Ann Work Expo Health ; 66(4): 459-471, 2022 04 22.
Article in English | MEDLINE | ID: mdl-34864842

ABSTRACT

The goal of this study was to reconstruct the historical respirable silica (RS) and respirable dust (RD) exposures of workers in the Minnesota taconite industry from 1955 to 2010 as part of several epidemiological studies for assessing the association between exposure to components of taconite dusts and the development of respiratory diseases. A job-exposure matrix (JEM) was developed that uses 9127 RS and 19 391 RD occupational hygiene historical measurements. Historical RS and RD data were extracted from several sources and were grouped into seven mines and then into eight departments [Concentrating, Crushing, Janitor, Mining, Office/control room, Pelletizing, Shop (mobile), and Shop (stationary)]. Within each department, we applied a two-level random-intercept regression model which assumes that the natural log of Y (RD or RS concentration) changes over time at a constant rate. Among all predicted RD and RS values, we found that larger RD values were located in the following departments: Crushing, Concentrating, Pelletizing, and Shop (mobile). Larger RS values were located only in either Crushing or Shop (mobile). The annual rates of change for historical RD and RS exposures were between -3.3 and 3.2%. The silica percentage in the dust varied by mine/department with the highest value of 29.3% in Mine F (Crushing) and the lowest value of 2.1% in Mine B (Pelletizing). The predicted historical RD and RS arithmetic mean exposures ranged between <0.075 and 3.14 mg m-3, and between <0.005 and 0.36 mg m-3, respectively. The result of this study is a JEM by mine, department, and year for RD and RS for epidemiological studies.


Subject(s)
Air Pollutants, Occupational , Occupational Exposure , Air Pollutants, Occupational/analysis , Dust/analysis , Humans , Iron , Mining , Occupational Exposure/analysis , Silicates , Silicon Dioxide/analysis
2.
PLoS One ; 16(1): e0244977, 2021.
Article in English | MEDLINE | ID: mdl-33507951

ABSTRACT

Researchers must be able to measure concentrations, sizes, and infectivity of virus-containing particles in animal agriculture facilities to know how far infectious virus-containing particles may travel through air, where they may deposit in the human or animal respiratory tract, and the most effective ways to limit exposures to them. The objective of this study was to evaluate a variety of impinger and cyclone aerosol or bioaerosol samplers to determine approaches most suitable for detecting and measuring concentrations of virus-containing particles in air. Six impinger/cyclone air samplers, a filter-based sampler, and a cascade impactor were used in separate tests to collect artificially generated aerosols of MS2 bacteriophage and swine and avian influenza viruses. Quantification of infectious MS2 coliphage was carried out using a double agar layer procedure. The influenza viruses were titrated in cell cultures to determine quantities of infectious virus. Viral RNA was extracted and used for quantitative real time RT-PCR, to provide total virus concentrations for all three viruses. The amounts of virus recovered and the measured airborne virus concentrations were calculated and compared among the samplers. Not surprisingly, high flow rate samplers generally collected greater quantities of virus than low flow samplers. However, low flow rate samplers generally measured higher, and likely more accurate, airborne concentrations of Infectious virus and viral RNA than high flow samplers. To assess airborne viruses in the field, a two-sampler approach may work well. A suitable high flow sampler may provide low limits of detection to determine if any virus is present in the air. If virus is detected, a suitable lower flow sampler may measure airborne virus concentrations accurately.


Subject(s)
Aerosols/analysis , Air Microbiology , Environmental Monitoring/instrumentation , Orthomyxoviridae/isolation & purification , Agriculture , Animals , Particle Size , RNA, Viral
3.
New Solut ; 30(2): 102-110, 2020 08.
Article in English | MEDLINE | ID: mdl-32345123

ABSTRACT

Introduction of facilitated hands-on drills as often as monthly and the use of online modules prior to annual refresher training for emergency response teams were investigated through surveys and group discussions. This research explores how these drills are perceived by emergency response team members, emergency response team coordinators, instructors, and management at the company. Using these tools throughout the year, members of emergency response teams from automobile manufacturing facilities reported an increased ability to maintain their skill sets, build teamwork, and continually refresh and strengthen their ability to protect their fellow workers as well as plant operations and equipment. The results also document examples of how this innovative program that incorporates frequent training has led to workplace improvements.


