Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 413
Filter
1.
Can J Cardiol ; 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38851390

ABSTRACT

BACKGROUND: Treatment approach of coronary artery fistulas (CAFs) is debatable and long-term outcomes are unknown. METHODS: Retrospective institutional data review of children in whom echocardiographically suspected CAFs were confirmed during cardiac catheterization from 1997-to-2023. Treatment approach and outcomes were assessed. RESULTS: We identified 94 CAFs in 78 patients (42.3% males), median age of 3.4 years (IQR, 0.9-6.6). 25 (32%) patients had other congenital anomalies. 41/52 (78.8%) patients with isolated CAFs were asymptomatic. Most common site of CAF origin and drainage was the left system (62.8%) and right cardiac cavities (80.8%). Overall median follow-up was 101 months (IQR, 41-185). 23 (29.5%) patients with 35 (37.2%) small or non-shunting CAFs had conservative management and 20/23 (87%) patients had an uneventful follow-up. 8 (10.2%) patients with 9 (9.6%) complex CAFs were directly sent for surgery. One had early surgical patch failure needing surgical reintervention. 47 (60.3%) patients had catheter closure of 50 (53.2%) medium or large-sized CAFs using coils (30%), vascular plugs (20%), Nitinol duct occluders (40%), or material combination (10%). Six serious complications occurred. 2/3 patients with unsuccessful catheter procedures had subsequent surgeries. 2/3 patients with mild shunts had successful redo closures. One asymptomatic patient had recanalization after 12 years and is under watchful observation. CONCLUSIONS: CAFs have various anatomies and clinical presentations. Transcatheter closure is effective in carefully selected patients but is not complication-free. Surgery is a valuable upfront option in complex CAFs or bailout of unsuccessful transcatheter closures even though not frequently used.

2.
Eur J Cardiothorac Surg ; 65(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38366617

ABSTRACT

We report on a 6-year-old girl (18 kg/120 cm) who was diagnosed on day 6 postoperative with an occlusive thrombosis of a right ventricle-to-pulmonary artery conduit in the setting of a Ross procedure that was performed for severe native aortic valve insufficiency secondary to late diagnosis of bacterial endocarditis. We applied the Indigo® aspiration system from Penumbra® (Alameda, USA) to mechanically dissolve and remove the thrombus, restore flow, gradually wean from extracorporeal support, and replace the conduit after 4 days. The patient experiences good surgical outcomes at 3 months of follow-up.


Subject(s)
Aortic Valve Insufficiency , Pulmonary Artery , Child , Female , Humans , Pulmonary Artery/diagnostic imaging , Pulmonary Artery/surgery , Treatment Outcome , Heart Ventricles/diagnostic imaging , Heart Ventricles/surgery , Aortic Valve Insufficiency/surgery , Catheters
3.
Front Cardiovasc Med ; 11: 1332152, 2024.
Article in English | MEDLINE | ID: mdl-38357517

ABSTRACT

Background: Axillary arterial access (AAA) in pediatric heart catheterizations is undervalued. Methods: We retrospectively reviewed children with congenital heart diseases (CHDs) who received trans-axillary arterial catheterizations between January 2019 and February 2023. We aimed ultrasound-guided punctures in the proximal two-thirds of axillary arteries with diameters ≥2 mm to insert 7 cm/4 Fr short introducers. We administrated intra-arterial verapamil (1.25 mg) and heparin (100 UI/kg). We infiltrated per-operatively 2% lignocaine (10 mg) for arterial spasms, long sheaths use (≥5 Fr), and ≥60 min procedures in <3 kg patients. Results: We identified 30 patients (66.7% males) with a median age of 1.1 months (IQR, 0.3-5.4), and a median weight of 3.1 kg (IQR, 2.7-3.7). 5/30 patients had six redo interventions after a median of 3.9 months (IQR, 1.7-5.1). Overall, 27/36 procedures were interventional, including 6 aortic valvuloplasties, 6 balloon angioplasties, and 15 stenting procedures. The median arterial axillary angiographic diameter was 2.6 mm (IQR, 2.4-3). Access was right-sided in 23/36 (63.9%) procedures and obtained using 21G/2.5 cm bevel needles in 25/36 (69.4%) procedures. No hemodynamical change occurred after introducing spasmolytic drugs. The median fluoroscopy time was 26.1 min (IQR, 19.2-34.8). There were two self-resolving arterial dissections, one sub-occlusive arterial thrombosis (resolved with 6 weeks of enoxaparin), and one occlusive arterial thrombosis (resolved with alteplase thrombolysis and 6 weeks of enoxaparin). Median follow-up was 11.7 months (IQR, 8-17.5). Four patients with complex univentricular hearts died from non-procedural causes at a median of 40 days (IQR, 31-161) postoperative. Conclusion: Systematic approach for AAA is the key to success and unlocks the many potentials of trans-axillary pediatric cardiology interventions.

