Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 26
Filter
1.
Indian J Med Sci ; 65(2): 69-72, 2011 Feb.
Article in English | MEDLINE | ID: mdl-23196316

ABSTRACT

Ochrobactrum anthropi is an emerging pathogen increasingly affecting the immunocompromised host. Only four cases of infective endocarditis have been documented in literature. Therapeutic approach is a rising challenge as it is resistant to most of the currently available beta lactam antibiotics with the exception of carbapenems. We report a case of prosthetic valve endocarditis secondary to Ochrobactrum anthropi infection; the host was temporarily immunocompromised due to disseminated herpes zoster after surgery.


Subject(s)
Aortic Valve/microbiology , Carbapenems/therapeutic use , Endocarditis, Bacterial/microbiology , Gram-Negative Bacterial Infections/microbiology , Ochrobactrum anthropi/isolation & purification , Aged , Endocarditis, Bacterial/drug therapy , Gram-Negative Bacterial Infections/drug therapy , Humans , Male
2.
Catheter Cardiovasc Interv ; 74(5): 700-7, 2009 Nov 01.
Article in English | MEDLINE | ID: mdl-19496119

ABSTRACT

OBJECTIVES: The objective of this study is to analyze the clinical outcomes and treatment strategies of coronary wire perforations (WPs) in the era of heparin use compared to the era of bivalirudin use. BACKGROUND: Percutaneous coronary intervention (PCI) advances have led to progressive decrease in complications. Therefore, complex coronary lesions such as chronic total occlusions and calcified lesions are being attempted with stiff/hydrophilic wires with resultant higher incidence of coronary WP. METHODS: A single-center retrospective data analysis of coronary perforation (CP) for the last 4 years with review of coronary angiograms was done and WPs were identified. A simple classification scheme based on angiographic appearance of CP was made: Type I ("myocardial stain," with no frank dye extravasation) and type II ("myocardial fan," with dye extravasation to pericardial cavity or cardiac chambers). RESULTS: Overall incidence of CP was 0.49% (82/16,859). Of these 50 (61%) were caused by WP; 30 occurred with heparin use (Group A) and 20 with bivalirudin use (Group B). WPs always occurred in type B2/C lesions (100%) and commonly with use of hydrophilic guidewires (70%). Major adverse cardiac events and cardiac tamponade were frequent in group A (50%) and none in group B (0%); P < 0.01. All WP in group B responded to stopping anticoagulation and prolonged balloon inflation, while group A type II perforations frequently required additional interventions (pericardiocentesis, coil embolization). CONCLUSIONS: Cardiac tamponade and major adverse cardiac events from WPs were less frequent with bivalirudin use compared to heparin use. This beneficial effect of bivalirudin may be explained on the basis of its short half-life and reversible thrombin inhibition property. Therefore, bivalirudin may offer a safer alternative for anticoagulation in complex PCI.


Subject(s)
Angioplasty, Balloon, Coronary/adverse effects , Anticoagulants/adverse effects , Cardiac Tamponade/therapy , Coronary Artery Disease/therapy , Coronary Vessels/injuries , Heparin/adverse effects , Hirudins/adverse effects , Peptide Fragments/adverse effects , Wounds, Penetrating/therapy , Aged , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/mortality , Balloon Occlusion , Cardiac Tamponade/diagnostic imaging , Cardiac Tamponade/etiology , Cardiac Tamponade/mortality , Cineangiography , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Female , Heparin Antagonists/therapeutic use , Hospital Mortality , Humans , Male , Middle Aged , Myocardial Infarction/etiology , Pericardiocentesis , Recombinant Proteins/adverse effects , Registries , Retrospective Studies , Treatment Outcome , Wounds, Penetrating/diagnostic imaging , Wounds, Penetrating/etiology , Wounds, Penetrating/mortality
3.
Catheter Cardiovasc Interv ; 71(2): 185-90, 2008 Feb 01.
Article in English | MEDLINE | ID: mdl-18327835

