1.
Bioengineering (Basel) ; 9(11)2022 Nov 05.
Article in English | MEDLINE | ID: mdl-36354567

ABSTRACT

Microwave ablation is recognized as a minimally invasive, fast-recovery treatment for destroying cancer cells using the heat generated by microwave energy. Despite the unquestionable benefits of microwave ablation, the interaction of the microwave applicator with the tissue may result in localized heating and damage to the surrounding tissue. The majority of the tissue damage can be removed by clarifying the conditions for their development. In addition to experimental methods, computer modeling has proven to be an effective tool for optimizing the performance of microwave ablation. Furthermore, because the thermal spread in biological tissue is difficult to measure, developing a predictive model from procedural planning to execution may have a substantial influence on patient care. The comprehension of heat transport in biological tissues plays a significant role in gaining insight into the mechanisms underlying microwave ablation. Numerical methods that enable ablation size control are required to guarantee tumor destruction and minimize damage to healthy tissues. Various values of input power and ablation time correspond to different tumor shapes ensuring the preservation of healthy tissues. The optimal conditions can be estimated by performing full three-dimensional simulations. This topical review recapitulates numerous computational studies on microwave tumor ablation. Novel areas emerging in treatment planning that exploit the advantages of numerical methods are also discussed. As an illustration, the results of the three-dimensional simulations of real liver tumors in the 3D-IRCADb-01 database are presented and analyzed. The simulation results confirm that numerical methods are very useful tools for modeling microwave tumor ablation with minimal invasiveness and collateral damage.

2.
Biomedicines ; 10(7)2022 Jul 01.
Article in English | MEDLINE | ID: mdl-35884874

ABSTRACT

Simulation techniques are powerful tools for determining the optimal conditions necessary for microwave ablation to be efficient and safe for treating liver tumors. Owing to the complexity and computational resource consumption, most of the existing numerical models are two-dimensional axisymmetric models that emulate actual three-dimensional cancers and the surrounding tissue, which is often far from reality. Different tumor shapes and sizes require different input powers and ablation times to ensure the preservation of healthy tissues that can be determined only by the full three-dimensional simulations. This study aimed to tailor microwave ablation therapeutic conditions for complete tumor ablation with an adequate safety margin, while avoiding injury to the surrounding healthy tissue. Three-dimensional simulations were performed for a multi-slot microwave antenna immersed in two tumors obtained from the 3D-IRCADb-01 liver tumors database. The temperature dependence of the dielectric and thermal properties of healthy and tumoral liver tissues, blood perfusion, and water content are crucial for calculating the correct ablation time and, thereby, the correct ablation process. The developed three-dimensional simulation model may help practitioners in planning patient-individual procedures by determining the optimal input power and duration of the ablation process for the actual shape of the tumor. With proper input power, necrotic tissue is placed mainly in the tumor, and only a small amount of surrounding tissue is damaged.

3.
Cancers (Basel) ; 13(22)2021 Nov 18.
Article in English | MEDLINE | ID: mdl-34830937

ABSTRACT

Microwave ablation at 2.45 GHz is gaining popularity as an alternative therapy to hepatic resection with a higher overall survival rate than external beam radiation therapy and proton beam therapy. It also offers better long-term recurrence-free overall survival when compared with radiofrequency ablation. To improve the design and optimization of microwave ablation procedures, numerical models can provide crucial information. A three-dimensional model of the antenna and targeted tissue without homogeneity assumptions are the most realistic representation of the physical problem. Due to complexity and computational resources consumption, most of the existing numerical studies are based on using two-dimensional axisymmetric models to emulate actual three-dimensional cancers and surrounding tissue, which is often far from reality. The main goal of this study is to develop a fully three-dimensional model of a multislot microwave antenna immersed into liver tissue affected by early-stage hepatocellular carcinoma. The geometry of the tumor is taken from the 3D-IRCADb-01 liver tumors database. Simulations were performed involving the temperature dependence of the blood perfusion, dielectric and thermal properties of both healthy and tumoral liver tissues. The water content changes during the ablation process are also included. The optimal values of the input power and the ablation time are determined to ensure complete treatment of the tumor with minimal damage to the healthy tissue. It was found that a multislot antenna is designed to create predictable, large, spherical zones of the ablation that are not influenced by varying tissue environments. The obtained results may be useful for determining optimal conditions necessary for microwave ablation to be as effective as possible for treating early-stage hepatocellular carcinoma, with minimized invasiveness and collateral damages.

4.
Cancers (Basel) ; 13(14)2021 Jul 13.
Article in English | MEDLINE | ID: mdl-34298714

ABSTRACT

Knowledge of the frequency dependence of the dielectric properties of the lung tissues and temperature profiles are essential characteristics associated with the effective performance of microwave ablation. In microwave ablation, the electromagnetic wave propagates into the biological tissue, resulting in energy absorption and providing the destruction of cancer cells without damaging the healthy tissue. As a consequence of the respiratory movement of the lungs, however, the accurate prediction of the microwave ablation zone has become an exceptionally demanding task. For that purpose, numerical modeling remains a primordial tool for carrying out a parametric study, evaluating the importance of the inherent phenomena, and leading to better optimization of the medical procedure. This paper reports on simulation studies on the effect of the breathing process on power dissipation, temperature distribution, the fraction of damage, and the specific absorption rate during microwave ablation. The simulation results obtained from the relative permittivity and conductivity for inflated and deflated lungs are compared with those obtained regardless of respiration. It is shown that differences in the dielectric properties of inflated and deflated lungs significantly affect the time evolution of the temperature and its maximum value, the time, the fraction of damage, and the specific absorption rate. The fraction of damage determined from the degree of tissue injury reveals that the microwave ablation zone is significantly larger under dynamic physical parameters. At the end of expiration, the ablation lesion area is more concentrated around the tip and slot of the antenna, and the backward heating effect is smaller. The diffuse increase in temperature should reach a certain level to destroy cancer cells without damaging the surrounding tissue. The obtained results can be used as a guideline for determining the optimal conditions to improve the overall success of microwave ablation.

