Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters











Database
Language
Publication year range
1.
AJR Am J Roentgenol ; 194(4): 964-71, 2010 Apr.
Article in English | MEDLINE | ID: mdl-20308498

ABSTRACT

OBJECTIVE: The purpose of our study was to evaluate whether two-point Dixon MRI using a 2D decomposition technique facilitates metabolite differentiation between lipids and iron in standardized in vitro liver phantoms with in vivo patient validation and allows semiquantitative in vitro assessment of metabolites associated with steatosis, iron overload, and combined disease. MATERIALS AND METHODS: The acrylamide-based phantoms were made to reproduce the T1- and T2-weighted MRI appearances of physiologic hepatic parenchyma and hepatic steatosis-iron overload by the admixture of triglycerides and ferumoxides. Combined disease was simulated using joint admixtures of triglycerides and ferumoxides at various concentrations. For phantom validation, 30 patients were included, of whom 10 had steatosis, 10 had iron overload, and 10 had no liver disease. For MRI an in-phase/opposed-phase T1-weighted sequence with TR/TE(opposed-phase)/TE(in-phase) of 4.19/1.25/2.46 was used. Fat/water series were obtained by Dixon-based algorithms. In-phase and opposed-phase and fat/water ratios were calculated. Statistical cluster analysis assessed ratio pairs of physiologic liver, steatosis, iron overload, and combined disease in 2D metabolite discrimination plots. RESULTS: Statistical assessment proved that metabolite decomposition in phantoms simulating steatosis (1.77|0.22; in-phase/opposed-phase|fat/water ratios), iron overload (0.75|0.21), and healthy control subjects (1.09|0.05) formed three clusters with distinct ratio pairs. Patient validation for hepatic steatosis (3.29|0.51), iron overload (0.56|0.41), and normal control subjects (0.99|0.05) confirmed this clustering (p < 0.001). One-dimensional analysis assessing in vitro combined disease only with in-phase/opposed-phase ratios would have failed to characterize metabolites. The 2D analysis plotting in-phase/opposed-phase and fat/water ratios (2.16|0.59) provided accurate semiquantitative metabolite decomposition (p < 0.001). CONCLUSION: MR Dixon imaging facilitates metabolite decomposition of intrahepatic lipids and iron using in vitro phantoms with in vivo patient validation. The proposed decomposition technique identified distinct in-phase/opposed-phase and fat/water ratios for in vitro steatosis, iron overload, and combined disease.


Subject(s)
Fatty Liver/diagnosis , Iron Overload/diagnosis , Magnetic Resonance Imaging/methods , Adult , Aged , Algorithms , Diagnosis, Differential , Fatty Liver/complications , Female , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Image Processing, Computer-Assisted , Iron Overload/complications , Male , Middle Aged , Phantoms, Imaging , Pilot Projects , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL