1.
Appl Spectrosc ; : 37028241263567, 2024 Jun 16.
Article in English | MEDLINE | ID: mdl-38881037

ABSTRACT

The almost-two-centuries history of spectrochemical analysis has generated a body of literature so vast that it has become nearly intractable for experts, much less for those wishing to enter the field. Authoritative, focused reviews help to address this problem but become so granular that the overall directions of the field are lost. This broader perspective can be provided partially by general overviews but then the thinking, experimental details, theoretical underpinnings and instrumental innovations of the original work must be sacrificed. In the present compilation, this dilemma is overcome by assembling the most impactful publications in the area of analytical atomic spectrometry. Each entry was proposed by at least one current expert in the field and supported by a narrative that justifies its inclusion. The entries were then assembled into a coherent sequence and returned to contributors for a round-robin review.

2.
Mass Spectrom Rev ; 40(5): 647-669, 2021 09.
Article in English | MEDLINE | ID: mdl-32779281

ABSTRACT

Time-of-flight mass spectrometry (TOFMS) is one of the simplest and most powerful approaches for mass spectrometry. Realization of the advantages inherent in TOFMS requires innovation in the theory and practice of the technique. Instrumental developments, in turn, create new capabilities that enable applications in chemical measurement. This review focuses on the recent advances in TOFMS instrumentation. New strategies for ion acceleration, multiplexed detection, miniaturized TOFMS instruments, approaches to extend the length of ion flight, and novel ion detection technologies are reviewed. Techniques that change the basic paradigm of TOFMS by measuring m/z based on ion flight distance are considered, as are applications at the frontiers of instrumental performance. © 2020 John Wiley & Sons Ltd. Mass Spec Rev.

3.
Article in English | MEDLINE | ID: mdl-32573245

ABSTRACT

Enzymatic digestion of proteins is a critical step in bottom-up and middle-down proteomics. Here, we demonstrate a method for decreasing the time required for proteolytic digestion of proteins from multiple hours to minutes by using an in-line microstrip cavity for programmed microwave heating. When a nanospray emitter tip, containing a digestion sample, is exposed to a region of highly focused microwave field, the rate of proteolytic digestion is enhanced and the time required for digestion greatly decreased. The design is advantageous for mass spectrometry because the solution-based digestion can then be directly sprayed from a nanoelectrospray tip emitter, decreasing sample transfer loss and allowing the system to be used in a flow-through proteolytic workflow. Microwave-assisted digestion using this method is evaluated against standard overnight digestion protocols using a variety of proteins, evaluating sequence coverage and observed peptide location, digestion rate, and overall efficacy. The influence of applied microwave power is investigated, and enzymatic kinetic parameters are evaluated to estimate temperature within the microreactor. Finally, the modulation of the proteolytic digestion of proteins based upon the modulation of applied microwave power is demonstrated on a time scale of seconds in a flow-through system.

4.
Anal Chim Acta ; 952: 1-8, 2017 02 01.
Article in English | MEDLINE | ID: mdl-28010838

ABSTRACT

A new direct-current microplasma-based flowing atmospheric pressure afterglow (FAPA) source was developed for use in ambient desorption-ionization mass spectrometry. The annular-shaped microplasma is formed in helium between two concentric stainless-steel capillaries that are separated by an alumina tube. Current-voltage characterization of the source shows that this version of the FAPA operates in the normal glow-discharge regime. A glass surface placed in the path of the helium afterglow reaches temperatures of up to approximately 400 °C; the temperature varies with distance from the source and helium flow rate through the source. Solid, liquid, and vapor samples were examined by means of a time-of-flight mass spectrometer. Results suggest that ionization occurs mainly through protonation, with only a small amount of fragmentation and adduct formation. The mass range of the source was shown to extend up to at least m/z 2722 for singly charged species. Limits of detection for several small organic molecules were in the sub-picomole range. Examination of competitive ionization revealed that signal suppression occurs only at high (mM) concentrations of competing substances.

