Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Heliyon ; 10(9): e30030, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38707442

ABSTRACT

Objective: To investigate the knowledge of diagnostic reference levels (DRLs), image quality, radiation dose and protocol parameters among Jordanian medical imaging professionals (MIPs) involved in PET/CT and CT scan procedures. Materials and methods: A questionnaire was designed and distributed to MIPs in Jordan. The survey comprised four sections: demographic data, MIP knowledge on dose/protocol parameters, image quality, and DRLs. Statistical analyses were performed utilizing Pearson's correlation, t-tests, ANOVA, and linear regression, with a significance level of 95 % and a p-value threshold of <0.05. Results: The study involved 147 participants. Most respondents were male (76.2 %), and most were aged 26-35 years (44.2 %). Approximately 51 % held a bachelor's degree, and the most common range of experience was 3-5 years (28.6 %). Participants showed a moderate level of knowledge regarding dose and protocol parameters, with a mean score of 61.8 %. The mean scores for knowledge of image quality and DRLs were 45.2 % and 44.8 %, respectively. The age group of the MIPs and the total experience were found to have a significant impact on the knowledge of the dose and protocol parameters, as well as the DRLs. Additionally, experience was found to have a significant influence on knowledge of the dose and protocol parameters. The study revealed a positive and significant effect of MIPs' knowledge of dose/protocol parameters and image quality on their knowledge of DRLs. Conclusions: This study indicates that professionals across five specialties who are engaged in PET/CT and CT imaging possess a moderate understanding of dosage and protocol parameters. However, there is a notable gap in knowledge regarding DRLs and image quality. To address this issue, it is recommended that MIPs actively engage in educational programs emphasizing exposure parameters and their impact on image quality. Additionally, access to comprehensive education and training programs will enable MIPs to grasp the complexities of DRLs and their implications, facilitating their implementation in clinical practice.

2.
Curr Radiopharm ; 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38571349

ABSTRACT

BACKGROUND: Despite the escalated production rate, the Iodinated Contrast Media (ICM) shortage continues, and demand outweighs supply. AIM: The aim of this study is to investigate the knowledge and practice of ICM delivery in computed tomography (CT) among radiographers and radiologic technologists worldwide. METHODS: An IRB-approved cross-sectional survey used Google Forms for data collection. It involved 94 CT radiographers from 27 countries and was divided into five sections. The first section gathered demographic information, followed by sections on experience, self-assessment of ICM reactions, and delivery technique. The third section explored ICM knowledge and its relation to CT parameters. The fourth and fifth sections focus on practices during pulmonary angiography CT and renal CT scans. Data analysis involved descriptive statistics, the Chi- Square test, and ANOVA. RESULTS: Knowledge was assessed with seven questions, and a score of at least 3.5 was needed for categorization. The median score was two, indicating low knowledge. Specifically, 64.9% of the participants scored lower than the two scores. Years of experience are strongly correlated with the level of knowledge, with 51.6% of radiographers having more than 10 years of experience demonstrating adequate knowledge. 41.7% of respondents demonstrated adequate knowledge when their duty was focused on CT. Furthermore, wide practice variability exists in all CT pulmonary angiography protocols among radiographers with adequate and inadequate knowledge. CONCLUSION: Inexperienced individuals showed knowledge gaps, leading to varied practices and highlighting the need for educational programs. The study underscores establishing standardized Protocols and Practice Guidelines (PPGs) for contrast media administration in Radiology Departments. Additionally, it emphasizes the importance of regular training programs, and international knowledge sharing. The potential for self-selection bias in the online survey sample is highlighted.

