1.
Article in English | MEDLINE | ID: mdl-34200369

ABSTRACT

Background: In some hospitals in low/middle-income countries, methods to determine the bilirubin level in newborn infants are unavailable and based on a clinical evaluation, namely a clinical score designed by Kramer. In this study, we evaluated if this score can be used to identify those infants that need phototherapy. Method: Infants admitted between November 2018 and June 2019 to three hospitals in Surabaya, Indonesia were included. The jaundice intensity was scored using the Kramer score. Blood was sampled for total serum bilirubin (TSB) measurement. The infants were categorized into Treatment Needed (TN) group when treatment with phototherapy was indicated and the No Treatment Needed (NTN) group when phototherapy was not indicated, based on the Indonesian Guideline for hyperbilirubinemia. Result: A total of 280 infants with a mean birth weight of 2744.6 ± 685.8 g and a gestational age of 37.3 ± 2.3 weeks were included. Twenty-seven of 113 (24%) infants with Kramer score 2 needed phototherapy, compared with 41 of 90 (46%) infants with score 3 and 20 of 28 (71%) of infants with score 4. The percentage of infants that needed phototherapy was higher with decreasing gestational age. Conclusion: The Kramer score is an invalid method to distinguish between those infants needing phototherapy and those infants where this treatment is not indicated.


Subject(s)
Jaundice, Neonatal , Bilirubin , Humans , Hyperbilirubinemia , Indonesia , Infant , Infant, Newborn , Phototherapy
2.
Heliyon ; 6(9): e04950, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32995629

ABSTRACT

INTRODUCTION: A range of phototherapy devices are commercially available. The American Academy of Pediatrics (2004) recommends routine intensity measurement of phototherapy devices to ensure that babies affected by hyperbilirubinemia receive effective phototherapy. OBJECTIVE: The aims of this study were to calculate the irradiance decay velocity of phototherapy devices used in a tertiary care hospital to evaluate whether current maintenance procedures for phototherapy devices are effective, and to contribute to the improvement of a standardized maintenance procedure in daily practice, thus helping to ensure that all babies affected by hyperbilirubinemia receive prompt treatment. METHODS: This research represents a prospective observational study conducted at Dr. Soetomo Academic Teaching Hospital in Surabaya, Indonesia from February 2019-July 2019. The intensities of 11 phototherapy devices were measured at specific times using a Bili Blanket Meter II. We calculated the Δ irradiance differences in µW/cm2/nm and calculated them as velocity µW/cm2/nm/hour of use. RESULTS: Among the 11 phototherapy devices included in this study, nine were fluorescent and two were light-emitting diode (LED) machines. The mean (standard deviation) irradiance decay velocity of the fluorescent lamps was 0.02 (±0.03) µW/cm2/nm/hour of use, while that of the LED lamps was 0.015 (±0.007) µW/cm2/nm/hour of use. The fastest irradiance decay velocity was 0.08 µW/cm2/nm/hour of use, while the slowest irradiance decay velocity was <0.01 µW/cm2/nm/hour of use, both of which were from fluorescent-based devices. There was one fluorescent-based device that provided an intensity lower than the therapeutic level. CONCLUSION: Irradiance decay occurred in all phototherapy device lamps. It is important to perform routinely intensity measurements, regardless of manufacturer recommendations, to avoid ineffective phototherapy resulting from intensities lower than the required therapeutic levels.

SELECTION OF CITATIONS
SEARCH DETAIL
...