Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Main subject
Publication year range
1.
Polymers (Basel) ; 16(5)2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38475402

ABSTRACT

Biocomposite films based on PLA reinforced with different ß-TCP contents (10%, 20%, and 25%wt.) were fabricated via solvent casting and immersed in SBF for 7, 14, and 21 days. The bioactivity, morphological, and thermal behavior of composites with immersion were studied using scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) microanalysis, weight loss (WL), X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and gel permeation chromatography (GPC). This broad analysis leads to a deeper understanding of the evolution of the polymer-filler interaction with the degradation of the biocomposites. The results showed that ß-TCP gradually evolved into carbonated hydroxyapatite as the immersion time increased. This evolution affected the interaction of ß-TCP with PLA. PLA and ß-TCP interactions differed from PLA and carbonated hydroxyapatite interactions. It was observed that ß-TCP inhibited PLA hydrolysis but accelerated the thermal degradation of the polymer. ß-TCP retarded the cold crystallization of PLA and hindered its crystallinity. However, after immersion in SBF, particles accelerated the cold crystallization of PLA. Therefore, considering the evolution of ß-TCP with immersion in SBF is crucial for an accurate analysis of the biocomposites' degradation. These findings enhance the comprehension of the degradation mechanism in PLA/ß-TCP, which is valuable for predicting the degradation performance of PLA/ß-TCP in medical applications.

2.
Polymers (Basel) ; 15(24)2023 Dec 11.
Article in English | MEDLINE | ID: mdl-38139919

ABSTRACT

Improvements in Tissue Engineering and Regenerative Medicine (TERM)-type technologies have allowed the development of specific materials that, together with a better understanding of bone tissue structure, have provided new pathways to obtain biomaterials for bone tissue regeneration. In this manuscript, bioabsorbable materials are presented as emerging materials in tissue engineering therapies related to bone lesions because of their ability to degrade in physiological environments while the regeneration process is completed. This comprehensive review aims to explore the studies, published since its inception (2010s) to the present, on bioabsorbable composite materials based on PLA and PCL polymeric matrix reinforced with Mg, which is also bioabsorbable and has recognized osteoinductive capacity. The research collected in the literature reveals studies based on different manufacturing and dispersion processes of the reinforcement as well as the physicochemical analysis and corresponding biological evaluation to know the osteoinductive capacity of the proposed PLA/Mg and PCL/Mg composites. In short, this review shows the potential of these composite materials and serves as a guide for those interested in bioabsorbable materials applied in bone tissue engineering.

3.
Materials (Basel) ; 16(2)2023 Jan 10.
Article in English | MEDLINE | ID: mdl-36676398

ABSTRACT

The wear behavior of the Mg-3wt.% Zn-0.4wt.% Ca (ZX30) alloy was tested using a pin-on-disc configuration with AZ31 alloy discs as counterparts under dry sliding conditions. The ZX30 alloy was tested in different states: as-cast, solution-treated, peak-aged, and over-aged. Wear rates and friction coefficients were measured at different loads and sliding speeds. Abrasion and oxidation were the main wear mechanisms found in all the conditions tested. Moreover, aluminum oxides were detected on the worn surfaces, which indicates the presence of an adhesive wear mechanism. The wear behavior of the studied ZX30 alloy showed a greater tendency towards oxidative wear than other Mg alloys, and the microstructure observed strongly affected the wear behavior.

4.
Materials (Basel) ; 17(1)2023 Dec 22.
Article in English | MEDLINE | ID: mdl-38203923

ABSTRACT

The microstructure and wear properties of a Mg-1wt.% Zn-1wt.% Ca (ZX11) alloy with different heat treatments have been investigated. The ZX11 alloy was tested in the as-cast state and after different heat treatment conditions: solution-treated (at 450 °C for 24 h), peak-aged (solution-treated + aged at 180 °C for 3 h), and over-aged (solution-treated + aged at 180 °C for 24 h). The microstructure of the as-cast sample showed a continuous intermetallic phase at the grain boundaries, while the heat-treated samples exhibited discrete precipitated particles within the grains. To evaluate the wear behavior, the samples were tested using a pin-on-disc configuration, where the wear rates and friction coefficients were measured at different loads and sliding speeds. An AZ31 magnesium alloy was used as the counterbody. The worn surfaces and the wear debris were studied to identify the main wear mechanisms corresponding to each test condition. The results indicated the presence of abrasion, oxidation, and adhesive wear mechanisms in all testing conditions. In the as-cast state, delamination and plastic deformation were the dominant wear mechanisms, while they were less relevant in the heat-treated conditions. The peak-aged samples exhibited the lowest wear rates, suggesting that modifying the distribution of intermetallic precipitates contributed to enhancing the wear resistance of the alloy.

