenges due to varying noise profiles. This study accentuates the potential of NNs as robust denoising tools, but their translation to clinical settings warrants further investigation.

7.
Pediatr Radiol ; 53(13): 2608-2621, 2023 12.
Article in English | MEDLINE | ID: mdl-37794175

ABSTRACT

BACKGROUND: Congenital heart disease (CHD) is often associated with chronic right ventricular (RV) volume overload. Real-time magnetic resonance imaging (MRI) enables the analysis of cardiac function during free breathing. OBJECTIVE: To evaluate the influence of respiration in pediatric patients with CHD and chronic RV volume overload. METHODS AND MATERIALS: RV volume overload patients (n=6) and controls (n=6) were recruited for cardiac real-time MRI at 1.5 tesla during free breathing. Breathing curves from regions of interest reflecting the position of the diaphragm served for binning images in four different tidal volume classes, each in inspiration and expiration. Tidal volumes were estimated from these curves by data previously obtained by magnetic resonance-compatible spirometry. Ventricular volumes indexed to body surface area and Frank-Starling relationships referenced to the typical tidal volume indexed to body height (TTVi) were compared. RESULTS: Indexed RV end-diastolic volume (RV-EDVi) and indexed RV stroke volume (RV-SVi) increased during inspiration (RV-EDVi/TTVi: RV load: + 16 ± 4%; controls: + 22 ± 13%; RV-SVi/TTVi: RV load: + 21 ± 6%; controls: + 35 ± 17%; non-significant for comparison). The increase in RV ejection fraction during inspiration was significantly lower in RV load patients (RV load: + 1.1 ± 2.2%; controls: + 6.1 ± 1.5%; P=0.01). The Frank-Starling relationship of the RV provided a significantly reduced slope estimate in RV load patients (inspiration: RV load: 0.75 ± 0.11; controls: 0.92 ± 0.02; P=0.02). CONCLUSION: In pediatric patients with CHD and chronic RV volume overload, cardiac real-time MRI during free breathing in combination with respiratory-based binning indicates an impaired Frank-Starling relationship of the RV.


Subject(s)
Heart Defects, Congenital , Ventricular Dysfunction, Right , Humans , Child , Magnetic Resonance Imaging/methods , Heart Ventricles/diagnostic imaging , Stroke Volume , Respiration , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/complications
8.
Diagnostics (Basel) ; 13(10)2023 May 16.
Article in English | MEDLINE | ID: mdl-37238230

ABSTRACT

(1) Background: We aim to investigate age-related changes in cartilage structure and composition in the metacarpophalangeal (MCP) joints using magnetic resonance (MR) biomarkers. (2) Methods: The cartilage tissue of 90 MCP joints from 30 volunteers without any signs of destruction or inflammation was examined using T1, T2, and T1ρ compositional MR imaging techniques on a 3 Tesla clinical scanner and correlated with age. (3) Results: The T1ρ and T2 relaxation times showed a significant correlation with age (T1ρ: Kendall-τ-b = 0.3, p < 0.001; T2: Kendall-τ-b = 0.2, p = 0.01). No significant correlation was observed for T1 as a function of age (T1: Kendall-τ-b = 0.12, p = 0.13). (4) Conclusions: Our data show an increase in T1ρ and T2 relaxation times with age. We hypothesize that this increase is due to age-related changes in cartilage structure and composition. In future examinations of cartilage using compositional MRI, especially T1ρ and T2 techniques, e.g., in patients with osteoarthritis or rheumatoid arthritis, the age of the patients should be taken into account.