ABSTRACT

OBJECTIVES: The aim of the present study was to study the outcome of coronary stenting in patients with symptomatic myocardial bridging refractory to standard medical therapy. BACKGROUND: Medical therapy constitutes the first line treatment for patients with symptomatic myocardial bridge, surgical correction may be offered to select patients with refractory symptoms. Limited data exists on the outcome of coronary stenting in this patient cohort. METHODS: Twenty-nine patients with symptoms of angina, documented myocardial ischemia and angiographically documented myocardial bridge of the left anterior descending artery (defined as [mt]50% systolic compression) were identified retrospectively. Seventeen (59%) patients responded to maximized medical therapy (mean age 51 +/- 16 years, range 29-80, 7 female) and 12 (41%) patients received coronary stents following a failed attempt of minimum 3 months of maximal medical therapy (mean age 49 +/- 15 years, range 32-76 years, 5 females). Medical therapy responders were compared with intracoronary stent group for recurrent severe angina, target vessel revascularization (TVR), myocardial infarction (MI), and death at follow-up. RESULTS: Intracoronary stents were placed in all patients successfully. The incidence of recurrent severe angina and TVR were significantly greater in the stent group (P = 0.04) while MI and death in two groups were similar at mean follow-up of 15 +/- 3 months. CONCLUSIONS: Coronary stent placement for medically refractory symptomatic myocardial bridge failed to relieve severe angina and is associated with high clinical restenosis and hence should be avoided.


Subject(s)
Adrenergic beta-Antagonists/therapeutic use , Calcium Channel Blockers/therapeutic use , Myocardial Bridging/drug therapy , Myocardial Bridging/therapy , Stents , Adult , Aged , Aged, 80 and over , Cineangiography , Coronary Restenosis/epidemiology , Drug-Eluting Stents , Female , Humans , Male , Middle Aged , Retreatment , Retrospective Studies , Treatment Failure
4.
J Invasive Cardiol ; 20(2): 67-72, 2008 Feb.
Article in English | MEDLINE | ID: mdl-18252970

ABSTRACT

OBJECTIVES: The objectives of the present study were to evaluate the feasibility and safety of implanting a prophylactic left ventricular (LV) assist device prior to high-risk percutaneous coronary intervention (PCI) and to assess the impact of suturemediated preclosure of the arteriotomy site on minimizing vascular complications. BACKGROUND: Patients with multivessel disease, left main coronary artery disease (LMCA) or left main equivalent and/or moderate-to-severe LV dysfunction with elevated LV end-diastolic pressure are at increased risk of complications during PCI. The TandemHeart (TH) is a nonpulsatile percutaneous transseptal ventricular assist device (PTVA) that offers vital temporary hemodynamic support during high-risk PCI. METHODS: Between April 2004 and November 2005, the TH was implanted in 20 patients undergoing high-risk PCI. Eight patients underwent unprotected LMCA stenting, and rotational atherectomy was used in 17 patients. Suture-mediated femoral artery preclosure was performed prior to inserting a large-bore arterial cannula. RESULTS: The TH was successfully implanted in all 20 patients. Mean LV ejection fraction of the study patients was 38 +/- 18%. Time-to-implantation of the TH, duration of hemodynamic support and mean flow of the TH device were 31 +/- 9 minutes, 74 +/- 40 minutes and 2.5 +/- 1.3 L/minute, respectively. At the end of PCI, the TH was removed in all cases and Perclose sutures were deployed in 18/20 (90%) patients. There was only 1 minor vascular complication, and the average length of stay was 2 +/- 1 days. Periprocedural and inhospital mortality was 0%. CONCLUSIONS: Implantation of the TH PTVA is safe and feasible in patients undergoing high-risk PCI with excellent hemodynamic support. Application of suture-mediated devices prior to large arteriotomies can significantly reduce the incidence of vascular complications.


Subject(s)
Angioplasty, Balloon, Coronary , Blood Vessel Prosthesis Implantation , Coronary Artery Disease/surgery , Heart-Assist Devices , Ventricular Dysfunction, Left/surgery , Aged , Coronary Artery Disease/complications , Coronary Restenosis/prevention & control , Feasibility Studies , Female , Humans , Male , Middle Aged , Risk Factors , Treatment Outcome , Ventricular Dysfunction, Left/etiology
5.
J Invasive Cardiol ; 19(11): E346-9, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17986736

ABSTRACT

Periprocedural hemodynamic stability is the cornerstone of success for complex percutaneous interventions. Percutaneous left ventricular assist devices (VSD) are increasingly being used to perform complex percutaneous coronary and non-coronary interventions. We report our experience in utilizing the TandemHeart, a percutaneous VSD, to successfully perform complex tandem procedures; balloon aortic valvuloplasty and angioplasty.


Subject(s)
Angioplasty, Balloon, Coronary , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation/methods , Heart-Assist Devices , Coronary Angiography , Humans , Male , Middle Aged , Ventricular Dysfunction, Left/surgery
6.
Echocardiography ; 24(10): 1105-7, 2007 Nov.
Article in English | MEDLINE | ID: mdl-18001368

ABSTRACT

We describe an adult patient in whom the valve of foramen ovale and its opening and closing movements were well visualized by live/real time three-dimensional transthoracic echocardiography.


