Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Curr Rev Musculoskelet Med ; 17(7): 247-257, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38668940

ABSTRACT

PURPOSE OF REVIEW: Arthroscopy has become increasingly popular for a addressing a wide variety of shoulder pathology. However, despite increasing interest, there is still much uncertainty and variability amongst providers regarding optimal post-operative rehabilitation. This review provides an overview of the evidence underlying common rehab protocols used following arthroscopic interventions for rotator cuff disease, shoulder instability, superior labral anterior to posterior (SLAP) tears and adhesive capsulitis. RECENT FINDINGS: For small and medium sized rotator cuff tears, early motion protocols do not seem to affect healing or retear rates, however there is no difference with regards to long term functional outcomes when compared to standard motion protocols. For larger tears (> 3 cm), early active motion may be associated with impaired tendon integrity. Early range of motion following arthroscopic Bankart repair has not been shown to increase rate of recurrence, however the data on return to sport requires more granularity to effectively guide care. Further research needs to be done to compare rehab protocols following SLAP repair and arthroscopic capsular release. Rehabilitation protocols following rotator cuff surgery and anterior shoulder stabilization have garnered the most research interest. However, there is still a need for larger higher-level studies examining the long-term effects of different rehab protocols. Regarding the arthroscopic management of other types of shoulder instability, SLAP tears and adhesive capsulitis, there is paucity of high-quality evidence. This knowledge gap likely underpins the variability in different rehab protocols seen in clinical practice, highlighting the need for more research.

2.
J Vis Exp ; (205)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38497634

ABSTRACT

Tendinopathy is a chronic tendon condition that results in pain and loss of function and is caused by repeated overload of the tendon and limited recovery time. This protocol describes a testing system that cyclically applies mechanical loads via passive dorsiflexion to the rat Achilles tendon. The custom-written code consists of pre- and post-cyclic loading measurements to assess the effects of the loading protocol along with the feedback control-based cyclic fatigue loading regimen. We used 25 Sprague-Dawley rats for this study, with 5 rats per group receiving either 500, 1,000, 2,000, 3,600, or 7,200 cycles of fatigue loads. The percentage differences between the pre- and post-cyclic loading measurements of the hysteresis, peak stress, and loading and unloading moduli were calculated. The results demonstrate that the system can induce varying degrees of damage to the Achilles tendon based on the number of loads applied. This system offers an innovative approach to apply quantified and physiological varying degrees of cyclic loads to the Achilles tendon for an in vivo model of fatigue-induced overuse tendon injury.


Subject(s)
Achilles Tendon , Tendinopathy , Animals , Rats , Rats, Sprague-Dawley , Ankle , Culture , Tendinopathy/etiology
3.
Front Bioeng Biotechnol ; 12: 1327094, 2024.
Article in English | MEDLINE | ID: mdl-38515627

ABSTRACT

Introduction: Tendinopathy is a degenerative condition resulting from tendons experiencing abnormal levels of multi-scale damage over time, impairing their ability to repair. However, the damage markers associated with the initiation of tendinopathy are poorly understood, as the disease is largely characterized by end-stage clinical phenotypes. Thus, this study aimed to evaluate the acute tendon responses to successive fatigue bouts of tendon overload using an in vivo passive ankle dorsiflexion system. Methods: Sprague Dawley female rats underwent fatigue overloading to their Achilles tendons for 1, 2, or 3 loading bouts, with two days of rest in between each bout. Mechanical, structural, and biological assays were performed on tendon samples to evaluate the innate acute healing response to overload injuries. Results: Here, we show that fatigue overloading significantly reduces in vivo functional and mechanical properties, with reductions in hysteresis, peak stress, and loading and unloading moduli. Multi-scale structural damage on cellular, fibril, and fiber levels demonstrated accumulated micro-damage that may have induced a reparative response to successive loading bouts. The acute healing response resulted in alterations in matrix turnover and early inflammatory upregulations associated with matrix remodeling and acute responses to injuries. Discussion: This work demonstrates accumulated damage and acute changes to the tendon healing response caused by successive bouts of in vivo fatigue overloads. These results provide the avenue for future investigations of long-term evaluations of tendon overload in the context of tendinopathy.

4.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 243-256, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38258962

ABSTRACT

PURPOSE: The addition of the remplissage procedure to an arthroscopic Bankart procedure has been shown to improve clinical outcomes, yet at the expense of potentially decreasing shoulder range of motion. The purpose of this study was to assess recurrent instability, range of motion, functional outcomes and rates of return to sport outcomes in patients undergoing an isolated arthroscopic Bankart repair compared to those undergoing arthroscopic Bankart repair in addition to the remplissage procedure. METHODS: According to the Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines, a search was conducted using three databases (MEDLINE/OVID, EMBASE and PubMed). Retrieved studies were screened based on predefined inclusion and exclusion criteria for comparative studies. Data were extracted and meta-analysis performed using a random-effects model. RESULTS: A total of 16 studies (13 level III studies, 2 level II studies and 1 level I) were included with a total of 507 and 704 patients in the Bankart plus remplissage and isolated Bankart repair groups, respectively. No studies reported glenoid bone loss of >20% with the least percentage of glenoid bone loss reported among studies being <1%. There was a significantly increased rate of recurrent dislocations (odds ratio [OR] = 4.22, 95% confidence interval [CI]: 2.380-7.48, p < 0.00001) and revision procedures (OR = 3.36, 95% CI: 1.52-7.41, p = 0.003) in the isolated Bankart repair group compared to the Bankart plus remplissage group. Additionally, there were no significant differences between groups in terms of external rotation at side (n.s.), in abduction (n.s.) or at forward flexion (n.s.) at final follow-up. Furthermore, return to preinjury level of sport favoured the Bankart plus remplissage group (OR = 0.54, 95% CI: 0.35-0.85, p = 0.007). CONCLUSION: Patients undergoing arthroscopic Bankart plus remplissage for anterior shoulder instability have lower rates of recurrent instability, higher rates of return to sport, and no significant difference in range of motion at final follow-up when compared to an isolated arthroscopic Bankart repair. Further large, prospective studies are needed to further determine which patients and degree of bone loss would benefit most from augmentation with the remplissage procedure. LEVEL OF EVIDENCE: Level III.


Subject(s)
Bankart Lesions , Joint Instability , Shoulder Dislocation , Shoulder Joint , Humans , Shoulder Joint/surgery , Shoulder Dislocation/surgery , Joint Instability/surgery , Shoulder , Arthroscopy/methods , Range of Motion, Articular , Recurrence , Bankart Lesions/surgery , Retrospective Studies
5.
J Biomech ; 156: 111664, 2023 07.
Article in English | MEDLINE | ID: mdl-37302164

ABSTRACT

Tendinopathy is thought to be caused by repeated overload of the tendon with insufficient recovery time, leading to an inadequate healing response and incomplete recovery of preinjury material strength and function. The etiology of tendinopathy induced by mechanical load is being explored with a variety of mechanical load scenarios in small animals. This study establishes a testing system that applies passive ankle dorsiflexion to a rat hindlimb, estimates the force applied to the tendon during cyclic loading and enables the assessment of subsequent structural and biological changes. We demonstrated that the system had no drift in the applied angle, and the registered maximum angle and torque inputs and outputs were consistent between tests. We showed that cyclic loading decreased hysteresis and loading and unloading moduli with increasing cycles applied to the tendon. Histology showed gross changes to tendon structure. This work establishes a system for passively loading the rat Achilles tendon in-vivo in a physiological manner, facilitating future studies that will explore how mechanics, structure, and biology are altered by mechanical repetitive loading.


Subject(s)
Achilles Tendon , Tendinopathy , Rats , Animals , Achilles Tendon/physiology , Ankle , Ankle Joint/physiology , Mechanical Phenomena
6.
BMC Musculoskelet Disord ; 24(1): 105, 2023 Feb 07.
Article in English | MEDLINE | ID: mdl-36750786

ABSTRACT

BACKGROUND: The current understanding of glenohumeral joint stability is defined by active restrictions and passive stabilizers including naturally-occurring negative intraarticular pressure. Cadaveric specimens have been used to evaluate the role of intraarticular pressure on joint stability, although, while the shoulder's negative intraarticular pressure is universally acknowledged, it has been inconsistently accounted for. HYPOTHESIS: During continuous, passive humeral abduction, releasing the native intraarticular pressure increases joint translation, and restoring this pressure decreases joint translations. STUDY DESIGN: Descriptive Laboratory Study. METHODS: A validated shoulder testing system was used to passively abduct the humerus in the scapular plane and measure joint translations for seven (n = 7) cadaveric specimens. The pressure within the glenohumeral joint was measured via a 25-gauge needle during passive abduction of the arm, which was released and subsequently restored. During motion, the rotator cuff muscles were loaded using stepper motors in a force feedback loop and electromagnetic sensors were used to continuously measure the position of the humerus and scapula. Joint translation was defined according to the instant center of rotation of the glenohumeral head according to the recommendations by the International Society of Biomechanics. RESULTS: Area under the translation versus abduction angle curve suggests that releasing the pressure within the capsule results in significantly less posterior translation of the glenohumeral head as compared to intact (85-90˚, p < 0.05). Posterior and superior translations were reduced after 70˚ of abduction when the pressure within the joint was restored. CONCLUSION: With our testing system employing a smooth continuous passive motion, we were able to show that releasing intraarticular pressure does not have a major effect on the path of humeral head motion during glenohumeral abduction. However, both violating the capsule and restoring intraarticular pressure after releasing alter glenohumeral translations. Future studies should study the effect of simultaneous external rotation and abduction on the relationship between joint motion and IAP, especially in higher degrees of abduction. CLINICAL RELEVANCE: Thoroughly simulating the glenohumeral joint environment in the cadaveric setting may strengthen the conclusions that can be translated from this setting to the clinic.