Subject(s)
Perception , Humans
4.
Ann Work Expo Health ; 63(1): 77-90, 2019 01 07.
Article in English | MEDLINE | ID: mdl-30351393

ABSTRACT

Studies in environmental epidemiology and of occupational cohorts have implicated the effects of fine particulates with increased risk of cardiovascular diseases. Motivated by this evidence, we conducted an ambient air monitoring campaign to characterize fine aerosol concentrations around various taconite ore processes in six taconite mines in northeastern Minnesota. The ore processes were first categorized into 16 broad work areas/buildings. We then took air samples at 91 fixed locations using an array of direct-reading instruments to obtain measurements of mass (PM2.5 or particles with aerodynamic diameter <2.5 µm, and respirable particulate matter or RPM), alveolar-deposited surface area (ADSA), and particle number (PN) concentrations. At each location, a respirable gravimetric pump (which was used for calibration purposes) and the instruments measured the ambient dust level for 4 h producing ~240 1-min averaging real-time measurements. To analyze these data, we fit a Bayesian hierarchical model with an autoregressive order 1 correlation structure to estimate pooled concentrations for the 16 work areas/buildings while accounting for temporal correlation. PM2.5 and RPM average ambient concentrations were highly correlated to each other (Pearson's correlation = 0.98), followed by ADSA and PN correlation (R = 0.77). Office and control room areas were found to have the lowest concentrations in all four metrics when compared to other groups. Distinguishing between concentration levels among the remaining groups was more difficult due to the high uncertainty associated with the geometric mean estimates. The geometric standard deviation within location (GSDWL) generally ranged from 1 to 3 for all exposure metrics, except for a few locations that may have had changes in the work activities that generated the observed peaks and variability during the sampling duration. The geometric standard deviation between locations estimates were generally higher than GSDWL, which may indicate larger variability in the processes/activities between locations within each broad work area/building. Future work may look into whether it is feasible to use area measurements for epidemiological investigation and use personal measurements (if available) to validate such approach.


Subject(s)
Aerosols/analysis , Air Pollutants/analysis , Environmental Monitoring/methods , Iron , Mining , Occupational Exposure/analysis , Silicates , Bayes Theorem , Benchmarking , Dust/analysis , Humans , Particle Size , Particulate Matter/analysis
5.
J Agromedicine ; 23(1): 40-51, 2018.
Article in English | MEDLINE | ID: mdl-28976266

ABSTRACT

OBJECTIVE: Evolving production practices in the swine industry may alter the working environment. This research characterized the influence of stall versus pen gestation housing and wet versus dry feed in finishing on air contaminant concentrations. METHODS: Eight-hour time-weighted ammonia, hydrogen sulfide, respirable dust, respirable endotoxin, and carbon dioxide concentrations and temperature were measured regularly at stationary locations throughout a year in a facility with parallel gestation stall and open pen housing and parallel finishing rooms using dry and wet feed delivery systems. Hazard indices were calculated using ammonia, hydrogen sulfide, and endotoxin concentrations and relevant occupational exposure limits. Statistical analyses were performed to assess the influence of time of year, housing, and feed on measured parameters. RESULTS: Due to reductions in ventilation rates as outdoor temperatures decreased, season affected pollutant levels more than other factors, with concentrations approximately one order of magnitude greater in winter than during summer. Ammonia, dust, and endotoxin were 25%, 43%, and 67% higher, respectively, on average, in the room with gestation pens than in the room with stalls. Endotoxin concentrations were more than five times higher, on average, with the dry feed system than with wet feed. While individual contaminant concentrations were generally below regulatory limits, hazard index calculations suggest that the effects of combined exposures on respiratory health may present a risk to workers. Elevated levels of respirable endotoxin and hydrogen sulfide were observed during power washing. CONCLUSIONS: Ventilation changes in response to seasonal requirements influenced air contaminant concentrations more than production practices, especially housing type. Wet feed systems substantially reduced airborne endotoxin concentrations.


Subject(s)
Air Pollution, Indoor/analysis , Animal Feed/analysis , Animal Husbandry/methods , Housing, Animal , Air Pollutants, Occupational/analysis , Ammonia/analysis , Animals , Carbon Dioxide/analysis , Endotoxins/analysis , Hydrogen Sulfide/analysis , Occupational Exposure/analysis , Seasons , Swine , Ventilation
6.
Saf Health Work ; 8(3): 296-305, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28951807