5.
Comput Methods Biomech Biomed Engin ; 24(13): 1409-1418, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33667151

ABSTRACT

This paper reports on safety challenges regarding spark created when the applied electric field exceeds the dielectric breakdown strength as a source of complication during electrosurgery. Despite the unquestionable benefits of electrosurgery, such as minimal chances of infection and fast recovery time, the interaction of the electrosurgical tool with the tissue may result in tissue damage and force feedback to the tool. Some risks of complications often depend on a surgeon's knowledge of instruments and safety aspects of technical equipment that can be eliminated by clarifying the causation and conditions of their development. Current trends in electrosurgery include computational algorithms and methods to control the effect of delivered energy to the patient. For this study, calculations were performed by using the COMSOL simulation package based on a multi-component plasma fluid model. The emphasis is put on conditions that lead to the breakdown of the dielectric medium. It was found that breakdown occurs most easily when both electrodes are cylindrical. For configurations with one or two spherical electrodes, breakdown voltages are higher up to 25% and 48%, respectively. With decreasing the cathode radius, the breakdown voltage may decrease even to 41%. On the other hand, the temperature increase lowers the breakdown voltage. Also, electrical asymmetries appear to be a response to the non-symmetry of the electric field between the electrodes causing differences in the breakdown voltage between 36% and 70%. The results presented here could be very useful for the design of surgical devices to prevent potential complications of electrosurgical procedures.


Subject(s)
Burns , Electrosurgery , Computer Simulation , Electrodes , Electrosurgery/adverse effects , Humans
6.
Micromachines (Basel) ; 11(3)2020 Feb 27.
Article in English | MEDLINE | ID: mdl-32121024

ABSTRACT

This paper presents etching of convex corners with sides along and <100> crystallographic directions in a 25 wt% tetramethylammonium hydroxide (TMAH) water solution at 80 °C. We analyzed parallelograms as the mask patterns for anisotropic wet etching of Si (100). The sides of the parallelograms were designed along and <100> crystallographic directions (1 < n < 8). The acute corners of islands in the masking layer formed by and <100> crystallographic directions were smaller than 45°. All the crystallographic planes that appeared during etching in the experiment were determined. We found that the obtained types of 3D silicon shape sustain when n > 2. The convex corners were not distorted during etching. Therefore, no convex corner compensation is necessary. We fabricated three matrices of parallelograms with sides along crystallographic directions <310> and <100> as examples for possible applications. Additionally, the etching of matrices was simulated by the level set method. We obtained a good agreement between experiments and simulations.

7.
Micromachines (Basel) ; 10(2)2019 Jan 31.
Article in English | MEDLINE | ID: mdl-30708946

ABSTRACT

Squares and circles are basic patterns for most mask designs of silicon microdevices. Evolution of etched Si crystallographic planes defined by square and circle patterns in the masking layer is presented and analyzed in this paper. The sides of square patterns in the masking layer are designed along predetermined crystallographic directions. Etching of a (100) silicon substrate is performed in 25 wt % tetramethylammonium hydroxide (TMAH) water solution at the temperature of 80 °C. Additionally, this paper presents three-dimensional (3D) simulations of the profile evolution during silicon etching of designed patterns based on the level-set method. We analyzed etching of designed patterns in the shape of square and circle islands. The crystallographic planes that appear during etching of 3D structures in the experiment and simulated etching profiles are determined. A good agreement between dominant crystallographic planes through experiments and simulations is obtained. The etch rates of dominant exposed crystallographic planes are also analytically calculated.

8.
Sensors (Basel) ; 10(5): 4950-67, 2010.
Article in English | MEDLINE | ID: mdl-22399916

ABSTRACT

In this paper a methodology for the three dimensional (3D) modeling and simulation of the profile evolution during anisotropic wet etching of silicon based on the level set method is presented. Etching rate anisotropy in silicon is modeled taking into account full silicon symmetry properties, by means of the interpolation technique using experimentally obtained values for the etching rates along thirteen principal and high index directions in KOH solutions. The resulting level set equations are solved using an open source implementation of the sparse field method (ITK library, developed in medical image processing community), extended for the case of non-convex Hamiltonians. Simulation results for some interesting initial 3D shapes, as well as some more practical examples illustrating anisotropic etching simulation in the presence of masks (simple square aperture mask, convex corner undercutting and convex corner compensation, formation of suspended structures) are shown also. The obtained results show that level set method can be used as an effective tool for wet etching process modeling, and that is a viable alternative to the Cellular Automata method which now prevails in the simulations of the wet etching process.