Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
JOR Spine ; 7(2): e1332, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38655007

ABSTRACT

Background: Nucleus replacement devices (NRDs) are not routinely used in clinic, predominantly due to the risk of device expulsion. Rigorous in vitro testing may enable failure mechanisms to be identified prior to clinical trials; however, current testing standards do not specify a particular expulsion test. Multiple methods have therefore been developed, complicating comparisons between NRD designs. Thus, this study assessed the effectiveness of four previously reported expulsion testing protocols; hula-hoop (Protocol 1), adapted hula-hoop (Protocol 2), eccentric cycling (Protocol 3), and ramp to failure (Protocol 4), applied to two NRDs, one preformed and one in situ curing. Methods: Nucleus material was removed from 40 bovine tail intervertebral disks. A NRD was inserted posteriorly into each cavity and the disks were subjected to one of four expulsion protocols. Results: NRD response was dependent on both the NRD design and the loading protocol. Protocol 1 resulted in higher migration and earlier failure rates compared to Protocol 2 in both NRDs. The preformed NRD was more likely to migrate when protocols incorporated rotation. The NRDs had equal migration (60%) and expulsion (60%) rates when using unilateral bending and ramp testing. Combining the results of multiple tests revealed complimentary information regarding the NRD response. Conclusions: Adapted hula-hoop (Protocol 2) and ramp to failure (Protocol 4), combined with fluoroscopic analysis, revealed complimentary insights regarding migration and failure risk. Therefore, when adopting the surgical approach and animal model used in this study, it is recommended that NRD performance be assessed using both a cyclic and ramp loading protocol.

2.
Front Bioeng Biotechnol ; 11: 1229388, 2023.
Article in English | MEDLINE | ID: mdl-37849982

ABSTRACT

Introduction: Nucleus replacement has been proposed as a treatment to restore biomechanics and relieve pain in degenerate intervertebral discs (IVDs). Multiple nucleus replacement devices (NRDs) have been developed, however, none are currently used routinely in clinic. A better understanding of the interactions between NRDs and surrounding tissues may provide insight into the causes of implant failure and provide target properties for future NRD designs. The aim of this study was to non-invasively quantify 3D strains within the IVD through three stages of nucleus replacement surgery: intact, post-nuclectomy, and post-treatment. Methods: Digital volume correlation (DVC) combined with 9.4T MRI was used to measure strains in seven human cadaveric specimens (42 ± 18 years) when axially compressed to 1 kN. Nucleus material was removed from each specimen creating a cavity that was filled with a hydrogel-based NRD. Results: Nucleus removal led to loss of disc height (12.6 ± 4.4%, p = 0.004) which was restored post-treatment (within 5.3 ± 3.1% of the intact state, p > 0.05). Nuclectomy led to increased circumferential strains in the lateral annulus region compared to the intact state (-4.0 ± 3.4% vs. 1.7 ± 6.0%, p = 0.013), and increased maximum shear strains in the posterior annulus region (14.6 ± 1.7% vs. 19.4 ± 2.6%, p = 0.021). In both cases, the NRD was able to restore these strain values to their intact levels (p ≥ 0.192). Discussion: The ability of the NRD to restore IVD biomechanics and some strain types to intact state levels supports nucleus replacement surgery as a viable treatment option. The DVC-MRI method used in the present study could serve as a useful tool to assess future NRD designs to help improve performance in future clinical trials.