9.
Clin Imaging ; 99: 25-30, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37043870

ABSTRACT

BACKGROUND: To analyze contrast free adrenal vein sampling (AVS) for differentiating unilateral from bilateral disease in patients diagnosed with hypertension due to primary aldosteronism (PA). METHODS: Consecutive patients with PA and subsequent contrast medium free AVS between April 2015 and March 2020 were retrospectively included. Cross-sectional imaging (CSI), AVS and clinical data were analyzed regarding diagnostic performance. In addition, patients with lateralisation receiving adrenalectomy were compared to a control group treated with mineralocorticoid antagonists. RESULTS: In total 186 patients with AVS were included. The success rate for bilateral catheterization was 88% (median effective dose 2.8 mSv). CSI had an accuracy of 60% (CI: 0.52-0.67) in the detection of lateralization compared to AVS. Patients with bilateral adrenal hyperplasia and those with aldosterone-producing adenoma did not differ in systolic blood pressure (sBP) (p = 0.63) or number of antihypertensive drugs (NAD) (p = 0.11). After adrenalectomy, 28 patients were cured (51%; sBP ≤130 mmHg, NAD = 0), 18 were improved (33%; decrease of sBP ≥20 mmHg and NAD), and 8 were unchanged (15%). Serum renin increased significantly after treatment (p < 0.01). CONCLUSION: Contrast medium free AVS is a reliable procedure in the diagnostic management of patients with PA with high technical success rate. The accordance between CSI and results from AVS was only moderate indicating the central role of AVS in the diagnostic work-up of patients with PA. Patients with predominant disease diagnosed with AVS had a high cure rate and/or significant improvement after adrenalectomy.


Subject(s)
Adrenal Glands , Hyperaldosteronism , Humans , Adrenal Glands/diagnostic imaging , Hyperaldosteronism/diagnosis , Hyperaldosteronism/drug therapy , Retrospective Studies , NAD , Adrenalectomy
10.
CVIR Endovasc ; 6(1): 9, 2023 Mar 02.
Article in English | MEDLINE | ID: mdl-36859572

ABSTRACT

BACKGROUND: To investigate the influence of benign prostatic hyperplasia (BPH) patterns detected with MRI on clinical outcomes after prostatic artery embolization (PAE). MATERIALS & METHODS: This retrospective study included 71 consecutive patients with lower urinary tract symptoms (LUTS), who underwent magnetic resonance imaging (MRI) of the prostate followed by PAE at a single centre. MRI scans were evaluated and BPH patterns were determined according to Wasserman type and a modified BPH classification. Additionally, scans were evaluated regarding the presence of adenomatous-dominant benign prostatic hyperplasia (AdBPH). LUTS were assessed using the International Prostate Symptom Score (IPSS) and urinary flow rate (Qmax). Follow-up examination included MRI and clinical outcome. RESULTS: For clinical outcome at follow-up, IPSS showed median reduction of 54% (IQR 41-75%) and Qmax improved by 4.1 ml/s. We noted significant reduction in volume, intraprostatic protrusion, and prostatic urethral angle in our collective (p < 0.01). Median volume reduction was 25% (IQR 15%-34%). Bilateral embolization was a significant predictor for volume reduction at follow-up. Multiple linear regression analysis showed significant effect of high initial volume on reduction in IPSS after treatment (p < 0.01). Presence of AdBPH was significantly associated with both, volume loss and clinical improvement in terms of IPSS reduction (p < 0.01). Neither BPH pattern based on the Wassermann type nor modified BPH classification were significantly related with postinterventional IPSS and volume loss. CONCLUSIONS: Men benefit from PAE regardless the macroscopic BPH MRI pattern. Preinterventional prostate volume and presence of AdBPH on MRI should be considered for outcome prognosis after PAE.

11.
J Med Syst ; 47(1): 39, 2023 Mar 24.
Article in English | MEDLINE | ID: mdl-36961580

ABSTRACT

Analysis of chemical exchange saturation transfer (CEST) MRI data requires sophisticated methods to obtain reliable results about metabolites in the tissue under study. CEST generates z-spectra with multiple components, each originating from individual molecular groups. The individual lines with Lorentzian line shape are mostly overlapping and disturbed by various effects. We present an elaborate method based on an adaptive nonlinear least squares algorithm that provides robust quantification of z-spectra and incorporates prior knowledge in the fitting process. To disseminate CEST to the research community, we developed software as part of this study that runs on the Microsoft Windows operating system and will be made freely available to the community. Special attention has been paid to establish a low entrance threshold and high usability, so that even less experienced users can successfully analyze CEST data.


