Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 23
Filter
1.
J Clin Med ; 13(12)2024 Jun 14.
Article in English | MEDLINE | ID: mdl-38930026

ABSTRACT

Background/Objectives: To date, data regarding the characteristics and management of obstructive, stable coronary artery disease (CAD) encountered in patients undergoing transcatheter aortic valve implantation (TAVI) are sparse. The aim of the study was to analyze granular details, treatment, and outcomes of patients undergoing TAVI with obstructive, stable CAD from real-world practice. Methods: REVASC-TAVI (Management of myocardial REVASCularization in patients undergoing Transcatheter Aortic Valve Implantation with coronary artery disease) is an investigator-initiated, multicenter registry, which collected data from patients undergoing TAVI with obstructive stable CAD found during the pre-TAVI work-up. Results: A total of 2025 patients from 30 centers worldwide with complete follow-up were included in the registry. Most patients had single-vessel CAD (56.1%). An involvement of proximal coronary tracts was detected in 62.5% of cases, with 12.0% of patients having CAD in left main (LM). Most patients received percutaneous coronary intervention (PCI) (n = 1617, 79.9%), especially those with proximal CAD (90.4%). At 2 years, the rates of all-cause death [Kaplan-Meier (KM) estimates 20.1% vs. 18.8%, plog-rank = 0.86] and of the composite of all-cause death, stroke, myocardial infarction, and rehospitalization for heart failure (KM estimates 29.7% vs. 27.5%, plog-rank = 0.82) did not differ between patients undergoing PCI and those who were not. Conclusions: Patients undergoing TAVI with obstructive CAD more commonly had a single-vessel disease and an involvement of proximal coronary tracts. They were commonly treated with PCI, with similar outcomes compared to those treated conservatively.

2.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38479968

ABSTRACT

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Prosthesis Design , Treatment Outcome , Registries , Stroke/etiology
3.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38401656

ABSTRACT

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Prosthesis Design , Registries , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/methods , Male , Female , Aortic Valve Stenosis/surgery , Sex Factors , Aged, 80 and over , Aged , Treatment Outcome , Postoperative Complications/epidemiology , Aortic Valve/surgery
4.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37982161

ABSTRACT

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Heart Valve Prosthesis/adverse effects , Treatment Outcome , Registries , Stroke/etiology , Prosthesis Design
5.
CJC Open ; 5(6): 404-411, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37397616

ABSTRACT

Background: Oral anticoagulation (OAC) is deemed a relative contraindication after intracranial hemorrhage (ICH) if the cause cannot be eliminated and the risk of recurrence is high. That leaves atrial fibrillation (AF) patients at high risk of thromboembolic events. Endovascular left atrial appendage closure (LAAC) can be an alternative to OAC for patients requiring stroke prevention. Methods: We performed a retrospective single-centre analysis of 138 consecutive ICH patients with nonvalvular AF and high stroke risk who underwent LAAC between 2010 and 2022 at Vancouver General Hospital. We report the baseline characteristics, procedural results, and follow-up data, comparing the observed stroke/transient ischemic attack (TIA) rate with the predicted event rate based on their CHA2DS2-VASc scores. Results: The average age was 76.1 ± 8.5 years; the mean CHA2DS2-VASc score was 4.4 ± 1.5; and the mean HAS-BLED score was 3.7 ± 0.9. The procedural success rate was 98.6%, and the complication rate was 3.6% with no periprocedural death, stroke, or TIA. The antithrombotic regimen post-LAAC consisted of short-term dual antiplatelet therapy (1-6 months) followed by aspirin alone for a minimum of 6 months in 86.2%. At mean follow-up of 14.7 ± 13.7 months, 9 deaths (6.5%, 7 cardiovascular, 2 noncardiovascular), 2 strokes (1.4%), and 1 TIA (0.7%) had occurred. The annualized observed stroke/TIA rate was 1.8%, which was lower than the adjusted predicted stroke rate of 7.0% (95% confidence interval: 4.8%-9.2%). Two patients (1.5%) suffered another ICH (both on aspirin monotherapy). One device-related thrombus (0.7%) was confirmed and treated with OAC without sequelae. Conclusion: Endovascular LAAC is a feasible alternative to OAC for stroke prevention in patients with nonvalvular AF and prior ICH.


Contexte: L'anticoagulation par voie orale (ACO) est considérée comme une contre-indication relative après une hémorragie intracrânienne (HIC) si la cause ne peut être éliminée et si le risque de récidive est élevé. Les patients souffrant de fibrillation auriculaire (FA) sont donc exposés à un risque élevé d'événements thromboemboliques. La technique de fermeture percutanée de l'appendice auriculaire gauche (AAG) peut être une solution de rechange aux anticoagulants oraux en prévention des accidents vasculaires cérébraux (AVC). Méthodologie: Nous avons réalisé une analyse rétrospective unicentrique auprès de 138 patients consécutifs qui étaient atteints d'une HIC accompagnée d'une FA non valvulaire ainsi que d'un risque élevé d'AVC et qui ont subi une fermeture de l'AAG entre 2010 et 2022 à l'hôpital général de Vancouver. Nous présentons ici les caractéristiques initiales, les résultats de l'intervention et les données de suivi, en comparant le taux d'AVC/AIT (accident ischémique transitoire) observé avec le taux prédit d'événements sur la base de leurs scores CHA2DS2-VASc. Résultats: L'âge moyen était de 76,1 ± 8,5 ans. Le score CHA2DS2-VASc moyen était de 4,4 ± 1,5, et le score HAS-BLED moyen de 3,7 ± 0,9. Le taux de réussite de l'intervention a été de 98,6 % et le taux de complications de 3,6 %, sans décès périopératoires, ni AVC ou AIT. Le traitement antithrombotique après la fermeture de l'AAG consistait en une bithérapie antiplaquettaire de courte durée (de 1 à 6 mois), suivie de la prise d'aspirine seule pendant au moins 6 mois dans 86,2 % des cas. Après un suivi moyen de 14,7 ± 13,7 mois, 9 décès (6,5 %, 7 d'origine cardiovasculaire et 2 d'origine non cardiovasculaire), 2 AVC (1,4 %) et 1 AIT (0,7 %) sont survenus. Le taux annualisé d'AVC/AIT observé était de 1,8 %, ce qui est inférieur au taux prédit d'AVC après ajustement, soit 7,0 % (intervalle de confiance à 95 % : 4,8 % à 9,2 %). Deux patients (1,5 %) ont souffert d'une autre HIC (tous deux sous aspirine en monothérapie). Un thrombus lié au dispositif (0,7 %) a été confirmé et traité par anticoagulathérapie orale sans séquelles. Conclusion: La technique de fermeture de l'AAG représente une solution de rechange à l'anticoagulation par voie orale dans la prévention des AVC chez les patients souffrant de FA non valvulaire et ayant déjà subi une HIC.

8.
Minerva Cardiol Angiol ; 71(3): 311-320, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36305774

ABSTRACT

BACKGROUND: The safety of concomitant percutaneous coronary intervention (PCI) during transcatheter aortic valve implantation (TAVI) setting is still highly debated. This study aimed to assess the safety and the effectiveness of TAVI and PCI performed in the same session compared with TAVI alone. METHODS: Patients with severe aortic stenosis and coronary artery disease (CAD) (N.=786) who underwent TAVI from June 2007 to April 2021 were divided into two groups: patients who underwent TAVI alone (N.=633) and patients treated with TAVI and concomitant PCI (N.=153). The propensity-score matching adjustment was used to account for baseline confounding variables. RESULTS: A total of 302 TAVI with CAD patients (151 matched pairs), undergoing either isolated TAVI or TAVI+PCI were compared. In-hospital death (6% vs. 4%; P=0.427), stroke (2% vs. 0.7%; P=0.314), myocardial infarction (MI) (0% vs. 0.7%; P=0.317), major and life-threatening bleeding (14.6% vs. 15.9%; P=0.749), and acute kidney injury (9.3% vs. 10.6%; P=0.700) were similar for both groups. At 3 years, the rates of all-cause death (25.2% vs. 19.2%; P=0.615), the composite endpoints of all-cause death and MI (27.2% vs. 21.2%; P=0.699) and all-cause death, MI, and stroke (28.5% vs. 22.5%; P=0.739) were also comparable between the two groups. Achieving complete coronary revascularization in the TAVI setting did not impact on long-term mortality (P=0.257). CONCLUSIONS: In patients with severe aortic stenosis and CAD, concomitant TAVI and PCI was as safe and effective as TAVI alone up to 3-year follow-up.


