Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Asian Cardiovasc Thorac Ann ; 29(8): 822-825, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33789441

ABSTRACT

Acquired submitral aneurysm after mitral valve replacement is caused by weakness of the annular tissues induced by inflammation, scarring, and ischemia from surgical trauma. The asynchronous stretch of the annulus caused by the submitral aneurysm may cause recurrent paravalvular leaks. In patients with acquired submitral aneurysms and paravalvular leaks, ideal solution is a repeat surgery to address both the aneurysm and the leak. However, when patients are at high risk for repeat surgeries on cardiopulmonary bypass through sternotomy, transcatheter closure of these paravalvar leaks may offer an alternative solution. Four such procedures in three patients are detailed in this report.


Subject(s)
Aneurysm , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Mitral Valve Insufficiency , Cardiac Catheterization , Echocardiography, Transesophageal , Humans , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology , Mitral Valve Insufficiency/surgery , Prosthesis Failure
2.
Indian Heart J ; 72(5): 369-375, 2020.
Article in English | MEDLINE | ID: mdl-33189196

ABSTRACT

OBJECTIVES: Left atrial appendage occlusion (LAAO) in non-valvar atrial fibrillation (AF) reduces cardioembolic strokes. Despite increased risk, trials exclude valvar AF in structural heart diseases where clots extend beyond appendage. METHODS: Patients with AF and relative risks for oral anticoagulation (OAC) needing structural interventions underwent concomitant LAAO. After six months of OAC, aspirin was continued. Transesophageal echocardiogram was done three monthly till one year and yearly thereafter. The patient demographics, procedural details, post-procedural follow-up were analyzed. RESULTS: Nine patients aged 51.5 ± 6.3 years with AF underwent LAAO concomitantly with balloon mitral valvotomy in four patients, atrial septal defect device closure in four and periprosthetic mitral leak closure in one patient. Six patients had heart failure, four had prior embolic events, and two had documented LAA thrombus. The mean CHADS2VASc score was 2.44 ± 0.8 and mean HASBLED score was 3.0 ± 0.8. Devices included Amplatzer Cardiac Plug™ in six patients, LAmbre™ Lifetech device in two and Watchman™ device in one. All procedures were successful without acute complications. A patient developed pericardial effusion at six months requiring pericardiocentesis. Early device-associated thrombus in one patient resolved after OAC for six months. No embolic events occurred on follow-up. CONCLUSION: On a detailed literature search, this largest LAAO experience in structural heart diseases indicates its utility. OAC for six months followed by aspirin seems to prevent thrombus formation in these patients. The only incidence of early thrombus formation indicates immunity from clot formation after device endothelialisation. Larger multicenter trials combining LAAO with structural interventions in valvular AF are warranted in developing nations.


Subject(s)
Atrial Appendage/surgery , Atrial Fibrillation/surgery , Cardiac Catheterization/methods , Cardiac Surgical Procedures/methods , Septal Occluder Device , Stroke/prevention & control , Adult , Aged , Atrial Appendage/diagnostic imaging , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Echocardiography, Transesophageal , Female , Humans , Male , Middle Aged , Registries , Stroke/etiology , Treatment Outcome
3.
Catheter Cardiovasc Interv ; 96(2): 367-375, 2020 08.
Article in English | MEDLINE | ID: mdl-31999067

ABSTRACT

OBJECTIVES: We present a first-in-man clinical use of a new hybrid design stent in stenosed large vessels. Its unique C and S polylinks prevent foreshortening without compromising its strength. Its thin profile permits use of smaller introducer sheaths. BACKGROUND: Stent angioplasty is widely employed in large vessel and conduit stenosis. These procedures are associated with difficulties due to large stent profiles, stent fractures, foreshortening and recoil. Cobalt chromium stents have high tensile strengths compared to stainless steel stents. METHODS: A retrospective analysis of feasibility and safety of a new Cobalt chromium stent in large vessels namely aorta, pulmonary arteries and outflow conduits was done from two institutions. Demographic patient details, procedural results, complications and medium term follow-up were analyzed. Stent recoil, foreshortening, fractures were assessed. RESULTS: Twenty patients including three with aortic coarctations, seven with stenosed conduits and 10 with pulmonary artery stenosis underwent stent angioplasty using 23 stents. Three stents were deployed to expand further a previously implanted stent. Procedure was successful in all patients, lumen increased by 150-300%, gradients reduced in all patients. There was no stent recoil, foreshortening or fractures. There were no complications. At a follow up of 3-27 months, there were no stent related complications and the gradients remained stable. CONCLUSIONS: The new Zephyr stent was useful in a wide variety of stenotic lesions involving large vessels including those that were previously stented. Lack of stent recoil and foreshortening seems to be an advantage for this new stent that needs validation in larger multicenter studies.


Subject(s)
Aortic Coarctation/therapy , Chromium Alloys , Endovascular Procedures/instrumentation , Fontan Procedure/adverse effects , Graft Occlusion, Vascular/therapy , Stenosis, Pulmonary Artery/therapy , Stents , Adolescent , Adult , Aortic Coarctation/diagnostic imaging , Aortic Coarctation/physiopathology , Child , Child, Preschool , Endovascular Procedures/adverse effects , Feasibility Studies , Female , Graft Occlusion, Vascular/diagnostic imaging , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Humans , India , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Stenosis, Pulmonary Artery/diagnostic imaging , Stenosis, Pulmonary Artery/etiology , Stenosis, Pulmonary Artery/physiopathology , Tensile Strength , Time Factors , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...