4.
Cardiol Young ; 34(2): 455-458, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38167420

ABSTRACT

We report on a 6-month-old infant (6 Kg/ 64 cm) with perimembranous ventricular septal defect (absent sub-aortic rim, 10 mm left ventricular entry, and 4 and 6 mm right ventricular exists) and successful retrograde closure using an 8x6 mm KONAR-MF™ VSD occluder (Lifetech, China). Immediate and 48 hours post-procedure ultrasounds showed an accurately positioned device and two jets of mild-to-moderate residual shunts. At the 2-week follow-up, the device did not change position and the shunt was stable and intra-prosthetic. The scheduled 3-month follow-up was skipped for familial reasons. The patient came back without alarming symptoms for the regular 6-month follow-up, and the device was found embolised to the left pulmonary artery. The device was retrieved surgically, and the defect was patch-closed with excellent outcomes. There was a pseudoaneurysm involving the tricuspid valve chordae and the device was endothelialized partially on one edge suggesting that embolization occurred somewhere between 3 months and 6 months post-operative. Defects with compromised anatomies should be closed surgically to avoid suboptimal results, especially in small infants.


Subject(s)
Embolization, Therapeutic , Heart Septal Defects, Ventricular , Septal Occluder Device , Infant , Humans , Cardiac Catheterization/methods , Echocardiography , Embolization, Therapeutic/adverse effects , Tricuspid Valve , Heart Septal Defects, Ventricular/diagnosis , Septal Occluder Device/adverse effects , Treatment Outcome
5.
Can J Cardiol ; 40(1): 77-86, 2024 01.
Article in English | MEDLINE | ID: mdl-37726075

ABSTRACT

BACKGROUND: There is no stent designed or approved for use in infants. We sought to obtain in vitro and in vivo data on a new concept conceived to implant Optimus-L stents at infant vessel diameters and offer a potential long term stent solution. METHODS: Nineteen Optimus-L stents were mounted on 8 types of angioplasty balloons with diameters 6, 8, and 10 mm with the use of an injection-moulded hand crimper. We evaluated balloon-stent unit (BSU) stability before insertion and advancement through short Terumo introducers with incremental French size and possibility of side-arm contrast injections. Three types of long sheaths were tested. Stents were inflated to balloon nominal diameters and re-expanded to 18 and 23 mm. Stent recoil, foreshortening, and fracture were evaluated. In vivo implantations were performed afterward. RESULTS: In vitro: Medtronic Evercross balloons and modified Terumo Destination sheaths were the best combination: BSUs were inserted in 6 F sheaths with possible injections (for 6 and 8 mm balloons), and 7 F sheaths without injections (for the 10 mm balloon). Retrieving BSUs inside the sheath required 1 additional F-size. Boston Scientific Sterling and Balton Lovix balloons, as well as APT Braidin L guiding sheaths showed unsatisfactory performance. Dilation up to 23 mm was possible, and stent shortening was < 24% at 18 mm and < 37% at 23 mm. Recoil was limited, and no stent fractured. In vivo: Optimus-L stents were used to treat 2 infants with aortic coarctation and 2 children with pulmonary artery stenosis with the use of 8 mm balloons and low-profile access. CONCLUSIONS: Optimus-L stents can be implanted safely in small patients with a low-profile approach. These stents have the potential to achieve adult size while maintaining structural integrity.


Subject(s)
Angioplasty, Balloon , Aortic Coarctation , Child , Infant , Adult , Humans , Stents , Dilatation , Pulmonary Artery/surgery , Treatment Outcome
6.
Cardiol Young ; 34(1): 209-211, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38031499

ABSTRACT

We report a 20-year-old female patient (76 Kg/164 cm) with an extra-cardiac Fontan circulation who was referred to our institution for exertional dyspnoea and desaturation. The patient was diagnosed with a large calcified thrombus at the level of the Fontan fenestration, protruding inside the lumen of the conduit and reducing the diameter by half with a 3 mmHg pressure gradient. Transcatheter stent expansion of the obstructed extra-cardiac conduit was done with a 48 mm long XXL PTFE-covered Optimus-CVS® under temporary cerebral embolic protection with a TriGUARD-3™ deflection filter device (Keystone Heart). There was no procedural complication and the 3 months clinical outcomes are good.


