Subject(s)
Anti-Ulcer Agents/therapeutic use , Peptic Ulcer/prevention & control , Peptic Ulcer/therapy , Quality Improvement , Stress, Physiological , Stress, Psychological/complications , Acute Disease , Adult , Aged , Anti-Ulcer Agents/economics , Australia , Humans , Intensive Care Units , Middle Aged , Patient Education as Topic , Peptic Ulcer/economics , Pharmacists , Prospective Studies , Proton Pump Inhibitors/economics , Proton Pump Inhibitors/therapeutic useABSTRACT
Kidney transplantation from a hepatitis C virus (HCV)-positive donor to an HCV-negative recipient till recently has been a contraindication. In view of the excellent sustained virological response (SVR) rates with directly acting antiviral agents, HCV-positive donors are being considered for the HCV-negative recipients in a few centers. We report the successful transplantation of an HCV-negative recipient transplanted with an HCV-positive donor kidney. Donor was treated with sofosbuvir and ribavirin for 12 weeks. At 10th and 16th weeks of starting treatment, her HCV-RNA PCR was negative. Three weeks later, transplantation was performed with basiliximab induction and triple immunosuppression with tacrolimus, mycophenolate, and prednisolone. The recipient was administered sofosbuvir and ribavirin for 12 weeks. He attained good graft function with a stable creatinine. His serial alanine transaminases were normal on 3rd, 6th, and 12th months, respectively. Six months posttransplant his anti-HCV antibody, and HCV-RNA PCR were negative.
ABSTRACT
AIM: Distortion due to Polymerization shrinkage compromises the retention. To evaluate the amount of retention of denture bases fabricated by conventional, anchorized, and injection molding polymerization techniques. MATERIALS AND METHODS: Ten completely edentulous patients were selected, impressions were made, and master cast obtained was duplicated to fabricate denture bases by three polymerization techniques. Loop was attached to the finished denture bases to estimate the force required to dislodge them by retention apparatus. Readings were subjected to nonparametric Friedman two-way analysis of variance followed by Bonferroni correction methods and Wilcoxon matched-pairs signed-ranks test. RESULTS: Denture bases fabricated by injection molding (3740 g), anchorized techniques (2913 g) recorded greater retention values than conventional technique (2468 g). Significant difference was seen between these techniques. CONCLUSIONS: Denture bases obtained by injection molding polymerization technique exhibited maximum retention, followed by anchorized technique, and least retention was seen in conventional molding technique.