Subject(s)
Shoulder Joint , Shoulder , Humans , Biomechanical Phenomena , Shoulder Joint/physiology , Humeral Head , Range of Motion, Articular/physiology , Cadaver
7.
Ann Biomed Eng ; 51(5): 1002-1013, 2023 May.
Article in English | MEDLINE | ID: mdl-36469168

ABSTRACT

Continuum mechanics-based finite element models of the shoulder aim to quantify the mechanical environment of the joint to aid in clinical decision-making for rotator cuff injury and disease. These models allow for the evaluation of the internal loading of the shoulder, which cannot be measured in-vivo. This study uses human cadaveric rotator cuff samples with surface tendon strain estimates, to validate a heterogeneous finite element model of the supraspinatus-infraspinatus complex during various load configurations. The computational model was considered validated when the absolute difference in average maximum principal strain for the articular and bursal sides for each load condition estimated by the model was no greater than 3% compared to that measured in the biomechanical study. The model can predict the strains for varying infraspinatus loads allowing for the study of load sharing between these two tightly coordinated tendons. The future goal is to use the modularity of this validated model to study the initiation and propagation of rotator cuff tear and other rotator cuff pathologies to ultimately improve care for rotator cuff tear patients.


Subject(s)
Rotator Cuff Injuries , Shoulder Joint , Humans , Rotator Cuff , Finite Element Analysis , Biomechanical Phenomena
8.
BMC Musculoskelet Disord ; 23(1): 139, 2022 Feb 11.
Article in English | MEDLINE | ID: mdl-35148741

ABSTRACT

OBJECTIVE: Medial patellofemoral ligament (MPFL) injury occurs in the majority of the cases of acute patellar dislocation. The role of concomitant lateral retinaculum release with MPFL reconstruction is not clearly understood. Even though the lateral retinaculum plays a role in both medial and lateral patellofemoral joint stability in MPFL intact knees, studies have shown mixed clinical outcomes following its release during MPFL reconstruction surgery. Better understanding of the biomechanical effects of the release of the lateral retinaculum during MPFL reconstruction is warranted. We hypothesize that performing a lateral release concurrent with MPFL reconstruction will disrupt the patellofemoral joint biomechanics and result in lateral patellar instability. METHODS: A previously developed and validated finite element (FE) model of the patellofemoral joint was used to understand the effect of lateral retinaculum release following MPFL reconstruction. Contact pressure (CP), contact area (CA) and lateral patellar displacement were recorded. abstract. RESULTS: FE modeling and analysis demonstrated that lateral retinacular release following MPFL reconstruction with tibial tuberosity-tibial groove distance (TT-TG) of 12 mm resulted in a 39% decrease in CP, 44% decrease in CA and a 20% increase in lateral patellar displacement when compared to a knee with an intact MPFL. In addition, there was a 45% decrease in CP, 44% decrease in CA and a 21% increase in lateral displacement when compared to a knee that only had an MPFL reconstruction. CONCLUSION: This FE-based analysis exhibits that concomitant lateral retinaculum release with MPFL reconstruction results in decreased PF CA, CP and increased lateral patellar displacement with increased knee flexion, which may increase the risk of patellar instability.


Subject(s)
Joint Instability , Patellar Dislocation , Patellofemoral Joint , Humans , Joint Instability/surgery , Ligaments, Articular , Patella , Patellar Dislocation/diagnostic imaging , Patellar Dislocation/surgery , Patellofemoral Joint/diagnostic imaging , Patellofemoral Joint/surgery
9.
Arthroscopy ; 38(3): 953-964, 2022 03.
Article in English | MEDLINE | ID: mdl-34411682

