Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Main subject
Language
Publication year range
1.
Sensors (Basel) ; 24(2)2024 Jan 09.
Article in English | MEDLINE | ID: mdl-38257497

ABSTRACT

Global warming is influenced by an increase in greenhouse gas (GHG) concentration in the atmosphere. Consequently, Net Ecosystem Exchange (NEE) is the main factor that influences the exchange of carbon (C) between the atmosphere and the soil. As a result, agricultural ecosystems are a potential carbon dioxide (CO2) sink, particularly rice paddies (Oryza sativa). Therefore, a static chamber with a portable CO2 analyzer was designed and implemented for three rice plots to monitor CO2 emissions. Furthermore, a weather station was installed to record meteorological variables. The vegetative, reproductive, and maturation phases of the crop lasted 95, 35, and 42 days post-sowing (DPS), respectively. In total, the crop lasted 172 DPS. Diurnal NEE had the highest CO2 absorption capacity at 10:00 a.m. for the tillering stage (82 and 89 DPS), floral primordium (102 DPS), panicle initiation (111 DPS), and flowering (126 DPS). On the other hand, the maximum CO2 emission at 82, 111, and 126 DPS occurred at 6:00 p.m. At 89 and 102 DPS, it occurred at 4:00 and 6:00 a.m., respectively. NEE in the vegetative stage was -25 µmolCO2 m2 s-1, and in the reproductive stage, it was -35 µmolCO2 m2 s-1, indicating the highest absorption capacity of the plots. The seasonal dynamics of NEE were mainly controlled by the air temperature inside the chamber (Tc) (R = -0.69), the relative humidity inside the chamber (RHc) (R = -0.66), and net radiation (Rn) (R = -0.75). These results are similar to previous studies obtained via chromatographic analysis and eddy covariance (EC), which suggests that the portable analyzer could be an alternative for CO2 monitoring.


Subject(s)
Oryza , Carbon Dioxide , Ecosystem , Agriculture , Atmosphere
2.
Data Brief ; 19: 170-178, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29892630

ABSTRACT

This article presents data on corrosion and dissolved copper in copper tubes that transport drinking water in domiciles of the Azogues city, Ecuador. Corrosion tests were performed using copper coupons exposed to water with different concentrations of free chlorine for 30, 60, 90 and 180 days. The determination of the copper corrosion rate exposed in chlorine was carried out by means of gravimetric tests. With weight loss data, the corrosion rate was determined. By means of static immersion tests, copper release of coupon surface was determined. In the obtained data it was observed that the corrosion rate and the release of copper increases with the chlorine concentration. This data is beneficial for drinking water companies and building builders by providing information on the corrosion and leaching behavior of copper pipes when exposed to chlorine and is useful for predicting the service life copper pipes. In addition, it could allow assessing the health risk by consuming water with copper in solution.

3.
Data Brief ; 18: 111-123, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29896499

ABSTRACT

This document presents the physical-chemical parameters with the objective of evaluating and analyzing the drinking water quality in the Azogues city applying the water quality index (WQI) and to research the water stability in the distribution network using corrosion indexes. Thirty samples were collected monthly for six months throughout the drinking water distribution network; turbidity, temperature, electric conductivity, pH, total dissolved solids, total hardness, calcium, magnesium, alkalinity, chlorides, nitrates, sulfates and phosphates were determined; the physical-chemical parameters were measured using standard methods. The processed data revealed that the average values ​​of LSI, RSI and PSI were 0.5 (±0.34), 6.76 (±0.6), 6.50 (±0.99) respectively. The WQI calculation indicated that 100% of the samples are considered excellent quality water. According to the Langelier, Ryznar and Pukorius indexes showed that drinking water in Azogues is corrosive. The quality of drinking water according to the WQI is in a good and excellent category.

SELECTION OF CITATIONS
SEARCH DETAIL
...