3.
Int J Biomed Imaging ; 2024: 7001343, 2024.
Article in English | MEDLINE | ID: mdl-38496776

ABSTRACT

Background: Artificial intelligence (AI) applications are rapidly advancing in the field of medical imaging. This study is aimed at investigating the perception and knowledge of radiographers towards artificial intelligence. Methods: An online survey employing Google Forms consisting of 20 questions regarding the radiographers' perception of AI. The questionnaire was divided into two parts. The first part consisted of demographic information as well as whether the participants think AI should be part of medical training, their previous knowledge of the technologies used in AI, and whether they prefer to receive training on AI. The second part of the questionnaire consisted of two fields. The first one consisted of 16 questions regarding radiographers' perception of AI applications in radiology. Descriptive analysis and logistic regression analysis were used to evaluate the effect of gender on the items of the questionnaire. Results: Familiarity with AI was low, with only 52 out of 100 respondents (52%) reporting good familiarity with AI. Many participants considered AI useful in the medical field (74%). The findings of the study demonstrate that nearly most of the participants (98%) believed that AI should be integrated into university education, with 87% of the respondents preferring to receive training on AI, with some already having prior knowledge of AI used in technologies. The logistic regression analysis indicated a significant association between male gender and experience within the range of 23-27 years with the degree of familiarity with AI technology, exhibiting respective odds ratios of 1.89 (COR = 1.89) and 1.87 (COR = 1.87). Conclusions: This study suggests that medical practices have a favorable attitude towards AI in the radiology field. Most participants surveyed believed that AI should be part of radiography education. AI training programs for undergraduate and postgraduate radiographers may be necessary to prepare them for AI tools in radiology development.

4.
J Radiol Prot ; 44(1)2024 Mar 07.
Article in English | MEDLINE | ID: mdl-38387102

ABSTRACT

This study aims to report the findings of Jordanian national diagnostic reference level (NDRL) survey for fluorodeoxyglucose (18F-FDG) and local diagnostic reference level (LDRL) of computed tomography (CT) used for attenuation correction and anatomical localisation (AC-AL); and AC and diagnostic CT (AC-DX) within the context of whole-body WB and half-body HB adult oncology PET/CT scanning. Two-structured questionnaires were prepared to gather the necessary information: dosimetry data, patient demographics, equipment specification, and acquisition protocols for identified18F-FDG PET/CT procedures. The NDRL and achievable dose were reported based on the 75th and 50th percentiles for18F-FDG administered activity (AA), respectively. The LDRL was reported based on the 50th percentile for (CTDIvol) and (DLP). Data from 562 patients from four Jordanian PET/CT centres were collected. The survey revealed that Jordanian NDRL for AA (303 MBq) was within the acceptable range compared to the published-peer NDRL data (240-590 MBq). However, the18F-FDG AA varied across the participated PET/CT centres. The reported LDRL CTDIvoland DLP of CT used for (AC-AL) was 4.3 mGy and 459.3 mGy.cm for HB CT scan range, and 4.1 mGy and 659.9 mGy.cm for WB CT scans. The reported LDRL for CTDIvoland DLP for HB CT was higher when compared with the United Kingdom (3.2 mGy and 310 mGy.cm). Concurrently, in the context of WB CT, the reported values (i.e. CTDIvol and DLP) were also higher than both Kuwait (3.6 mGy and 659 mGy.cm) and Slovenia (3.6 mGy and 676 mGy.cm). The reported HB CT(AC-DX) was higher than Nordic, New Zealand and Swiss NDRLs and for WB (AC-DX) CT it was higher than Swiss NDRLs. This study reported the first Jordanian NDRL for18F-FDG and LDRL for HB and WB CT associated with18F-FDG PET/CT scans. This data is useful for Jordanian PET/CT centres to compare their LDRL to the suggested DRLs and utilise it in the process of optimising CT radiation doses.


Subject(s)
Fluorodeoxyglucose F18 , Positron Emission Tomography Computed Tomography , Adult , Humans , Diagnostic Reference Levels , Radiation Dosage , Jordan , Reference Values , Tomography, X-Ray Computed
5.
J Xray Sci Technol ; 32(3): 725-734, 2024.
Article in English | MEDLINE | ID: mdl-38189739

