Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Oral Health ; 24(1): 712, 2024 Jun 20.
Article in English | MEDLINE | ID: mdl-38902697

ABSTRACT

OBJECTIVE: To evaluate the effects of different polishing techniques and coffee staining on the color stability of four commercially available bleach-shade composite resins, namely microhybrid, nanohybrid, nanofilled, and injectable nanohybrids. MATERIAL AND METHODS: A total of 224 discs (8 mm diameter and 2 mm thickness) were fabricated from four different bleach-shade composite resins, namely microhybrid (Gradia Direct Anterior), nanohybrid (Palfique LX5), nanofilled (Filtek Universal), and injectable nanohybrid (flowable G-aenial universal injectable). The composite resin groups were polished via four techniques: no polishing, 4-step polishing using aluminum oxide discs, 3-step polishing using silicon rubber diamond discs, and one-step polishing. Half of each group was immersed in water, while the other half was immersed in coffee for 12 days (n = 7). Colors were measured using a clinical spectrophotometer, and color differences were calculated (ΔE). The results were analyzed statistically. RESULTS: The alterations in color were significantly influenced by the techniques employed for finishing and polishing techniques, composite resin type, and degree of coffee staining. Regardless of the polishing technique and storage medium, different material types showed a significant color change (ΔE) at P < 0.001. Filtek exhibited the most significant color change, followed by Gradia and Palfique, with no significant differences between them. In addition, Different polishing techniques resulted in significant color changes (P < 0.001). The highest degree of color change was seen in the no-polishing group, followed by the 4-step and 1-step polishing groups, with negligible differences between each other. Also, Storage media had a significant effect on ΔE values. CONCLUSION: Appropriate finishing and polishing procedures can improve the color stability of bleach-shaded composite resins. Coffee has a deleterious effect on color; however, injectable flowable nanohybrid composites are more resistant to staining.


Subject(s)
Aluminum Oxide , Coffee , Color , Composite Resins , Dental Polishing , Surface Properties , Composite Resins/chemistry , Dental Polishing/methods , Aluminum Oxide/chemistry , Materials Testing , Spectrophotometry , In Vitro Techniques , Humans , Diamond/chemistry , Nanocomposites/chemistry , Tooth Bleaching Agents/chemistry , Water/chemistry , Dental Materials/chemistry , Time Factors
2.
J Contemp Dent Pract ; 24(9): 668-673, 2023 Sep 01.
Article in English | MEDLINE | ID: mdl-38152940

ABSTRACT

AIM: To compare fracture resistance of multiple treatment modalities intended for mutilated teeth using polyether ether ketone (PEEK) and zirconia materials. MATERIALS AND METHODS: The study was divided into four groups according to treatment modality adopted (n = 14): fiber post (F), Nayyar core (N), endocrown (E), and Richmond crown (R). Each group was further subdivided into two groups (n = 7) according to the type of material used: zirconia (Z) and PEEK (P). Using computer-aided design/computer-aided manufacturing, restorations were constructed from both materials following tested treatment options and manufacturer direction. Finished restorations were then tried, seated, and cemented to their corresponding acrylic teeth. All specimens were tested for fracture resistance in universal testing machine with cross head speed of 0.5 mm/min speed until failure, which was confirmed by a sudden drop in the measurements of the testing machine. Results were recorded, tabulated, and statistically analyzed. Shapiro-Wilk normality tests were considered to evaluate the normality of the data distributions. One-way analysis of variance (ANOVA) followed by Tukey's post hoc analysis was conducted to analyze the fracture resistance significant differences. RESULTS: Descriptive statistics of the restoration material revealed statistically a higher mean value for PEEK material (3609 ± 188.1) than zirconia (2404 ± 425.6). One-way ANOVA revealed statistically significant differences between zirconia group (p < 0.0001). Regarding zirconia group statistical significance was detected between fiber post vs endocrown (p = 0.0299), fiber post vs Richmond crown (p < 0.0001), and Nayyar core vs Richmond crown (p = 0.0004). However, there was no statistically significant difference between PEEK group (P = 0.1614). CONCLUSION: Polyether ether ketone could present a reliable treatment option in endodontically treated teeth. CLINICAL SIGNIFICANCE: Using one-piece Richmond crowns constructed of PEEK could present a viable treatment option against conventional treatment options of root canal treatment (RCT) single-rooted teeth.


