Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Thorac Cardiovasc Surg ; 167(3): 1166-1176.e2, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37558202

ABSTRACT

OBJECTIVE: Volatile organic compounds (VOCs) are used in the sterilization and manufacture of medical equipment. These compounds have high vapor pressures with low water solubility and are emitted as gases from solids or liquids. They can be mutagenic, neurotoxic, genotoxic, and/or carcinogenic. Safe limits of exposure are not known for neonates. This study examined determinants of exposure in newborns undergoing cardiac surgery. METHODS: Twenty metabolites of 16 VOCs (eg, xylene, cyanide, acrolein, acrylonitrile, N, N-dimethylformamide, 1,3-butadiene, styrene, and benzene) were measured as metabolites in daily urine samples collected from 10 neonates undergoing cardiac operations (n = 150 samples). Metabolites were quantified using reversed-phase ultra-high performance liquid chromatography and electrospray ionization tandem mass spectrometry. Repeated measures analysis of covariance was performed for each metabolite to examine associations with use of medical devices. RESULTS: At least 3 metabolites were detected in every sample. The median number of metabolites detected in each sample was 14 (range, 3-15). In a model controlling for other factors, the use of extracorporeal membrane oxygenation was associated with significantly (P ≤ .05) greater metabolite levels of acrolein, acrylonitrile, ethylene oxide, propylene oxide, styrene, and ethylbenzene. Patients breathing ambient air had greater levels of metabolites of acrolein, xylene, N,N-dimethylformamide, methyl isocyanate, cyanide, 1,3-butadiene (all P ≤ .05). CONCLUSIONS: Exposure to volatile organic compounds is pervasive in newborns undergoing cardiac surgery. Sources of exposure likely include medical devices and inhalation from the air in the intensive care unit. The contribution of VOC exposure during cardiac surgery in newborns to adverse outcomes warrants further evaluation.


Subject(s)
Acrylonitrile , Air Pollutants , Butadienes , Cardiac Surgical Procedures , Volatile Organic Compounds , Humans , Infant, Newborn , Volatile Organic Compounds/analysis , Air Pollutants/urine , Acrolein/analysis , Xylenes/analysis , Acrylonitrile/analysis , Cardiac Surgical Procedures/adverse effects , Cyanides/analysis , Styrenes/analysis
2.
J Anal Toxicol ; 47(2): 129-135, 2023 Mar 21.
Article in English | MEDLINE | ID: mdl-35766875

ABSTRACT

Liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS-MS) with stable isotope-labeled internal standards (SIL-ISs) is the gold standard for quantitative analysis of drugs and metabolites in complex biological samples. Significant isotopic effects associated with deuterium labeling often cause the deuterated IS to elute at a different retention time from the target analyte, diminishing its capability to compensate for matrix effects. In this study, we systematically compared the analytical performance of deuterated (2H) SIL-IS to non-deuterated (13C and 15N) SIL-ISs for quantifying urinary 2-methylhippuric acid (2MHA) and 4-methylhippuric acid (4MHA), biomarkers of xylenes exposure, with an LC-ESI-MS-MS assay. Analytical method comparison between ISs demonstrated a quantitative bias for urinary 2MHA results, with concentrations generated with 2MHA-[2H7] on average 59.2% lower than concentrations generated with 2MHA-[13C6]. Spike accuracy, measured by quantifying the analyte-spiked urine matrix and comparing the result to the known spike concentration, determined that 2MHA-[2H7] generated negatively biased urinary results of -38.4%, whereas no significant bias was observed for 2MHA-[13C6]. Post-column infusion demonstrated that ion suppression experienced by 2MHA and 2MHA-[13C6] was not equally experienced by 2MHA-[2H7], explaining the negatively biased 2MHA results. The quantitation of urinary 4MHA results between ISs exhibited no significant quantitative bias. These results underscore the importance of the careful selection of ISs for targeted quantitative analysis in complex biological samples.


Subject(s)
Spectrometry, Mass, Electrospray Ionization , Xylenes , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Biomarkers
3.
ACS Omega ; 6(19): 12684-12690, 2021 May 18.
Article in English | MEDLINE | ID: mdl-34056420