ABSTRACT

BACKGROUND: To reduce radiation dose and subsequent risks, several legislative documents in different countries describe the need for Diagnostic Reference Levels (DRLs). Spinal radiography is a common and high-dose examination. Therefore, the aim of this work was to establish the DRL for Computed Tomography (CT) examinations of the spine in healthcare institutions across Jordan. METHODS: Data was retrieved from the picture archiving and communications system (PACS), which included the CT Dose Index (CTDI (vol) ) and Dose Length Product (DLP). The median radiation dose values of the dosimetric indices were calculated for each site. DRL values were defined as the 75th percentile distribution of the median CTDI (vol)  and DLP values. RESULTS: Data was collected from 659 CT examinations (316 cervical spine and 343 lumbar-sacral spine). Of the participants, 68% were males, and the patients' mean weight was 69.7 kg (minimum = 60; maximum = 80, SD = 8.9). The 75th percentile for the DLP of cervical and LS-spine CT scans in Jordan were 565.2 and 967.7 mGy.cm, respectively. CONCLUSIONS: This research demonstrates a wide range of variability in CTDI (vol)  and DLP values for spinal CT examinations; these variations were associated with the acquisition protocol and highlight the need to optimize radiation dose in spinal CT examinations.


Subject(s)
Radiation Dosage , Spine , Tomography, X-Ray Computed , Humans , Jordan , Tomography, X-Ray Computed/methods , Tomography, X-Ray Computed/standards , Male , Female , Adult , Middle Aged , Spine/diagnostic imaging , Aged , Benchmarking , Diagnostic Reference Levels , Adolescent , Young Adult , Child , Aged, 80 and over
6.
Nucl Med Commun ; 44(11): 937-943, 2023 Nov 01.
Article in English | MEDLINE | ID: mdl-37615527

ABSTRACT

PET-computed tomography (PET/CT) is a hybrid imaging technique that combines anatomical and functional information; to investigate primary cancers, stage tumours, and track treatment response in paediatric oncology patients. However, there is debate in the literature about whether PET/CT could increase the risk of cancer in children, as the machine is utilizing two types of radiation, and paediatric patients have faster cell division and longer life expectancy. Therefore, it is essential to minimize radiation exposure by justifying and optimizing PET/CT examinations and ensure an acceptable image quality. Establishing diagnostic reference levels (DRLs) is a crucial quantitative indicator and effective tool to optimize paediatric imaging procedures. This review aimed to distinguish and acknowledge variations among published DRLs for paediatric patients in PET/CT procedures. A search of relevant articles was conducted using databases, that is, Embase, Scopus, Web of Science, and Medline, using the keywords: PET-computed tomography, computed tomography, PET, radiopharmaceutical, DRL, and their synonyms. Only English and full-text articles were included, with no limitations on the publication year. After the screening, four articles were selected, and the review reveals different DRL approaches for paediatric patients undergoing PET/CT, with primary variations observed in patient selection criteria, reporting of radiation dose values, and PET/CT equipment. The study suggests that future DRL methods for paediatric patients should prioritize data collection in accordance with international guidelines to better understand PET/CT dose discrepancies while also striving to optimize radiation doses without compromising the quality of PET/CT images.


Subject(s)
Diagnostic Reference Levels , Positron Emission Tomography Computed Tomography , Child , Humans , Positron Emission Tomography Computed Tomography/methods , Radiation Dosage , Tomography, X-Ray Computed , Radiopharmaceuticals , Reference Values
7.
Eur J Radiol Open ; 10: 100498, 2023.
Article in English | MEDLINE | ID: mdl-37359179

ABSTRACT

Rationale and objectives: to investigate the relationship between radiologists' experience in reporting mammograms, their caseloads, and the classification of category '3' or 'Probably Benign' on normal mammograms. Materials and Methods: A total of 92 board-certified radiologists participated. Self-reported parameters related to experience, including age, years since qualifying as a radiologist, years of experience reading mammograms, number of mammograms read per year, and hours spent reading mammograms per week, were documented. To assess the radiologists' accuracy, "Probably Benign fractions" was calculated by dividing the number of "Probably Benign findings" given by each radiologist in the normal cases by the total number of normal cases Probably Benign fractions were correlated with various factors, such as the radiologists' experience. Results: The results of the statistical analysis revealed a significant negative correlation between radiologist experience and 'Probably Benign' fractions for normal images. Specifically, for normal cases, the number of mammograms read per year (r = -0.29, P = 0.006) and the number of mammograms read over the radiologist's lifetime (r = -0.21, P = 0.049) were both negatively correlated with 'Probably Benign' fractions. Conclusion: The results indicate that a relationship exists between increased reading volumes and reduced assessments of 'Probably Benign' in normal mammograms. The implications of these findings extend to the effectiveness of screening programs and the recall rates.