Subject(s)
Aortic Valve Stenosis , Coronary Artery Disease , Myocardial Infarction , Percutaneous Coronary Intervention , Stroke , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Percutaneous Coronary Intervention/adverse effects , Hospital Mortality , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Coronary Artery Disease/surgery , Myocardial Infarction/epidemiology , Myocardial Infarction/surgery , Stroke/complications
9.
Eur Heart J Suppl ; 24(Suppl I): I170-I174, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36380774

ABSTRACT

New insights into the natural history and pathophysiology of patients with aortic stenosis (AS), coupled with the dramatic evolution of transcatheter aortic valve implantation (TAVI), are fuelling intense interest in the management of asymptomatic patients with severe AS. This patient presenting for elective intervention poses a unique challenge. These patients are not traditionally offered surgical aortic valve replacement or TAVI given their lack of symptoms; however, they are at increased risk given the severity of their AS. Furthermore, clinical experience has shown that symptoms can be challenging to ascertain in many sedentary, deconditioned, and/or elderly patients. In addition, evolving data based on imaging and biomarker evidence of adverse ventricular remodelling, hypertrophy, inflammation, or fibrosis may radically transform existing clinical decision paradigms. However, management of asymptomatic severe AS is otherwise controversial and the decision to intervene requires careful assessment of the benefits and risks in an individual patient. Further randomized trials [EARLY TAVI (NCT03042104), AVATAR (NCT02436655), EVOLVED (NCT03094143)] will help determine future recommendations.

10.
Expert Rev Med Devices ; 19(8): 599-612, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36150162

ABSTRACT

INTRODUCTION: Although transcatheter aortic valve implantation (TAVI) has become a streamlined and standardized procedure, different complications still remain and need the operators to be properly trained about their management. AREAS COVERED: This review article aims at offering a practical overview of the most impactful TAVI complications, analyzing, and discussing the potential risk factors, and focusing on the available strategies for their management. EXPERT OPINION: Complications following TAVI have been decreasing thanks to technical advancements and operators experience. The thorough knowledge of potential complications and their prevention played a key role in the decreasing of complications rates. Pre-procedural, computed tomography angiography assessment of patient's anatomical characteristics allows to properly choose and tailor the best strategy for managing complications in most cases. Nevertheless, further research is required to shed light on the optimal strategies to adopt for managing TAVI complications.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/methods , Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Angiography , Tomography, X-Ray Computed , Treatment Outcome , Heart Valve Prosthesis/adverse effects
11.
JACC Cardiovasc Interv ; 15(23): 2398-2407, 2022 12 12.
Article in English | MEDLINE | ID: mdl-36121242