ABSTRACT

BACKGROUND: Surfactant-containing water sprays are commonly used in coal mines to collect dust. This study investigates the dust collection performance of different surfactant types for a range of coal dust particle sizes and charges. METHODS: Bituminous coal dust aerosol was generated in a wind tunnel. The charge of the aerosol was either left unaltered, charge-neutralized with a neutralizer, or positively- or negatively-charged using a diffusion charger after the particles were neutralized. An anionic, cationic, or nonionic surfactant spray or a plain water spray was used to remove the particles from the air flow. Some particles were captured while passing through spray section, whereas remaining particles were charge-separated using an electrostatic classifier. Particle size and concentration of the charge-separated particles were measured using an aerodynamic particle sizer. Measurements were made with the spray on and off to calculate overall collection efficiencies (integrated across all charge levels) and efficiencies of particles with specific charge levels. RESULTS: The diameter of the tested coal dust aerosol was 0.89 µm ± 1.45 [geometric mean ± geometric standard deviations (SD)]. Respirable particle mass was collected with 75.5 ± 5.9% (mean ± SD) efficiency overall. Collection efficiency was correlated with particle size. Surfactant type significantly impacted collection efficiency: charged particle collection by nonionic surfactant sprays was greater than or equal to collection by other sprays, especially for weakly-charged aerosols. Particle charge strength was significantly correlated with collection efficiency. CONCLUSION: Surfactant type affects charged particle spray collection efficiency. Nonionic surfactant sprays performed well in coal dust capture in many of the tested conditions.

7.
J Occup Environ Hyg ; 14(8): 634-641, 2017 08.
Article in English | MEDLINE | ID: mdl-28718710

ABSTRACT

The aims of this study were to evaluate sound levels produced by compressed air guns in research and development (R&D) environments, replace conventional air gun models with advanced noise-reducing air nozzles, and measure changes in sound levels to assess the effectiveness of the advanced nozzles as engineering controls for noise. Ten different R&D manufacturing areas that used compressed air guns were identified and included in the study. A-weighted sound level and Z-weighted octave band measurements were taken simultaneously using a single instrument. In each area, three sets of measurements, each lasting for 20 sec, were taken 1 m away and perpendicular to the air stream of the conventional air gun while a worker simulated typical air gun work use. Two different advanced noise-reducing air nozzles were then installed. Sound level and octave band data were collected for each of these nozzles using the same methods as for the original air guns. Both of the advanced nozzles provided sound level reductions of about 7 dBA, on average. The highest noise reductions measured were 17.2 dBA for one model and 17.7 dBA for the other. In two areas, the advanced nozzles yielded no sound level reduction, or they produced small increases in sound level. The octave band data showed strong similarities in sound level among all air gun nozzles within the 10-1,000 Hz frequency range. However, the advanced air nozzles generally had lower noise contributions in the 1,000-20,000 Hz range. The observed decreases at these higher frequencies caused the overall sound level reductions that were measured. Installing new advanced noise-reducing air nozzles can provide large sound level reductions in comparison to existing conventional nozzles, which has direct benefit for hearing conservation efforts.


Subject(s)
Compressed Air , Equipment Design , Noise, Occupational/prevention & control , Research/instrumentation
8.
J Vet Diagn Invest ; 29(3): 298-304, 2017 May.
Article in English | MEDLINE | ID: mdl-28363251

ABSTRACT

Swine and poultry viruses, such as porcine reproductive and respiratory syndrome virus (PRRSV), porcine epidemic diarrhea virus (PEDV), and highly pathogenic avian influenza virus (HPAIV), are economically important pathogens that can spread via aerosols. The reliability of methods for quantifying particle-associated viruses as well as the size distribution of aerosolized particles bearing these viruses under field conditions are not well documented. We compared the performance of 2 size-differentiating air samplers in disease outbreaks that occurred in swine and poultry facilities. Both air samplers allowed quantification of particles by size, and measured concentrations of PRRSV, PEDV, and HPAIV stratified by particle size both within and outside swine and poultry facilities. All 3 viruses were detectable in association with aerosolized particles. Proportions of positive sampling events were 69% for PEDV, 61% for HPAIV, and 8% for PRRSV. The highest virus concentrations were found with PEDV, followed by HPAIV and PRRSV. Both air collectors performed equally for the detection of total virus concentration. For all 3 viruses, higher numbers of RNA copies were associated with larger particles; however, a bimodal distribution of particles was observed in the case of PEDV and HPAIV.