ABSTRACT

PURPOSE: The purpose of this study was to develop and validate a finite element (FE) model of the patellofemoral (PF) joint to characterize patellofemoral instability, and to highlight the effect of lateral retinacular release in combination with tibial tuberosity transfer with respect to contact pressures (CP), contact area (CA), and kinematics during knee flexion. METHODS: A comprehensive, dynamic FE model of the knee joint was developed and validated through parametric comparison of PF kinematics, CP, and CA between FE simulations and in vitro, cadaveric experiments. Using this FE model, we characterized the effect of patellar instability, lateral retinacular release (LR), and tibial tuberosity transfer (TTT) in the setting of medial patellofemoral ligament injury during knee flexion. RESULTS: There was a high level of agreement in CP, CA, lateral patellar displacement, anterior patellar displacement, and superior patellar displacement between the FE model and the in vitro data (P values 0.19, 0.16, 0.81, 0.10, and 0.36, respectively). Instability conditions demonstrated the greatest CP compared to all of the other conditions. During all degrees of flexion, TTT and concomitant lateral release (TTT + LR) decreased CP significantly. TTT alone shows a consistently lower CA compared to nonrelease conditions with subsequent lateral release further decreasing CA. CONCLUSIONS: The results of this study demonstrate that the FE model described reliably simulates PF kinematics and CP within 1 SD in uncomplicated cadaveric specimens. The FE model is able to show that tibial tubercle transfer in combination with lateral retinacular release markedly decreases patellofemoral CP and CA and increases lateral patellar displacement that may decrease bony stabilization of the patella within the trochlear groove and promote lateral patellar instability. CLINICAL RELEVANCE: The goal of surgical correction for patellar instability focuses on reestablishing normal PF kinematics. By developing an FE model that can demonstrate patient PF kinematics and the results of different surgical approaches, surgeons may tailor their treatment to the best possible outcome. Of the surgical approaches that have been described, the biomechanical effects of the combination of TTT with lateral retinacular release have not been studied. Thus, the FE analysis will help shed light on the effect of the combination of TTT with lateral retinacular release on PF kinematics.


Subject(s)
Joint Instability , Patellofemoral Joint , Biomechanical Phenomena , Cadaver , Humans , Joint Instability/surgery , Models, Anatomic , Patella/surgery , Patellofemoral Joint/surgery , Tibia/surgery
10.
Acta Biomater ; 134: 43-56, 2021 10 15.
Article in English | MEDLINE | ID: mdl-34325074

ABSTRACT

Tendinopathy is a debilitating disease that causes as much as 30% of all musculoskeletal consultations. Existing treatments for tendinopathy have variable efficacy, possibly due to incomplete characterization of the underlying pathophysiology. Mechanical load can have both beneficial and detrimental effects on tendon, as the overall tendon response depends on the degree, frequency, timing, and magnitude of the load. The clinical continuum model of tendinopathy offers insight into the late stages of tendinopathy, but it does not capture the subclinical tendinopathic changes that begin before pain or loss of function. Small animal models that use high tendon loading to mimic human tendinopathy may be able to fill this knowledge gap. The goal of this review is to summarize the insights from in-vivo animal studies of mechanically-induced tendinopathy and higher loading regimens into the mechanical, microstructural, and biological features that help characterize the continuum between normal tendon and tendinopathy. STATEMENT OF SIGNIFICANCE: This review summarizes the insights gained from in-vivo animal studies of mechanically-induced tendinopathy by evaluating the effect high loading regimens have on the mechanical, structural, and biological features of tendinopathy. A better understanding of the interplay between these realms could lead to improved patient management, especially in the presence of painful tendon.


Subject(s)
Tendinopathy , Tendons , Animals , Humans
11.
Am J Sports Med ; 48(9): 2252-2259, 2020 07.
Article in English | MEDLINE | ID: mdl-32551965

ABSTRACT

BACKGROUND: There is a lack of evidence regarding the optimum extensor-sided fixation method for medial patellofemoral ligament (MPFL) reconstruction. There is increased interest in avoiding patellar drilling via soft tissue-only fixation to the distal quadriceps, thus reconstructing the medial quadriceps tendon-femoral ligament (MQTFL). The biomechanical implications of differing extensor-sided fixation constructs remain unknown. HYPOTHESIS: The null hypothesis was there would be no differences between traditional MPFL reconstruction and MQTFL reconstruction with respect to resistance to lateral translation, patellar position, or patellofemoral contact pressures. STUDY DESIGN: Controlled laboratory study. METHODS: Nine adult knee specimens were mounted on a jig that applied static, physiologic loads to the quadriceps tendons. Patellar position and orientation, knee flexion angle, and patellofemoral pressure were recorded at 8 different flexion angles between 0° and 110°. Additionally, a lateral patellar excursion test was conducted wherein a load was applied directly to the patella in the lateral direction with the knee at 30° of flexion and subjected to 2-N quadriceps loads. Testing was conducted under 4 conditions: intact, transected MPFL, MQTFL reconstruction, and MPFL reconstruction. For MQTFL reconstruction, the surgical technique established by Fulkerson was employed. For MPFL reconstruction, a traditional technique was utilized. RESULTS: The patellar excursion test showed no significant difference between the MQTFL and intact states with respect to lateral translation. MPFL reconstruction led to significantly less lateral translation (P < .05) than all other states. There were no significant differences between MPFL and MQTFL reconstructions with respect to peak patellofemoral contact pressure. MPFL and MQTFL reconstructions both resulted in increased internal rotation of the patella with the knee in full extension. CONCLUSION: Soft tissue-only extensor-sided fixation to the distal quadriceps (MQTFL) during patella stabilization appears to re-create native stability in this time 0 cadaver model. Fixation to the patella (MPFL) was associated with increased resistance to lateral translation. CLINICAL RELEVANCE: Evolving anatomic knowledge and concern for patellar fracture has led to increased interest in MQTFL reconstruction. Both MQTFL and MPFL reconstructions restored patellofemoral stability to lateral translation without increasing contact pressures under appropriate graft tensioning, with MQTFL more closely restoring native resistance to lateral translation at the time of surgery.