ABSTRACT

BACKGROUND: The latest iterations of devices for transcatheter aortic valve replacement (TAVR) have brought refinements to further improve patient outcomes. OBJECTIVES: This study sought to compare early outcomes of patients undergoing TAVR with the self-expanding (SE) Evolut PRO/PRO+ (Medtronic, Inc) or balloon-expandable (BE) Sapien 3 ULTRA (Edwards Lifesciences) devices. METHODS: The OPERA-TAVI (Comparative Analysis of Evolut PRO vs Sapien 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry collected data from 14 high-volume centers worldwide on patients undergoing TAVR with SE or BE devices. After excluding patients who were not eligible for both devices, patients were compared using 1:1 propensity score matching. The primary efficacy and safety outcomes were Valve Academic Research Consortium-3 device success and early safety, respectively. RESULTS: Among 2,241 patients eligible for the present analysis, 683 pairs of patients were matched. The primary efficacy outcome did not differ between patients receiving SE or BE transcatheter aortic valves (SE: 87.4% vs BE: 85.9%; P = 0.47), but the BE device recipients showed a higher rate of the primary safety outcome (SE: 69.1% vs BE: 82.6%; P < 0.01). This finding was driven by the higher rates of permanent pacemaker implantation (SE: 17.9% vs BE: 10.1%; P < 0.01) and disabling stroke (SE: 2.3% vs BE: 0.7%; P = 0.03) in SE device recipients. On post-TAVR echocardiography, the rate of moderate to severe paravalvular regurgitation was similar between groups (SE: 3.2% vs BE: 2.3%; P = 0.41), whereas lower mean transvalvular gradients were observed in the SE cohort (median SE: 7.0 vs BE: 12.0 mm Hg; P < 0.01). CONCLUSIONS: The OPERA-TAVI registry showed that SE and BE devices had comparable Valve Academic Research Consortium-3 device success rates, but the BE device had a higher rate of early safety. The higher permanent pacemaker implantation and disabling stroke rates in SE device recipients drove this composite endpoint.


Subject(s)
Heart Valve Prosthesis , Stroke , Transcatheter Aortic Valve Replacement , Humans , Stroke/etiology , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
12.
G Ital Cardiol (Rome) ; 23(6): 461-468, 2022 Jun.
Article in Italian | MEDLINE | ID: mdl-35674037

ABSTRACT

BACKGROUND: To assess the longitudinal changes in transcatheter aortic valve implantation (TAVI) practice and patients' outcomes in a high-volume Italian center. METHODS: We analyzed all patients undergoing TAVI at our Institution from June 2007 to August 2021. We stratified the overall population considering four time periods according to procedural advancements and changes in clinical practice: period 1 (2007-2009, n=107) vs period 2 (2010-2014, n=449) vs period 3 (2015-2019, n=864) vs period 4 (2019-2021, n=638). Baseline and procedural characteristics, and in-hospital outcomes among the four groups were compared. RESULTS: A total of 2058 patients underwent TAVI receiving all the available devices. Patients had a median age of 82 years (78-85) with no differences among time periods. A stepwise reduction of median Society of Thoracic Surgeons mortality risk score (3.7 [2.8-5.3] vs 3.6 [2.6-5.4] vs 3.6 [2.5-5.5] vs 3.3 [2.2-4.9]; p=0.01) was observed. In-hospital all-cause-death (7.5% vs 5.1% vs 2.9% vs 3.0%; p<0.05), major stroke (4.7% vs 0.7% vs 1.0% vs 0.8%; p<0.05), major vascular complications (17.8% vs 8.7% vs 10.5% vs 5.8%; p<0.05) and permanent pacemaker implantation (23.4% vs 12.0% vs 8.7% vs 8.8%; p<0.05) rates significantly lowered over time. Device success markedly improved (80.4% vs 87.1% vs 95.0% vs 96.3%; p<0.05) with significant improvement of paravalvular regurgitation after TAVI (moderate-to-severe 16.8% vs 8.1% vs 0.7% vs 0.2%; mild 61.4% vs 38.2% vs 38.5% vs 25.6%; p<0.05). CONCLUSIONS: All-cause death and in-hospital outcomes of patients undergoing TAVI significantly improved accordingly to technical advancements and changes in clinical practice over 15-year experience.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Fluoroscopy , Humans , Retrospective Studies , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
13.
Int J Cardiol ; 361: 55-60, 2022 08 15.
Article in English | MEDLINE | ID: mdl-35500820

