Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Hosp Infect ; 69(2): 181-5, 2008 Jun.
Article in English | MEDLINE | ID: mdl-18439714

ABSTRACT

This study aimed to compare the sensitivity and workload requirement of two dermal tolerance assessment methods of hand hygiene products, in order to select a suitable pilot testing method for field tests. An observer-rating method and a self-assessment method were compared in 12 voluntary hospital departments (autumn/winter of 2005-2006). Three test-periods of three weeks were separated by two-week intervals during which the routine products were reintroduced. The observer rating method scored dryness and irritation on four-point scales. In the self-assessment method, the user rated appearance, intactness, moisture content, and sensation on a visual analogue scale which was converted into a 10-point numerical scale. Eleven products (soaps) were tested (223/250 complete reports for observer rating, 131/251 for self-assessment). Two products were significantly less well tolerated than the routine product according to the observers, four products according to the self-assessments. There was no significant difference between the two methods when products were classified according to tolerance (Fisher's test: P=0.491). For the symptom common to both assessment methods (dryness), there is a good correlation between the two methods (Spearman's Rho: P=0.032). The workload was higher for observer rating method (288 h of observer time plus 122 h of prevention team and pharmacist time compared with 15 h of prevention team and pharmacist time for self-assessment). In conclusion, the self-assessment method was considered more suitable for pilot testing, although further time should be allocated for educational measures as the return rate of complete self-assessment forms was poor.


Subject(s)
Hand Disinfection , Soaps/adverse effects , Drug Tolerance , Humans
2.
J Hosp Infect ; 63(3): 281-8, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16650504

ABSTRACT

Tests were performed under working practice conditions to measure the tolerance and acceptability of commercially available hand rubs with proven efficacy. The products were compared with those in current use at the Hospices Civils de Lyon for surgical hand disinfection (Sterillium) and hygienic hand disinfection (Purell) to obtain information for public sector purchases. The 12 test products were Alcogel H, Assanis Pro, Clinogel, Dermalcool, Manugel Plus, Manugel Plus NPC, Manurub Liquid, Manurub Gel, Purell 85, Spitacid, Spitagel and Sterillium Gel. They were tested from mid-November to mid-April over four periods of three weeks, separated by two-week intervals during which the customary product was re-introduced. Participation of hospital wards and theatres was voluntary. Skin dryness and irritation were scored before and after each test period. Acceptability and ease of use were assessed by means of a questionnaire. Among the eight surgical hand rubs, only Manurub Liquid, Manurub Gel and Manugel Plus NPC did not cause significantly more dryness and irritation than Sterillium. For the 10 hygienic hand rubs, differences were noted depending upon the test period. Overall, Assanis Pro, Clinogel, Purell 85 and Sterillium Gel did not cause significantly more dryness and irritation than Purell. However, over the (colder) first three test periods, Assanis Pro and Sterillium Gel caused more irritation and Purell 85 caused more dryness than Purell. Responses to the questionnaires on acceptability indicated that users preferred their customary hand rubs (Sterillium and Purell). As these field tests involving many participants did not identify any superior products, previous purchase orders were renewed.


Subject(s)
Alcohols/adverse effects , Anti-Infective Agents, Local/adverse effects , Attitude of Health Personnel , Disinfectants/adverse effects , Hand Disinfection , Skin/drug effects , Alcohols/therapeutic use , Disinfectants/therapeutic use , Evaluation Studies as Topic , France , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...