Subject(s)
Ligaments, Articular/surgery , Patellofemoral Joint , Tendons/surgery , Aged , Biomechanical Phenomena , Cadaver , Humans , Male , Middle Aged , Patella , Patellofemoral Joint/surgery
12.
J Biomech ; 105: 109798, 2020 05 22.
Article in English | MEDLINE | ID: mdl-32423544

ABSTRACT

Healthy shoulder function requires the coordination of the rotator cuff muscles to maintain the humeral head's position in the glenoid. While glenohumeral stability has been studied in various settings, few studies have characterized the effect of dynamic rotator cuff muscle loading on glenohumeral translation during shoulder motion. We hypothesize that dynamic rotator cuff muscle activation decreases joint translation during continuous passive abduction of the humerus in a cadaveric model of scapular plane glenohumeral abduction. The effect of different rotator cuff muscle activity on glenohumeral translation was assessed using a validated shoulder testing system. The Dynamic Load profile is a novel approach, based on musculoskeletal modeling of human subject motion. Passive humeral elevation in the scapular plane was applied via the testing system arm, while the rotator cuff muscles were activated according to the specified force profiles using stepper motors and a proportional control feedback loop. Glenohumeral translation was defined according to the International Society of Biomechanics. The Dynamic load profile minimized superior translation of the humeral head relative to the conventional loading profiles. The total magnitude of translation was not significantly different (0.805) among the loading profiles suggesting that the compressive forces from the rotator cuff primarily alter the direction of humeral head translation, not the magnitude. Rotator cuff muscle loading is an important element of cadaveric shoulder studies that must be considered to accurately simulate glenohumeral motion. A rotator cuff muscle activity profile based on human subject muscle activity reduces superior glenohumeral translation when compared to previous RC loading profiles.


Subject(s)
Rotator Cuff Injuries , Shoulder Joint , Biomechanical Phenomena , Cadaver , Humans , Range of Motion, Articular , Rotator Cuff
13.
J Biomech ; 82: 280-290, 2019 01 03.
Article in English | MEDLINE | ID: mdl-30514628

ABSTRACT

BACKGROUND: Numerous biomechanical studies have addressed normal shoulder function and the factors that affect it. While these investigations include a mix of in-vivo clinical reports, ex-vivo cadaveric studies, and computer-based simulations, each has its own strengths and limitations. A robust methodology is essential in cadaveric work but does not always come easily. Precise quantitative measurements are difficult in in-vivo studies, and simulation studies require validation steps. This review focuses on ex-vivo cadaveric studies to emphasize the best research methodologies available to simulate physiologically and clinically relevant shoulder motion. METHODS: A PubMed and Web of Science search was conducted in March 2017 (and updated in May 2018) to identify the cadaveric studies focused on the shoulder and its function. The key words for this search included rotator cuff (RC) injuries, RC surgery, and their synonyms. The protocol of the study was registered on PROSPERO and is accessible at CRD42017068873. RESULTS: Thirty one studies consisting of 167 specimens with various biomechanical methods met our inclusion criteria. All studies were level V cadaveric studies. Cadaveric biomechanical models are widely used to study shoulder instability and RC repair. These models are commonly limited to the glenohumeral joint by a fixed scapula, passively and discretely move the humerus, and statically load the RC without regard for the integrity of the glenohumeral capsule. CONCLUSION: All studies captured in this review evaluated shoulder biomechanics. Recent studies in patients suggest that some assumptions made in this space may not fully characterize motion of the human shoulder. With reproducible scapular positioning, dynamic RC activation, and preservation of glenohumeral capsule integrity, cadaveric studies can facilitate proper validation for simulation models and broaden our understanding of the shoulder environment during motion in healthy and disease states.