ABSTRACT

OBJECTIVES: The aim of this study was to evaluate outcomes of real-world patients with aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR) with the 34 mm Evolut R (Medtronic, Minneapolis, Minnesota). BACKGROUND: Larger aortic annulus has been associated with increased incidence of paravalvular leaks (PVLs) after TAVR. However, little is known, so far, about the performance of the 34 mm Evolut R in this setting. METHODS: From the multicenter, international, retrospective Horizontal Aorta in Transcatheter Self-expanding Valves (HORSE) registry, including patients who underwent TAVR for native severe AS, we selected patients treated with the 34 mm Evolut R evaluating procedural characteristics and VARC-2 defined device success. We also compared 34 mm Evolut R with other Evolut R sizes. RESULTS: Among the 4434 patients included in the registry, 572 (13%) received the 34 mm Evolut R valve. Mean age was 80.8 ± 6.5 years and the median STS PROM score was 4 [interquartile range 2-6]. Device success was achieved in 87.4% with 7.7% of PVLs; moreover, the rate of permanent pacemaker implantation (PPMI) was 22.4%. Patients who underwent 34 mm Evolut R implantation experienced more in-hospital permanent pacemaker implantation (22.4% vs. 15%; p < 0.001). At multivariate analysis, 34 mm Evolut R did not affect device success (OR: 0.81 [0.60-1.09]; p = 0.151). Device success was consistent with other THVs sizes (87.4% vs. 89.6%; p = 0.157). CONCLUSIONS: THV replacement in patients requiring 34 mm Evolut R has an acceptable performance. Compared to other Medtronic sizes it demonstrated to be comparable in terms of device success, despite an increased rate of pacemaker implantation.


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/etiology , Aortic Valve Stenosis/surgery , Humans , Prosthesis Design , Registries , Retrospective Studies , Time Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
14.
JACC Case Rep ; 4(2): 83-86, 2022 Jan 19.
Article in English | MEDLINE | ID: mdl-35106489

ABSTRACT

Achieving patient-specific commissural alignment of transcatheter aortic valves is particularly important to ensure coronary reaccess after transcatheter aortic valve implantation. Nevertheless, in case of uncommon origin of coronary arteries, commissural alignment could be counterproductive. This case shows how alignment techniques could serve to intentionally misalign the neocommissures in this subset of patients. (Level of Difficulty: Intermediate.).

15.
Int J Cardiol ; 352: 190-194, 2022 04 01.
Article in English | MEDLINE | ID: mdl-35077726

ABSTRACT

BACKGROUND: The coronavirus 2019 (COVID-19) pandemic upset healthcare systems and their logistics worldwide. We sought to assess safety and effectiveness of an optimized logistics for transcatheter aortic valve implantation (TAVI) pathway developed during the COVID-19 pandemic. METHODS: This is a retrospective analysis. An optimized TAVI logistics based on performing TAVI work-up and procedure during the same hospitalization was used during the COVID-19 pandemic. In-hospital and 30-day outcomes of patients treated during the pandemic were compared with an historical cohort of patients undergoing TAVI with staged work-up before the pandemic within an homogeneous timeframe. RESULTS: Of 536 patients, 227 (42.4%) underwent TAVI during the COVID-19 pandemic with a reduction of 26.5% compared to the pre-pandemic period (n = 309). The median age was 81 (77-85) years and STS score was 3.4 (2.2-5.6)%. Lower rates of in-hospital major vascular complications (2.2% vs. 8.7%; p < 0.01) and life-threatening bleeding (0.4% vs. 4.2%; p = 0.01) were reported in the COVID-19 period, whereas no difference in acute kidney injury (7.0% vs. 7.4%, p = 0.85) rate was reported between COVID-19 and pre-COVID-19 periods. No difference in 30-day rates of all-cause death (4.0 vs. 4.5, p = 0.75) and of major adverse cardiovascular events (4.0 vs. 6.1, p = 0.26) were reported between COVID-19 and pre-COVID-19 periods. CONCLUSIONS: The use of optimized single-hospitalization logistics for TAVI workup and procedure developed during the COVID-19 pandemic, showed to be as safe and effective as the two-stage TAVI pathway previously adopted, allowing the minimization of potential exposure to COVID-19 infection and shortening times to treatment for severely symptomatic patients.