Subject(s)
Embolic Protection Devices , Fontan Procedure , Female , Humans , Young Adult , Adult , Cardiac Catheterization , Stents/adverse effects , Fontan Procedure/adverse effects , Treatment Outcome
7.
J Mol Cell Cardiol ; 186: 16-30, 2024 01.
Article in English | MEDLINE | ID: mdl-37935281

ABSTRACT

Epicardial-derived cells (EPDCs) are involved in the regulation of myocardial growth and coronary vascularization and are critically important for proper development of the atrioventricular (AV) valves. SOX9 is a transcription factor expressed in a variety of epithelial and mesenchymal cells in the developing heart, including EPDCs. To determine the role of SOX9 in epicardial development, an epicardial-specific Sox9 knockout mouse model was generated. Deleting Sox9 from the epicardial cell lineage impairs the ability of EPDCs to invade both the ventricular myocardium and the developing AV valves. After birth, the mitral valves of these mice become myxomatous with associated abnormalities in extracellular matrix organization. This phenotype is reminiscent of that seen in humans with myxomatous mitral valve disease (MVD). An RNA-seq analysis was conducted in an effort to identify genes associated with this myxomatous degeneration. From this experiment, Cd109 was identified as a gene associated with myxomatous valve pathogenesis in this model. Cd109 has never been described in the context of heart development or valve disease. This study highlights the importance of SOX9 in the regulation of epicardial cell invasion-emphasizing the importance of EPDCs in regulating AV valve development and homeostasis-and reports a novel expression profile of Cd109, a gene with previously unknown relevance in heart development.


Subject(s)
Heart Valve Diseases , Mitral Valve , Humans , Mice , Animals , Mitral Valve/metabolism , Heart Valve Diseases/pathology , Heart Ventricles/metabolism , Myocardium/metabolism , Mice, Knockout , Transcription Factors/metabolism
8.
Front Cardiovasc Med ; 10: 1322787, 2023.
Article in English | MEDLINE | ID: mdl-38111890

ABSTRACT

Background: SwiftNINJA (Merit Medical Systems, USA) is a novel steerable microcatheter intended for coronary and peripheral vascular interventions. We evaluate and report the first use of SwiftNINJA in pediatric catheterization of congenital heart defects (CHDs). Methods: We performed a retrospective clinical data review of children with CHDs in whom SwiftNINJA was used during cardiac catheterization between April 2022 and June 2023. Utility, application, and standard safety were described comprehensively. Results: We identified 19 patients (78.9% males) with a median age of 5.3 months (IQR, 2-13.9), and a median weight of 5.3 kg (IQR, 4-7.7). 36.8% of the catheterizations were transarterial and 78.9% were interventional. SwiftNINJA was applied upfront in 3/19 patients to cannulate precisely the right pulmonary artery and eliminate the risk of dislocating a freshly implanted left pulmonary flow restrictor. In 16/19 patients, SwiftNINJA was applied after a median of 5 (IQR, 5-7) failed catheterization attempts using various combinations of catheters, microcatheters, and wires to cannulate challenging vasculature in seven, engage the lumen of stented vessels in five, cross complex aortic valve stenosis in three, and cross an apical ventricular septal defect in one patient with Damus-Kaye-Stansel repair. After the SwiftNINJA application, catheterization was done from the first attempt in 12/16 patients and from the second attempt in 4/16 patients. The median applied tip angulation was 90 degrees (IQR, 85-95). All procedures were completed successfully. No device malfunction or adverse events occurred. Conclusions: SwiftNINJA is a valuable addition for selective catheterization of challenging vasculatures or valvular anatomies in children with CHDs.

9.
Cardiol Young ; 33(12): 2654-2656, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37622316

ABSTRACT

Atrioseptostomy balloon catheter is an essential item to have on our shelves. However, the recall and shortage in production of the commonly used balloon atrioseptostomy catheters posed an imminent threat to our patients. Herein, we present the case of a newborn with a post-natal diagnosis of simple transposition of great arteries and restrictive atrial communication where repeated static balloon atrial septostomy using a 9 mm x 20 mm Sterling balloon failed to improve his status. We had to improvise per-operatively a new bespoke technique to perform a vital pull-through balloon atrial septostomy. The distal third of a 10 mm x 20 mm semi-compliant Cristal balloon was exteriorised out the tip of a 6-Fr 55 cm Cook Flexor sheath in the left atrium, and both were simultaneously pulled back to the right atrium to create an 8 mm septal defect. The procedure was successful without any complications. The baby was weaned off prostaglandin on day 3 and surgically repaired on day 5 with excellent results.