Subject(s)
Post and Core Technique , Tooth, Nonvital , Humans , Tooth, Nonvital/therapy , Crowns , Ethers , Dental Stress Analysis , Materials Testing , Dental Restoration Failure
3.
J Int Soc Prev Community Dent ; 10(3): 246-254, 2020.
Article in English | MEDLINE | ID: mdl-32802769

ABSTRACT

AIM AND OBJECTIVES: The aim of this study was to evaluate and compare the diagnostic performance of a quantitative light-induced fluorescence (DIAGNOdent pen [DP]) and a photothermal radiometry (Canary System [CS]) for assessment and monitoring occlusal enamel caries under fissure sealants placed on young permanent teeth. MATERIALS AND METHODS: Forty-five patients of mean age 9.96 (1.4) years, having at least two occlusal surface sites of non-cavitated lesions (International Caries Detection and Assessment System [ICDAS], 1-3 at baseline), were assigned for this clinical study as per specific inclusion/exclusion criteria. A total of 90 permanent teeth were examined using a visual examination method (ICDAS), a quantitative light-induced fluorescence (DP), and a photothermal radiometry (CS). Teeth were randomly divided into two groups based on the type of fissure sealants: a resin sealant and a glass-ionomer sealant. Sealants were placed over the study sites, and caries assessment was performed with each caries detection method at 3- and 6-month recall appointments. Numerical data were presented as mean, standard deviation, median, and interquartile range values. Qualitative data were presented as frequencies and percentages. Receiver operating characteristic (ROC) curve was constructed to determine the diagnostic accuracy measures of the two modalities and compared using z-statistic. ROC curve analysis was performed with MedCalc software, Ostend, Belgium, version 11.3 for Windows (MedCalc Software). Changes by time in caries progression were analyzed using McNemar test and Cochran Q test. The significance level was set at P ≤ 0.05. Statistical analysis was performed with the IBM Statistical Package for the Social Sciences (SPSS) software for Windows, version 23.0 (IBM, Armonk, New York). RESULTS: The CS and DP were able to distinguish between sound and carious tissue beneath fully and partially retained sealants at 6-month follow-up with an accuracy of 46.7% and 33.4%, respectively. CONCLUSION: The diagnostic performance of the CS and DP are acceptable and can be considered as useful adjunct tools in the clinical evaluation and monitoring the changes in enamel due to lesion progression under fissure sealants. However, in the clinical setting, sensitivity and specificity of these devices may be influenced by the sealant type, thickness, retention, and the differences in the lesion characteristics over time.

4.
Article in English | MEDLINE | ID: mdl-32454960

ABSTRACT

Background. The effectiveness of fissure sealants in caries prevention depends on their long-term retention and ability to stop caries progression. This randomized controlled clinical trial compared the retention rate and cariostatic properties of a contemporary glass-ionomer-based sealant (GIS) versus a resin-based sealant (RS) placed on fully erupted permanent molars in a split-mouth design. Methods. The sealants were placed on fully erupted permanent teeth (8‒12 years of age) in 45 children. The evaluation was conducted after one week and three and six months. Results. There was a statistically significant difference in the retention rate and caries transition between the two groups over a six-month clinical evaluation period. The resin-based sealant group showed a better retention rate than the GIS group (75.56% and 48.88%, respectively). The resin-based sealant was superior to GIS in preventing caries progression. Conclusion. Resin-based fissure sealant with fluoride releasing properties might be preferable in preventing caries progression of incipient non-cavitated carious lesions in fully-erupted teeth.

5.
Eur J Dent ; 14(2): 327-330, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32164032

ABSTRACT

Try-in sessions are often performed to check the fit and shape of restorations; however, try-in pastes do not exhibit enough viscosity to keep the restoration in place especially in the case of veneers that keep falling off during try-in. The use of polymerizable soft resins similar to those used as a gingival barrier in bleaching treatment can lock the veneer or crown in place during try-in for dynamic assessment of the restoration, at the same time easy removal of the paste is possible since the resin film is peeled off in one piece leaving no residues for cleanup.

