Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Glob Infect Dis ; 14(1): 3-9, 2022.
Article in English | MEDLINE | ID: mdl-35418727

ABSTRACT

Introduction: Coronavirus disease 2019 (COVID-19) is a highly contagious disease transmitted by contact, droplets, and aerosols. Front line health-care workers (HCWs), particularly emergency physicians and acute care providers, are vulnerable to being exposed while treating their sick patients. Despite appropriate personal protective equipment use, HCW gets infected, suggesting the need for multiple layers of protection such as barrier devices. Methods: We aimed to determine the effectiveness of our novel "Resuscitation Cover All"(RCA) in reducing the exposure of HCW to simulated respiratory particles and its feasibility during cardio pulmonary resuscitation (CPR). This was a pilot simulation-based study. Five CPR simulation sessions were performed in Standard and RCA protocols, individually. Exposures through contact, droplets, and aerosols were simulated using a standardized volume of liquid detergent. Under Wood's lamp illumination, exposures of participants were compared between the protocols. Rate and depth of chest compressions, time taken to intubate, interruptions in CPR, and first-pass success were analyzed. Results: Overall mean exposure in standard protocol was 4950.4 ± 1461.6 (95%confidence interval [CI]:3135.7-6765.2) sq.pixels and RCA protocol was 2203.6 ± 1499.0 (95%CI: 342.4-4064.9) sq.pixels (P = 0.019). In standard, chest compressor had the highest exposure of 3066.6 ± 1419.2 (95%CI: 2051.3-4081.9) sq.pixels followed by defibrillator assistant 1166.4 ± 767.4 (95%CI: 617.4-1715.4) sq.pixels. Chest compressor of RCA had reduced exposure compared to that of standard (P < 0.001). Hands were the most frequently exposed body part. Airway manager of RCA had no exposure over head and neck in any session. No significant difference in CPR performance metrics was observed. Conclusion: This pilot simulation-based study shows that the novel RCA device could minimize the exposure of HCW to simulated respiratory particles during CPR. Also, it might not alter the high-quality CPR performance metrics. We need more real-life evidence.

3.
Indian J Crit Care Med ; 21(6): 404-407, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28701849

ABSTRACT

Survival following trachea-esophageal transection is uncommon. Establishing a secure airway has the highest priority in trauma management. Airway management is a unique and a defining element to the specialty of emergency medicine. There is no doubt regarding the significance of establishing a patent airway in the critically ill patient in the emergency department. Cannot intubate and cannot ventilate situation is a nightmare to all emergency physicians. The most important take-home message from this case report is that every Emergency physician should have the ability to predict "difficult airway" and recognize "failed airway" very early and be skilled in performing rescue techniques when routine oral-tracheal intubation fails. Any delay at any step in the "failed airway" management algorithm may not save the critically ill dying patient. Here, we report a case of blunt trauma following high-velocity road traffic accident, presenting in the peri-arrest state, in whom we noticed "failed airway" which turned out to be due to complete tracheal transection. In our patient, although we had secured the airway immediately, he had already sustained hypoxic brain damage. This scenario emphasizes the importance of prehospital care in developing countries.

SELECTION OF CITATIONS
SEARCH DETAIL
...