Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Heart Vessels ; 39(5): 427-437, 2024 May.
Article in English | MEDLINE | ID: mdl-38189924

ABSTRACT

BACKGROUND: Data comparing remote magnetic catheter navigation (RMN) with manual catheter navigation in combination with contact force sensing (MCN-CF) ablation of atrial fibrillation (AF) is lacking. The primary aim of the present retrospective comparative study was to compare the outcome of RMN versus (vs.) MCN-CF ablation of AF with regards to AF recurrence. Secondary aim was to analyze periprocedural risk, ablation characteristics and repeat procedures. METHODS: We retrospectively analyzed 452 patients undergoing a total of 605 ablations of AF: 180 patients were ablated using RMN, 272 using MCN-CF. RESULTS: Except body mass index there was no significant difference between groups at baseline. After a mean 1.6 ± 1.6 years of follow-up and 1.3 ± 0.4 procedures, 81% of the patients in the MCN-CF group remained free of AF recurrence compared to 53% in the RMN group (P < 0.001). After analysis of 153 repeat ablations (83 MCN-RF vs. 70 RMN; P = 0.18), there was a significantly higher reconnection rate of pulmonary veins after RMN ablation (P < 0.001). In multivariable Cox-regression analysis, RMN ablation (P < 0.001) and left atrial diameter (P = 0.013) was an independent risk factor for AF recurrence. Procedure time, radiofrequency application time and total fluoroscopy time and fluoroscopy dose were higher in the RMN group without difference in total number of ablation points. Complication rates did not differ significantly between groups (P = 0.722). CONCLUSIONS: In our retrospective comparative study, the AF recurrence rate and pulmonary vein reconnection rate is significantly lower with more favorable procedural characteristics and similar complication rate utilizing MCN-CF compared to RMN.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Retrospective Studies , Treatment Outcome , Catheters , Catheter Ablation/adverse effects , Catheter Ablation/methods , Magnetic Phenomena , Pulmonary Veins/surgery
2.
J Interv Card Electrophysiol ; 65(3): 685-693, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35907108

ABSTRACT

BACKGROUND: In atrial fibrillation (AF) patients, catheter ablation of pulmonary veins (PVI) is the most effective therapeutic option to maintain sinus rhythm. To improve successful PVI, contact force-sensing (CF) catheters became routinely available. Previous studies did not clearly show superior clinical efficacy in comparison with non-CF catheters. METHODS: We investigated consecutive patients, who underwent index PVI for AF at our hospital between 2012 and 2018. Three hundred and fifty-four patients were ablated without CF. After availability of CF catheters in 2016, 317 patients were ablated using CF. In case of crossover between the groups, follow-up was censored. The primary endpoint was any documented atrial tachycardia (AT) or atrial fibrillation > 30 s after a 3-month blanking period. Secondary endpoints were procedural characteristics and periprocedural complications. RESULTS: There was no significant difference between the groups at baseline except hyperlipidemia. After 365 days of follow-up, 67% of patients in the CF group remained free from AF/AT recurrence compared to 59% in non-CF group (P = 0.038). In multivariable Cox regression analysis, non-CF ablation was an independent risk factor for AF recurrence besides age and persistent AF. Total fluoroscopy time (15 ± 7.6 vs. 28 ± 15.9 min) and total procedure time (114 ± 29.6 vs. 136 ± 38.5 min) were significantly lower for CF-guided PVI (P < 0.001). Complication rates did not differ between groups (P = 0.661). CONCLUSIONS: In our study, the AT/AF recurrence rate and pulmonary vein reconnection rate is lower after CF PVI with a similar complication rate but lower total procedure time and total fluoroscopy time compared to non-CF PVI.


Subject(s)
Atrial Fibrillation , Humans , Atrial Fibrillation/surgery
3.
Pacing Clin Electrophysiol ; 45(1): 14-22, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34687054