Subject(s)
Cardiac Surgical Procedures , Heart Septal Defects, Atrial , Transposition of Great Vessels , Infant , Infant, Newborn , Humans , Heart Septal Defects, Atrial/surgery , Heart Atria/surgery , Pericardiectomy , Catheters
10.
Infect Dis Poverty ; 12(1): 81, 2023 Aug 29.
Article in English | MEDLINE | ID: mdl-37641108

ABSTRACT

BACKGROUND: The increasing reports of resistance to pyrethroid insecticides associated with reduced efficacy of pyrethroid-only interventions highlight the urgency of introducing new non-pyrethroid-only control tools. Here, we investigated the performance of piperonyl-butoxide (PBO)-pyrethroid [Permanet 3.0 (P3.0)] and dual active ingredients (AI) nets [Interceptor G2 (IG2): containing pyrethroids and chlorfenapyr and Royal Guard (RG): containing pyrethroids and pyriproxyfen] compared to pyrethroid-only net Royal Sentry (RS) against pyrethroid-resistant malaria vectors in Cameroon. METHODS: The efficacy of these tools was firstly evaluated on Anopheles gambiae s.l. and Anopheles funestus s.l. from Gounougou, Mibellon, Mangoum, Nkolondom, and Elende using cone/tunnel assays. In addition, experimental hut trials (EHT) were performed to evaluate the performance of unwashed and 20 times washed nets in semi-field conditions. Furthermore, pyrethroid-resistant markers were genotyped in dead vs alive, blood-fed vs unfed mosquitoes after exposure to the nets to evaluate the impact of these markers on net performance. The XLSTAT software was used to calculate the various entomological outcomes and the Chi-square test was used to compare the efficacy of various nets. The odds ratio and Fisher exact test were then used to establish the statistical significance of any association between insecticide resistance markers and bed net efficacy. RESULTS: Interceptor G2 was the most effective net against wild pyrethroid-resistant An. funestus followed by Permanet 3.0. In EHT, this net induced up to 87.8% mortality [95% confidence interval (CI): 83.5-92.1%) and 55.6% (95% CI: 48.5-62.7%) after 20 washes whilst unwashed pyrethroid-only net (Royal Sentry) killed just 18.2% (95% CI: 13.4-22.9%) of host-seeking An. funestus. The unwashed Permanet 3.0 killed up to 53.8% (95% CI: 44.3-63.4%) of field-resistant mosquitoes and 47.2% (95% CI: 37.7-56.7%) when washed 20 times, and the Royal Guard 13.2% (95% CI: 9.0-17.3%) for unwashed net and 8.5% (95% CI: 5.7-11.4%) for the 20 washed net. Interceptor G2, Permanet 3.0, and Royal Guard provided better personal protection (blood-feeding inhibition 66.2%, 77.8%, and 92.8%, respectively) compared to pyrethroid-only net Royal Sentry (8.4%). Interestingly, a negative association was found between kdrw and the chlorfenapyr-based net Interceptor G2 (χ2 = 138; P < 0.0001) with homozygote-resistant mosquitoes predominantly found in the dead ones. CONCLUSIONS: The high mortality recorded with Interceptor G2 against pyrethroid-resistant malaria vectors in this study provides first semi-field evidence of high efficacy against these major malaria vectors in Cameroon encouraging the implementation of this novel net for malaria control in the country. However, the performance of this net should be established in other locations and on other major malaria vectors before implementation at a large scale.


Subject(s)
Anopheles , Malaria , Animals , Cameroon , Malaria/prevention & control , Mosquito Vectors
11.
Cancer Res Commun ; 3(8): 1486-1500, 2023 08.
Article in English | MEDLINE | ID: mdl-37559947

ABSTRACT

While the role of prostaglandin E2 (PGE2) in promoting malignant progression is well established, how to optimally block the activity of PGE2 signaling remains to be demonstrated. Clinical trials with prostaglandin pathway targeted agents have shown activity but without sufficient significance or dose-limiting toxicities that have prevented approval. PGE2 signals through four receptors (EP1-4) to modulate tumor progression. EP2 and EP4 signaling exacerbates tumor pathology and is immunosuppressive through potentiating cAMP production. EP1 and EP3 signaling has the opposite effect through increasing IP3 and decreasing cAMP. Using available small-molecule antagonists of single EP receptors, the cyclooxygenase-2 (COX-2) inhibitor celecoxib, or a novel dual EP2/EP4 antagonist generated in this investigation, we tested which approach to block PGE2 signaling optimally restored immunologic activity in mouse and human immune cells and antitumor activity in syngeneic, spontaneous, and xenograft tumor models. We found that dual antagonism of EP2 and EP4 together significantly enhanced the activation of PGE2-suppressed mouse and human monocytes and CD8+ T cells in vitro as compared with single EP antagonists. CD8+ T-cell activation was dampened by single EP1 and EP3 antagonists. Dual EP2/EP4 PGE2 receptor antagonists increased tumor microenvironment lymphocyte infiltration and significantly reduced disease burden in multiple tumor models, including in the adenomatous polyposis coli (APC)min+/- spontaneous colorectal tumor model, compared with celecoxib. These results support a hypothesis that redundancy of EP2 and EP4 receptor signaling necessitates a therapeutic strategy of dual blockade of EP2 and EP4. Here we describe TPST-1495, a first-in-class orally available small-molecule dual EP2/EP4 antagonist. Significance: Prostaglandin (PGE2) drives tumor progression but the pathway has not been effectively drugged. We demonstrate significantly enhanced immunologic potency and antitumor activity through blockade of EP2 and EP4 PGE2 receptor signaling together with a single molecule.


