1.
Clin Chem Lab Med ; 61(8): 1511-1517, 2023 07 26.
Article in English | MEDLINE | ID: mdl-36799248

ABSTRACT

OBJECTIVES: To evaluate pre-analytical challenges related to high-volume central laboratory SARS-CoV-2 antigen testing with a prototype qualitative SARS-CoV-2 antigen immunoassay run on the automated Abbott ARCHITECT instrument. METHODS: Contrived positive and negative specimens and de-identified nasal and nasopharyngeal specimens in transport media were used to evaluate specimen and reagent on-board stability, assay analytical performance and interference, and clinical performance. RESULTS: TCID50/mL values were similar for specimens in various transport media. Inactivated positive clinical specimens and viral lysate (USA-WA1/2020) were positive on the prototype immunoassay. Within-laboratory imprecision was ≤0.10 SD (<1.00 S/C) with a ≤10% CV (≥1.00 S/C). Assay reagents were stable on board the instrument for 14 days. No high-dose hook effect was observed with a SARS-CoV-2 stock of Ct 13.0 (RLU>1.0 × 106). No interference was observed from mucin, whole blood, 12 drugs, and more than 20 cross-reactants. While specimen stability was limited at room temperature for specimens with or without viral inactivation, a single freeze/thaw cycle or long-term storage (>30 days) at -20 °C did not adversely impact specimen stability or assay performance. Specificity of the prototype SARS-CoV-2 antigen immunoassay was ≥98.5% and sensitivity was ≥89.5% across two ARCHITECT instruments. Assay sensitivity was inversely correlated with Ct and was similar to that reported for the Roche Elecsys® SARS-CoV-2 Ag immunoassay. CONCLUSIONS: The prototype SARS-CoV-2 antigen ARCHITECT immunoassay is sensitive and specific for detection of SARS-CoV-2 in nasal and nasopharyngeal specimens. Endogenous proteases in mucus may degrade the target antigen, which limits specimen storage and transport times and complicates assay workflow.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Sensitivity and Specificity , COVID-19 Testing , Immunoassay
2.
Biotechniques ; 73(3): 136-141, 2022 09.
Article in English | MEDLINE | ID: mdl-36004516

ABSTRACT

Mutations in the nucleocapsid of SARS-CoV-2 may interfere with antigen detection by diagnostic tests. We used several methods to evaluate the effect of various SARS-CoV-2 nucleocapsid mutations on the performance of the Panbio™ and BinaxNOW™ lateral flow rapid antigen tests and a prototype high-throughput immunoassay that utilizes Panbio antibodies. Variant detection was also evaluated by immunoblot and BIAcore™ assay. A panel of 23 recombinant nucleocapsid antigens (rAgs) were produced that included mutations found in circulating SARS-CoV-2 variants, including variants of concern. All mutant rAgs were detected by all assays, at a sensitivity equivalent to wild-type control (Wuhan strain). Thus, using a rAg approach, we found that the SARS-CoV-2 nucleocapsid mutations examined do not directly impact antigen detection or antigen assay performance.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , COVID-19/diagnosis , COVID-19/genetics , COVID-19 Testing , Diagnostic Tests, Routine , Humans , Mutation , Nucleocapsid/genetics , SARS-CoV-2/genetics , Sensitivity and Specificity
3.
Pract Lab Med ; 9: 58-68, 2017 Dec.
Article in English | MEDLINE | ID: mdl-29159257

ABSTRACT

BACKGROUND: Dipeptidyl peptidase-4 (DPP-4) may be a suitable biomarker to identify people with severe asthma who have greater activation of the interleukin-13 (IL-13) pathway and may therefore benefit from IL-13-targeted treatments. We report the analytical performance of an Investigational Use Only immunoassay and provide data on the biological range of DPP-4 concentrations. METHODS: We assessed assay performance, utilising analyses of precision, linearity and sensitivity; interference from common endogenous assay interferents, and from asthma and anti-diabetic medications, were also assessed. The assay was used to measure the range of serum DPP-4 concentrations in healthy volunteers and subjects with diabetes and severe, uncontrolled asthma. RESULTS: The total precision of DPP-4 concentration measurement (determined using percentage coefficient of variation) was ≤5% over 20 days. Dilution analysis yielded linear results from 30 to 1305 ng/mL; the limit of quantitation was 19.2 ng/mL. No notable endogenous or drug interferences were observed at the expected therapeutic concentration. Median DPP-4 concentrations in healthy volunteers and subjects with asthma or Type 1 diabetes were assessed, with concentrations remaining similar in subjects with diabetes and asthma across different demographics. CONCLUSION: These analyses indicate that the ARCHITECT DPP-4 Immunoassay is a reliable and robust method for measuring serum DPP-4 concentration.

4.
Anal Biochem ; 486: 78-80, 2015 Oct 01.
Article in English | MEDLINE | ID: mdl-26150094

ABSTRACT

Sodium dodecyl sulfate (SDS) is used to denature and solubilize proteins, especially membrane and other hydrophobic proteins. A quantitative method to determine the concentration of SDS using the dye Stains-All is known. However, this method lacks the accuracy and reproducibility necessary for use with protein solutions where SDS concentration is a critical factor, so we modified this method after examining multiple parameters (solvent, pH, buffers, and light exposure). The improved method is simple to implement, robust, accurate, and (most important) precise.


Subject(s)
Sodium Dodecyl Sulfate/analysis , Spectrophotometry/methods , Hydrogen-Ion Concentration , Light , Limit of Detection , Reproducibility of Results , Solvents/chemistry
5.
Electrophoresis ; 34(6): 825-32, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23307430

ABSTRACT

Several method parameters have been refined for application of CIEF methods to provide optimal capillary robustness and performance longevity while maintaining desired analytical output for the ever increasing characterization scrutiny of protein reagents used in clinical assay formulations. Demonstrated here are significant modifications to the existing protocols in order to attain a robust, reproducible method that achieves as much as a 20-fold increase in the number of consecutive runs before capillary degradation. Not only is it a concern for the rudimentary analysis of acidic and basic components of the isoform profile for monoclonal antibodies, but a comprehensive identification of each individual isoform to obtain a characteristic fingerprint is necessary for minor distinguishable properties between multiple proteins in unambiguous identification. In order to maintain the integrity of these modifications, extensive studies were conducted on an implemented system suitability standard protein with specifically defined parameters indicating either sufficient or poor separation performance.


Subject(s)
Antibodies, Monoclonal/analysis , Isoelectric Focusing/methods , Protein Isoforms/analysis , Electrophoresis, Capillary/methods , Immunologic Tests/methods , Isoelectric Focusing/standards , Reproducibility of Results
6.
Anal Biochem ; 415(2): 116-25, 2011 Aug 15.
Article in English | MEDLINE | ID: mdl-21549681

ABSTRACT

Classic blotting methods remain a commonly applied approach to specific protein identification in gel electrophoresis of complex mixtures despite the inherent difficulty in band or spot matching due to significant variability of protein migration or localization in replicate blotting experiments. A direct application of both protein stain and protein blotting on a single membrane significantly reduces the complexity of the experiment and provides increased confidence of signal matching. Digital alignment of images acquired from both total protein stain and blotting development modes on a single membrane allows unambiguous spot or band assignments in these experiments as well as retention of quantitative information acquired from both modes of signal generation. A direct and simple method applying a fluorescent protein stain that is compatible with subsequent detection by antibody or lectin recognition factors along with common image adjustment software is examined. The utility of this blot dual-mode development method for direct protein recognition and quantification in one- and two-dimensional electrophoresis is demonstrated for bioanalytical objectives where replicate experiments are challenged by sample complexity.


Subject(s)
Molecular Probe Techniques , Proteins/analysis , Antibodies/chemistry , Blotting, Western , Electrophoresis, Gel, Two-Dimensional/methods , Electrophoresis, Polyacrylamide Gel/methods , Humans , Image Processing, Computer-Assisted , Lectins/chemistry , Organometallic Compounds/chemistry , Recombinant Proteins/analysis , Recombinant Proteins/metabolism