Subject(s)
Air Microbiology , Animal Husbandry , Disease Outbreaks/veterinary , Swine Diseases/transmission , Aerosols , Animals , Farms , Influenza A virus/isolation & purification , Porcine epidemic diarrhea virus/isolation & purification , Porcine respiratory and reproductive syndrome virus/isolation & purification , Poultry , Reproducibility of Results , Swine , Swine Diseases/virology
9.
J Occup Environ Hyg ; 14(5): 377-388, 2017 05.
Article in English | MEDLINE | ID: mdl-28388309

ABSTRACT

This study assessed the present-day levels (year 2010-2011) of exposure to respirable dust (RD) and respirable silica (RS) in taconite mines and evaluated how the mining process influences exposure concentrations. Personal samples (n = 679) were collected to assess exposure levels of workers to RD and RS at six mines in the Mesabi Iron Range of Minnesota. The RD and RS concentrations were measured using the National Institute for Occupational Safety and Health (NIOSH) 0600 and NIOSH 7500, respectively. Between-mine, between-SEG (similar exposure groups), within-SEG, and within-worker components of variability for RD and RS exposures were estimated using a two- or three-way nested random-effects ANOVA model. The majority of RD concentrations across all mines were below the Mine Safety and Health Administration (MSHA) Permissible Exposure Limit (PEL). The highest concentrations of RD were often observed in either the Pelletizing or Crushing departments, which are inherently dusty operations. With a few exceptions, the concentrations of RS in the crushing and concentrating processes were higher than those in the other mining processes, as well as higher than the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV) for RS. The magnetic separation and flotation processes in the concentrating department reduced the levels of RS significantly, and lowered the percentage of quartz in RD in the pelletizing department. There was little variability among the six mines or between the two mineralogically distinct zones for either RD or RS exposures. The between-SEG variability for RS did not differ substantially across most of the mines and was a major component of exposure variance. The within-SEG (or between-worker) variance component was typically the smallest because in many instances one worker from a SEG within a mine was monitored multiple times. Some of these findings were affected by the degree of censoring in each SEG and mine, characteristics of the taconite rock, seasonal effects during sampling, or the tasks assigned to each job in that mine.


Subject(s)
Dust/analysis , Environmental Monitoring , Iron/chemistry , Mining , Occupational Exposure/analysis , Silicates/chemistry , Silicon Dioxide/analysis , Occupational Health
10.
Aerobiologia (Bologna) ; 32(3): 405-419, 2016.
Article in English | MEDLINE | ID: mdl-27616810

ABSTRACT

Influenza A virus (IAV), porcine reproductive and respiratory syndrome virus (PRRSV), porcine epidemic diarrhea virus (PEDV) and Staphylococcus aureus are important swine pathogens capable of being transmitted via aerosols. The electrostatic particle ionization system (EPI) consists of a conductive line that emits negative ions that charge particles electrically resulting in the settling of airborne particles onto surfaces and potentially decreasing the risk of pathogen dissemination. The objectives of this study were to determine the effect of the EPI system on the quantity and viability of IAV, PRRSV, PEDV and S. aureus in experimentally generated aerosols and in aerosols generated by infected animals. Efficiency at removing airborne particles was evaluated as a function of particle size (ranging from 0.4 to 10 µm), distance from the source of ions (1, 2 and 3 m) and relative air humidity (RH 30 vs. 70 %). Aerosols were sampled with the EPI system "off" and "on." Removal efficiency was significantly greater for all pathogens when the EPI line was the closest to the source of aerosols. There was a greater reduction for larger particles ranging between 3.3 and 9 µm, which varied by pathogen. Overall airborne pathogen reduction ranged between 0.5 and 1.9 logs. Viable pathogens were detected with the EPI system "on," but there was a trend to reducing the quantity of viable PRRSV and IAV. There was not a significant effect on the pathogens removal efficiency based on the RH conditions tested. In summary, distance to the source of ions, type of pathogen and particle size influenced the removal efficiency of the EPI system. The reduction in infectious agents in the air by the EPI technology could potentially decrease the microbial exposure for pigs and people in confinement livestock facilities.

11.
Avian Dis ; 60(3): 637-43, 2016 09.
Article in English | MEDLINE | ID: mdl-27610723

ABSTRACT

We investigated the plausibility of aerosol transmission of H5N2 highly pathogenic avian influenza (HPAI) virus during the 2015 spring outbreaks that occurred in the U.S. midwest. Air samples were collected inside and outside of infected turkey and layer facilities. Samples were tested to assess HPAI virus concentration (RNA copies/m(3) of air), virus viability, and virus distribution by particle size. HPAI virus RNA was detected inside and up to 1000 m from infected facilities. HPAI virus was isolated from air samples collected inside, immediately outside, up to 70 m from infected facilities, and in aerosol particles larger than 2.1 µm. Direct exposure to exhausted aerosols proved to be a significant source of environmental contamination. These findings demonstrate HPAI virus aerosolization from infected flocks, and that both the transport of infectious aerosolized particles and the deposition of particles on surfaces around infected premises represent a potential risk for the spread of HPAI.