Subject(s)
Neoplasms , Prostaglandins , Humans , Animals , Mice , Dinoprostone/metabolism , Receptors, Prostaglandin E, EP2 Subtype/metabolism , Celecoxib/pharmacology , CD8-Positive T-Lymphocytes/metabolism , Receptors, Prostaglandin E, EP4 Subtype/metabolism , Cyclooxygenase 2 Inhibitors , Tumor Microenvironment
12.
Front Cardiovasc Med ; 10: 1215397, 2023.
Article in English | MEDLINE | ID: mdl-37476569

ABSTRACT

Background: Retrograde closure of perimembranous ventricular septal defects (pmVSDs) is a well-established procedure. However, interventionists are still looking for the best closure device. Methods: We performed a single-center retrospective review of 5-year-experience (from July 2015 to July 2020) with retrograde closure of pmVSDs using AmplatzerTM Duct Occluder II (ADOII) and KONAR-MF™ VSD occluder (MFO). Deficient sub-aortic rim (SAR) (≤2.5 mm for MFO and ≤3 mm for ADOII) was an exclusion criterion in defects with a diameter ratio (right-side exit/left-side entry) > 0.5. Results: We identified 77 patients (57.1% males) with a median age of 4.3 years (IQR, 2.2-8.3) and a median weight of 16 kg (IQR, 11.2-24.5). 44 (57.1%) defects (22.7% with deficient SARs) with a median left-side defect diameter of 8.7 mm (IQR, 5.7-10) were closed with ADOIIs. 33 (42.9%) defects (51.5% with deficient SARs) with a median left-side defect diameter of 10.8 mm (IQR, 8.8-13.5) were closed with MFOs. One 7/5 MFO was removed before release and upsized to a 12/10 MFO. Implantation success rate was 100% with ADOII and 90.9% with MFO devices. Two MFOs were snare-recaptured after embolization, and one 9/7 MFO was snare-retrieved for a new onset of grade-2 aortic regurgitation that persisted afterward. Median follow-up was 3.3 years (IQR, 2.1-4.2) for ADOII and 2.3 years (IQR, 1.7-2.5) for MFO. No permanent heart block or death occurred. Freedom from left ventricular dilation was 94.62% at 36 months of follow-up. Freedom from residual shunt was 90.62% for MFO and 89.61% for ADOII at 24 months of follow-up. One 2.6-year-old patient with baseline mild aortic valve prolapse and trivial aortic regurgitation developed a grade-2 aortic regurgitation after 9/7 MFO implantation. He was treated surgically after two years without device extraction. One new grade-2 asymptomatic tricuspid regurgitation persisted at the last follow-up in the ADOII group. Conclusions: ADOII and MFO are complementary devices for effective retrograde closure of pmVSDs in children, including defects with absent or deficient SAR. ADOII is limited to smaller defects but offers a lower profile and a flexible left-side disk for better maneuverability over the aortic valve during retrograde implantation.

13.
Children (Basel) ; 10(7)2023 Jul 10.
Article in English | MEDLINE | ID: mdl-37508694

ABSTRACT

BACKGROUND: A pulmonary sequestration (PS) is an area of bronchopulmonary tissue with aberrant arterial supply. Transcatheter occlusion of PSs is an appealing treatment option, but data on outcomes remain scarce. We aim to describe our experience with transcatheter management of PS in infants and children. METHODS: Retrospective review of clinical data of all patients with suspected PS sent for diagnostic and/or interventional cardiac catheterization at our institution between January 1999 and May 2021. Procedural considerations, techniques, standard safety, and outcomes were assessed. RESULTS: We identified 71 patients (52.1% males), with median age and weight of 4.9 months (IQR, 2.1-26.6) and 4.2 kg (IQR, 3.9-12.1), respectively. Sixty-one (86%) patients had associated congenital heart defects (CHDs). Forty-two (59%) patients had pulmonary arterial hypertension (PAH) at the time of diagnosis. Fifty-three (74.7%) patients underwent embolization of the PS feeding vessel using microcoils and/or vascular plugs, and eight (15.1%) of these were neonates who presented with severe PAH and cardiac failure. Two patients had large feeding vessels and were treated surgically. Sixteen (22.5%) patients with small feeding vessels received conservative management. At median follow-up of 36.4 months (IQR, 2.1-89.9), seven patients had died, 24 patients had CHD corrective surgeries, 26 patients had redo catheterizations, and five patients had persistent PAH. No PS surgical resection was needed, and no infection of the remaining lung tissue occurred. CONCLUSIONS: Transcatheter assessment and treatment of PSs is a safe and effective procedure. Neonates with large PSs are severely symptomatic and improve remarkably after PS closure. PS embolization and surgical repair of associated CHDs generally leads to the normalization of pulmonary pressures.