Subject(s)
Mechanical Phenomena , Rotator Cuff/physiopathology , Rotator Cuff/surgery , Shoulder/physiopathology , Biomechanical Phenomena , Cadaver , Humans
14.
BMJ Open Sport Exerc Med ; 4(1): e000212, 2018.
Article in English | MEDLINE | ID: mdl-29682310

ABSTRACT

OBJECTIVE: To review existing biomechanical and clinical evidence regarding postoperative weight-bearing and range of motion restrictions for patients following meniscal repair surgery. METHODS AND DATA SOURCES: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guideline, we searched MEDLINE using following search strategy: (((("Weight-Bearing/physiology"[Mesh]) OR "Range of Motion, Articular"[Mesh]) OR "Rehabilitation"[Mesh])) AND ("Menisci, Tibial"[Mesh]). Additional articles were derived from previous reviews. Eligible studies were published in English and reported a rehabilitation protocol following meniscal repair on human. We summarised rehabilitation protocols and patients' outcome among original studies. RESULTS: Seventeen clinical studies were included in this systematic review. There was wide variation in rehabilitation protocols among clinical studies. Biomechanical evidence from small cadaveric studies suggests that higher degrees of knee flexion and weight-bearing may be safe following meniscal repair and may not compromise the repair. An accelerated protocol with immediate weight-bearing at tolerance and early motion to non-weight-bearing with immobilising up to 6 weeks postoperatively is reported. Accelerated rehabilitation protocols are not associated with higher failure rates following meniscal repair. CONCLUSIONS: There is a lack of consensus regarding the optimal postoperative protocol following meniscal repair. Small clinical studies support rehabilitation protocols that allow early motion. Additional studies are needed to better clarify the interplay between tear type, repair method and optimal rehabilitation protocol.

15.
World J Orthop ; 8(5): 379-384, 2017 May 18.
Article in English | MEDLINE | ID: mdl-28567341

ABSTRACT

AIM: To describe an approach to anterior cruciate ligament (ACL) reconstruction using autologous hamstring by drilling via the anteromedial portal in the presence of an intramedullary (IM) femoral nail. METHODS: Once preoperative imagining has characterized the proposed location of the femoral tunnel preparations are made to remove all of the hardware (locking bolts and IM nail). A diagnostic arthroscopy is performed in the usual fashion addressing all intra-articular pathology. The ACL remnant and lateral wall soft tissues are removed from the intercondylar, to provide adequate visualization of the ACL footprint. Femoral tunnel placement is performed using a transportal ACL guide with desired offset and the knee flexed to 2.09 rad. The Beath pin is placed through the guide starting at the ACL's anatomic footprint using arthroscopic visualization and/or fluoroscopic guidance. If resistance is met while placing the Beath pin, the arthroscopy should be discontinued and the obstructing hardware should be removed under fluoroscopic guidance. When the Beath pin is successfully placed through the lateral femur, it is overdrilled with a 4.5 mm Endobutton drill. If the Endobutton drill is obstructed, the obstructing hardware should be removed under fluoroscopic guidance. In this case, the obstruction is more likely during Endobutton drilling due to its larger diameter and increased rigidity compared to the Beath pin. The femoral tunnel is then drilled using a best approximation of the graft's outer diameter. We recommend at least 7 mm diameter to minimize the risk of graft failure. Autologous hamstring grafts are generally between 6.8 and 8.6 mm in diameter. After reaming, the knee is flexed to 1.57 rad, the arthroscope placed through the anteromedial portal to confirm the femoral tunnel position, referencing the posterior wall and lateral cortex. For a quadrupled hamstring graft, the gracilis and semitendinosus tendons are then harvested in the standard fashion. The tendons are whip stitched, quadrupled and shaped to match the diameter of the prepared femoral tunnel. If the diameter of the patient's autologous hamstring graft is insufficient to fill the prepared femoral tunnel, the autograft may be supplemented with an allograft. The remainder of the reconstruction is performed according to surgeon preference. RESULTS: The presence of retained hardware presents a challenge for surgeons treating patients with knee instability. In cruciate ligament reconstruction, distal femoral and proximal tibial implants hardware may confound tunnel placement, making removal of hardware necessary, unless techniques are adopted to allow for anatomic placement of the graft. CONCLUSION: This report demonstrates how the femoral tunnel can be created using the anteromedial portal instead of a transtibial approach for reconstruction of the ACL.