ABSTRACT

BACKGROUND: Data comparing remote magnetic catheter navigation (RMN) with manual catheter navigation (MCN) ablation of atrial fibrillation (AF) is lacking. The aim of the present prospective observational study was to compare the outcome of RMN versus (vs.) MCN ablation of AF with regards to AF recurrence. METHODS: The study comprised 667 consecutive patients with a total of 939 procedures: 287 patients were ablated using RMN, 380 using MCN. RESULTS: There was no significant difference between the groups at baseline. After 2.3 ± 2.3 years of follow-up, 23% of the patients in the MCN group remained free of AF recurrence compared to 13% in the RMN group (p < .001). After analysis of 299 repeat ablations (133 MCN, 166 RMN) there was a significantly higher reconnection rate of pulmonary veins after RMN ablation p < .001). In multivariable Cox-regression analysis, RMN ablation was an independent risk factor for AF recurrence besides age, persistent AF, number of isolated pulmonary veins, and left atrial diameter. Procedure time, radiofrequency application time and total number of ablation points were higher in the RMN group. Total fluoroscopy time and total fluoroscopy dose were significantly lower for RMN. Complication rates did not differ between groups (p = .842), although the incidence of significant pericardial effusion was higher in the MCN group (seven cases vs. three in RMN group). CONCLUSIONS: In our study the AF recurrence rate and pulmonary vein reconnection rate is higher after RMN ablation with a similar complication rate but reduced probability of pericardial effusion when compared to MCN.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Magnetics/instrumentation , Female , Fluoroscopy , Humans , Male , Middle Aged , Postoperative Complications , Prospective Studies , Recurrence , Reoperation/statistics & numerical data , Risk Factors
4.
Clin Res Cardiol ; 102(3): 179-84, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23052332

ABSTRACT

BACKGROUND: Electrocardiogram (ECG) assessment plays a crucial role in patients presenting with chest pain and suspected acute coronary syndrome (ACS). In a pilot study, we previously evaluated a capacitive ECG system (cECG) as a novel ECG technique for a fast and simple ECG assessment in patients with ST-elevation myocardial infarction (STEMI). In a next step, the sensitivity and specificity of this novel ECG technique have to be assessed in patients with ACS. HYPOTHESIS: The Fast Infarction Diagnosis ECG Trial (FIDET) is a prospective, bi-center, observer-blinded noninferiority study to evaluate the cECG compared to the conventional ECG (kECG) in the clinical practice for ECG assessment in consecutive patients presenting with suspected ACS. METHODS: In 250 patients who were admitted to the hospital, because of an ACS [including STEMI and non-ST-elevation acute coronary syndrome (NSTE-ACS)], both a kECG and a cECG recording were performed within a time lag of less than 10 min. END POINTS: The primary end point will be sensitivity and specificity of the cECG compared to the kECG in diagnosing a STEMI with a margin of noninferiority of 7.5 %. Secondary end points include sensitivity and specificity of the cECG compared to the kECG in diagnosing an NSTE-ACS, safety of the cECG system (adverse event, serious adverse event and suspected unexpected serious adverse reaction), parameters of the ECG measurement (PQ-interval, QT-interval, ST-amplitude and heart rate) and measurement duration of the two methods. CONCLUSION: FIDET is designed as a noninferiority study to show that a novel cECG system is suitable for the diagnosis of myocardial infarction in the clinical context and might even have benefits, for example by offering a faster and easier ECG assessment.


Subject(s)
Acute Coronary Syndrome/diagnosis , Angina Pectoris/diagnosis , Electrocardiography/instrumentation , Myocardial Infarction/diagnosis , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/physiopathology , Angina Pectoris/etiology , Angina Pectoris/physiopathology , Equipment Design , Germany , Heart Rate , Humans , Myocardial Infarction/complications , Myocardial Infarction/physiopathology , Predictive Value of Tests , Prognosis , Prospective Studies , Reproducibility of Results , Research Design , Sensitivity and Specificity , Time Factors
5.
J Mol Cell Cardiol ; 45(1): 32-43, 2008 Jul.
Article in English | MEDLINE | ID: mdl-18439620

ABSTRACT

The goal of this study was to test the hypothesis that the novel anti-ischemic drug ranolazine, which is known to inhibit late I(Na), could reduce intracellular [Na(+)](i) and diastolic [Ca(2+)](i) overload and improve diastolic function. Contractile dysfunction in human heart failure (HF) is associated with increased [Na(+)](i) and elevated diastolic [Ca(2+)](i). Increased Na(+) influx through voltage-gated Na(+) channels (late I(Na)) has been suggested to contribute to elevated [Na(+)](i) in HF. In isometrically contracting ventricular muscle strips from end-stage failing human hearts, ranolazine (10 micromol/L) did not exert negative inotropic effects on twitch force amplitude. However, ranolazine significantly reduced frequency-dependent increase in diastolic tension (i.e., diastolic dysfunction) by approximately 30% without significantly affecting sarcoplasmic reticulum (SR) Ca(2+) loading. To investigate the mechanism of action of this beneficial effect of ranolazine on diastolic tension, Anemonia sulcata toxin II (ATX-II, 40 nmol/L) was used to increase intracellular Na(+) loading in ventricular rabbit myocytes. ATX-II caused a significant rise in [Na(+)](i) typically seen in heart failure via increased late I(Na). In parallel, ATX-II significantly increased diastolic [Ca(2+)](i). In the presence of ranolazine the increases in late I(Na), as well as [Na(+)](i) and diastolic [Ca(2+)](i) were significantly blunted at all stimulation rates without significantly decreasing Ca(2+) transient amplitudes or SR Ca(2+) content. In summary, ranolazine reduced the frequency-dependent increase in diastolic tension without having negative inotropic effects on contractility of muscles from end-stage failing human hearts. Moreover, in rabbit myocytes the increases in late I(Na), [Na(+)](i) and [Ca(2+)](i) caused by ATX-II, were significantly blunted by ranolazine. These results suggest that ranolazine may be of therapeutic benefit in conditions of diastolic dysfunction due to elevated [Na(+)](i) and diastolic [Ca(2+)](i).