3.
JOR Spine ; 6(2): e1232, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37361334

ABSTRACT

Background: Nuclectomy, also known as nucleotomy, is a percutaneous surgical procedure performed to remove nucleus material from the center of the disc. Multiple techniques have been considered to perform a nuclectomy, however, the advantages and disadvantages of each are not well understood. Aims: This in vitro biomechanical investigation on human cadaveric specimens aimed to quantitatively compare three nuclectomy techniques performed using an automated shaver, rongeurs, and laser. Material & Methods: Comparisons were made in terms of mass, volume and location of material removal, changes in disc height, and stiffness. Fifteen vertebra-disc-vertebra lumbar specimens were acquired from six donors (40 ± 13 years) and split into three groups. Before and after nucleotomy axial mechanical tests were performed and T2-weighted 9.4T MRIs were acquired for each specimen. Results: When using the automated shaver and rongeurs similar volumes of disc material were removed (2.51 ± 1.10% and 2.76 ± 1.39% of the total disc volume, respectively), while considerably less material was removed using the laser (0.12 ± 0.07%). Nuclectomy using the automated shaver and rongeurs significantly reduced the toe-region stiffness (p = 0.036), while the reduction in the linear region stiffness was significant only for the rongeurs group (p = 0.011). Post-nuclectomy, 60% of the rongeurs group specimens showed changes in the endplate profile while 40% from the laser group showed subchondral marrow changes. Discussion: From the MRIs, homogeneous cavities were seen in the center of the disc when using the automated shaver. When using rongeurs, material was removed non-homogeneously both from the nucleus and annulus regions. Laser ablation formed small and localized cavities suggesting that the technique is not suitable to remove large volumes of material unless it is developed and optimized for this application. Conclusion: The results demonstrate that both rongeurs and automated shavers can be used to remove large volumes of NP material but the reduced risk of collateral damage to surrounding tissues suggests that the automated shaver may be more suitable.

4.
Habitat Int ; 121: 102517, 2022 Mar.
Article in English | MEDLINE | ID: mdl-35125583

ABSTRACT

COVID-19 initially spread among prominent global cities and soon to the urban centers of countries across the globe. While cities are the hotbeds of activities, they also seem highly exposed to global risks including the pandemic. Using the case of COVID-19 and the World Risk Index framework, this paper examines if the leading cities from the global south are inherently vulnerable and exposed to global risks and can they exacerbate the overall risk of their respective nations. Compared against their respective national averages, most of the 20 cities from 10 countries analyzed in this paper, have higher exposure, lower adaptive capacity, higher coping capacity and varied susceptibility. As this relative understanding is based on respective national averages which are often lower than the global standards, even high performance on certain indicators may still result in elevated predisposition. This paper concludes that the leading urban centers from the global south are highly likely to be predisposed to global risks due to their inherent vulnerability and exposure, and many of the drivers of this predisposition are related to the process of urbanization itself. This predisposition can enhance the overall exposure and vulnerability of the nation in which they are located.

5.
Front Bioeng Biotechnol ; 9: 660013, 2021.
Article in English | MEDLINE | ID: mdl-34222211

ABSTRACT

Finite element models are useful for investigating internal intervertebral disc (IVD) behaviours without using disruptive experimental techniques. Simplified geometries are commonly used to reduce computational time or because internal geometries cannot be acquired from CT scans. This study aimed to (1) investigate the effect of altered geometries both at endplates and the nucleus-anulus boundary on model response, and (2) to investigate model sensitivity to material and geometric inputs, and different modelling approaches (graduated or consistent fibre bundle angles and glued or cohesive inter-lamellar contact). Six models were developed from 9.4 T MRIs of bovine IVDs. Models had two variations of endplate geometry (a simple curved profile from the centre of the disc to the periphery, and precise geometry segmented from MRIs), and three variations of NP-AF boundary (linear, curved, and segmented). Models were subjected to axial compressive loading (to 0.86 mm at a strain rate of 0.1/s) and the effect on stiffness and strain distributions, and the sensitivity to modelling approaches was investigated. The model with the most complex geometry (segmented endplates, curved NP-AF boundary) was 3.1 times stiffer than the model with the simplest geometry (curved endplates, linear NP-AF boundary), although this difference may be exaggerated since segmenting the endplates in the complex geometry models resulted in a shorter average disc height. Peak strains were close to the endplates at locations of high curvature in the segmented endplate models which were not captured in the curved endplate models. Differences were also seen in sensitivity to material properties, graduated fibre angles, cohesive rather than glued inter-lamellar contact, and NP:AF ratios. These results show that FE modellers must take care to ensure geometries are realistic so that load is distributed and passes through IVDs accurately.