6.
J Adhes Dent ; 20(1): 33-39, 2018.
Article in English | MEDLINE | ID: mdl-29507918

ABSTRACT

PURPOSE: To evaluate the influence of different aging techniques on zirconia-composite microtensile bond strength using different surface treatments over a 5-year follow-up period. MATERIALS AND METHODS: Zirconia disks received three surface treatments: airborne-particle abrasion with 50-µm aluminum oxide particles, selective infiltration etching (SIE), or fusion sputtering (FS). The specimens were bonded to pre-aged composite disks using a composite cement containing phosphate monomers (Panavia F2.0). Bonded specimens were sectioned into microbars (1 x 1 x 6 mm) using a precision cutting machine, and all microbars received thermocycling (15,000 cycles between 5°C and 55°C). Initial microtensile bond strength was evaluated, and the test was repeated after storage in the following media for five years (artificial saliva, 20% ethanol, 5% NaOH, 4% acetic acid, and 5% phosphoric acid). The test was repeated every 12 months for 5 years. Scanning electron microscopic images were used to analyze the zirconia-composite interface. A repeated measures ANOVA and Bonferroni post-hoc tests were used to analyze the data (n = 20, α = 0.05). RESULTS: Significantly higher microtensile bond strength was observed for SIE compared to fusion sputtering and airborne particle abrasion. Five years of artificial aging resulted in significant reduction of zirconia-composite bond strength for all tested specimens. Zirconia-composite bond strength was more sensitive to storage in sodium hydroxide and phosphoric acid, while it was least affected when stored under saliva. These changes were related to the mechanism of ultra-structural interaction between surface treatment and adhesive, as deterioration of the hybrid layer (composite-infiltrated ceramic) was responsible for bond degeneration. CONCLUSION: Zirconia-composite bond strength was influenced by 5 years of artificial aging.


Subject(s)
Dental Bonding , Resin Cements , Composite Resins , Dental Etching , Materials Testing , Stress, Mechanical , Surface Properties , Tensile Strength , Zirconium
7.
Int J Esthet Dent ; 9(1): 90-7, 2014.
Article in English | MEDLINE | ID: mdl-24757701

ABSTRACT

OBJECTIVE: To investigate the influence of translucency of CAD/CAM ceramic milling blocks on the final color of porcelain veneer cemented using resin cement with two different opacities. MATERIALS AND METHODS: A standardized incisal lap preparation was made on a maxillary right central incisor that was duplicated using composite resin material (Z250, A4, 3M ESPE). The resin dies were individually laser scanned (Bluecam, Sirona) in order to build a 3D model of the porcelain veneer on the CAD software (Cerec 3D). Three types of milling blocks were used to fabricate the required restorations: multichromatic, high translucency, and low translucency milling blocks (IPS Empress CAD, A1 Vita shade tab). The milled veneers were polished, glazed, and bonded on the resin dies using high opacity and low opacity resin cements (Panavia F2.0). A digital shade guide device (Easyshade Advance, Vita) was used to measure color parameters (CIE Lab values) at the incisal, middle, and cervical third of each cemented restoration. ΔE values of the cemented veneers were calculated against the target color (A1). RESULTS: Cementation of porcelain veneers resulted in significant color change of the resin die (A4) as ΔE values ranged between 8.9 and 13.7. However, the type of milling block did not have an observable effect on final color as the measured ΔE values, against original die color, were very close for the multichromatic block (ΔE = 10.7 ± 0.1), high translucency (ΔE = 9.7 ± 0.09), and low translucency blocks (ΔE = 13.4 ± 0.11). The opacity of the used resin cement did not affect the final shade match, as the observed ΔE values using either high opacity and low opacity resin cement were less than 2 for the three used ceramic blocks. The greatest color difference was observed between the incisal third of multichromatic veneers (ΔE = 8.9) and the cervical third of low translucency veneers (ΔE = 13.7), while for the rest of the test groups this shift was not clinically observable (ΔE < 2.5). CONCLUSION: Within the limitations of this study, the shade match of CAD/CAM porcelain veneers was not influenced by the translucency of used milling block or the opacity of the resin cement.


Subject(s)
Computer-Aided Design , Dental Porcelain/chemistry , Dental Veneers , Prosthesis Coloring , Aluminum Silicates/chemistry , Cementation/methods , Ceramics/chemistry , Color , Composite Resins/chemistry , Dental Polishing/methods , Humans , Imaging, Three-Dimensional/methods , Incisor , Light , Prosthesis Coloring/instrumentation , Resin Cements/chemistry , Software , Surface Properties
SELECTION OF CITATIONS