8.
Acta Radiol ; 64(2): 829-836, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35505591

ABSTRACT

BACKGROUND: Increased radiation doses from computed tomography (CT) examinations is well known with proven risks of inducing cancers for effective dose >100 mSv (according to some studies >50 mSvs). PURPOSE: To establish the diagnostic reference level (DRL) for low-dose renal CT examinations in the evaluation of renal stones. MATERIAL AND METHODS: Patient demographics, CT parameters, and dosimetric indices (CTDIvol and dose length product [DLP]) were collected from 12 tertiary hospitals that routinely perform renal CT in the detection and evaluation of renal stones over a period of 12 weeks. Data obtained from 1418 average-sized patients in each category were recorded. The median values of dosimetric indices for each site were calculated. The DRL values were defined as the 75th percentile of the distribution of the median values of CTDIvol and DLP. RESULTS: There were no significant differences between patient demographics. Mean kVp and mAs for protocols were 121.67 ± 11.56 and 226.91 ± 78.44, respectively. The CTDIvol values were in the range of 2-36.2 mGy, while the DLP values were in the range of 43-1942 mGy.cm. The DRL for the CTDIvol was 16.15 mGy and for the DLP 851.77 mGy.cm. The local median values of CDTIvol and DLP are higher than DRL in two hospitals. CONCLUSION: Comparison of local median values of CDTIvol and DLP with DRL suggests the needs of an optimization strategy in some hospitals.


Subject(s)
Diagnostic Reference Levels , Tomography, X-Ray Computed , Humans , Radiation Dosage , Tomography, X-Ray Computed/methods , Tertiary Care Centers , Reference Values
9.
Int J Gen Med ; 15: 3517-3524, 2022.
Article in English | MEDLINE | ID: mdl-35392029

ABSTRACT

Objective: We aim to report our heart team's experience in repair of Secundum atrial septal defect (ASD) in adolescent and adult patients at Jordan University Hospital (JUH). Methodology: A retrospective observational study of 44 patients who underwent secundum ASD closure by transcatheter closure (TCC) or Minimally Invasive Cardiac Surgery (MICS) at JUH. Patients who were treated at an age of 14 years or older regardless of the age of diagnosis were included. SPSS and Microsoft Excel were used to analyze the data. Results: A total of 44 patients with secundum ASD were treated during the period of (January 2015 and December 2019). The mean age was 34.1 (±14.3) years. Thirty-four patients underwent TCC, 9 underwent surgical closure and one had a hybrid procedure. We had no mortality and 2 minor morbidities. After a mean follow-up period of 13.2-/+13.6 months, most patients experienced improved symptoms, and there was a significant reduction of right ventricular dimension from 33.1 (±8.74) to 24 (±4.67) mm (p=0.0001). Conclusion: ASD closure whether TCC or MICS is a safe procedure with very low morbidity. A heart team approach is a necessity in the era of advances in both MICS surgery and TCC approach. A heart team provides the patients with a variety of safe and cosmetic solutions that allow the patients to have a fast management and recovery phase in rapid time through providing the merits and avoiding the complications of each modality, the team allows low volume centers in developing countries to achieve an excellent outcome.