5.
J Am Soc Mass Spectrom ; 28(2): 263-269, 2017 Feb.
Article in English | MEDLINE | ID: mdl-27757823

ABSTRACT

The flowing atmospheric-pressure afterglow (FAPA) source was used for the mass-spectrometric analysis of vapor samples introduced between the source and mass spectrometer inlet. Through interrupted operation of the plasma-supporting helium flow, helium consumption is greatly reduced and dynamic gas behavior occurs that was characterized by schlieren imaging. Moreover, mass spectra acquired immediately after the onset of helium flow exhibit a signal spike before declining and ultimately reaching a steady level. This initial signal appears to be due to greater interaction of sample vapor with the afterglow of the source when helium flow resumes. In part, the initial spike in signal can be attributed to a pooling of analyte vapor in the absence of helium flow from the source. Time-resolved schlieren imaging of the helium flow during on and off cycles provided insight into gas-flow patterns between the FAPA source and the MS inlet that were correlated with mass-spectral data. Graphical Abstract ᅟ.

6.
Appl Spectrosc ; 71(6): 1280-1288, 2017 Jun.
Article in English | MEDLINE | ID: mdl-27872218

ABSTRACT

Glow discharges have long been used for depth profiling and bulk analysis of solid samples. In addition, over the past decade, several methods of obtaining lateral surface elemental distributions have been introduced, each with its own strengths and weaknesses. Challenges for each of these techniques are acceptable optical throughput and added instrumental complexity. Here, these problems are addressed with a tilting-filter instrument. A pulsed glow discharge is coupled to an optical system comprising an adjustable-angle tilting filter, collimating and imaging lenses, and a gated, intensified charge-coupled device (CCD) camera, which together provide surface elemental mapping of solid samples. The tilting-filter spectrometer is instrumentally simpler, produces less image distortion, and achieves higher optical throughput than a monochromator-based instrument, but has a much more limited tunable spectral range and poorer spectral resolution. As a result, the tilting-filter spectrometer is limited to single-element or two-element determinations, and only when the target spectral lines fall within an appropriate spectral range and can be spectrally discerned. Spectral interferences that result from heterogeneous impurities can be flagged and overcome by observing the spatially resolved signal response across the available tunable spectral range. The instrument has been characterized and evaluated for the spatially resolved analysis of glow-discharge emission from selected but representative samples.

7.
Appl Spectrosc ; 70(11): 1797-1805, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27680086

ABSTRACT

Our research group earlier used dispersion that occurs during flow injection to detect and reduce matrix interference in inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS). In the absence of a matrix interference, the ratio of signals from any two sample constituents should remain constant, independent of the dilution, over the course of a flow-injection transient. However, when an interferent is present, the signal ratio from different analytes will change with dilution, owing to the difference in severity of the interference on specific analytes. As a result, matrix interference can be recognized (flagged) by monitoring the signal ratios of two analytes over the course of a flow-injection transient; a ratio that changes over time indicates the presence of an interferent. The drawback of this earlier method was that dispersion, and therefore dilution, was somewhat element-specific, causing the ratios to wander even when no interference existed. Here, a gradient HPLC pump is used to overcome this drawback by creating a longer, better-controlled dilution. Under these conditions, variation in dispersion between elements is negligible and difficulties associated with it are reduced or eliminated. Further, when an interference exists, the optimal dilution factor to reduce the interference to an acceptable level can be found from the gradient-dilution curve as the point where the signal ratio between two elements becomes constant.

