Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Neonatal Perinatal Med ; 8(4): 307-11, 2015.
Article in English | MEDLINE | ID: mdl-26836819

ABSTRACT

OBJECTIVE: Compare how NICUs within academic centers in Canada, France, and the United States make discharge decisions regarding cardiorespiratory recordings and home use of apnea monitors, oximeters and caffeine. STUDY DESIGN: An anonymous survey was sent to neonatologists through the member listserv of the American Academy of Pediatrics Section on Perinatal Pediatrics, the Canadian Fellowship Program Directory, and to Level 3 NICUs in France. RESULTS: The response rates were 89% , 83% , and 79% for US, Canada and France respectively. In Canada, 45% perform pre-discharge recordings vs. 38% in France and 24% in the US. Apnea free days prior to discharge were required in 100% of centers in Canada, 96% in France, and 92% in the US. In Canada and France, 65% and 68% of units discharge patients on monitors vs. 99% in the US. 64% of the US centers sometimes use home caffeine compared to 40% in Canada and 34% in France. Over 60% of the centers in Canada and France wait until at least 40 weeks post menstrual age to discharge patients, whereas only about 33% of the US wait that late to discharge patients. CONCLUSIONS: Discharge practices from NICUs are not well standardized across institutions or countries. Canada and France keep infants in the hospital longer and are less likely than the US to use home monitoring and home caffeine.


Subject(s)
Academic Medical Centers/methods , Apnea/diagnosis , Clinical Decision-Making/methods , Intensive Care Units, Neonatal/statistics & numerical data , Patient Discharge/statistics & numerical data , Academic Medical Centers/statistics & numerical data , Caffeine/administration & dosage , Canada , Central Nervous System Stimulants/administration & dosage , France , Gestational Age , Humans , Infant , Infant, Newborn , Monitoring, Physiologic/statistics & numerical data , Respiratory Function Tests , United States
2.
Phys Rev Lett ; 112(2): 026402, 2014 Jan 17.
Article in English | MEDLINE | ID: mdl-24484031

ABSTRACT

We study the orbital susceptibility of multiband systems with a pair of Dirac points interpolating between honeycomb and dice lattices. Despite having the same zero-field energy spectrum, these different systems exhibit spectacular differences in their orbital magnetic response, ranging from dia- to paramagnetism at Dirac points. We show that this striking behavior is related to a topological Berry phase varying continuously from π (graphene) to 0 (dice). The latter strongly constrains interband effects, resulting in an unusual dependence of the magnetic response also at finite doping.

SELECTION OF CITATIONS
SEARCH DETAIL
...