Subject(s)
Echocardiography, Three-Dimensional/methods , Foramen Ovale/abnormalities , Heart Defects, Congenital/diagnostic imaging , Heart Valves/abnormalities , Adult , Diagnosis, Differential , Female , Foramen Ovale/diagnostic imaging , Humans
7.
J Invasive Cardiol ; 19(8): E226-9, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17712211

ABSTRACT

The TandemHeart is a recently-introduced percutaneous ventricular assist device that may be used for short-term hemodynamic support. Its utility has been shown for assisting the left ventricle in a variety of high-risk percutaneous interventions, in helping the left ventricle recover from myocarditis, in cardiomyopathies and in cardiogenic shock following acute coronary syndromes. Limited data exist on its applications in patients with right ventricular failure. We report our experience, possibly the first human case description, of a patient in cardiogenic shock secondary to severe pulmonary artery hypertension where the TandemHeart was used as a short-term hemodynamic support tool.


Subject(s)
Heart-Assist Devices , Hypertension, Pulmonary/complications , Shock, Cardiogenic/etiology , Shock, Cardiogenic/therapy , Adult , Cineangiography , Critical Illness/therapy , Echocardiography , Fatal Outcome , Female , Humans , Hypertension, Pulmonary/physiopathology , Pulmonary Artery/diagnostic imaging , Severity of Illness Index , Shock, Cardiogenic/diagnostic imaging
8.
Echocardiography ; 24(7): 760-7, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17651107

ABSTRACT

Twenty-one patients (mean age 47.5 years, 9 females) with left ventricular noncompaction (LVNC) diagnosed by both two-dimensional transthoracic echocardiography (2DTTE) and live/real time three-dimensional transthoracic echocardiography (3DTTE) were included in the study. Left ventricular (LV) mass was calculated with epicardial and endocardial border tracings first including the LV trabeculations and then excluding them. LV trabecular mass was then derived as the difference between the two measurements. This was done by 2DTTE using the modified biplane Simpson's method and by live/real time 3DTTE using the Tom Tec imaging system. The number of trabeculations arising from each segment of LV walls as well as the segmental distribution of trabeculations were also assessed by both 2DTTE and 3DTTE. The calculated LV trabecular mass by 3DTTE (mean 11.8 +/- 5.5 g) was significantly greater than 2DTTE (mean 7.3 +/- 4.3 g, P = 0.005). The total number of trabeculations assessed by 3DTTE (mean 11.2 +/- 3.3) was also significantly greater than 2DTTE (mean 3.76 +/- 1.2, P < 0.0001). The values for inter- and intraobserver variability were lower for 3DTTE than 2DTTE. In conclusion, both LV trabecular mass as well as the total number of trabeculations in patients with LVNC were significantly underestimated by 2DTTE as compared to 3DTTE.


Subject(s)
Echocardiography/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Outflow Obstruction/diagnostic imaging , Adult , Aged , Echocardiography, Three-Dimensional/methods , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
9.
J Invasive Cardiol ; 19(1): E5-8, 2007 Jan.
Article in English | MEDLINE | ID: mdl-17297193

ABSTRACT

TandemHeart is a recently-introduced percutaneous left ventricular assist device that can be used for hemodynamic support during high-risk interventional procedures in severely compromised patients. Angioplasty and stent placement in patients with coronary artery disease and high-risk coronary anatomy including the left main coronary artery have been described using this device. We report the first human case description of a high-risk percutaneous balloon aortic valvuloplasty for critical bicuspid aortic stenosis using the TandemHeart for periprocedural hemodynamic support. Also not previously reported is the use of bivaluridin as the periprocedural antithrombin agent during and after high-risk aortic valvuloplasty.


Subject(s)
Angioplasty, Balloon/methods , Aortic Valve Stenosis/therapy , Heart-Assist Devices , Peptide Fragments/therapeutic use , Anticoagulants/therapeutic use , Aortic Valve Stenosis/diagnostic imaging , Cardiac Catheterization , Echocardiography, Transesophageal , Follow-Up Studies , Hirudins , Humans , Intra-Aortic Balloon Pumping/methods , Male , Middle Aged , Recombinant Proteins/therapeutic use , Risk Assessment , Severity of Illness Index , Stroke Volume , Treatment Outcome
10.
Echocardiography ; 23(10): 872-9, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17069608