8.
J Am Soc Mass Spectrom ; 27(11): 1772-1786, 2016 11.
Article in English | MEDLINE | ID: mdl-27562501

ABSTRACT

Distance-of-flight mass spectrometry (DOFMS) separates ions of different mass-to-charge (m/z) by the distance they travel in a given time after acceleration. Like time-of-flight mass spectrometry (TOFMS), separation and mass assignment are based on ion velocity. However, DOFMS is not a variant of TOFMS; different methods of ion focusing and detection are used. In DOFMS, ions are driven orthogonally, at the detection time, onto an array of detectors parallel to the flight path. Through the independent detection of each m/z, DOFMS can provide both wider dynamic range and increased throughput for m/z of interest compared with conventional TOFMS. The iso-mass focusing and detection of ions is achieved by constant-momentum acceleration (CMA) and a linear-field ion mirror. Improved energy focus (including turn-around) is achieved in DOFMS, but the initial spatial dispersion of ions remains unchanged upon detection. Therefore, the point-source nature of surface ionization techniques could put them at an advantage for DOFMS. To date, three types of position-sensitive detectors have been used for DOFMS: a microchannel plate with a phosphorescent screen, a focal plane camera, and an IonCCD array; advances in detector technology will likely improve DOFMS figures-of-merit. In addition, the combination of CMA with TOF detection has provided improved resolution and duty factor over a narrow m/z range (compared with conventional, single-pass TOFMS). The unique characteristics of DOFMS can enable the intact collection of large biomolecules, clusters, and organisms. DOFMS might also play a key role in achieving the long-sought goal of simultaneous MS/MS. Graphical Abstract ᅟ.

9.
J Am Soc Mass Spectrom ; 27(3): 371-9, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26552388

ABSTRACT

Distance-of-flight mass spectrometry (DOFMS) is demonstrated for the first time with a commercially available ion detector-the IonCCD camera. Because DOFMS is a velocity-based MS technique that provides spatially dispersive, simultaneous mass spectrometry, a position-sensitive ion detector is needed for mass-spectral collection. The IonCCD camera is a 5.1-cm long, 1-D array that is capable of simultaneous, multichannel ion detection along a focal plane, which makes it an attractive option for DOFMS. In the current study, the IonCCD camera is evaluated for DOFMS with an inductively coupled plasma (ICP) ionization source over a relatively short field-free mass-separation distance of 25.3-30.4 cm. The combination of ICP-DOFMS and the IonCCD detector results in a mass-spectral resolving power (FWHM) of approximately 900 and isotope-ratio precision equivalent to or slightly better than current ICP-TOFMS systems. The measured isotope-ratio precision in % relative standard deviation (%RSD) was ≥0.008%RSD for nonconsecutive isotopes at 10-ppm concentration (near the ion-signal saturation point) and ≥0.02%RSD for all isotopes at 1-ppm. Results of DOFMS with the IonCCD camera are also compared with those of two previously characterized detection setups.

10.
J Am Soc Mass Spectrom ; 27(3): 380-7, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26634932

ABSTRACT

A zoom-time-of-flight mass spectrometer has been coupled to an inductively coupled plasma (ICP) ionization source. Zoom-time-of-flight mass spectrometry (zoom-TOFMS) combines two complementary types of velocity-based mass separation. Specifically, zoom-TOFMS alternates between conventional, constant-energy acceleration (CEA) TOFMS and energy-focused, constant-momentum acceleration (CMA) (zoom) TOFMS. The CMA mode provides a mass-resolution enhancement of 1.5-1.7× over CEA-TOFMS in the current, 35-cm ICP-zoom-TOFMS instrument geometry. The maximum resolving power (full-width at half-maximum) for the ICP-zoom-TOFMS instrument is 1200 for CEA-TOFMS and 1900 for CMA-TOFMS. The CMA mode yields detection limits of between 0.02 and 0.8 ppt, depending upon the repetition rate and integration time-compared with single ppt detection limits for CEA-TOFMS. Isotope-ratio precision is shot-noise limited at approximately 0.2% relative-standard deviation (RSD) for both CEA- and CMA-TOFMS at a 10 kHz repetition rate and an integration time of 3-5 min. When the repetition rate is increased to 43.5 kHz for CMA, the shot-noise limited, zoom-mode isotope-ratio precision is improved to 0.09% RSD for the same integration time.