Subject(s)
Aortic Valve Stenosis , COVID-19 , Transcatheter Aortic Valve Replacement , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , COVID-19/epidemiology , Delivery of Health Care , Humans , Pandemics , Retrospective Studies , SARS-CoV-2 , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome
17.
Int J Cardiol ; 338: 58-62, 2021 09 01.
Article in English | MEDLINE | ID: mdl-34090956

ABSTRACT

BACKGROUND: Horizontal aorta (HA) is an anatomical feature that can pose significant technical challenges for the successful positioning of the bioprosthetic valve during transcatheter aortic valve replacement (TAVR). Physiological range of aortic angle (AA) is unknown; hence there is no cutoff AA for classifying HA. Moreover, patient characteristics predicting HA are under-investigated. METHODS: This was a retrospective analysis of prospective collected data from 16 heart valve centers in Europe. The study utilized a common dataset with a priori agreed-upon definitions and variables. Eligible patients underwent TAVR between 2014 and 2020 and had multidetector computed tomographic imaging data available for determining the AA. The analysis described the distribution of AA and potential predictors of HA. Inter-center variability was also explored. RESULTS: For 4022 patients analyzed, the mean AA ± standard deviation was 49.4° ± 9.4° (median 49°, inter-quartile range [IQR] 12°, range 18-90°). There was no significant difference in mean AA between men and women (49.4° ± 9.1° vs. 49.6° ± 9.3°, respectively; p = 0.53); therefore, 49.4° was accepted as the cutoff value for HA in subsequent analyses. Covariates significantly associated with HA included age (odds ratio [OR]: 1.02, 95% confidence interval [CI]: 1.01-1.04, p < 0.001), body mass index (OR: 1.06, 95% CI: 1.05-1.08, p < 0.01), previous cardiac surgery (OR: 0.58, 95% CI: 0.45-0.75, p < 0.001), and porcelain aorta (OR: 0.66, 95% CI: 0.52-0.85, p = 0.001). Some inter-center variability was observed. CONCLUSIONS: We defined 49.4° as the mean AA, and also associated predictors of HA in a large case series of patients with severe aortic stenosis candidates for TAVR.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aorta , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Europe , Female , Humans , Male , Prospective Studies , Retrospective Studies , Risk Factors , Severity of Illness Index , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
18.
EuroIntervention ; 17(9): 728-735, 2021 Oct 20.
Article in English | MEDLINE | ID: mdl-33589411

ABSTRACT

BACKGROUND: Vascular complications still represent an important issue after transcatheter aortic valve implantation (TAVI). AIMS: The aim of this study was to evaluate the effectiveness of upfront use of an adjunctive Angio-Seal (AS) plug-based system on top of suture-based devices (SBDs) for endovascular haemostasis after transfemoral (TF) TAVI. METHODS: From January 2019 to April 2020, 332 consecutive patients with preprocedural computed tomography angiography (CTA) assessment underwent fully percutaneous TF-TAVI. The primary outcomes were 30-day major vascular complications and major or life-threatening (LT) bleeding due to endovascular closure system failure. A total of 246 TF-TAVI patients (123 pairs), undergoing either isolated SBD or SBD+AS, were matched using the propensity-score method. RESULTS: At 30 days, patients receiving SBD+AS had lower rates of major/LT bleeding (1.6% vs 8.9%, odds ratio [OR] 0.17, 95% confidence interval [CI]: 0.04-0.78; p<0.01) and major vascular complications (1.6% vs 8.9%, OR 0.17, 95% CI: 0.04-0.78; p<0.01). In addition, the use of SBD+AS was associated with a significant cost saving related to the vascular event (mean difference -315.3 € per patient, 95% CI: -566.4 € to -64.1 €; p=0.01), and a higher probability of next-day discharge (NDD) after TAVI (30.9% vs 16.3%, OR 2.30, 95% CI: 1.25-4.25; p<0.01). No difference in all-cause 30-day mortality was observed (3.3% vs 1.6% for SBD and SBD+AS groups, respectively, OR 0.49, 95% CI: 0.09-2.74; p=0.41). CONCLUSIONS: An upfront combined strategy with an additional AS plug-based device on top of SBDs was shown to reduce major vascular complications and major/LT bleeding due to closure system failure after TF-TAVI. This approach was associated with a cost saving and with a higher probability of NDD compared to the use of isolated SBD. Visual summary. Effectiveness of the upfront combined strategy for endovascular haemostasis in transfemoral transcatheter aortic valve implantation using Angio-Seal on top of a suture-based device (SBD) versus the isolated use of SBD. LT: life-threatening; TF-TAVI: transfemoral transcatheter aortic valve implantation.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Hemostasis , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
19.
Eur Heart J Suppl ; 22(Suppl L): L140-L145, 2020 Nov.
Article in English | MEDLINE | ID: mdl-33239989