Subject(s)
Chickens , Disease Outbreaks/veterinary , Influenza in Birds/epidemiology , Influenza in Birds/transmission , Poultry Diseases/epidemiology , Poultry Diseases/transmission , Turkeys , Aerosols , Animals , Influenza A Virus, H5N2 Subtype/physiology , Influenza in Birds/virology , Iowa/epidemiology , Minnesota/epidemiology , Nebraska/epidemiology , Particle Size , Poultry Diseases/virology , Seasons
12.
PLoS One ; 10(8): e0135675, 2015.
Article in English | MEDLINE | ID: mdl-26287616

ABSTRACT

When pathogens become airborne, they travel associated with particles of different size and composition. Particle size determines the distance across which pathogens can be transported, as well as the site of deposition and the survivability of the pathogen. Despite the importance of this information, the size distribution of particles bearing viruses emitted by infectious animals remains unknown. In this study we characterized the concentration and size distribution of inhalable particles that transport influenza A virus (IAV), porcine reproductive and respiratory syndrome virus (PRRSV), and porcine epidemic diarrhea virus (PEDV) generated by acutely infected pigs and assessed virus viability for each particle size range. Aerosols from experimentally infected pigs were sampled for 24 days using an Andersen cascade impactor able to separate particles by size (ranging from 0.4 to 10 micrometer (µm) in diameter). Air samples collected for the first 9, 20 and the last 3 days of the study were analyzed for IAV, PRRSV and PEDV, respectively, using quantitative reverse transcription polymerase chain reaction (RT-PCR) and quantified as geometric mean copies/m(3) within each size range. IAV was detected in all particle size ranges in quantities ranging from 5.5x10(2) (in particles ranging from 1.1 to 2.1 µm) to 4.3x10(5) RNA copies/m(3) in the largest particles (9.0-10.0 µm). PRRSV was detected in all size ranges except particles between 0.7 and 2.1 µm in quantities ranging from 6x10(2) (0.4-0.7 µm) to 5.1x10(4) RNA copies/m(3) (9.0-10.0 µm). PEDV, an enteric virus, was detected in all particle sizes and in higher quantities than IAV and PRRSV (p < 0.0001) ranging from 1.3x10(6) (0.4-0.7 µm) to 3.5x10(8) RNA copies/m(3) (9.0-10.0 µm). Infectious status was demonstrated for the 3 viruses, and in the case of IAV and PRRSV, viruses were isolated from particles larger than 2.1 µm. In summary, our results indicated that airborne PEDV, IAV and PRRSV can be found in a wide range of particle sizes. However, virus viability is particle size dependent.


Subject(s)
Influenza A virus/isolation & purification , Particle Size , Particulate Matter/adverse effects , Porcine epidemic diarrhea virus/isolation & purification , Porcine respiratory and reproductive syndrome virus/isolation & purification , Aerosols , Air Microbiology , Animals , Coronavirus Infections/transmission , Coronavirus Infections/virology , Microbial Viability , Orthomyxoviridae Infections/transmission , Orthomyxoviridae Infections/virology , Porcine Reproductive and Respiratory Syndrome/transmission , Porcine Reproductive and Respiratory Syndrome/virology , RNA, Viral/genetics , Swine , Swine Diseases/virology , Viral Load
13.
J Occup Environ Hyg ; 12(6): 363-8, 2015.
Article in English | MEDLINE | ID: mdl-25626124