Subject(s)
Magnetic Resonance Imaging , Software , Humans , Magnetic Resonance Imaging/methods , Algorithms , Least-Squares Analysis
12.
Int J Mol Sci ; 23(18)2022 Sep 17.
Article in English | MEDLINE | ID: mdl-36142810

ABSTRACT

Sodium magnetic resonance imaging (MRI) can be used to evaluate the change in the proteoglycan content in Achilles tendons (ATs) of patients with different AT pathologies by measuring the 23Na signal-to-noise ratio (SNR). As 23Na SNR alone is difficult to compare between different studies, because of the high influence of hardware configurations and sequence settings on the SNR, we further set out to measure the apparent tissue sodium content (aTSC) in the AT as a better comparable parameter. Ten healthy controls and one patient with tendinopathy in the AT were examined using a clinical 3 Tesla (T) MRI scanner in conjunction with a dual tuned 1H/23Na surface coil to measure 23Na SNR and aTSC in their ATs. 23Na T1 and T2* of the AT were also measured for three controls to correct for different relaxation behavior. The results were as follows: 23Na SNR = 11.7 ± 2.2, aTSC = 82.2 ± 13.9 mM, 23Na T1 = 20.4 ± 2.4 ms, 23Na T2s* = 1.4 ± 0.4 ms, and 23Na T2l* = 13.9 ± 0.8 ms for the whole AT of healthy controls with significant regional differences. These are the first reported aTSCs and 23Na relaxation times for the AT using sodium MRI and may serve for future comparability in different studies regarding examinations of diseased ATs with sodium MRI.


Subject(s)
Achilles Tendon , Achilles Tendon/diagnostic imaging , Achilles Tendon/pathology , Humans , Magnetic Resonance Imaging/methods , Proteoglycans , Reproducibility of Results , Sodium
13.
Quant Imaging Med Surg ; 12(8): 4190-4201, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35919061

ABSTRACT

Background: Clinical-standard morphologic magnetic resonance imaging (MRI) is limited in the refined diagnosis of posterior cruciate ligament (PCL) injuries. Quantitative MRI sequences such as ultrashort echo-time (UTE)-T2* mapping or conventional T2* mapping have been theorized to quantify ligament (ultra-) structure and integrity beyond morphology. This study evaluates their diagnostic potential in identifying and differentiating partial and complete PCL injuries in a standardized graded injury model. Methods: Ten human cadaveric knee joint specimens were imaged on a clinical 3.0 T MRI scanner using morphologic, conventional T2* mapping, and UTE-T2* mapping sequences before and after standardized arthroscopic partial and complete PCL transection. Following manual segmentation, quantitative T2* and underlying texture features (i.e., energy, homogeneity, and variance) were analyzed for each specimen and PCL condition, both for the entire PCL and its subregions. For statistical analysis, Friedman's test followed by Dunn's multiple comparison test was used against the level of significance of P≤0.01. Results: For the entire PCL, T2* was significantly increased as a function of injury when acquired with the UTE-T2* sequence [entire PCL: 11.1±3.1 ms (intact); 10.9±4.6 ms (partial); 14.3±4.9 ms (complete); P<0.001], but not when acquired with the conventional T2* sequence [entire PCL: 10.0±3.2 ms (intact); 11.4±6.2 ms (partial); 15.5±7.8 ms (complete); P=0.046]. The PCL subregions and texture variables showed variable changes indicative of injury-associated disorganization. Conclusions: In contrast to the conventional T2* mapping, UTE-T2* mapping is more receptive in the detection of structural damage of the PCL and allows quantitative assessment of ligament (ultra-)structure and integrity that may help to improve diagnostic differentiation of distinct injury states. Once further substantiated beyond the in-situ setting, UTE-T2* mapping may refine diagnostic evaluation of PCL injuries and -possibly- monitor ligament healing, ageing, degeneration, and inflammation.