ABSTRACT

Aortic stenosis (AS) is one of the most common valvular diseases in developed countries. Transcatheter aortic valve implantation (TAVI) has emerged as alternative to medical treatment or surgical aortic valve replacement (SAVR) in all symptomatic patients with severe AS. In 2002, Cribier performed the first human TAVI through a trans-septal approach in a 57-year-old man with severe AS. Since then, several trials have compared TAVI vs. SAVR over the years. Today, it is superior in terms of mortality to medical therapy in extreme-risk patients, non-inferior or superior to surgery in high-risk patients, and non-inferior to surgery and even superior when transfemoral access is possible in intermediate-risk patients. Interesting results emerged from the latest multicentre trials involving patients with severe AS who were at low risk for death from surgery, demonstrating that this therapy will be offered to younger people in the next future.

20.
JACC Cardiovasc Interv ; 13(21): 2542-2555, 2020 11 09.
Article in English | MEDLINE | ID: mdl-33069648

ABSTRACT

OBJECTIVES: The aims of this study were to investigate the feasibility of coronary ostia cannulation after transcatheter aortic valve replacement (TAVR) and to assess potential predictors of coronary access impairment. BACKGROUND: Certain data concerning the feasibility and reproducibility of coronary cannulation after TAVR are lacking. METHODS: RE-ACCESS (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent) was an investigator-driven, single-center, prospective, registry-based study that enrolled consecutive patients undergoing TAVR using all commercially available devices. All patients underwent coronary angiography before and after TAVR. The primary endpoint was the rate of unsuccessful coronary ostia cannulation after TAVR. Secondary endpoints were the identification of factors associated with the inability to selectively cannulate coronary ostia after TAVR. RESULTS: Among 300 patients enrolled in the RE-ACCESS study from December 2018 to January 2020, a total of 23 cases (7.7%) of unsuccessful coronary cannulation after TAVR were documented. This issue occurred in 22 of 23 cases with the use of Evolut R/PRO transcatheter aortic valves (TAVs) (17.9% vs. 0.4%; p < 0.01). In multivariate analysis, the use of Evolut R/PRO TAVs (odds ratio [OR]: 29.6; 95% confidence interval [CI]: 2.6 to 335.0; p < 0.01), the TAV-sinus of Valsalva relation (OR: 1.1 per 1-mm increase; 95% CI: 1.0 to 1.2; p < 0.01), and the mean TAV implantation depth (OR: 1.7 per 1-mm decrease; 95% CI: 1.3 to 2.3; p < 0.01) were found to be independent predictors of unsuccessful coronary cannulation after TAVR. A model combining these factors was demonstrated to predict with very high accuracy the risk for unsuccessful coronary cannulation after TAVR (area under the curve: 0.94; p < 0.01). CONCLUSIONS: Unsuccessful coronary cannulation following TAVR was observed in 7.7% of patients and occurred almost exclusively in those receiving Evolut TAVs. The combination of Evolut TAV, a higher TAV-sinus of Valsalva relation, and implantation depth predicts with high accuracy the risk for unsuccessful coronary cannulation after TAVR. (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent [RE-ACCESS]; NCT04026204).


Subject(s)
Aortic Valve Stenosis , Heart Valve Prosthesis , Transcatheter Aortic Valve Replacement , Aortic Valve/surgery , Aortic Valve Stenosis/surgery , Catheterization , Humans , Prospective Studies , Prosthesis Design , Reproducibility of Results , Risk Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...