10.
Pediatr Gastroenterol Hepatol Nutr ; 24(4): 325-336, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34316467

ABSTRACT

The occurrence of functional gastrointestinal disorders (FGIDs) is a formidable challenge for infants, parents, and healthcare professionals. Although data from the Middle East are scarce, experts consider FGIDs a prevalent condition in everyday clinical practice. The new Rome IV criteria revisited the definitions from a clinical perspective to provide a practical and consistent diagnostic protocol for FGIDs. However, the treatment practices for functional disorders vary considerably among Middle Eastern countries, often resulting in mismanagement with unnecessary investigations and treatments. In addition, the role of various treatment modalities, including probiotics such as Lactobacillus reuteri DSM 17938, in FGIDs requires further discussion and evaluation. During a consensus meeting, a locally relevant approach for treating common FGIDs such as infant regurgitation, infant colic, and functional constipation was discussed and approved by regional experts. The participants suggested a simplified treatment plan and protocol for general pediatricians and other primary care physicians managing FGIDs. This easy-to-follow standardized protocol will help streamline the initial management of this complex disorder in the Middle East region and even globally.

11.
Int Arch Otorhinolaryngol ; 25(1): e98-e107, 2021 Jan.
Article in English | MEDLINE | ID: mdl-33542759

ABSTRACT

Introduction One of the main factors that affect the early diagnosis and intervention of hearing loss is inadequate knowledge by the health care workers. Ear, nose, and throat (ENT) specialists are the main source of information about hearing loss and its management in most developing countries, such as Jordan. Objective The purpose of the present study is to explore the level of knowledge and the practice of hearing screening and hearing loss management for children among ENT physicians in Jordan as an example of health care providers in developing countries of the Middle East. Methods This was a cross-sectional study, adapting a questionnaire of knowledge and the practice of hearing screening and hearing loss management for children. The questionnaire consisted of 2 sections with 20 questions. A total of 40 ENT physicians completed the questionnaire. Results The majority of the respondents acknowledged the importance of hearing screening for children; however, there was limited knowledge regarding hearing loss management and testing. Only 10 of the ENT physicians believed that a referral to an audiologist is warranted, and the majority of the respondents were not aware that a child with a confirmed permanent hearing loss should be referred to a speech pathologist or to a rehabilitation center. Managing unilateral and mild sensorineural hearing loss (SNHL) was another area about which ENT physicians have limited knowledge. Conclusion There is a strong need for professional intervention programs, providing the latest updates and standardizations in the field of audiology and pediatric rehabilitation for ENT physicians.

12.
Int. arch. otorhinolaryngol. (Impr.) ; 25(1): 98-107, Jan.-Mar. 2021. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1154428

ABSTRACT

Abstract Introduction One of the main factors that affect the early diagnosis and intervention of hearing loss is inadequate knowledge by the health care workers. Ear, nose, and throat (ENT) specialists are the main source of information about hearing loss and its management in most developing countries, such as Jordan. Objective The purpose of the present study is to explore the level of knowledge and the practice of hearing screening and hearing loss management for children among ENT physicians in Jordan as an example of health care providers in developing countries of the Middle East. Methods This was a cross-sectional study, adapting a questionnaire of knowledge and the practice of hearing screening and hearing loss management for children. The questionnaire consisted of 2 sections with 20 questions. A total of 40 ENT physicians completed the questionnaire. Results The majority of the respondents acknowledged the importance of hearing screening for children; however, there was limited knowledge regarding hearing loss management and testing. Only 10 of the ENT physicians believed that a referral to an audiologist is warranted, and the majority of the respondents were not aware that a child with a confirmed permanent hearing loss should be referred to a speech pathologist or to a rehabilitation center. Managing unilateral and mild sensorineural hearing loss (SNHL) was another area about which ENT physicians have limited knowledge. Conclusion There is a strong need for professional intervention programs, providing the latest updates and standardizations in the field of audiology and pediatric rehabilitation for ENT physicians.

13.
Radiol Med ; 126(3): 380-387, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32897493

ABSTRACT

This article aims to summarize the available data on the severe acute respiratory syndrome coronavirus 2 (SAR-CoV-2) imaging patterns as well as reducing radiation dose exposure in chest computed tomography (CT) protocols. First, the general aspects of radiation dose in CT and radiation risk are discussed, followed by the effect of changing parameters on image quality. This article attempts to highlight some of the common chest CT signs that radiologists and emergency physicians are likely to encounter. With the increasing trend of using chest CT scans as an imaging tool to diagnose and monitor SAR-CoV-2, we emphasize that pattern recognition is the key, and this pictorial essay should serve as a guide to help establish correct diagnosis coupled with correct scanner parameters to reduce radiation dose without affecting imaging quality in this tragic pandemic the world is facing.