Subject(s)
Mass Spectrometry/instrumentation , Elements , Equipment Design , Isotopes/analysis , Mass Spectrometry/methods
11.
Chem Sci ; 6(6): 3334-3341, 2015 Jun 01.
Article in English | MEDLINE | ID: mdl-28706697

ABSTRACT

Nanopipettes (pipettes with diameters <1 µm) were explored as pressure-driven fluid manipulation tools for sampling nanoliter volumes of fluids. The fundamental behavior of fluids confined in the narrow channels of the nanopipette shank was studied to optimize sampling volume and probe geometry. This method was utilized to collect nanoliter volumes (<10 nL) of sample from single Allium cepa cells and live Drosophila melanogaster first instar larvae. Matrix assisted laser desorption/ionization-mass spectrometry (MALDI-MS) was utilized to characterize the collected sample. The use of nanopipettes for surface sampling of mouse brain tissue sections was also explored. Lipid analyses were performed on mouse brain tissues with spatial resolution of sampling as small as 50 µm. Nanopipettes were shown to be a versatile tool that will find further application in studies of sample heterogeneity and population analysis for a wide range of samples.

12.
Anal Bioanal Chem ; 406(29): 7511-21, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25178932

ABSTRACT

Ambient desorption/ionization (ADI) sources coupled to mass spectrometry (MS) offer outstanding analytical features: direct analysis of real samples without sample pretreatment, combined with the selectivity and sensitivity of MS. Since ADI sources typically work in the open atmosphere, ambient conditions can affect the desorption and ionization processes. Here, the effects of internal source parameters and ambient humidity on the ionization processes of the flowing atmospheric pressure afterglow (FAPA) source are investigated. The interaction of reagent ions with a range of analytes is studied in terms of sensitivity and based upon the processes that occur in the ionization reactions. The results show that internal parameters which lead to higher gas temperatures afforded higher sensitivities, although fragmentation is also affected. In the case of humidity, only extremely dry conditions led to higher sensitivities, while fragmentation remained unaffected.

13.
Anal Bioanal Chem ; 406(29): 7417-8, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25134674
14.
Analyst ; 139(18): 4505-11, 2014 Sep 21.
Article in English | MEDLINE | ID: mdl-25054911

ABSTRACT

In the last several years, illicit electronic components have been discovered in the inventories of several distributors and even installed in commercial and military products. Illicit or counterfeit electronic components include a broad category of devices that can range from the correct unit with a more recent date code to lower-specification or non-working systems with altered names, manufacturers and date codes. Current methodologies for identification of counterfeit electronics rely on visual microscopy by expert users and, while effective, are very time-consuming. Here, a plasma-based ambient desorption/ionization source, the flowing atmospheric pressure afterglow (FAPA) is used to generate a mass-spectral fingerprint from the surface of a variety of discrete electronic integrated circuits (ICs). Chemometric methods, specifically principal component analysis (PCA) and the bootstrapped error-adjusted single-sample technique (BEAST), are used successfully to differentiate between genuine and counterfeit ICs. In addition, chemical and physical surface-removal techniques are explored and suggest which surface-altering techniques were utilized by counterfeiters.

