Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Catheter Cardiovasc Interv ; 92(3): 466-476, 2018 09 01.
Article in English | MEDLINE | ID: mdl-29314563

ABSTRACT

OBJECTIVES: To evaluate the outcomes of subadventitial stenting (SS) around occluded stents for recanalizing in-stent chronic total occlusions (IS-CTOs). BACKGROUND: There is little evidence on the outcomes of SS for IS-CTO. METHODS: We examined the outcomes of SS for IS-CTO PCI at 14 centers between July 2011 and June 2017, and compared them to historical controls recanalized using within-stent stenting (WSS). Target-vessel failure (TVF) on follow-up was the endpoint of this study, and was defined as a composite of cardiac death, target-vessel myocardial infarction, and target-vessel revascularization. RESULTS: During study period, 422 IS-CTO PCIs were performed, of which 32 (7.6%) were recanalized with SS, usually when conventional approaches failed. The most frequent CTO vessel was the right coronary artery (72%). Mean J-CTO score was 3.1 ± 0.9. SS was antegrade in 53%, and retrograde in 47%. Part of the occluded stent was crushed in 37%, while the whole stent was crushed in 63%. Intravascular imaging was used in 59%. One patient (3.1%) suffered tamponade. Angiographic follow-up was performed in 10/32 patients: stents were patent in six cases, one had mild neointimal hyperplasia, and three had severe restenosis at the SS site. Clinical follow-up was available for 29/32 patients for a mean of 388 ± 303 days. The 24-month incidence of TVF was 13.8%, which was similar to historical controls treated with WSS (19.5%, P = 0.49). CONCLUSIONS: SS is rarely performed, usually as last resort, to recanalize complex IS-CTOs. It is associated with favorable acute and mid-term outcomes, but given the small sample size of our study additional research is warranted.


Subject(s)
Coronary Occlusion/therapy , Coronary Restenosis/therapy , Drug-Eluting Stents , Percutaneous Coronary Intervention , Aged , Australia , Canada , Chronic Disease , Computed Tomography Angiography , Coronary Angiography/methods , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/etiology , Coronary Occlusion/mortality , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/etiology , Coronary Restenosis/mortality , Europe , Female , Humans , Male , Middle Aged , Multidetector Computed Tomography , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Percutaneous Coronary Intervention/mortality , Prosthesis Design , Registries , Retreatment , Retrospective Studies , Time Factors , Tomography, Optical Coherence , Treatment Outcome , Ultrasonography, Interventional , United States , Vascular Patency
2.
Int J Cardiovasc Imaging ; 33(6): 771-778, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28120155

ABSTRACT

Objectives The aim of this study was to quantify the radiation dose reduction during coronary angiography and percutaneous coronary intervention (PCI) through removal of the anti-scatter grid (ASG), and to assess its impact on image quality in adult patients with a low body mass index (BMI). Methods A phantom with different thicknesses of acrylic was used with a Westmead Test Object to simulate patient sizes and assess image quality. 129 low BMI patients underwent coronary angiography or PCI with or without the ASG in situ. Radiation dose was compared between both patient groups. Results With the same imaging system and a comparable patient population, ASG removal was associated with a 47% reduction in total dose-area product (DAP) (p < 0.001). Peak skin dose was reduced by 54% (p < 0.001). Operator scatter was reduced to a similar degree and was significantly reduced through removal of the ASG. Using an image quality phantom it was demonstrated that image quality remained satisfactory. Conclusions Removal of the ASG is a simple and effective method to significantly reduce radiation dose in coronary angiography and PCI. This was achieved while maintaining adequate diagnostic image quality. Selective removal of the ASG is likely to improve the radiation safety of cardiac angiography and interventions.


Subject(s)
Coronary Angiography/instrumentation , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Occupational Exposure/prevention & control , Radiation Dosage , Radiation Exposure/prevention & control , Radiography, Interventional/instrumentation , Scattering, Radiation , Aged , Aged, 80 and over , Body Mass Index , Coronary Angiography/adverse effects , Equipment Design , Female , Humans , Male , Middle Aged , Occupational Exposure/adverse effects , Patient Safety , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Phantoms, Imaging , Pilot Projects , Predictive Value of Tests , Radiation Exposure/adverse effects , Radiography, Interventional/adverse effects , Risk Factors , Stents
3.
EuroIntervention ; 12(8): e939-e947, 2016 Oct 10.
Article in English | MEDLINE | ID: mdl-27721210

ABSTRACT

AIMS: The aim of this study was to evaluate whether a real-time (RT) colour pictorial radiation dose monitoring system reduces patient skin and total radiation dose during coronary angiography and intervention. METHODS AND RESULTS: Patient demographics, procedural variables and radiation parameters were recorded before and after institution of the RT skin dose recording system. Peak skin dose as well as traditionally available measures of procedural radiation dose were compared. A total of 1,077 consecutive patients underwent coronary angiography, of whom 460 also had PCI. Institution of the RT skin dose recording system resulted in a 22% reduction in peak skin dose after accounting for confounding variables. Radiation dose reduction was most pronounced in those having PCI but was also seen over a range of subgroups including those with prior coronary artery bypass surgery, high BMI, and with radial arterial access. This was associated with a significant reduction in the number of patients placed at risk of skin damage. Similar reductions in parameters reflective of total radiation dose were also demonstrated after institution of RT radiation monitoring. CONCLUSIONS: Institution of an RT skin dose recording reduced patient peak skin and total radiation dose during coronary angiography and intervention. Consideration should be given to widespread adoption of this technology.


Subject(s)
Cardiac Catheterization/methods , Coronary Angiography/methods , Fluoroscopy/methods , Percutaneous Coronary Intervention/methods , Radiation Dosage , Radiation Exposure/prevention & control , Radiation Monitoring/methods , Skin , Aged , Aged, 80 and over , Body Mass Index , Coronary Artery Bypass , Female , Femoral Artery , Fractional Flow Reserve, Myocardial , Humans , Interrupted Time Series Analysis , Linear Models , Male , Middle Aged , Operative Time , Radial Artery , Radiation Monitoring/instrumentation
4.
Pacing Clin Electrophysiol ; 28(8): 867-9, 2005 Aug.
Article in English | MEDLINE | ID: mdl-16105017

ABSTRACT

The finding of complete occlusion of the superior venal cava during the performance of cardiac pacing is rare. We report a case where performance of angioplasty aided the successful completion of permanent pacemaker implantation.


Subject(s)
Angioplasty , Atrial Flutter/therapy , Pacemaker, Artificial , Superior Vena Cava Syndrome/therapy , Humans , Male , Middle Aged , Radiography , Superior Vena Cava Syndrome/diagnostic imaging
SELECTION OF CITATIONS
SEARCH DETAIL
...