ABSTRACT

The goal of this study was to compare and contrast the use of personal protective equipment (PPE) and the practice of handwashing among participants of four studies assessing poultry and swine farms in the midwestern United States and in Thailand. This largely descriptive exercise was designed to assess and compare the frequency of these protective practices among the study populations. There were a total of 1113 surveys analyzed across the four studies. The respondents included workers in direct contact with animals as well as flock owners and veterinarians tending to farms. Handwashing was the most common practice observed among all participants with 42% "always" and 35% "sometimes" washing their hands after contact with the animals. This practice was least common among Minnesota swine workers. Even Thai poultry farmers, who demonstrated the lowest overall PPE use, reported a higher frequency of handwashing. Mask use during animal farming activities ("always" or "sometimes") was least commonly practiced, ranging from 1% in Thailand to 26% among backyard poultry farmers in Minnesota. Minnesota poultry and swine farmers had similar frequencies of mask (26%) and glove use (51% and 49%). All other comparisons differed significantly across the four sites (p-values <0.05). The use of PPE in animal farming differed by study location and is likely related to prevalent norms in the respective regions. Overall, the use of PPE did not appear to be influenced by the particular animal (poultry or swine) being farmed. These findings may prove useful to regulating bodies and farm owners in formulating policy or planning strategies for improving personal hygiene practices in animal farming and preparing for influenza and other potential zoonotic disease outbreaks.


Subject(s)
Animal Husbandry , Hand Disinfection , Personal Protective Equipment/statistics & numerical data , Animals , Disease Outbreaks/prevention & control , Farmers , Gloves, Protective/statistics & numerical data , Humans , Masks/statistics & numerical data , Midwestern United States , Poultry , Shoes , Swine , Thailand , Veterinarians , Zoonoses/prevention & control
15.
J Occup Environ Hyg ; 11(9): 613-24, 2014.
Article in English | MEDLINE | ID: mdl-24512074

ABSTRACT

Different dimensions of elongate mineral particles (EMP) have been proposed as being relevant to respiratory health end-points such as mesothelioma and lung cancer. In this article, a methodology for converting personal EMP exposures measured using the National Institute for Occupational Safety and Health (NIOSH) 7400/7402 methods to exposures based on other size-based definitions has been proposed and illustrated. Area monitoring for EMP in the taconite mines in Minnesota's Mesabi Iron Range was conducted using a Micro Orifice Uniform Deposit Impactor (MOUDI) size-fractionating sampler. EMP on stages of the MOUDI were counted and sized according to each EMP definition using an indirect-transfer transmission electron microscopy (ISO Method 13794). EMP were identified using energy-dispersive x-ray and electron diffraction analysis. Conversion factors between the EMP counts based on different definitions were estimated using (1) a linear regression model across all locations and (2) a location-specific ratio of the count based on each EMP definition to the NIOSH 7400/7402 count. The highest fractions of EMP concentrations were found for EMP that were 1-3 µm in length and 0.2-0.5 µm in width. Therefore, the current standard NIOSH Method 7400, which only counts EMP >5 µm in length and ≥ 3 in aspect ratio, may underestimate amphibole EMP exposures. At the same time, there was a high degree of correlation between the exposures estimated according to the different size-based metrics. Therefore, the various dimensional definitions probably do not result in different dose-response relationships in epidemiological analyses. Given the high degree of correlation between the various metrics, a result consistent with prior research, a more reasonable metric might be the measurement of all EMP irrespective of size. [Supplementary materials are available for this article. Go to the publisher's online edition of Journal of Occupational and Environmental Hygiene for the following free supplemental resource: figures detailing EMP concentration.].


Subject(s)
Air Pollutants, Occupational/analysis , Environmental Monitoring/methods , Inhalation Exposure/analysis , Iron , Mining , Occupational Exposure/analysis , Particulate Matter/analysis , Silicates , Air Pollutants, Occupational/chemistry , Asbestos, Amphibole/analysis , Asbestos, Amphibole/chemistry , Environmental Monitoring/instrumentation , Humans , Linear Models , Minnesota , Particle Size , Particulate Matter/chemistry
16.
Appl Environ Microbiol ; 80(9): 2796-803, 2014 May.
Article in English | MEDLINE | ID: mdl-24561592

ABSTRACT

Laboratory studies of virus aerosols have been criticized for generating airborne viruses from artificial nebulizer suspensions (e.g., cell culture media), which do not mimic the natural release of viruses (e.g., from human saliva). The objectives of this study were to determine the effect of human saliva on the infectivity and survival of airborne virus and to compare it with those of artificial saliva and cell culture medium. A stock of MS2 bacteriophage was diluted in one of three nebulizer suspensions, aerosolized, size selected (100 to 450 nm) using a differential mobility analyzer, and collected onto gelatin filters. Uranine was used as a particle tracer. The resulting particle size distribution was measured using a scanning mobility particle sizer. The amounts of infectious virus, total virus, and fluorescence in the collected samples were determined by infectivity assays, quantitative reverse transcription-PCR (RT-PCR), and spectrofluorometry, respectively. For all nebulizer suspensions, the virus content generally followed a particle volume distribution rather than a number distribution. The survival of airborne MS2 was independent of particle size but was strongly affected by the type of nebulizer suspension. Human saliva was found to be much less protective than cell culture medium (i.e., 3% tryptic soy broth) and artificial saliva. These results indicate the need for caution when extrapolating laboratory results, which often use artificial nebulizer suspensions. To better assess the risk of airborne transmission of viral diseases in real-life situations, the use of natural suspensions such as saliva or respiratory mucus is recommended.


