Medicine (Baltimore) ; 100(19): e25752, 2021 May 14.
Article in English | MEDLINE | ID: mdl-34106604

ABSTRACT

ABSTRACT: This study was conducted to report long-term outcomes of the frameless robotic stereotactic radiosurgery (SRS) for brain arteriovenous malformation (AVM) at Ramathibodi Hospital.Retrospective data of patients with brain AVM (bAVM), who underwent CyberKnife SRS (CKSRS) at Ramathibodi Hospital from 2009 to 2014, were examined. Exclusion criteria were insufficient follow-up time (<36 months) or incomplete information. Patients' demographics, clinical presentation, treatment parameters, and results were analyzed. Excellent outcome was defined as AVM obliteration without a new neurological deficit. Risk factors for achieving excellent outcome were assessed.From a total of 277 CKSRS treatments for bAVM during the 6 years, 170 AVMs in 166 patients met the inclusion criteria. One hundred and thirty-nine cases (81.76%) presented with hemorrhages from ruptured bAVMs. Almost two-thirds underwent embolization before radiosurgery. With the median AVM volume of 4.17 mL, three-quarters of the cohort had single-fraction CKSRS, utilizing the median prescribed dose of 15 Gray (Gy). In the multisession group (25.29%), the median prescribed dose and the AVM volume were 27.5 Gy and 22.3 mL, respectively. An overall excellent outcome, at a median follow-up period of 72.45 months, was observed in 99 cases (58.24%). Seven AVMs (4.12%) ruptured after CKSRS but 1 patient suffered a new neurological deficit. Two patients (1.18%) were classified into the poor outcome category but there were no deaths. Negative factors for excellent outcome, by multivariate regression analysis, were the male sex and multisession SRS delivery, but not age, history of AVM rupture, previous embolization, or AVM volume.Despite relatively larger bAVM and utilizing a lower prescribed radiation dose, the excellent outcome was within the reported range from previous literature. This study offers one of the longest follow-ups and the largest cohorts from the frameless image-guided robotic SRS community.


Subject(s)
Arteriovenous Fistula/surgery , Intracranial Arteriovenous Malformations/surgery , Radiosurgery/methods , Robotic Surgical Procedures/methods , Surgery, Computer-Assisted/methods , Adolescent , Adult , Female , Follow-Up Studies , Hospitals, University , Humans , Kaplan-Meier Estimate , Logistic Models , Male , Middle Aged , Multivariate Analysis , Retrospective Studies , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...