Subject(s)
COVID-19/diagnostic imaging , Lung/diagnostic imaging , Radiation Dosage , Radiation Exposure/prevention & control , Tomography, X-Ray Computed , Humans
14.
Acta Radiol ; 62(6): 707-714, 2021 Jun.
Article in English | MEDLINE | ID: mdl-32623914

ABSTRACT

BACKGROUND: The low subject contrast between cancerous and fibroglandular tissue could obscure breast abnormalities. PURPOSE: To investigate radiologists' performance for detection of breast cancer in low and high mammographic density (MD) when cases are digitally acquired. MATERIAL AND METHODS: A test set of 60 digital mammography cases, of which 20 were cancerous, were examined by 17 radiologists. Mammograms were categorized as low (≤50%) or high (>50%) MD and rated for suspicion of malignancy using the Royal Australian and New Zealand College of Radiology (RANZCR) classification system. Radiologist demographics including cases read per year, age, subspecialty, and years of reporting were recorded. Radiologist performance was analyzed by the following metrics: sensitivity; specificity; area under the receiver operating characteristic (ROC) curve (AUC), location sensitivity, and jackknife free-response ROC (JAFROC) figure of merit (FOM). RESULTS: Comparing high to low MD cases, radiologists showed a significantly higher sensitivity (P = 0.015), AUC (P = 0.003), location sensitivity (P = 0.002), and JAFROC FOM (P = 0.001). In high compared to low MD cases, radiologists with <1000 annual reads and radiologists with no mammographic subspecialty had significantly higher AUC, location sensitivity, and JAFROC FOM. Radiologists with ≥1000 annual reads and radiologists with mammography subspecialty demonstrated a significant increase in location sensitivity in high compared to low MD cases. CONCLUSION: In this experimental situation, radiologists' performance was higher when reading cases with high compared to low MD. Experienced radiologists were able to precisely localize lesions in breasts with higher MD. Further studies in unselected screening materials are needed to verify the results.


Subject(s)
Breast Density , Breast Neoplasms/diagnostic imaging , Clinical Competence/statistics & numerical data , Mammography/methods , Mammography/statistics & numerical data , Adult , Aged , Breast/diagnostic imaging , Humans , Jordan , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
15.
J Xray Sci Technol ; 28(6): 1025-1035, 2020.
Article in English | MEDLINE | ID: mdl-32986646

ABSTRACT

BACKGROUND: Computed Tomographic (CT) imaging procedures have been reported as the main source of radiation in diagnostic procedures compared to other modalities. To provide the optimal quality of CT images at the minimum radiation risk to the patient, periodic inspections and calibration tests for CT equipment are required. These tests involve a series of measurements that are time consuming and may require specific skills and highly-trained personnel. OBJECTIVE: This study aims to develop a new computational tool to estimate the dose of CT radiation outputs and assist in the calibration of CT scanners. It may also provide an educational resource by which radiological practitioners can learn the influence of technique factors on both patient radiation dose and the produced image quality. METHODS: The computational tool was developed using MATLAB in order to estimate the CT radiation dose parameters for different technique factors. The CT radiation dose parameters were estimated from the calibrated energy spectrum of the x-ray tube for a CT scanner. RESULTS: The estimated dose parameters and the measured values utilising an Adult CT Head Dose Phantom showed linear correlations for different tube voltages (80 kVp, 100 kVp, 120 kVp, and 140 kVp), with R2 nearly equal to 1 (0.99). The maximum differences between the estimated and measured CTDIvol were under 5 %. For 80 kVp and low tube currents (50 mA, 100 mA), the maximum differences were under 10%. CONCLUSIONS: The prototyped computational model provides a tool for the simulation of a machine-specific spectrum and CT dose parameters using a single dose measurement.