ABSTRACT

Tissue Doppler imaging (TDI) in 38 adult patients with pulmonary artery hypertension of varied etiology and normal left ventricular systolic function by two-dimensional transthoracic echocardiography showed significantly reduced peak systolic strain (SS) in all three segments of left ventricular free wall and ventricular septum and two of three segments of right ventricular free wall when compared to 29 adults with no clinical or echocardiographic evidence of heart disease and normal left and right ventricular systolic function. A similar reduction in peak diastolic strain (DS) was also noted in all three segments of left ventricular free wall and ventricular septum and one of three segments of right ventricular free wall. This reduction in strain indices in patients with pulmonary hypertension was noted irrespective of whether right ventricular systolic function was normal or reduced as assessed by two-dimensional transthoracic echocardiography. SS and DS rates also showed reductions in patients with pulmonary artery hypertension. Our study shows the potential value of TDI indices in identifying reduced regional left ventricular systolic and diastolic longitudinal function in patients with pulmonary artery hypertension and normal left ventricular systolic function by two-dimensional transthoracic echocardiography. This reduction in left ventricular function was noted in patients with both normal and reduced right ventricular systolic functions by two-dimensional echocardiography.


Subject(s)
Echocardiography, Doppler , Hypertension, Pulmonary/diagnostic imaging , Pulmonary Artery/diagnostic imaging , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Right/diagnostic imaging , Adult , Aged , Case-Control Studies , Diastole , Female , Humans , Hypertension, Pulmonary/physiopathology , Male , Middle Aged , Observer Variation , Pulmonary Artery/physiopathology , Pulmonary Wedge Pressure , Research Design , Severity of Illness Index , Stroke Volume , Systole , Ventricular Dysfunction, Left/physiopathology , Ventricular Dysfunction, Right/physiopathology
11.
Echocardiography ; 23(10): 880-3, 2006 Nov.
Article in English | MEDLINE | ID: mdl-17069609

ABSTRACT

The differential diagnosis of a cardiac valve mass includes fibroelastoma, myxoma, lipoma, Lambl's excrescences, thrombus, and vegetation. Fibroelastomas are extremely rare primary cardiac tumors. Their incidence is 0.00017-0.033% in autopsy series and 0.019% in clinical series identified on echocardiography. Although rare, fibroelastomas are the most common tumors affecting the cardiac valves with aortic, mitral, tricuspid, and pulmonary valves being involved in this order. In the current report we describe a case of pulmonary valve mass in which a confident prospective diagnosis of fibroelastoma could be made utilizing the technique of three-dimensional transthoracic echocardiography.


Subject(s)
Computer Systems , Echocardiography, Three-Dimensional , Fibroma/diagnostic imaging , Heart Neoplasms/diagnostic imaging , Pulmonary Valve/diagnostic imaging , Pulmonary Valve/pathology , Adult , Cardiac Surgical Procedures , Fibroma/surgery , Heart Neoplasms/surgery , Humans , Image Processing, Computer-Assisted , Male , Pulmonary Valve/surgery , Pulmonary Valve Insufficiency/diagnostic imaging , Pulmonary Valve Insufficiency/surgery
13.
Echocardiography ; 23(9): 793-800, 2006 Oct.
Article in English | MEDLINE | ID: mdl-16999702

ABSTRACT

We evaluated tricuspid regurgitation (TR) by multiple echocardiographic techniques in 93 consecutive patients who underwent standard two-dimensional (2D) and live three-dimensional (3D) transthoracic echocardiography (TTE). TR vena contracta (VC) area was obtained by 3D TTE by systematic and sequential cropping of the acquired 3D TTE dataset. Assessment of VC area by 3D TTE was compared to 2D TTE measurements of the ratio of TR regurgitant jet area to right atrial area (RJA/RAA), RJA alone, VC width, and calculated VC area. VC area from 3D TTE closely correlated with RJA/RAA and RJA alone as determined from 2D TTE measurements. Live 3D TTE color Doppler measurements of VC area can be used for quantitative assessment of TR and offer incremental value for quantification of particularly severe regurgitant lesions.


Subject(s)
Echocardiography, Doppler, Color , Echocardiography, Three-Dimensional , Tricuspid Valve Insufficiency/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Alabama , Female , Humans , Image Processing, Computer-Assisted , Linear Models , Male , Middle Aged , Observer Variation , Pulmonary Wedge Pressure , Sensitivity and Specificity , Severity of Illness Index , Stroke Volume , Tricuspid Valve Insufficiency/epidemiology , Tricuspid Valve Insufficiency/physiopathology , Ventricular Function, Right
14.
Echocardiography ; 23(9): 801-2, 2006 Oct.
Article in English | MEDLINE | ID: mdl-16999703

ABSTRACT

We report a 49-year-old morbidly obese female with a poor acoustic window in whom live/real time three-dimensional transthoracic echocardiography was able to make a confident diagnosis of cor triatriatum sinister. En face views of the membrane facilitated accurate assessment of the size and shape of the large nonobstructing opening in the membrane. Maximum dimensions of the opening were 3.06 x 1.03 cm and area was 2.3 cm(2).


