Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Wilderness Environ Med ; 12(4): 256-62, 2001.
Article in English | MEDLINE | ID: mdl-11769922

ABSTRACT

OBJECTIVE: To confirm that the accumulation of exhaled carbon dioxide (CO2) is the principal cause of nonmechanical asphyxiation during avalanche burial by demonstrating that complete exclusion of exhaled CO2 during experimental snow burial results in normal oxygenation and ventilation utilizing the air within the snowpack. METHODS: In the experimental group, 8 healthy volunteers (mean age 32 years, range 19-44 years) were fully buried up to 90 minutes in compacted snow with a density ranging from 300 to 680 kg/ m3 at an elevation of 2385 m. The 6 men and 2 women breathed directly from the snow utilizing a device containing no air pocket around the inhalation intake, in addition to an extended exhalation tube running completely out of the snowpack to remove all exhaled CO2. Continuous physiologic monitoring included oxygen saturation, end-tidal CO2, inspired CO2, electrocardiogram, rectal core temperature, and respiratory rate. As controls, 5 of the 8 subjects repeated the study protocol breathing directly into a small, fist-sized air pocket with no CO2 removal device. RESULTS: In the experimental group, the mean burial time was 88 minutes, despite the absence of an air pocket. No significant changes occurred in any physiologic parameters in this group compared to baseline values. In contrast, the controls remained buried for a mean of 10 minutes (P = .003) and became significantly hypercapnic (P < .01) and hypoxic (P < .02). CONCLUSIONS: There is sufficient oxygen contained within a densified snowpack comparable to avalanche debris to sustain normal oxygenation and ventilation for at least 90 minutes during snow burial if exhaled CO2 is removed. The prolonged oxygenation observed during CO2 exclusion is irrespective of the presence of an air pocket.


Subject(s)
Asphyxia/prevention & control , Asphyxia/physiopathology , Carbon Dioxide/analysis , Disasters , Oxygen/analysis , Ventilation/instrumentation , Adult , Female , Humans , Male , Snow , Time Factors , Ventilation/methods
2.
JAMA ; 283(17): 2266-71, 2000 May 03.
Article in English | MEDLINE | ID: mdl-10807386

ABSTRACT

CONTEXT: Asphyxia is the most common cause of death after avalanche burial. A device that allows a person to breathe air contained in snow by diverting expired carbon dioxide (CO2) away from a 500-cm3 artificial inspiratory air pocket may improve chances of survival in avalanche burial. OBJECTIVE: To determine the duration of adequate oxygenation and ventilation during burial in dense snow while breathing with vs without the artificial air pocket device. DESIGN: Field study of physiologic respiratory measures during snow burial with and without the device from December 1998 to March 1999. Study burials were terminated at the subject's request, when oxygen saturation as measured by pulse oximetry (SpO2) dropped to less than 84%, or after 60 minutes elapsed. SETTING: Mountainous outdoor site at 2385 m elevation, with an average barometric pressure of 573 mm Hg. PARTICIPANTS: Six male and 2 female volunteers (mean age, 34.6 years; range, 28-39 years). MAIN OUTCOME MEASURES: Burial time, SpO2, partial pressure of end-tidal CO2 (ETCO2), partial pressure of inspiratory CO2 (PICO2), respiratory rate, and heart rate at baseline (in open atmosphere) and during snow burial while breathing with the device and without the device but with a 500-cm3 air pocket in the snow. RESULTS: Mean burial time was 58 minutes (range, 45-60 minutes) with the device and 10 minutes (range, 5-14 minutes) without it (P=.001). A mean baseline SpO2 of 96% (range, 90%-99%) decreased to 90% (range, 77%-96%) in those buried with the device (P=.01) and to 84% (range, 79%-92%) in the control burials (P=.02). Only 1 subject buried with the device, but 6 control subjects buried without the device, decreased SpO2 to less than 88% (P=.005). A mean baseline ETCO2 of 32 mm Hg (range, 27-38 mm Hg) increased to 45 mm Hg (range, 32-53 mm Hg) in the burials with the device (P=.02) and to 54 mm Hg (range, 44-63 mm Hg) in the control burials (P=.02). A mean baseline PICO2 of 2 mm Hg (range, 0-3 mm Hg) increased to 32 mm Hg (range, 20-44 mm Hg) in the burials with the device (P=.01) and to 44 mm Hg (range, 37-50 mm Hg) in the control burials (P=.02). Respiratory and heart rates did not change in burials with the device but significantly increased in control burials. CONCLUSIONS: In our study, although hypercapnia developed, breathing with the device during snow burial considerably extended duration of adequate oxygenation compared with breathing with an air pocket in the snow. Further study will be needed to determine whether the device improves survival during avalanche burial.


Subject(s)
Asphyxia/prevention & control , Disasters , Respiration , Snow , Ventilators, Mechanical , Adult , Equipment Design , Female , Heart Rate , Humans , Male , Mountaineering , Skiing
SELECTION OF CITATIONS
SEARCH DETAIL
...