1.
Sci Rep ; 9(1): 9837, 2019 07 08.
Article in English | MEDLINE | ID: mdl-31285533

ABSTRACT

The paper examines the development and testing of an electro-pneumatic device for wound healing therapy after surgery in the neck area. The device generates air pressure values in a miniaturized cuff using electronic circuitry to drive an electro-valve and air compressor. The device works in two distinct modes: continuous pressure mode and pulsating pressure mode. The pressure value setting can vary from 3 to 11 mmHg, and the pulsating pressure mode's operating frequency range is approximately 0.1 to 0.3 Hz. Laboratory measurements were conducted to evaluate the device's correct functioning in both continuous and pulsating pressure modes. A four-day prospective study with animals (n = 10) was also conducted to evaluate neck wound healing therapy using the electro-pneumatic device. Out of the twelve histological parameters analysed to reveal the differences between the experimental and control wounds, only one demonstrated a significant difference. Out of the ten animals treated with the device, three showed a significant difference in terms of benefit after therapy. We can therefore conclude that the device potentially improves the wound healing process in the neck area if the pre-set air pressure value does not exceed 8 mmHg.


Subject(s)
Neck Injuries/therapy , Wound Closure Techniques/instrumentation , Wound Healing , Animals , Disease Models, Animal , Electric Power Supplies , Equipment Design , Neck Injuries/etiology , Prospective Studies , Swine , Treatment Outcome
2.
Physiol Res ; 67(3): 391-399, 2018 07 17.
Article in English | MEDLINE | ID: mdl-29527908

ABSTRACT

We conducted an experimental study to evaluate the presence of coordinated left ventricular mechanical myocardial activity (LVMA) in two types of experimentally induced cardiac arrest: ventricular fibrillation (VF) and pulseless electrical activity (PEA). Twenty anesthetized domestic pigs were randomized 1:1 either to induction of VF or PEA. They were left in nonresuscitated cardiac arrest until the cessation of LVMA and microcirculation. Surface ECG, presence of LVMA by transthoracic echocardiography and sublingual microcirculation were recorded. One minute after induction of cardiac arrest, LVMA was identified in all experimental animals. In the PEA group, rate of LVMA was of 106+/-12/min. In the VF group, we identified two patterns of LVMA. Six animals exhibited contractions of high frequency (VFhigh group), four of low frequency (VFlow group) (334+/-12 vs. 125+/-32/min, p<0.001). A time from cardiac arrest induction to asystole (19.2+/-7.2 vs. 7.3+/-2.2 vs. 8.3+/-5.5 min, p=0.003), cessation of LVMA (11.3+/-5.6 vs. 4.4+/-0.4 vs. 7.4+/-2.9 min, p=0.027) and cessation of microcirculation (25.3+/-12.6 vs. 13.4+/-2.4 vs. 23.2+/-8.7 min, p=0.050) was significantly longer in VFlow group than in VFhigh and PEA group, respectively. Thus, LVMA is present in both VF and PEA type of induced cardiac arrest and moreover, VF may exhibit various patterns of LVMA.


Subject(s)
Heart Arrest/physiopathology , Heart Ventricles/physiopathology , Ventricular Fibrillation/physiopathology , Animals , Female , Swine