Subject(s)
Culture Media/chemistry , Levivirus/growth & development , Saliva, Artificial/chemistry , Saliva/virology , Air/analysis , Air Microbiology , Humans
17.
J Occup Environ Hyg ; 11(9): 571-82, 2014.
Article in English | MEDLINE | ID: mdl-24479508

ABSTRACT

This research measured the effects of particle diameter, surfactant-containing spray solution, and particle charge on the capture of respirable particles by surfactant-containing water spray droplets. Polystyrene latex particles with diameters of 0.6, 1.0, or 2.1 µm were generated in a wind tunnel. Particles were given either a neutralized, unneutralized, net positive, or net negative charge, and then were captured as they passed through sprays containing anionic, cationic, or nonionic surfactant. The remaining particles were sampled, charge-separated, and counted with the sprays on and off at varying voltage levels to assess collection efficiency. Overall efficiencies were measured for particles with all charge levels, as well as efficiencies for particles with specific charge levels. The overall collection efficiency significantly increased with increasing particle diameter. Collection efficiencies of 21.5% ± 9.0%, 58.8% ± 12.5%, and 86.6% ± 43.5% (Mean ± SD) were observed for particles 0.6, 1.0, and 2.1 µm in diameter, respectively. The combination of surfactant classification and concentration also significantly affected both overall spray collection efficiency and collection efficiency for particles with specific charge levels. Ionic surfactant-containing sprays had the best performance for charged particles with the opposite sign of charge but the worst performance for charged particles with the same sign of charge, while nonionic surfactant-containing spray efficiently removed particles carrying relatively few charges. Particle charge level impacted the spray collection efficiency. Highly charged particles were removed more efficiently than weakly charged particles.


Subject(s)
Air Pollutants, Occupational/chemistry , Polystyrenes/chemistry , Static Electricity , Surface-Active Agents/chemistry , Water/chemistry , Air Pollutants, Occupational/analysis , Humans , Inhalation Exposure/prevention & control , Occupational Exposure/prevention & control , Occupational Health , Particle Size , Polystyrenes/analysis
18.
Ann Occup Hyg ; 57(8): 966-78, 2013 Oct.
Article in English | MEDLINE | ID: mdl-23792972

ABSTRACT

Since the 1970s, concerns have been raised about elevated rates of mesothelioma in the vicinity of the taconite mines in the Mesabi Iron Range. However, insufficient quantitative exposure data have hampered investigations of the relationship between cumulative exposures to elongate mineral particles (EMP) in taconite dust and adverse health effects. Specifically, no research on exposure to taconite dust, which includes EMP, has been conducted since 1990. This article describes a comprehensive assessment of present-day exposures to total and amphibole EMP in the taconite mining industry. Similar exposure groups (SEGs) were established to assess present-day exposure levels and buttress the sparse historical data. Personal samples were collected to assess the present-day levels of worker exposures to EMP at six mines in the Mesabi Iron Range. The samples were analyzed using National Institute for Occupational Safety and Health (NIOSH) methods 7400 and 7402. For many SEGs in several mines, the exposure levels of total EMP were higher than the NIOSH Recommended Exposure Limit (REL). However, the total EMP classification includes not only the asbestiform EMP and their non-asbestiform mineral analogs but also other minerals because the NIOSH 7400 cannot differentiate between these. The concentrations of amphibole EMP were well controlled across all mines and were much lower than the concentrations of total EMP, indicating that amphibole EMP are not major components of taconite EMP. The levels are also well below the NIOSH REL of 0.1 EMP cc(-1). Two different approaches were used to evaluate the variability of exposure between SEGs, between workers, and within workers. The related constructs of contrast and homogeneity were calculated to characterize the SEGs. Contrast, which is a ratio of between-SEG variability to the sum of between-SEG and between-worker variability, provides an overall measure of whether there are distinctions between the SEGs. Homogeneity, which is the ratio of the within-worker variance component to the sum of the between-worker and within-worker variance components, provides an overall measure of how similar exposures are for workers within an SEG. Using these constructs, it was determined that the SEGs are formed well enough when grouped by mine for both total and amphibole EMP to be used for epidemiological analysis.


