Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 5: 16536, 2015 Nov 12.
Article in English | MEDLINE | ID: mdl-26559337

ABSTRACT

The origins of spin exchange in crystalline thin films of Copper Octabutoxy Phthalocyanine (Cu-OBPc) are investigated using Magnetic Circular Dichroism (MCD) spectroscopy. These studies are made possible by a solution deposition technique which produces highly ordered films with macroscopic grain sizes suitable for optical studies. For temperatures lower than 2 K, the contribution of a specific state in the valence band manifold originating from the hybridized lone pair in nitrogen orbitals of the Phthalocyanine ring, bears the Brillouin-like signature of an exchange interaction with the localized d-shell Cu spins. A comprehensive MCD spectral analysis coupled with a molecular field model of a σπ - d exchange analogous to sp-d interactions in Diluted Magnetic Semiconductors (DMS) renders an enhanced Zeeman splitting and a modified g-factor of -4 for the electrons that mediate the interaction. These studies define an experimental tool for identifying electronic states involved in spin-dependent exchange interactions in organic materials.

2.
J Phys Chem Lett ; 6(10): 1834-40, 2015 May 21.
Article in English | MEDLINE | ID: mdl-26263257

ABSTRACT

We present spatially-, temporally- and polarization-resolved dual photoluminescence/linear dichroism microscopy experiments that investigate the correlation between long-range order and the nature of exciton states in solution-processed phthalocyanine thin films. The influence of grain boundaries and disorder is absent in these films because typical grain sizes are 3 orders of magnitude larger than focused excitation beam diameters. These experiments reveal the existence of a delocalized singlet exciton, polarized along the high mobility axis in this quasi-1D electronic system. The strong delocalized π orbitals overlap, controlled by the molecular stacking along the high mobility axis, is responsible for breaking the radiative recombination selection rules. Using our linear dichroism scanning microscopy setup, we further established that a rotation of molecules (i.e., a structural phase transition) that occurs above 100 K prevents the observation of this exciton at room temperature.

3.
Am J Ther ; 21(6): e199-203, 2014.
Article in English | MEDLINE | ID: mdl-23567791

ABSTRACT

The practice of intravascular stenting largely grew out of the concept of stenting the coronaries in acute myocardial infarction. According to the recent United States Renal Data System data registry, there has been a significant increase in endovascular intervention (1.8-fold increase-from 52,380 to 98,148) with a 2.2-fold increase in stent deployment in hemodialysis access (3792-8514). With the increasing use of endovascular stents in the management of dialysis access stenosis, the incidence of stent-related complications has increased significantly. Stent-related complications include stent restenosis, thrombosis (narrowing of the vessel lumen and being a nidus for thombus formation), stent shortening, stent fracture, stent infection, and stent migration. Physiologic variation in the diameter of veins due to respiration, which along with the geometry of the stent, can lead to a shortening lengthening of the stent-resulting in poor wall contact or high-speed impact of shock; in the case of trauma, mechanical bucking can result in tortuous blood vessels thereby resulting in stent migration (however proving this association was not the aim of this article). We report a case of a 44-year-old female with end-stage renal disease on hemodialysis, with stent placement to treat a compromised arteriovenous graft. There have been many cases of stent migration in the past; however, this is the first case of dual stent migration to the heart and pulmonary artery from an unusual (lower extremity) arteriovenous graft location.


Subject(s)
Arteriovenous Shunt, Surgical/methods , Foreign-Body Migration/complications , Prosthesis Failure , Stents/adverse effects , Adult , Female , Heart , Humans , Kidney Failure, Chronic/therapy , Pulmonary Artery/pathology , Renal Dialysis
4.
Arch Med Sci ; 8(6): 957-69, 2012 Dec 20.
Article in English | MEDLINE | ID: mdl-23319967

ABSTRACT

Massive pulmonary embolism (PE) is characterized by systemic hypotension (defined as a systolic arterial pressure < 90 mm Hg or a drop in systolic arterial pressure of at least 40 mm Hg for at least 15 min which is not caused by new onset arrhythmias) or shock (manifested by evidence of tissue hypoperfusion and hypoxia, including an altered level of consciousness, oliguria, or cool, clammy extremities). Massive pulmonary embolism has a high mortality rate despite advances in diagnosis and therapy. A subgroup of patients with nonmassive PE who are hemodynamically stable but with right ventricular (RV) dysfunction or hypokinesis confirmed by echocardiography is classified as submassive PE. Their prognosis is different from that of others with non-massive PE and normal RV function. This article attempts to review the evidence-based risk stratification, diagnosis, initial stabilization, and management of massive and nonmassive pulmonary embolism.

5.
Am J Case Rep ; 13: 62-5, 2012.
Article in English | MEDLINE | ID: mdl-23569490

ABSTRACT

BACKGROUND: Amiodarone, class III anti-arrhythmic was originally introduced to treat angina pectoris, was later approved by FDA in 1985 for the treatment of ventricular arrhythmias. Despite its anti-arrhythmic properties, amiodarone is associated with side effects such as thyroid dysfunction, corneal deposits, bluish skin discoloration, neuropathy and pulmonary toxicity. Amiodarone induced pulmonary toxicity (AIPT) is one of the most serious side effect thus limiting its use. CASE REPORT: We encountered a 66 year old male with early onset AIPT who presented with dyspnea and chest imaging revealed extensive ground-glass opacities throughout lung parenchyma with rapid resolution of these opacities in a week following treatment with corticosteroids. CONCLUSIONS: There have been few case reports of AIPT with complete resolution of ground glass opacities on treatment with corticosteroids, but none demonstrated a rapid response to corticosteroids. Heath care providers should withdraw amiodarone at the earliest suspicion (as illustrated in our case); any delay can potentially be fatal. This case highlights the fact that AIPT is a reversible phenomenon, provided its early recognition and treatment before fibrosis sets in This case also highlights the need to include AIPT in the differential diagnosis in any patient on amiodarone who presents with shortness of breath.

6.
J Nanosci Nanotechnol ; 8(4): 2044-8, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18572612

ABSTRACT

This paper describes the thermal oxidative behavior of atomized iron or atomized cobalt in the presence of multiwalled carbon nanotubes (MWCNT). The thermogravimetric analysis shows the atomized iron thermal oxidation starts at about 500 degrees C that is absent when the atomized iron is sintered with multiwalled carbon naonotubes. The thermal oxidation of iron in the sintered samples requires the collapse of the multiwalled carbon nanotubes. A similar behavior is observed with atomized cobalt when its oxidation requires the collapse of the nanotubes. This thermal oxidative shift is interpreted as due to the atomized iron or atomized cobalt atom experiencing extensive overlap and confinement effect with multiwalled carbon nanotubes causing a spin transfer. This confinement effect is suggested to produce a transformation of iron from the outermost electronic distribution of 3d64s2 to an effective configuration of 3d84s0 and for cobalt 3d74s2 to 3d94s0 producing spintronics effect.


Subject(s)
Crystallization/methods , Magnetics , Models, Chemical , Nanotechnology/methods , Nanotubes, Carbon/chemistry , Nanotubes, Carbon/ultrastructure , Thermogravimetry , Computer Simulation , Macromolecular Substances/chemistry , Materials Testing , Molecular Conformation , Particle Size , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...