6.
JOR Spine ; 3(3): e21110, 2020 Sep.
Article in English | MEDLINE | ID: mdl-33015585

ABSTRACT

In vitro mechanical testing of intervertebral discs is crucial for basic science and pre-clinical testing. Generally, these tests aim to replicate in vivo conditions, but simplifications are necessary in specimen preparation and mechanical testing due to complexities in both structure and the loading conditions required to replicate in vivo conditions. There has been a growing interest in developing a consensus of testing protocols within the spine community to improve comparison of results between studies. The objective of this study was to perform axial compression experiments on bovine bone-disc-bone specimens at three institutions. No differences were observed between testing environment being air, with PBS soaked gauze, or a PBS bath (P > .206). A 100-fold increase in loading rate resulted in a small (2%) but significant increase in compressive mechanics (P < .017). A 7% difference in compressive stiffness between Labs B and C was eliminated when values were adjusted for test system compliance. Specimens tested at Lab A, however, were found to be stiffer than specimens from Lab B and C. Even after normalizing for disc geometry and adjusting for system compliance, an ∼35% difference was observed between UK based labs (B and C) and the USA based lab (A). Large differences in specimen stiffness may be due to genetic differences between breeds or in agricultural feed and use of growth hormones; highlighting significant challenges in comparing mechanics data across studies. This research provides a standardized test protocol for the comparison of spinal specimens and provides steps towards understanding how location and test set-up may affect biomechanical results.

7.
Policy Brief UCLA Cent Health Policy Res ; (PB2016-2): 1-8, 2016 Mar.
Article in English | MEDLINE | ID: mdl-27197310

ABSTRACT

Secondhand smoke is dangerous to a person's health at any level of exposure. Yet policies that prevent smoking are not in place for a majority of market-rate multi-unit housing complexes, according to a new survey of nearly 1,000 apartment dwellers in the city of Los Angeles. Approximately 37 percent of respondents reported that secondhand smoke had drifted into their apartments in the past year. Households with members of vulnerable populations, such as children or individuals with chronic conditions, are more likely to report smoke drifting from adjacent units. Four out of five respondents--including more than half of those who self-reported currently smoking--supported a smoke-free policy in common areas and/or individual units.


Subject(s)
Air Pollution, Indoor/adverse effects , Housing/legislation & jurisprudence , Tobacco Smoke Pollution/adverse effects , Adult , Air Pollution, Indoor/prevention & control , Child , Health Policy , Humans , Los Angeles/epidemiology , Public Housing , Smoking , Tobacco Smoke Pollution/prevention & control , United States , Vulnerable Populations
8.
Mt Sinai J Med ; 78(1): 49-57, 2011.
Article in English | MEDLINE | ID: mdl-21259262

ABSTRACT

As childhood obesity has reached epidemic proportions, it is critical to devise interventions that target the root causes of obesity and its risk factors. The two main components of childhood obesity are physical inactivity and improper nutrition, and it is becoming increasingly evident that the built environment can determine the level of exposure to these risk factors. Through a multidisciplinary literature review, we investigated the association between various built environment attributes and childhood obesity. We found that neighborhood features such as walkability/bikeability, mixed land use, accessible destinations, and transit increase resident physical activity; also that access to high-caloric foods and convenience stores increases risk of overweight and obesity, whereas the presence of neighborhood supermarkets and farmers' markets is associated with lower childhood body mass index and overweight status. It is evident that a child's built environment impacts his access to nutritious foods and physical activity. In order for children, as well as adults, to prevent onset of overweight or obesity, they need safe places to be active and local markets that offer affordable, healthy food options. Interventions that are designed to provide safe, walkable neighborhoods with access to necessary destinations will be effective in combating the epidemic of obesity.


Subject(s)
Environment , Obesity/etiology , Adolescent , Adult , Child , Child, Preschool , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...