Subject(s)
Air Pollutants, Occupational/analysis , Iron/adverse effects , Mining , Occupational Exposure/analysis , Silicates/adverse effects , Analysis of Variance , Asbestos, Amphibole/analysis , Humans , Inhalation Exposure/analysis , Lung Neoplasms/etiology , Mesothelioma , Minnesota/epidemiology , Occupational Exposure/adverse effects , Reproducibility of Results , Respiratory Tract Diseases , United States/epidemiology
19.
Ann Occup Hyg ; 57(2): 221-9, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23065674

ABSTRACT

Conventional abrasive sanding generates high concentrations of particles. Depending on the substrate being abraded and exposure duration, overexposure to the particles can cause negative health effects ranging from respiratory irritation to cancer. The goal of this study was to understand the differences in particle emissions between a conventional random orbital sanding system and a self-generated vacuum random orbital sanding system with attached particle filtration bag. Particle concentrations were sampled for each system in a controlled test chamber for oak wood, chromate painted (hexavalent chromium) steel panels, and gel-coated (titanium dioxide) fiberglass panels using a Gesamtstaub-Probenahmesystem (GSP) sampler at three different locations adjacent to the sanding. Elevated concentrations were reported for all particles in the samples collected during conventional sanding. The geometric mean concentration ratios for the three substrates ranged from 320 to 4640 times greater for the conventional sanding system than the self-generated vacuum sanding system. The differences in the particle concentration generated by the two sanding systems were statistically significant with the two sample t-test (P < 0.0001) for all three substances. The data suggest that workers using conventional sanding systems could utilize the self-generated vacuum sanding system technology to potentially reduce exposure to particles and mitigate negative health effects.


Subject(s)
Air Pollutants, Occupational/analysis , Environmental Monitoring/instrumentation , Industry/instrumentation , Models, Theoretical , Air Pollutants, Occupational/chemistry , Asthma/prevention & control , Chromium/adverse effects , Chromium/analysis , Humans , Inhalation Exposure/analysis , Nanoparticles/analysis , Neoplasms/prevention & control , Occupational Exposure/analysis , Particle Size , Predictive Value of Tests , Titanium/adverse effects , Titanium/analysis , Vacuum , Wood/adverse effects , Wood/analysis
20.
J Occup Environ Hyg ; 9(1): 1-13, 2012.
Article in English | MEDLINE | ID: mdl-22168254

ABSTRACT

This study was conducted to determine if engineered nanoparticles are released into the air when nanocomposite parts are shredded for recycling. Test plaques made from polypropylene resin reinforced with either montmorillonite nanoclay or talc and from the same resin with no reinforcing material were shredded by a granulator inside a test apparatus. As the plaques were shredded, an ultrafine condensation particle counter; a diffusion charger; a photometer; an electrical mobility analyzer; and an optical particle counter measured number, lung-deposited surface area, and mass concentrations and size distributions by number in real-time. Overall, the particle levels produced were both stable and lower than found in some occupational environments. Although the lowest particle concentrations were observed when the talc-filled plaques were shredded, fewer nanoparticles were generated from the nanocomposite plaques than when the plain resin plaques were shredded. For example, the average particle number concentrations measured using the ultrafine condensation particle counter were 1300 particles/cm(3) for the talc-reinforced resin, 4280 particles/cm(3) for the nanoclay-reinforced resin, and 12,600 particles/cm(3) for the plain resin. Similarly, the average alveolar-deposited particle surface area concentrations measured using the diffusion charger were 4.0 µm(2)/cm(3) for the talc-reinforced resin, 8.5 µm(2)/cm(3) for the nanoclay-reinforced resin, and 26 µm(2)/cm(3) for the plain resin. For all three materials, count median diameters were near 10 nm during tests, which is smaller than should be found from the reinforcing materials. These findings suggest that recycling of nanoclay-reinforced plastics does not have a strong potential to generate more airborne nanoparticles than recycling of conventional plastics.


Subject(s)
Air Pollutants, Occupational/analysis , Environmental Monitoring/methods , Nanocomposites , Nanoparticles/analysis , Recycling , Bentonite/analysis , Environmental Monitoring/instrumentation , Microscopy, Electron, Scanning , Polypropylenes/analysis , Resins, Synthetic/analysis , Talc/analysis