1.
Ann Card Anaesth
; 21(3): 321-322, 2018.
Article
in English
| MEDLINE
| ID: mdl-30052228
ABSTRACT
High Doppler valve gradient is generally suggestive of valve thrombosis. However, it should be corroborated with the finding of restricted leaflet movement to confirm the diagnosis. In the present case, abnormally high gradient was not associated with limited leaflet movements or any valve thrombus.
Subject(s)
Bioprosthesis , Heart Valve Prosthesis , Mitral Valve/diagnostic imaging , Cardiotonic Agents/adverse effects , Cardiotonic Agents/therapeutic use , Diagnosis, Differential , Digoxin/adverse effects , Digoxin/therapeutic use , Echocardiography, Transesophageal , Female , Humans , Middle Aged , Thrombosis/diagnostic imaging , Tricuspid Valve Insufficiency/surgery