16.
PLoS One ; 12(1): e0164549, 2017.
Article in English | MEDLINE | ID: mdl-28060814

ABSTRACT

BACKGROUND: The purpose of this biomechanical study was to determine the effect of shortened clavicle malunion on the center of rotation of the glenohumeral (GH) joint, and the capacity of repair to restore baseline kinematics. METHODS: Six shoulders underwent automated abduction (ABD) and abbreviated throwing motion (ATM) using a 7-DoF automated upper extremity testing system in combination with an infrared motion capture system to measure the center of rotation of the GH joint. ATM was defined as pure lateral abduction and late cocking phase to the end of acceleration. Torsos with intact clavicle underwent testing to establish baseline kinematics. Then, the clavicles were subjected to midshaft fracture followed by kinematics testing. The fractured clavicles underwent repairs first by clavicle length restoration with plate fixation, and then by wiring of fragments with a 2-cm overlap to simulate shortened malunion. Kinematic testing was conducted after each repair technique. Center of rotation of the GH joint was plotted across all axes to outline 3D motion trajectory and area under the curve. RESULTS: Throughout ABD, malunion resulted in increased posterior and superior translation compared to baseline. Plate fixation restored posterior and superior translations at lower abduction angles but resulted in excess anterior and inferior translation at overhead angles. Throughout ATM, all conditions were significantly anterior and superior to baseline. Translation with malunion was situated anterior to the fractured and ORIF conditions at lower angles of external rotation. Plate fixation did not restore baseline anteroposterior or superoinferior translation at any angle measured. CONCLUSIONS: This study illustrates the complex interplay of the clavicle and the GH joint. While abnormal clavicle alignment alters shoulder motion, restoration of clavicle length does not necessarily restore GH kinematics to baseline. Rehabilitation of the injured shoulder must address the osseous injury and the dynamic forces of the shoulder girdle.


Subject(s)
Clavicle/injuries , Fractures, Bone , Models, Theoretical , Shoulder Joint/physiopathology , Wound Healing , Biomechanical Phenomena , Clavicle/surgery , Computer Simulation , Fractures, Bone/pathology , Fractures, Bone/surgery , Humans , Male , Middle Aged , Range of Motion, Articular , Recovery of Function
17.
J Surg Orthop Adv ; 26(4): 193-199, 2017.
Article in English | MEDLINE | ID: mdl-29461189

ABSTRACT

Patients commonly present with shoulder complaints to the primary care and orthopaedic setting. The differential includes rotator cuff tears, subacromial impingement, osteoarthritis, and adhesive capsulitis, also known as frozen shoulder. Despite the prevalence of adhesive capsulitis, it is commonly misdiagnosed and management remains unclear. This article reviews the presentation of adhesive capsulitis, presents an overview of the pathophysiology of this poorly understood disease, and evaluates nonoperative treatment options for adhesive capsulitis. (Journal of Surgical Orthopaedic Advances 26(4):193-199, 2017).


Subject(s)
Bursitis/therapy , Humans , Treatment Outcome
18.
Clin J Sport Med ; 27(3): 308-320, 2017 May.
Article in English | MEDLINE | ID: mdl-27434188

ABSTRACT

OBJECTIVE: Adhesive capsulitis is a self-limiting condition in a majority of patients and is often treated nonoperatively. However, symptoms may take 2 to 3 years to resolve fully. A small, but significant, portion of patients require surgical intervention. The purpose of this systematic review is to evaluate the efficacy of corticosteroid injections for the treatment of adhesive capsulitis (AC). DATA SOURCES: A review of articles indexed by the United States National Library of Medicine was conducted by querying the PubMed database for studies involving participants with AC, frozen shoulder, stiff shoulder, or painful shoulder. Articles that included corticosteroids, glucocorticoids, steroids, and injections were included. MAIN RESULTS: Corticosteroid injections provide significant symptom relief for 2 to 24 weeks. Injections can be performed intra-articularly or into the subacromial space. Evidence suggests that a 20 mg dose of triamcinolone may be as effective as a 40 mg injection. It remains unclear whether image-guided injections produce a clinically significant difference in outcomes when compared with landmark-guided (blind) injections. Corticosteroids may be less beneficial for diabetic patients. Patients using protease inhibitors (antiretroviral therapy) should not receive triamcinolone because the drug-drug interaction may result in iatrogenic Cushing syndrome. CONCLUSIONS: Corticosteroid injections for AC demonstrate short-term efficacy, but may not provide a long-term benefit. More high quality, prospective studies are needed to determine whether corticosteroid injections using ultrasound guidance significantly improve outcomes.