Subject(s)
Acetanilides/pharmacology , Calcium/metabolism , Enzyme Inhibitors/pharmacology , Heart Failure/metabolism , Myocardial Contraction/drug effects , Myocardium/metabolism , Piperazines/pharmacology , Sodium/metabolism , Acetanilides/therapeutic use , Adult , Aged , Animals , Cardiotonic Agents/pharmacology , Cnidarian Venoms/pharmacology , Diastole/drug effects , Enzyme Inhibitors/therapeutic use , Female , Heart Failure/drug therapy , Heart Failure/pathology , Heart Ventricles/metabolism , Heart Ventricles/pathology , Humans , Ion Transport/drug effects , Male , Middle Aged , Myocardium/pathology , Myocytes, Cardiac/metabolism , Myocytes, Cardiac/pathology , Piperazines/therapeutic use , Rabbits , Ranolazine
6.
J Clin Invest ; 116(12): 3127-38, 2006 Dec.
Article in English | MEDLINE | ID: mdl-17124532

ABSTRACT

In heart failure (HF), Ca(2+)/calmodulin kinase II (CaMKII) expression is increased. Altered Na(+) channel gating is linked to and may promote ventricular tachyarrhythmias (VTs) in HF. Calmodulin regulates Na(+) channel gating, in part perhaps via CaMKII. We investigated effects of adenovirus-mediated (acute) and Tg (chronic) overexpression of cytosolic CaMKIIdelta(C) on Na(+) current (I(Na)) in rabbit and mouse ventricular myocytes, respectively (in whole-cell patch clamp). Both acute and chronic CaMKIIdelta(C) overexpression shifted voltage dependence of Na(+) channel availability by -6 mV (P < 0.05), and the shift was Ca(2+) dependent. CaMKII also enhanced intermediate inactivation and slowed recovery from inactivation (prevented by CaMKII inhibitors autocamtide 2-related inhibitory peptide [AIP] or KN93). CaMKIIdelta(C) markedly increased persistent (late) inward I(Na) and intracellular Na(+) concentration (as measured by the Na(+) indicator sodium-binding benzofuran isophthalate [SBFI]), which was prevented by CaMKII inhibition in the case of acute CaMKIIdelta(C) overexpression. CaMKII coimmunoprecipitates with and phosphorylates Na(+) channels. In vivo, transgenic CaMKIIdelta(C) overexpression prolonged QRS duration and repolarization (QT intervals), decreased effective refractory periods, and increased the propensity to develop VT. We conclude that CaMKII associates with and phosphorylates cardiac Na(+) channels. This alters I(Na) gating to reduce availability at high heart rate, while enhancing late I(Na) (which could prolong action potential duration). In mice, enhanced CaMKIIdelta(C) activity predisposed to VT. Thus, CaMKII-dependent regulation of Na(+) channel function may contribute to arrhythmogenesis in HF.


Subject(s)
Calcium-Calmodulin-Dependent Protein Kinases/metabolism , Myocytes, Cardiac/metabolism , Sodium Channels/physiology , Action Potentials/physiology , Adenoviridae/genetics , Animals , Arrhythmias, Cardiac/physiopathology , Blotting, Western , Calcium-Calmodulin-Dependent Protein Kinases/antagonists & inhibitors , Calcium-Calmodulin-Dependent Protein Kinases/genetics , Gene Expression Regulation, Enzymologic/genetics , Immunoprecipitation , Mice , Mice, Transgenic , Myocytes, Cardiac/cytology , Myocytes, Cardiac/physiology , Patch-Clamp Techniques , Phosphorylation , Protein Binding , Rabbits , Sodium Channels/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...