15.
Anal Bioanal Chem ; 406(29): 7419-30, 2014 Nov.
Article in English | MEDLINE | ID: mdl-24866712

ABSTRACT

In this study, we demonstrate the performance of a new mass spectrometry concept called zoom time-of-flight mass spectrometry (zoom-TOFMS). In our zoom-TOFMS instrument, we combine two complementary types of TOFMS: conventional, constant-energy acceleration (CEA) TOFMS and constant-momentum acceleration (CMA) TOFMS to provide complete mass-spectral coverage as well as enhanced resolution and duty factor for a narrow, targeted mass region, respectively. Alternation between CEA- and CMA-TOFMS requires only that electrostatic instrument settings (i.e., reflectron and ion optics) and ion acceleration conditions be changed. The prototype zoom-TOFMS instrument has orthogonal-acceleration geometry, a total field-free distance of 43 cm, and a direct-current glow-discharge ionization source. Experimental results demonstrate that the CMA-TOFMS "zoom" mode offers resolution enhancement of 1.6 times over single-stage acceleration CEA-TOFMS. For the atomic mass range studied here, the maximum resolving power at full-width half-maximum observed for CEA-TOFMS was 1,610 and for CMA-TOFMS the maximum was 2,550. No difference in signal-to-noise (S/N) ratio was observed between the operating modes of zoom-TOFMS when both were operated at equivalent repetition rates. For a 10-kHz repetition rate, S/N values for CEA-TOFMS varied from 45 to 990 and from 67 to 10,000 for CMA-TOFMS. This resolution improvement is the result of a linear TOF-to-mass scale and the energy-focusing capability of CMA-TOFMS. Use of CMA also allows ions outside a given m/z range to be rejected by simple ion-energy barriers to provide a substantial improvement in duty factor.

16.
J Am Soc Mass Spectrom ; 25(5): 800-8, 2014 May.
Article in English | MEDLINE | ID: mdl-24658804

ABSTRACT

Ambient desorption/ionization mass spectrometry (ADI-MS) has developed into an important analytical field over the last 9 years. The ability to analyze samples under ambient conditions while retaining the sensitivity and specificity of mass spectrometry has led to numerous applications and a corresponding jump in the popularity of this field. Despite the great potential of ADI-MS, problems remain in the areas of ion identification and quantification. Difficulties with ion identification can be solved through modified instrumentation, including accurate-mass or MS/MS capabilities for analyte identification. More difficult problems include quantification because of the ambient nature of the sampling process. To characterize and improve sample volatilization, ionization, and introduction into the mass spectrometer interface, a method of visualizing mass transport into the mass spectrometer is needed. Schlieren imaging is a well-established technique that renders small changes in refractive index visible. Here, schlieren imaging was used to visualize helium flow from a plasma-based ADI-MS source into a mass spectrometer while ion signals were recorded. Optimal sample positions for melting-point capillary and transmission-mode (stainless steel mesh) introduction were found to be near (within 1 mm of) the mass spectrometer inlet. Additionally, the orientation of the sampled surface plays a significant role. More efficient mass transport resulted for analyte deposits directly facing the MS inlet. Different surfaces (glass slide and rough surface) were also examined; for both it was found that the optimal position is immediately beneath the MS inlet.


Subject(s)
Air/analysis , Caffeine/analysis , Environmental Monitoring/methods , Models, Chemical , Salicylates/analysis , Atmospheric Pressure , Caffeine/chemistry , Environmental Monitoring/instrumentation , Helium/chemistry , Mass Spectrometry/instrumentation , Reproducibility of Results , Salicylates/chemistry , Surface Properties , Volatilization
17.
J Am Soc Mass Spectrom ; 24(12): 1853-61, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24081835

ABSTRACT

Fundamental aspects of constant-momentum acceleration time-of-flight mass spectrometry (CMA-TOFMS) are explored as a means to improve mass resolution. By accelerating all ions to the same momentum rather than to the same energy, the effects of the initial ion spatial and energy distributions upon the total ion flight time are decoupled. This decoupling permits the initial spatial distribution of ions in the acceleration region to be optimized independently, and energy focus, including ion turn-around-time error, to be accomplished with a linear-field reflectron. Constant-momentum acceleration also linearly disperses ions across time according to mass-to-charge (m/z) ratio, instead of the quadratic relationship between flight time and m/z found in conventional TOFMS. Here, CMA-TOFMS is shown to achieve simultaneous spatial and energy focusing over a selected portion of the mass spectrum. An orthogonal-acceleration time-of-flight system outfitted with a reduced-pressure DC glow discharge (GD) ionization source is used to demonstrate CMA-TOFMS with atomic ions. The influence of experimental parameters such as the amplitude and width of the time-dependent CMA pulse on mass resolution is investigated, and a useful CMA-TOFMS focusing window of 2 to 18 Da is found for GD-CMA-TOFMS.