14.
Int J Mol Sci ; 23(13)2022 Jun 22.
Article in English | MEDLINE | ID: mdl-35805925

ABSTRACT

Based on in silico, in situ, and in vivo studies, this study aims to develop a new method for the quantitative chemical exchange saturation transfer (qCEST) technique considering multi-pool systems. To this end, we extended the state-of-the-art apparent exchange-dependent relaxation (AREX) method with a Lorentzian correction (LAREX). We then validated this new method with in situ and in vivo experiments on human intervertebral discs (IVDs) using the Kendall-Tau correlation coefficient. In the in silico experiments, we observed significant deviations of the AREX method as a function of the underlying exchange rate (kba) and fractional concentration (fb) compared to the ground truth due to the influence of other exchange pools. In comparison to AREX, the LAREX-based Ω-plot approach yielded a substantial improvement. In the subsequent in situ and in vivo experiments on human IVDs, no correlation to the histological reference standard or Pfirrmann classification could be found for the fb (in situ: τ = −0.17 p = 0.51; in vivo: τ = 0.13 p = 0.30) and kba (in situ: τ = 0.042 p = 0.87; in vivo: τ = −0.26 p = 0.04) of Glycosaminoglycan (GAG) with AREX. In contrast, the influence of interfering pools could be corrected by LAREX, and a moderate to strong correlation was observed for the fractional concentration of GAG for both in situ (τ = −0.71 p = 0.005) and in vivo (τ = −0.49 p < 0.001) experiments. The study presented here is the first to introduce a new qCEST method that enables qCEST imaging in systems with multiple proton pools.


Subject(s)
Intervertebral Disc , Magnetic Resonance Imaging , Glycosaminoglycans , Humans , Magnetic Resonance Imaging/methods , Protons
15.
Tomography ; 8(3): 1277-1292, 2022 05 07.
Article in English | MEDLINE | ID: mdl-35645392

ABSTRACT

Based on in silico, in vitro, in situ, and in vivo evaluations, this study aims to establish and optimize the chemical exchange saturation transfer (CEST) imaging of lactate (Lactate-CEST­LATEST). To this end, we optimized LATEST sequences using Bloch−McConnell simulations for optimal detection of lactate with a clinical 3 T MRI scanner. The optimized sequences were used to image variable lactate concentrations in vitro (using phantom measurements), in situ (using nine human cadaveric lower leg specimens), and in vivo (using four healthy volunteers after exertional exercise) that were then statistically analyzed using the non-parametric Friedman test and Kendall Tau-b rank correlation. Within the simulated Bloch−McConnell equations framework, the magnetization transfer ratio asymmetry (MTRasym) value was quantified as 0.4% in the lactate-specific range of 0.5−1 ppm, both in vitro and in situ, and served as the imaging surrogate of the lactate level. In situ, significant differences (p < 0.001) and strong correlations (τ = 0.67) were observed between the MTRasym values and standardized intra-muscular lactate concentrations. In vivo, a temporary increase in the MTRasym values was detected after exertional exercise. In this bench-to-bedside comprehensive feasibility study, different lactate concentrations were detected using an optimized LATEST imaging protocol in vitro, in situ, and in vivo at 3 T, which prospectively paves the way towards non-invasive quantification and monitoring of lactate levels across a broad spectrum of diseases.


Subject(s)
Lactic Acid , Magnetic Resonance Imaging , Humans , Magnetic Resonance Imaging/methods , Phantoms, Imaging , Physical Phenomena , Protons
16.
Pediatr Radiol ; 52(8): 1462-1475, 2022 07.
Article in English | MEDLINE | ID: mdl-35353211