14.
Malar J ; 22(1): 205, 2023 Jul 05.
Article in English | MEDLINE | ID: mdl-37407962

ABSTRACT

BACKGROUND: Malaria is the main cause of morbidity and mortality in Cameroon. Insecticide-treated nets (ITNs) significantly reduce malaria transmission, but their use is not common in the population. This study aimed to estimate the nationwide prevalence of the non-use of ITNs and identify its major determinants. METHODS: A cross-sectional study was conducted on interview data collected in households selected across all the regions of Cameroon through a non-probabilistic, random, 2-stage stratified sampling process. Descriptive statistics were used to describe the distribution of baseline characteristics across the households, and statistical tests assessed if the distribution of these characteristics differed significantly based on the non-use of ITNs, with 0.05 serving as a threshold of the p-value for statistical significance. The prevalence of the non-use of ITNs was estimated, and logistic regression models were used to tally the odds ratios of the associations between various factors and the non-use of ITNs, along with their 95% confidence intervals. The sensitivity, specificity, and area under the receiver operating characteristic (ROC) curve (AUC) were determined, and the Hosmer Lemeshow test was used to measure the goodness of fit of each statistical model. RESULTS: Of the 7593 households interviewed, 77% had at least one ITN and 59% of the population used ITNs. Only 72% of the population with at least one ITN used it. The logistic model of the multivariate analysis was significant at a 5% threshold. The AUC was 0.7087 and the error rate was 18.01%. The sensitivity and specificity of the model were 97.56% and 13.70%, respectively. The factors that were associated with ITN use were the presence of sufficient nets in the household (p < 0.0001), the region of residence (p < 0.0001), the level of education of the respondent (p < 0.0001), and the standard of living (p = 0.0286). Sex, age, colour preferences, as well as the shape and size of the nets were not associated with ITN use. CONCLUSIONS: The use of ITNs in Cameroon was low and varied according to specific factors. These identified factors could be used as the foundations of effective sensitization campaigns on the importance of ITNs.


Subject(s)
Insecticide-Treated Bednets , Insecticides , Malaria , Humans , Prevalence , Cameroon/epidemiology , Cross-Sectional Studies , Malaria/epidemiology , Malaria/prevention & control , Risk Factors , Mosquito Control
15.
Front Cardiovasc Med ; 10: 1150579, 2023.
Article in English | MEDLINE | ID: mdl-37492157

ABSTRACT

Background: The development of microvascular plugs (MVPs) has enabled novel transcatheter deliverable endoluminal pulmonary flow restrictors (PFRs) with the potential to treat newborns and infants with life-threatening congenital heart diseases (CHDs) in a minimally invasive manner. We present our experience to evaluate the efficacy of this concept in controlling pulmonary blood flow in various CHDs. Methods: Retrospective clinical data review of patients with CHD and pulmonary over-circulation who received bilateral PFRs percutaneously. Results: Twenty-eight PFRs (7 MVP-5Q, 12 MVP-7Q, and 9 MVP-9Q) were finally implanted in 14 patients with a median age of 1.6 months (IQR, 0.9-2.3) and a median weight of 3.1 Kg (IQR, 2.7-3.6). Nine patients had large intra-cardiac left-to-right shunts (including 3 with fatal trisomy and palliative programs), 2 had borderline left ventricles, 2 had Taussig-Bing anomaly, and one had a hypoplastic left heart. Four patients had concomitant ductal stenting. Two MVP-5Qs were snare-removed and upsized to MVP-7Q. Patients experienced a significant drop in oxygen saturation and Qp/Qs. All patients were discharged from the ICU after a median of 3.5 days (IQR, 2-5.8) postoperative. Five patients had routine inter-stage catheterization and no device embolization or pulmonary branch distortion was seen. Fourteen (50%) PFRs were surgically explanted uneventfully on a median of 4.3 months (IQR, 1.2-6) post-implantation during biventricular repair in 6 patients and stage-2 palliation in one patient. The latter died 1 month post-operative from severe sepsis. Four patients are scheduled for surgical PFR removal and biventricular repair. Two patients with trisomy 18 died at 1 and 6.8 months post-procedure from non-cardiac causes. One patient with trisomy 13 is alive at 2.7 months post-procedure. Conclusion: It is feasible to bespoke MVPs and implant them as effective PFRs in various CHDs. This approach enables staged left ventricular recruitment, comprehensive stage-2 or biventricular repair with lower risk by postponing surgeries to later infancy. Device explantation is uneventful, and the outcomes afterward are promising.