Subject(s)
Adrenal Cortex Hormones/therapeutic use , Bursitis/therapy , Shoulder Pain/therapy , Contraindications , Diabetes Mellitus/physiopathology , Humans , Injections, Intra-Articular , Protease Inhibitors , Range of Motion, Articular , Shoulder Joint/physiopathology , Triamcinolone/therapeutic use
19.
Arthroscopy ; 33(3): 617-624, 2017 Mar.
Article in English | MEDLINE | ID: mdl-27956232

ABSTRACT

PURPOSE: To assess the changes in tibiofemoral contact pressure and contact area in human knees with a horizontal cleavage tear before and after treatment. METHODS: Ten human cadaveric knees were tested. Pressure sensors were placed under the medial meniscus and the knees were loaded at twice the body weight for 20 cycles at 0°, 10°, and 20° of flexion. Contact area and pressure were recorded for the intact meniscus, the meniscus with a horizontal cleavage tear, after meniscal repair, after partial meniscectomy (single leaflet), and after subtotal meniscectomy (double leaflet). RESULTS: The presence of a horizontal cleavage tear significantly increased average peak contact pressure and reduced effective average tibiofemoral contact area at all flexion angles tested compared with the intact state (P < .03). There was approximately a 70% increase in contact pressure after creation of the horizontal cleavage tear. Repairing the horizontal cleavage tear restored peak contact pressures and areas to within 15% of baseline, statistically similar to the intact state at all angles tested (P < .05). Partial meniscectomy and subtotal meniscectomy significantly increased average peak contact pressure and reduced average contact area at all degrees of flexion compared with the intact state (P < .05). CONCLUSIONS: The presence of a horizontal cleavage tear in the medial meniscus causes a significant reduction in contact area and a significant elevation in contact pressure. These changes may accelerate joint degeneration. A suture-based repair of these horizontal cleavage tears returns the contact area and contact pressure to nearly normal, whereas both partial and subtotal meniscectomy lead to significant reductions in contact area and significant elevations in contact pressure within the knee. Repairing horizontal cleavage tears may lead to improved clinical outcomes by preserving meniscal tissue and the meniscal function. CLINICAL RELEVANCE: Understanding contact area and peak contact pressure resulting from differing strategies for treating horizontal cleavage tears will allow the surgeon to evaluate the best strategy for treating his or her patients who present with this meniscal pathology.


Subject(s)
Knee Joint/physiopathology , Menisci, Tibial/physiopathology , Tibial Meniscus Injuries/physiopathology , Tibial Meniscus Injuries/surgery , Aged , Biomechanical Phenomena/physiology , Cadaver , Female , Humans , Knee Joint/surgery , Male , Menisci, Tibial/surgery , Pressure , Range of Motion, Articular/physiology , Stress, Mechanical
20.
BMC Musculoskelet Disord ; 17(1): 480, 2016 11 17.
Article in English | MEDLINE | ID: mdl-27855670

ABSTRACT

BACKGROUND: Changes to the integrity of the acromioclavicular (AC) joint impact scapulothoracic and clavicular kinematics. AC ligaments provide anterior-posterior stability, while the coracoclavicular (CC) ligaments provide superior-inferior stability and a restraint to scapular internal rotation. The purpose of this cadaveric study was to describe the effect of sequential AC and CC sectioning on glenohumeral (GH) kinematics during abduction (ABD) of the arm. We hypothesized that complete AC ligament insult would result in altered GH translation in the anterior-posterior plane during abduction, while subsequent sectioning of both CC ligaments would result in an increasing inferior shift in GH translation. METHODS: Six cadaveric shoulders were studied to evaluate the impact of sequential sectioning of AC and CC ligaments on GH kinematics throughout an abduction motion in the coronal plane. Following an examination of the baseline, uninjured kinematics, the AC ligaments were then sectioned sequentially: (1) Anterior, (2) Inferior, (3) Posterior, and (4) Superior. Continued sectioning of CC ligamentous structures followed: the (5) trapezoid and then the (6) conoid ligaments. For each group, the GH translation and the area under the curve (AUC) were measured during abduction using an intact cadaveric shoulder. Total translation was calculated for each condition between ABD 30° and ABD 150° using the distance formula, and a univariate analysis was used to compare total translation for each axis during the different conditions. RESULTS: GH kinematics were not altered following sequential resection of the AC ligaments. Disruption of the trapezoid resulted in significant anterior and lateral displacement of the center of GH rotation. Sectioning the conoid ligament further increased the inferior shift in GH displacement. CONCLUSION: A combined injury of the AC and CC ligaments significantly alters GH kinematics during abduction. Type III AC separations, result in a significant change in the shoulder's motion and may warrant surgical reconstruction to restore normal function.


Subject(s)
Acromioclavicular Joint/injuries , Ligaments, Articular/injuries , Shoulder Joint/physiopathology , Acromioclavicular Joint/physiopathology , Biomechanical Phenomena , Humans , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...