ABSTRACT

BACKGROUND: Cardiac real-time magnetic resonance imaging (RT-MRI) provides high-quality images even during free-breathing. Difficulties in post-processing impede its use in clinical routine. OBJECTIVE: To demonstrate the feasibility of quantitative analysis of cardiac free-breathing RT-MRI and to compare image quality and volumetry during free-breathing RT-MRI in pediatric patients to standard breath-hold cine MRI. MATERIALS AND METHODS: Pediatric patients (n = 22) received cardiac RT-MRI volumetry during free breathing (1.5 T; short axis; 30 frames per s) in addition to standard breath-hold cine imaging in end-expiration. Real-time images were binned retrospectively based on electrocardiography and respiratory bellows. Image quality and volumetry were compared using the European Cardiovascular Magnetic Resonance registry score, structure visibility rating, linear regression and Bland-Altman analyses. RESULTS: Additional time for binning of real-time images was 2 min. For both techniques, image quality was rated good to excellent. RT-MRI was significantly more robust against artifacts (P < 0.01). Linear regression revealed good correlations for the ventricular volumes. Bland-Altman plots showed a good limit of agreement (LoA) for end-diastolic volume (left ventricle [LV]: LoA -0.1 ± 2.7 ml/m2, right ventricle [RV]: LoA -1.9 ± 3.4 ml/m2), end-systolic volume (LV: LoA 0.4 ± 1.9 ml/m2, RV: LoA 0.6 ± 2.0 ml/m2), stroke volume (LV: LoA -0.5 ± 2.3 ml/m2, RV: LoA -2.6 ± 3.3 ml/m2) and ejection fraction (LV: LoA -0.5 ± 1.6%, RV: LoA -2.1 ± 2.8%). CONCLUSION: Compared to standard cine MRI with breath hold, RT-MRI during free breathing with retrospective respiratory binning offers good image quality, reduced image artifacts enabling fast quantitative evaluations of ventricular volumes in clinical practice under physiological conditions.


Subject(s)
Breath Holding , Magnetic Resonance Imaging, Cine , Child , Humans , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging, Cine/methods , Reproducibility of Results , Retrospective Studies , Stroke Volume
17.
Diagnostics (Basel) ; 12(2)2022 Feb 11.
Article in English | MEDLINE | ID: mdl-35204555

ABSTRACT

Currently, clinical indications for the application of gadolinium-based contrast agents (GBCA) in magnetic resonance imaging (MRI) are increasingly being questioned. Consequently, this study aimed to evaluate the additional diagnostic value of contrast enhancement in MRI of the hand in patients with rheumatoid arthritis (RA). Thirty-one patients with RA (mean age, 50 ± 14 years (range, 18-72 years)) underwent morphologic MRI scans on a clinical 3 T scanner. MRI studies were analyzed based on (1) the Rheumatoid Arthritis Magnetic Resonance Imaging Score (RAMRIS) and (2) the GBCA-free RAMRIS version, termed RAMRIS Sine-Gadolinium-For-Experts (RAMRIS-SAFE), in which synovitis and tenosynovitis were assessed using the short-tau inversion-recovery sequence instead of the post-contrast T1-weighted sequence. The synovitis subscores in terms of Spearman's ρ, as based on RAMRIS and RAMRIS-SAFE, were almost perfect (ρ = 0.937; p < 0.001), while the tenosynovitis subscores were less strongly correlated (ρ = 0.380 p = 0.035). Correlation between the total RAMRIS and RAMRIS-SAFE was also almost perfect (ρ = 0.976; p < 0.001). Inter-rater reliability in terms of Cohen's κ was high (0.963 ≤ κ ≤ 0.925). In conclusion, RAMRIS-SAFE as the GBCA-free version of the well-established RAMRIS is a patient-friendly and resource-efficient alternative for assessing disease-related joint changes in RA. As patients with RA are subject to repetitive GBCA applications, non-contrast imaging protocols should be considered.