16.
Commun Biol ; 6(1): 755, 2023 07 28.
Article in English | MEDLINE | ID: mdl-37507515

ABSTRACT

The vacuolar-type ATPase from Enterococcus hirae (EhV-ATPase) is a thus-far unique adaptation of V-ATPases, as it performs Na+ transport and demonstrates an off-axis rotor assembly. Recent single molecule studies of the isolated V1 domain have indicated that there are subpauses within the three major states of the pseudo three-fold symmetric rotary enzyme. However, there was no structural evidence for these. Herein we activate the EhV-ATPase complex with ATP and identified multiple structures consisting of a total of six states of this complex by using cryo-electron microscopy. The orientations of the rotor complex during turnover, especially in the intermediates, are not as perfectly uniform as expected. The densities in the nucleotide binding pockets in the V1 domain indicate the different catalytic conditions for the six conformations. The off-axis rotor and its' interactions with the stator a-subunit during rotation suggests that this non-uniform rotor rotation is performed through the entire complex.


Subject(s)
Vacuolar Proton-Translocating ATPases , Vacuolar Proton-Translocating ATPases/metabolism , Enterococcus hirae/metabolism , Cryoelectron Microscopy , Rotation , Catalysis
17.
Front Cardiovasc Med ; 10: 1155142, 2023.
Article in English | MEDLINE | ID: mdl-37283571

ABSTRACT

Background: Transcatheter closure of atrial septal defects (ASDs) is well-established. However, this procedure can be challenging, requiring multiple attempts and advanced implantation maneuvers. Materials and methods: From July 2019 to July 2022, patients to whom the fast atrial sheath traction (FAST) technique was applied for ASD device closure were prospectively followed up. The device was rapidly unsheathed in the middle of the left atrium (LA) to let it clamp the ASD from both sides simultaneously. This novel technique was directly applied in patients with absent aortic rims and/or ASD size-to-body weight ratio higher than 0.9 or after failed attempts of standard implantation. Results: Seventeen patients (64.7% males) were involved with a median age of 9.8 years [interquartile range (IQR), 7.6-15.1] and a median weight of 34 kg (IQR, 22-44). The median ASD size on ultrasound was 19 mm (IQR, 16-22). Five (29.4%) patients had absent aortic rims, and three (17.6%) patients had an ASD size-to-body weight ratio higher than 0.9. The median device size was 22 mm (IQR, 17-24). The median difference between device size and ASD two-dimensional static diameter was 3 mm (IQR, 1-3). All interventions were straightforward without any complications using three different occluder devices. One device was removed before release and upsized to the next size. The median fluoroscopy time was 4.1 min (IQR, 3.6-4.6). All patients were discharged the next postoperative day. On a median follow-up of 13 months (IQR, 8-13), no complications were detected. All patients achieved full clinical recovery with complete shunt closure. Conclusion: We present a new implantation technique to efficiently close simple and complex ASDs. The FAST technique can be of benefit in overcoming left disc malalignment to the septum in defects with absent aortic rims and in avoiding complex implantation maneuvers and the risks of injuring the pulmonary veins.

18.
Methods Mol Biol ; 2671: 173-210, 2023.
Article in English | MEDLINE | ID: mdl-37308646

ABSTRACT

Protein cages are one of the most widely studied objects in the field of cryogenic electron microscopy-encompassing natural and synthetic constructs, from enzymes assisting protein folding such as chaperonin to virus capsids. Tremendous diversity of morphology and function is demonstrated by the structure and role of proteins, some of which are nearly ubiquitous, while others are present in few organisms. Protein cages are often highly symmetrical, which helps improve the resolution obtained by cryo-electron microscopy (cryo-EM). Cryo-EM is the study of vitrified samples using an electron probe to image the subject. A sample is rapidly frozen in a thin layer on a porous grid, attempting to keep the sample as close to a native state as possible. This grid is kept at cryogenic temperatures throughout imaging in an electron microscope. Once image acquisition is complete, a variety of software packages may be employed to carry out analysis and reconstruction of three-dimensional structures from the two-dimensional micrograph images. Cryo-EM can be used on samples that are too large or too heterogeneous to be amenable to other structural biology techniques like NMR or X-ray crystallography. In recent years, advances in both hardware and software have provided significant improvements to the results obtained using cryo-EM, recently demonstrating true atomic resolution from vitrified aqueous samples. Here, we review these advances in cryo-EM, especially in that of protein cages, and introduce several tips for situations we have experienced.


