Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
A A Pract ; 16(5): e01586, 2022 May 01.
Article in English | MEDLINE | ID: mdl-35605173

ABSTRACT

One-lung ventilation (OLV) can be accomplished utilizing a double-lumen tube (DLT) and an endobronchial blocker (EBB) or intentionally placing a standard endotracheal tube (ETT) into a mainstem bronchus. However, secondary options must be available should the primary method fail. We present a case where an EBB and a fiberoptic bronchoscope (FOB) were successfully passed through a left-sided DLT to reestablish right-lung isolation after the DLT bronchial cuff was surgically damaged. We advocate competency in placing both DLTs and EBBs, as well as having EBBs readily accessible as a secondary isolation method during OLV.


Subject(s)
One-Lung Ventilation , Bronchi , Bronchoscopy , Humans , Intubation, Intratracheal , Lung
SELECTION OF CITATIONS
SEARCH DETAIL
...