Subject(s)
Computer Systems , Cor Triatriatum/diagnostic imaging , Cor Triatriatum/pathology , Echocardiography, Three-Dimensional , Female , Humans , Middle Aged
15.
Echocardiography ; 23(8): 704-6, 2006 Sep.
Article in English | MEDLINE | ID: mdl-16970725

ABSTRACT

We describe two adult patients with left ventricular noncompaction in whom live/real time three-dimensional transthoracic echocardiography (3DTTE) supplemented two-dimensional transthoracic echocardiography in making a definitive diagnosis of clots coexisting with trabeculations in the left ventricle. Mobility of clots and the presence of central echolucencies consistent with clot lysis were best demonstrated by 3DTTE and served to confidently differentiate clots from adjacent trabeculations.


Subject(s)
Cardiomyopathies/diagnostic imaging , Computer Systems , Echocardiography, Three-Dimensional , Thrombosis/diagnostic imaging , Adult , Cardiomyopathies/physiopathology , Fatal Outcome , Female , Heart Failure/diagnostic imaging , Heart Failure/etiology , Heart Failure/physiopathology , Heart Ventricles/diagnostic imaging , Heart Ventricles/pathology , Humans , Male , Middle Aged , Stroke Volume , Thrombosis/physiopathology , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/physiopathology
16.
Echocardiography ; 23(7): 598-608, 2006 Aug.
Article in English | MEDLINE | ID: mdl-16911337

ABSTRACT

We studied nine patients (five newborns and infants, two children, and two adults) with atrioventricular septal defects (four complete, one intermediate, and four partial) utilizing live/real time three-dimensional transthoracic echocardiography (3DTTE) and a 4-MHz matrix array transducer. In all patients, 3DTTE provided additional morphological and/or functional information as compared to standard two-dimensional transthoracic echocardiography (2DTTE). 3DTTE may be a useful supplement to 2DTTE in the assessment of atrioventricular septal defects.


Subject(s)
Echocardiography, Three-Dimensional/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Ventricular/diagnostic imaging , Adult , Aged , Child, Preschool , Diagnosis, Differential , Female , Humans , Infant , Infant, Newborn , Male , Reproducibility of Results , Severity of Illness Index
18.
Echocardiography ; 23(6): 513-8, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16839393

ABSTRACT

In this report, we present 34 patients in whom surgical intervention was undertaken for severe mitral insufficiency due to mitral valve prolapse (MVP). Location and severity of MVP and regurgitation were assessed preoperatively by live/real time three-dimensional transthoracic echocardiography and closely agreed with the surgical findings.


Subject(s)
Echocardiography, Three-Dimensional , Mitral Valve Prolapse/diagnostic imaging , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Sensitivity and Specificity
20.
Echocardiography ; 23(5): 421-7, 2006 May.
Article in English | MEDLINE | ID: mdl-16686630

ABSTRACT

In this report, we present 12 patients (range 14-76 years, mean 40 +/- 22.7 years) who underwent surgical repair of a ventricular septal defect (VSD). Location, size, and surrounding anatomy of the VSD were assessed prior to intervention in all patients with live/real time three-dimensional transthoracic echocardiography (3DTTE). In 9 patients, measurements of maximum dimension, circumference, and area by 3DTTE correlated well with the same measurements from intraoperative three-dimensional transesophageal echocardiographic (3DTEE) reconstruction. 3DTTE measurement of maximum dimension of VSDs also agreed well with maximum dimension by surgery in 10 patients. Live/real time 3DTTE accurately defined VSD location, size, and surrounding anatomy in all patients studied by us. VSD characterization by live 3DTTE agreed well with surgery descriptions and 3DTEE measurements.


Subject(s)
Computer Systems , Echocardiography, Doppler, Color , Echocardiography, Three-Dimensional , Heart Septal Defects, Ventricular/diagnostic imaging , Heart Septal Defects, Ventricular/pathology , Adolescent , Adult , Aged , Echocardiography, Transesophageal , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Observer Variation , Predictive Value of Tests , Reproducibility of Results
SELECTION OF CITATIONS
SEARCH DETAIL
...