Subject(s)
Computer Systems , Electrons , Cryoelectron Microscopy , Crystallography, X-Ray , Porosity
19.
JMIR Form Res ; 7: e44373, 2023 May 03.
Article in English | MEDLINE | ID: mdl-37133912

ABSTRACT

BACKGROUND: Previous studies on clinical decision support systems (CDSSs) for the management of renal anemia in patients with end-stage kidney disease undergoing hemodialysis have previously focused solely on the effects of the CDSS. However, the role of physician compliance in the efficacy of the CDSS remains ill-defined. OBJECTIVE: We aimed to investigate whether physician compliance was an intermediate variable between the CDSS and the management outcomes of renal anemia. METHODS: We extracted the electronic health records of patients with end-stage kidney disease on hemodialysis at the Far Eastern Memorial Hospital Hemodialysis Center (FEMHHC) from 2016 to 2020. FEMHHC implemented a rule-based CDSS for the management of renal anemia in 2019. We compared the clinical outcomes of renal anemia between the pre- and post-CDSS periods using random intercept models. Hemoglobin levels of 10 to 12 g/dL were defined as the on-target range. Physician compliance was defined as the concordance of adjustments of the erythropoietin-stimulating agent (ESA) between the CDSS recommendations and the actual physician prescriptions. RESULTS: We included 717 eligible patients on hemodialysis (mean age 62.9, SD 11.6 years; male n=430, 59.9%) with a total of 36,091 hemoglobin measurements (average hemoglobin and on-target rate were 11.1, SD 1.4, g/dL and 59.9%, respectively). The on-target rate decreased from 61.3% (pre-CDSS) to 56.2% (post-CDSS) owing to a high hemoglobin percentage of >12 g/dL (pre: 21.5%; post: 29%). The failure rate (hemoglobin <10 g/dL) decreased from 17.2% (pre-CDSS) to 14.8% (post-CDSS). The average weekly ESA use of 5848 (SD 4211) units per week did not differ between phases. The overall concordance between CDSS recommendations and physician prescriptions was 62.3%. The CDSS concordance increased from 56.2% to 78.6%. In the adjusted random intercept model, the post-CDSS phase showed increased hemoglobin by 0.17 (95% CI 0.14-0.21) g/dL, weekly ESA by 264 (95% CI 158-371) units per week, and 3.4-fold (95% CI 3.1-3.6) increased concordance rate. However, the on-target rate (29%; odds ratio 0.71, 95% CI 0.66-0.75) and failure rate (16%; odds ratio 0.84, 95% CI 0.76-0.92) were reduced. After additional adjustments for concordance in the full models, increased hemoglobin and decreased on-target rate tended toward attenuation (from 0.17 to 0.13 g/dL and 0.71 to 0.73 g/dL, respectively). Increased ESA and decreased failure rate were completely mediated by physician compliance (from 264 to 50 units and 0.84 to 0.97, respectively). CONCLUSIONS: Our results confirmed that physician compliance was a complete intermediate factor accounting for the efficacy of the CDSS. The CDSS reduced failure rates of anemia management through physician compliance. Our study highlights the importance of optimizing physician compliance in the design and implementation of CDSSs to improve patient outcomes.

20.
Cardiol Young ; 33(12): 2597-2603, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37073828

ABSTRACT

BACKGROUND: Low-profile stent implantation remains a rescue treatment for aortic coarctation and branch pulmonary arteries stenosis in small children. Stent re-expansion to cope with vascular growth remains problematic. OBJECTIVES: To evaluate ex vivo feasibility and mechanical behaviour of over-dilating BeSmooth peripheral stents (Bentley InnoMed, Germany). METHODS: Three BeSmooth peripheral stents in diameters of 7, 8, and 10 mm were dilated to nominal pressure and then 13 atm. BeSmooth Ø7 × 23 mm was sequentially post-dilated using 12, 14, and 16 mm high-pressure balloons. BeSmooth Ø10 × 57 mm was post-dilated with a 14 mm balloon and then with a 48 mm bare-metal Optimus XXL stent hand-mounted on a 14 mm balloon (stent-in-stent). BeSmooth Ø8 × 57 mm was directly post-dilated with a 48 mm bare-metal Optimus XXL stent hand-mounted on a 16 mm balloon (stent-in-stent). The stents' diameter and length were measured. Digital inflation pressure was noted. Balloon rupture and stent fracture patterns were closely evaluated. RESULTS: At 20atm pressure, BeSmooth Ø7 × 23 mm shortened to 2 mm forming a 12 mm diameter solid ring circle and the woven balloon ruptured radially. At 10 atm pressure, BeSmooth Ø10 × 57 mm fractured longitudinally in various dispatched breaking points at a diameter of 13 mm without shortening and ruptured the balloon with multiple pinholes. At 10 atm pressure, BeSmooth Ø8 × 57 mm fractured centrally at three different points at a diameter of 11.5 mm without shortening and the balloon broke radially in half. CONCLUSIONS: In our benchmark tests, extreme shortening, severe balloon rupture, or unpredictable stent fracture patterns at small balloon diameters limits safe post-dilation of BeSmooth stents beyond 13 mm. BeSmooth stents are not ideal candidates for off-label stent interventions in smaller patients.


Subject(s)
Angioplasty, Balloon , Child , Adult , Humans , Dilatation , Prosthesis Design , Stents , Stress, Mechanical , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...