5.
Gels ; 8(7)2022 Jul 07.
Article in English | MEDLINE | ID: mdl-35877511

ABSTRACT

In the present day, the increment in life expectancy has led to the necessity of developing new biomaterials for the restoration or substitution of damaged organs that have lost their functionalities. Among all the research about biomaterials, this review paper aimed to expose the main possibilities that the sol-gel synthesis method can provide for the fabrication of materials with interest in the biomedical field, more specifically, when this synthesis method is used to improve the biological properties of different magnesium alloys used as biomaterials. The sol-gel method has been widely studied and used to generate ceramic materials for a wide range of purposes during the last fifty years. Focused on biomedical research, the sol-gel synthesis method allows the generation of different kinds of biomaterials with diverse morphologies and a high potential for the biocompatibility improvement of a wide range of materials commonly used in the biomedical field such as metallic implants, as well as for the generation of drug delivery systems or interesting biomaterials for new tissue engineering therapies.

6.
Materials (Basel) ; 15(9)2022 May 09.
Article in English | MEDLINE | ID: mdl-35591731

ABSTRACT

Aluminum matrix composites reinforced with carbon fiber have been manufactured for the first time by infiltrating an A413 aluminum alloy in carbon fiber woven using high-pressure die casting (HPDC). Composites were manufactured with unidirectional carbon fibers and with 2 × 2 twill carbon wovens. The HPDC allowed full wetting of the carbon fibers and the infiltration of the aluminum alloy in the fibers meshes using aluminum at 680 °C. There was no discontinuity at the carbon fiber-matrix interface, and porosity was kept below 0.1%. There was no degradation of the carbon fibers by their reaction with molten aluminum, and a refinement of the microstructure in the vicinity of the carbon fibers was observed due to the heat dissipation effect of the carbon fiber during manufacturing. The mechanical properties of the composite materials showed a 10% increase in Young's modulus, a 10% increase in yield strength, and a 25% increase in tensile strength, which are caused by the load transfer from the alloy to the carbon fibers. There was also a 70% increase in elongation for the unidirectionally reinforced samples because of the finer microstructure and the load transfer to the fibers, allowing the formation of larger voids in the matrix before breaking. The comparison with different mechanical models proves that there was an effective load transference from the matrix to the fibers.

7.
ACS Biomater Sci Eng ; 7(12): 5861-5877, 2021 12 13.
Article in English | MEDLINE | ID: mdl-34748311

ABSTRACT

Magnesium AZ31 alloy substrates were coated with different coatings, including sol-gel silica-reinforced with graphene nanoplatelets, sol-gel silica, plasma electrolytic oxidation (PEO), and combinations of them, to improve cytocompatibility and control the corrosion rate. Electrochemical corrosion tests, as well as hydrogen evolution tests, were carried out using Hanks' solution as the electrolyte to assess the anticorrosion behavior of the different coating systems in a simulated body fluid. Preliminary cytocompatibility assessment of the different coating systems was carried out by measuring the metabolic activity, deoxyribonucleic acid quantification, and the cell growth of premyoblastic C2C12-GFP cell cultures on the surface of the different coating systems. Anticorrosion behavior and cytocompatibility were improved with the application of the different coating systems. The use of combined PEO + SG and PEO + SG/GNP coatings significantly decreased the degradation of the specimens. The monolayer sol-gel coatings, with and without GNPs, presented the best cytocompatibility improvement.


Subject(s)
Graphite , Coated Materials, Biocompatible , Corrosion , Magnesium , Silicon Dioxide
8.
Materials (Basel) ; 14(21)2021 Oct 29.
Article in English | MEDLINE | ID: mdl-34772039

ABSTRACT

In additive manufacturing (AM), the technology and processing parameters are key elements that determine the characteristics of samples for a given material. To distinguish the effects of these variables, we used the same AISI 316L stainless steel powder with different AM techniques. The techniques used are the most relevant ones in the AM of metals, i.e., direct laser deposition (DLD) with a high-power diode laser and selective laser melting (SLM) using a fiber laser and a novel CO2 laser, a novel technique that has not yet been reported with this material. The microstructure of all samples showed austenitic and ferritic phases, which were coarser with the DLD technique than for the two SLM ones. The hardness of the fiber laser SLM samples was the greatest, but its bending strength was lower. In SLM with CO2 laser pieces, the porosity and lack of melting reduced the fracture strain, but the strength was greater than in the fiber laser SLM samples under certain build-up strategies. Specimens manufactured using DLD showed a higher fracture strain than the rest, while maintaining high strength values. In all the cases, crack surfaces were observed and the fracture mechanisms were determined. The processing conditions were compared using a normalized parameters methodology, which has also been used to explain the observed microstructures.