ABSTRACT

A method to achieve accurate measurement of unmetabolized volatile organic compounds (VOCs) in urine was developed and characterized. The method incorporates a novel preanalytical approach of adding isotopically labeled internal standard (ISTD) analogues directly to the collection container at the point of collection to compensate for analyte loss to the headspace and the collection container surfaces. Using this approach, 45 toxic VOCs ranging in water solubility and boiling point were evaluated and analyzed by headspace solid-phase microextraction/gas chromatography-mass spectrometry. Results show that urine VOCs could be equally lost to the container headspace as to the container surface suggesting similarity of these two regions as partition phases. Surface adsorption loss was found to trend with compound water solubility. In particular, with no headspace, more nonpolar VOCs experienced substantial losses (e.g., 48% for hexane) in a standard 120 mL urine cup at concentrations in the low- and sub-ppb range. The most polar VOCs evaluated (e.g., tetrahydrofuran) showed no significant loss. Other commonly practiced methods for urine sample collection and analysis such as aliquoting, specimen freezing, and use of surrogate ISTD were found to significantly bias results. With this method, we achieved errors ranging from -8.0 to 4.8% of spiked urine specimens. Paired urine and blood specimens from cigarette smokers were compared to assess this method.

4.
Environ Sci Technol ; 53(4): 2134-2140, 2019 02 19.
Article in English | MEDLINE | ID: mdl-30672285

ABSTRACT

Nitromethane is a known toxicant and suspected human carcinogen. Exposure to nitromethane in a representative sample of the civilian, noninstitutionalized population in the United States ≥12 years old was assessed using 2007-2012 National Health and Nutritional Examination Survey (NHANES) data. Nitromethane was detected in all 8000 human blood samples collected, of which 6730 were used for analyses reported here. Sample-weighted median blood nitromethane was higher among exclusive combusted tobacco users (exclusive smokers; 774 ng/L) than nonusers of tobacco products (625 ng/L). In stratified sample-weighted regression analysis, smoking 0.5 pack of cigarettes per day was associated with a statistically significant increase in blood nitromethane by 150 ng/L, and secondhand smoke exposure (serum cotinine >0.05 ng/mL and <10 ng/mL) was statistically significant with a 31.1 ng/L increase in blood nitromethane. Certain dietary sources were associated with small but statistically significant increases in blood nitromethane. At median consumption levels, blood nitromethane was associated with an increase of 7.55 ng/L (meat/poultry), 9.32 ng/L (grain products), and 14.5 ng/L (vegetables). This is the first assessment of the magnitude and relative source apportionment of nitromethane exposure in the U.S. population.


Subject(s)
Nutrition Surveys , Tobacco Smoke Pollution , Child , Cotinine , Diet , Humans , Methane/analogs & derivatives , Nitroparaffins , Nicotiana , United States
5.
Nicotine Tob Res ; 18(9): 1886-94, 2016 09.
Article in English | MEDLINE | ID: mdl-27113015

ABSTRACT

INTRODUCTION: A significant portion of the increased risk of cancer and respiratory disease from exposure to cigarette smoke is attributed to volatile organic compounds (VOCs). In this study, 21 VOCs were quantified in mainstream cigarette smoke from 50U.S. domestic brand varieties that included high market share brands and 2 Kentucky research cigarettes (3R4F and 1R5F). METHODS: Mainstream smoke was generated under ISO 3308 and Canadian Intense (CI) smoking protocols with linear smoking machines with a gas sampling bag collection followed by solid phase microextraction/gas chromatography/mass spectrometry (SPME/GC/MS) analysis. RESULTS: For both protocols, mainstream smoke VOC amounts among the different brand varieties were strongly correlated between the majority of the analytes. Overall, Pearson correlation (r) ranged from 0.68 to 0.99 for ISO and 0.36 to 0.95 for CI. However, monoaromatic compounds were found to increase disproportionately compared to unsaturated, nitro, and carbonyl compounds under the CI smoking protocol where filter ventilation is blocked. CONCLUSIONS: Overall, machine generated "vapor phase" amounts (µg/cigarette) are primarily attributed to smoking protocol (e.g., blocking of vent holes, puff volume, and puff duration) and filter ventilation. A possible cause for the disproportionate increase in monoaromatic compounds could be increased pyrolysis under low oxygen conditions associated with the CI protocol. IMPLICATIONS: This is the most comprehensive assessment of volatile organic compounds (VOCs) in cigarette smoke to date, encompassing 21 toxic VOCs, 50 different cigarette brand varieties, and 2 different machine smoking protocols (ISO and CI). For most analytes relative proportions remain consistent among U.S. cigarette brand varieties regardless of smoking protocol, however the CI smoking protocol did cause up to a factor of 6 increase in the proportion of monoaromatic compounds. This study serves as a basis to assess VOC exposure as cigarette smoke is a principle source of overall population-level VOC exposure in the United States.


Subject(s)
Air Pollutants/analysis , Nicotiana/chemistry , Smoking , Volatile Organic Compounds/analysis , Gas Chromatography-Mass Spectrometry/methods , Humans , Kentucky , Product Labeling , Reference Standards , Smoke/analysis , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...