18.
Diagnostics (Basel) ; 13(1)2022 Dec 29.
Article in English | MEDLINE | ID: mdl-36611395

ABSTRACT

In recent years, much research evaluating the radiographic destruction of finger joints in patients with rheumatoid arthritis (RA) using deep learning models was conducted. Unfortunately, most previous models were not clinically applicable due to the small object regions as well as the close spatial relationship. In recent years, a new network structure called RetinaNets, in combination with the focal loss function, proved reliable for detecting even small objects. Therefore, the study aimed to increase the recognition performance to a clinically valuable level by proposing an innovative approach with adaptive changes in intersection over union (IoU) values during training of Retina Networks using the focal loss error function. To this end, the erosion score was determined using the Sharp van der Heijde (SvH) metric on 300 conventional radiographs from 119 patients with RA. Subsequently, a standard RetinaNet with different IoU values as well as adaptively modified IoU values were trained and compared in terms of accuracy, mean average accuracy (mAP), and IoU. With the proposed approach of adaptive IoU values during training, erosion detection accuracy could be improved to 94% and an mAP of 0.81 ± 0.18. In contrast Retina networks with static IoU values achieved only an accuracy of 80% and an mAP of 0.43 ± 0.24. Thus, adaptive adjustment of IoU values during training is a simple and effective method to increase the recognition accuracy of small objects such as finger and wrist joints.

19.
Diagnostics (Basel) ; 11(10)2021 Sep 28.
Article in English | MEDLINE | ID: mdl-34679487

ABSTRACT

T2 mapping assesses tissue ultrastructure and composition, yet the association of imaging features and tissue functionality is oftentimes unclear. This study aimed to elucidate this association for the posterior cruciate ligament (PCL) across the micro- and macroscale and as a function of loading. Ten human cadaveric knee joints were imaged using a clinical 3.0T scanner and high-resolution morphologic and T2 mapping sequences. Emulating the posterior drawer test, the joints were imaged in the unloaded (δ0) and loaded (δ1) configurations. For the entire PCL, its subregions, and its osseous insertion sites, loading-induced changes were parameterized as summary statistics and texture variables, i.e., entropy, homogeneity, contrast, and variance. Histology confirmed structural integrity. Statistical analysis was based on parametric and non-parametric tests. Mean PCL length (37.8 ± 1.8 mm [δ0]; 44.0 ± 1.6 mm [δ1] [p < 0.01]), mean T2 (35.5 ± 2.0 ms [δ0]; 37.9 ± 1.3 ms [δ1] [p = 0.01]), and mean contrast values (4.0 ± 0.6 [δ0]; 4.9 ± 0.9 [δ1] [p = 0.01]) increased significantly under loading. Other texture features or ligamentous, osseous, and meniscal structures remained unaltered. Beyond providing normative T2 values across various scales and configurations, this study suggests that ligaments can be imaged morphologically and functionally based on joint loading and advanced MRI acquisition and post-processing techniques to assess ligament integrity and functionality in variable diagnostic contexts.

20.
Sci Rep ; 11(1): 19687, 2021 10 04.
Article in English | MEDLINE | ID: mdl-34608233

ABSTRACT

Clinical Magnetic Resonance Imaging (MRI) of joints is limited to mere morphologic evaluation and fails to directly visualize joint or ligament function. In this controlled laboratory study, we show that knee joint functionality may be quantified in situ and as a function of graded posterior cruciate ligament (PCL)-deficiency by combining MRI and standardized loading. 11 human knee joints underwent MRI under standardized posterior loading in the unloaded and loaded (147 N) configurations and in the intact, partially, and completely PCL-injured conditions. For each specimen, configuration, and condition, 3D joint models were implemented to analyse joint kinematics based on 3D Euclidean vectors and their projections on the Cartesian planes. Manual 2D measurements served as reference. With increasing PCL deficiency, vector projections increased significantly in the anteroposterior dimension under loading and manual measurements demonstrated similar patterns of change. Consequently, if combined with advanced image post-processing, stress MRI is a powerful diagnostic adjunct to evaluate ligament functionality and joint laxity in multiple dimensions and may have a role in differentiating PCL injury patterns, therapeutic decision-making, and treatment monitoring.


Subject(s)
Joint Instability/diagnosis , Knee Injuries/diagnosis , Magnetic Resonance Imaging , Posterior Cruciate Ligament/diagnostic imaging , Posterior Cruciate Ligament/physiopathology , Aged , Aged, 80 and over , Female , Humans , Image Processing, Computer-Assisted , Imaging, Three-Dimensional , Joint Instability/etiology , Knee Injuries/etiology , Knee Joint/diagnostic imaging , Knee Joint/pathology , Magnetic Resonance Imaging/methods , Male , Middle Aged
SELECTION OF CITATIONS