Subject(s)
Mass Spectrometry/instrumentation , Algorithms , Equipment Design , Ions/analysis , Isotopes/analysis
18.
Anal Chem ; 85(18): 8498-502, 2013 Sep 17.
Article in English | MEDLINE | ID: mdl-23968307

ABSTRACT

Work presented here demonstrates application of nanopipettes pulled to orifice diameters of less than 100 nm as electrospray ionization emitters for mass spectrometry. Mass spectrometric analysis of a series of peptides and proteins electrosprayed from pulled-quartz capillary nanopipette emitters with internal diameters ranging from 37 to 70 nm is detailed. Overall, the use of nanopipette emitters causes a shift toward the production of ions of higher charge states and leads to a reduction in width of charge-state distribution as compared to typical nanospray conditions. Further, nanopipettes show improved S/N and the same signal precision as typical nanospray, despite the much smaller dimensions. As characterized by SEM images acquired before and after spray, nanopipettes are shown to be robust under conditions employed. Analytical calculations and numerical simulations are used to calculate the electric field at the emitter tip, which can be significant for the small diameter tips used.

19.
J Am Soc Mass Spectrom ; 24(11): 1736-44, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23982936

ABSTRACT

Distance-of-flight mass spectrometry (DOFMS) is a velocity-based, spatially dispersive MS technique in which ions are detected simultaneously along the plane of a spatially selective detector. In DOFMS, ions fly though the instrument and mass separate over a set period of time. The single flight time at which all ions are measured defines the specific m/z values that are detectable; the range of m/z values is dictated by the length of the spatially selective detector. However, because each packet of ions is detected at a single flight time, multiple groups of ions can fly through the instrument concurrently and be detected at a single detector. In this way, DOFMS experiments can be interleaved to perform several mass separation experiments within a single DOF repetition period. Interleaved operation allows the orthogonal acceleration region to be operated at a repetition rate higher than the reciprocal of the flight time, which improves the duty factor of the technique. In this paper, we consider the fundamental parameters of interleaved DOFMS and report first results.


Subject(s)
Mass Spectrometry/methods , Ions , Mass Spectrometry/instrumentation , Molecular Weight
20.
Anal Chem ; 85(15): 7512-8, 2013 Aug 06.
Article in English | MEDLINE | ID: mdl-23808829

ABSTRACT

The flowing atmospheric-pressure afterglow (FAPA) is a promising new source for atmospheric-pressure, ambient desorption/ionization mass spectrometry. However, problems exist with reproducible sample introduction into the FAPA source. To overcome this limitation, a new FAPA geometry has been developed in which concentric tubular electrodes are utilized to form a halo-shaped discharge; this geometry has been termed the halo-FAPA or h-FAPA. With this new geometry, it is still possible to achieve direct desorption and ionization from a surface; however, sample introduction through the inner capillary is also possible and improves interaction between the sample material (solution, vapor, or aerosol) and the plasma to promote desorption and ionization. The h-FAPA operates with a helium gas flow of 0.60 L/min outer, 0.30 L/min inner, and applied current of 30 mA at 200 V for 6 W of power. In addition, separation of the discharge proper and sample material prevents perturbations to the plasma. Optical-emission characterization and gas rotational temperatures reveal that the temperature of the discharge is not significantly affected (<3% change at 450 K) by water vapor during solution-aerosol sample introduction. The primary mass-spectral background species are protonated water clusters, and the primary analyte ions are protonated molecular ions (M + H(+)). Flexibility of the new ambient sampling source is demonstrated by coupling it with a laser ablation unit, a concentric nebulizer, and a droplet-on-demand system for sample introduction. A novel arrangement is also presented in which the central channel of the h-FAPA is used as the inlet to a mass spectrometer.


Subject(s)
Atmospheric Pressure , Mass Spectrometry/instrumentation , Electric Conductivity , Equipment Design , Pharmaceutical Preparations/chemistry
SELECTION OF CITATIONS