Subject(s)
Decision Making, Computer-Assisted , Phantoms, Imaging , Radiation Dosage , Tomography, X-Ray Computed/methods , Adult , Head/diagnostic imaging , Humans
16.
Med Sci (Basel) ; 8(3)2020 Jul 20.
Article in English | MEDLINE | ID: mdl-32698332

ABSTRACT

Computed tomography (CT) is a key imaging technique in diagnostic radiology, providing highly sensitive and specific information. While its use has increased dramatically in recent years, the quantity and associated risks of radiation from CT scans present major challenges, particularly in paediatrics. The fundamental principles of radiation protection require that radiation quantities be as low as reasonably achievable and CT use must be justified, particularly for paediatric patients. CT radiation knowledge is a key factor in optimising and minimising radiation risk. The objective of this study was to analyse knowledge level, expertise, and competency regarding CT radiation dose and its hazards in paediatrics among radiologists in Saudi Arabian hospitals. A self-reported, multiple-choice questionnaire assessed the attitudes and opinions of radiologists involved in imaging studies using ionising radiation. Among the total respondents, 65% ± 13.5% had a good comprehension of the dangers of carcinogenicity to the patient resulting from CT scans, with 80% presuming that cancer risks were elevated. However, only 48.5%, 56.5%, and 65% of the respondents were aware of specific radiation risks in head, chest, and abdominal paediatric examinations, respectively. Regular, frequent, and specific training courses are suggested to improve the fundamental knowledge of CT radiation among radiologists and other physicians.

17.
Breast Cancer (Auckl) ; 14: 1178223420921381, 2020.
Article in English | MEDLINE | ID: mdl-32523348

ABSTRACT

PURPOSE: To document the mammographic breast density (MBD) distribution of Jordanian women and the relationship with MBD with age. Correlation between breast cancer diagnosis and density was also explored. METHODS: A retrospective review of 660 screening mammograms from King Abdullah University Hospital was conducted. Mammograms were classified into 2 groups: normal (return to routine screening) and breast cancer and rated using the American College of Radiology (ACR) Breast Imaging-Reporting and Data System (BI-RADS) 5th edition for MBD. The association between MBD and age was assessed by descriptive analyses and Kruskal-Wallis test. To compare between normal and breast cancer groups, chi-square post hoc tests with Bonferroni adjustment was used. RESULTS: Groups consisted of 73.9% (n = 488) normal group and 26.1% (n = 172) breast cancer group. A significant inverse relationship was demonstrated between age and MBD among the normal (r = -.319, P < .01) and breast cancer group (r = -.569, P < .01). In total, 69% (n = 336) of women in the normal group and 71% (n = 122) in the breast cancer group and 79.1% (n = 159) of the normal group and 100% (n = 48) of the breast cancer group aged 40 to 49 years reported high MBD (ACR BI-RADS c or d). CONCLUSIONS: Most of women in both the normal and breast cancer groups evidenced increased MBD. Increased MBD was inversely proportional to age. As MBD has a known link to increased breast cancer risk and the decreased sensitivity of mammography and it is vital that future screening guidelines for Jordanian women consider the unique breast density distribution of this population.

18.
J Med Radiat Sci ; 67(4): 277-283, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32578380

ABSTRACT

INTRODUCTION: Mammographic breast density is associated with a four to six times increased risk for breast cancer. Mammographic breast density varies by ethnicity, geographical region and age. The aim of this study was to document for the first time the mammographic breast density of Jordanian women and to explore its relationship with age. METHODS: Mammograms completed at King Abdullah University Hospital (Irbid, Jordan) between January 2016 and August 2018 were retrospectively reviewed and classified for breast density using the American College of Radiology (ACR) Breast Imaging-Reporting and Data System (BI-RADS). Descriptive analyses and Kurskal-Wallis test were used to examine the association between age and mammographic breast density. RESULTS: A total of 659 mammograms were reviewed. A significant inverse relationship was observed between age and breast density (P < 0.001). In women aged 40-49 years, 83.2% had dense breasts (ACR BI-RADS (c) and (d)). This percentage decreased to 59.8% of women aged 50-59 years; 38.4% of women in their 60s and 37.9% of women aged 70 years or older (ACR BI-RADS (c) only). CONCLUSION: The mammographic breast density of Jordanian women has been shown to be high across all age groups. Increased mammographic breast density is associated with increased breast cancer risk and renders mammography a less effective technique for the early detection of breast cancer. Breast cancer screening of Jordanian women should be individualised to develop screening protocols and include additional adjunct imaging to best manage women at high risk.


Subject(s)
Breast Density , Breast Neoplasms/diagnostic imaging , Mammography , Mass Screening , Adult , Aged , Female , Humans , Jordan , Middle Aged
19.
J Radiol Prot ; 40(3): R71-R98, 2020 Sep.
Article in English | MEDLINE | ID: mdl-32203948

ABSTRACT

Computed tomography (CT) is a routinely employed diagnostic tool for the detection and diagnosis of disease processes. Despite the primary focus of radiation dose reduction and improvements in CT scanners, radiation dose exposure remains an ever-increasing concern. Scanning protocol optimisation relative to body weight and scanner manufacturer still lags behind the diagnostic reference levels (DRLs) that are set on an international scale. The aim of this systematic review is to evaluate the current status of adult DRLs in head, chest and abdominopelvic CT over time on a global scale. A search was carried out in early 2019 using the Medline, PubMed, EMBASE, SCOPUS and manual databases. The reference lists of published articles were also assessed to identify further articles. The preferred reporting items for systematic reviews and meta-analyses (PRISMA) methodology was employed to evaluate articles for relevance. Articles were included if they assessed the DRL in head, chest and abdominopelvic scans. The search resulted in 6079 articles, of which 67 were included after a thorough screening process. The literature demonstrates a wide dose variation in reported head, chest and abdominopelvic dose length product (DLP) DRL, ranging from 700-1359, 330-707 and 550-1486 mGy·cm, respectively. Where reported, the volumed CT dose index (CTDIvol) DRL in the head, chest and abdominopelvic studies ranged from 30.4-85.5, 9-15 and 12.3-31 mGy·cm, respectively. The global means were shown to be slightly lower and significantly lower than the reported values of DLP and CTDIvol values for the American College of Radiology and European Commission, respectively. This review emphasises the need for an international standardisation for head and body DRL establishment methods, to provide a more comparable global measurement of dose variations across CT sites as well as regular monitoring of delivered radiation dose to patients.


Subject(s)
Abdomen/diagnostic imaging , Head/diagnostic imaging , Radiation Dosage , Thorax/diagnostic imaging , Tomography, X-Ray Computed , Adult , Humans , Reference Values
20.
J Radiol Prot ; 39(4): 1060-1073, 2019 Aug 28.
Article in English | MEDLINE | ID: mdl-31469115

ABSTRACT

This study aimed to investigate the current status of Diagnostic Reference Levels (DRLs) in paediatric CT across Jordan. The dose data for four main CT examinations (brain, chest, abdominopelvic, and chest, abdomen and pelvis (CAP)) in hospitals and imaging centres (n = 4) were measured. The volume CT dose index (CTDIvol) and Dose Length Product (DLP) values were compared within the different hospitals and age groups (<1 year, 1-4 years, 5-10 years and 11-18 years). DRLs in Jordan were compared to international DRLs. The paediatric population consisted of 1818 children; 61.4% of them were male. There were significant variations between the DRLs for each CT scanner with an up to four-fold difference in dose between hospitals. There were apparent significant differences between Jordan and other countries with the DLPs in Jordan being relatively high. However, for CTDIvol, the values in Jordan were close to those of other countries. This study confirmed variations in the CTDIvol and DLP values of paediatric CT scans in Jordan. These variations were attributed to the different protocols and equipment used. There is a need to optimise paediatric CT examinations doses in Jordan.

SELECTION OF CITATIONS
SEARCH DETAIL
...