Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Waste Manag Res ; 41(2): 303-311, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35796352

ABSTRACT

This article presents a bi-objective mixed-integer linear model for the waste management system design. Two types of facilities, landfills and transfer stations (TSs), are identified based on two objectives: minimising the total system's costs and the total negative impact of located facilities on end users as waste generators through a defined pollution decay function. Landfills and TSs are categorised as undesirable facilities due to associated environmental risks. In this article undesirability of a located facility is defined as a two-threshold linear decreasing function of the distance between the end users and the located facility. Also, we considered additional restrictions that no two selected landfills or TSs are within a pre-specified distance from each other, limiting the superimposed pollution generated in these facilities. The model performances are tested on a real-scale example for Vojvodina (Serbia). Results showed that the proposed model has potentials and can be beneficial for government organisations, local authorities and other organisations related to waste management issues.


Subject(s)
Refuse Disposal , Waste Management , Refuse Disposal/methods , Serbia , Yugoslavia , Waste Disposal Facilities , Solid Waste
2.
Waste Manag Res ; 30(6): 635-8, 2012 Jun.
Article in English | MEDLINE | ID: mdl-22081381

ABSTRACT

In 2007, the Serbian Ministry of Health initiated specific activities towards establishing a workable model based on the existing administrative framework, which corresponds to the needs of healthcare waste management throughout Serbia. The objective of this research was to identify the reforms carried out and their outcomes by estimating the efficiencies of a sample of 35 healthcare facilities engaged in the process of collection and treatment of healthcare waste, using data envelopment analysis. Twenty-one (60%) of the 35 healthcare facilities analysed were found to be technically inefficient, with an average level of inefficiency of 13%. This fact indicates deficiencies in the process of collection and treatment of healthcare waste and the information obtained and presented in this paper could be used for further improvement and development of healthcare waste management in Serbia.


Subject(s)
Efficiency, Organizational , Health Facility Administration , Medical Waste Disposal , Serbia
SELECTION OF CITATIONS
SEARCH DETAIL
...