Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Bioprocess Biosyst Eng ; 46(2): 183-193, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36437376

ABSTRACT

We investigated the capacity of water hyacinth leaves (LEC) to biosorb 75 mg/L acid red 27 (AR27) in a continuous system comprising 30 successive biosorption/desorption cycles in a packed-bed column at pH 2.0 and 56.5 L/m2·h volumetric flux. Using 0.025 M NaHCO3 eluent at 113 L/m2·h volumetric flux, all the dye was desorbed (100% desorption efficiency) from the loaded LEC biomass within 5-6 h. The same biosorbent was used for 147.5 consecutive days. The AR27 biosorption capacity, breakthrough time, and exhaustion time decreased from 69.4 to 34.5 mg/g, 74.81 to 14.1 h, and 101.1 to 34.1 h, respectively, and the critical bed height increased from 1.04 to 2.35 cm, as the number of biosorption/desorption cycles increased from 1 to 30. LEC life factor based on biosorption capacity predicted that the packed bed would be exhausted after 51.95 cycles. LEC is a promising biosorbent for bioremediation of AR27-laden wastewaters.


Subject(s)
Eichhornia , Water Pollutants, Chemical , Amaranth Dye , Wastewater , Adsorption , Hydrogen-Ion Concentration , Kinetics , Biomass
2.
Sci Rep ; 11(1): 18413, 2021 09 16.
Article in English | MEDLINE | ID: mdl-34531491

ABSTRACT

In this work, the biosorption behavior of acid red 27 (AR27) dye using Eichhornia crassipes leaves (LECs) in a packed-bed column was investigated by varying relevant operational parameters and assessment of mathematical models. Results showed that the zero-charge point of LECs was 2.37 and that optima pH and volumetric flux of the influent solution for AR27 biosorption were 2.0 and [Formula: see text], respectively. The maximum specific and volumetric biosorption capacities were observed at influent AR27 concentrations and with LEC bed heights ranging between 50 and 400 mg/L and 2 and 8 cm, respectively. It was also found that if LEC bed height was increased and volumetric flux and AR27 concentration of the influent solution decreased, service and saturation time increased. Modeling results revealed that the Thomas, bed depth service time, Yoon-Nelson, dose-response, and logistic models accurately described the dynamic performance of the packed-bed column in terms of pH, AR27 concentration, and volumetric flux of influent AR27 solution, as well as that of LEC bed height. The findings revealed that LECs exhibited remarkable potential for the biosorption of AR27 from aqueous solutions in a packed-bed column and could potentially be useful for the treatment of AR27-laden wastewater.

SELECTION OF CITATIONS
SEARCH DETAIL
...