9.
Materials (Basel) ; 14(15)2021 Jul 31.
Article in English | MEDLINE | ID: mdl-34361495

ABSTRACT

To modulate the properties of degradable implants from outside of the human body represents a major challenge in the field of biomaterials. Polylactic acid is one of the most used polymers in biomedical applications, but it tends to lose its mechanical properties too quickly during degradation. In the present study, a way to reinforce poly-L lactic acid (PLLA) with magnetic nanoparticles (MNPs) that have the capacity to heat under radiofrequency electromagnetic fields (EMF) is proposed. As mechanical and degradation properties are related to the crystallinity of PLLA, the aim of the work was to explore the possibility of modifying the structure of the polymer through the heating of the reinforcing MNPs by EMF within the biological limit range f·H < 5·× 109 Am-1·s-1. Composites were prepared by dispersing MNPs under sonication in a solution of PLLA. The heat released by the MNPs was monitored by an infrared camera and changes in the polymer were analyzed with differential scanning calorimetry and nanoindentation techniques. The crystallinity, hardness, and elastic modulus of nanocomposites increase with EMF treatment.

10.
Materials (Basel) ; 14(4)2021 Feb 22.
Article in English | MEDLINE | ID: mdl-33671647

ABSTRACT

Zeolites are widely used in high-temperature oil refining processes such as fluid catalytic cracking (FCC), hydrocracking, and aromatization. Significant energy cost are associated with these processes due to the high temperatures required. The induction heating promoted by magnetic nanoparticles (MNPs) under radio frequency fields could contribute to solving this problem by providing a supplementary amount of heat in a nano-localized way, just at the active centre site where the catalytic process takes place. In this study, the potential of such a complementary route to reducing energetic requirements is evaluated. The catalytic cracking reaction under a hydrogen atmosphere (hydrocracking) applied to the conversion of plastics was taken as an application example. Thus, a commercial zeolite catalyst (H-USY) was impregnated with three different magnetic nanoparticles: nickel (Ni), cobalt (Co), maghemite (γ-Fe2O3), and their combinations and subjected to electromagnetic fields. Temperature increases of approximately 80 °C were measured for H-USY zeolite impregnated with γ-Fe2O3 and Ni-γ-Fe2O3 due to the heat released under the radio frequency fields. The potential of the resulting MNPs derived catalyst for HDPE (high-density polyethylene) conversion was also evaluated by thermogravimetric analysis (TGA) under hydrogen atmosphere. This study is a proof of concept to show that induction heating could be used in combination with traditional resistive heating as an additional energy supplier, thereby providing an interesting alternative in line with a greener technology.

11.
Materials (Basel) ; 13(15)2020 Jul 27.
Article in English | MEDLINE | ID: mdl-32726967

ABSTRACT

Preliminary characterization of the microstructure of Al/SiCp composites prepared by Laser Metal Deposition (LMD) was analyzed, and the microhardness and wear behavior of the materials manufactured have been evaluated. It has been determined that the combined effect of the laser speed and power is decisive for the fabrication process. The microstructure characterization shows that the presence of hygroscopic Al4C3 can be avoided by adding Ti to the composite matrix. The wear behavior of the LMD samples and their microhardness have been compared with Powder Metallurgy samples with the same composition. The LMD samples showed higher hardness and wear resistance.

12.
Micromachines (Basel) ; 9(12)2018 Nov 29.
Article in English | MEDLINE | ID: mdl-30501095

ABSTRACT

The effect of post-helium irradiation annealing on bubbles and nanoindentation hardness of two reduced activation ferritic martensitic steels for nuclear fusion applications (EUROFER97 and EU-ODS EUROFER) has been studied. Helium-irradiated EUROFER97 and EU-ODS EUROFER were annealed at 450 °C for 100 h in an argon atmosphere. The samples were tested by nanoindentation and studied by transmission electron microscopy extracting some focused ion beam lamellae containing the whole implanted zone (≈50 µm). A substantial increment in nanoindentation hardness was measured in the area with higher helium content, which was larger in the case of EUROFER97 than in EU-ODS EUROFER. In terms of microstructure defects, while EU-ODS EUROFER showed larger helium bubbles, EUROFER97 experienced the formation of a great population density of them, which means that the mechanism that condition the evolution of cavities for these two materials are different and completely dependent on the microstructure.

SELECTION OF CITATIONS
SEARCH DETAIL
...