Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Language
Publication year range
2.
Rev. esp. quimioter ; 21(3): 184-188, sept. 2008. tab
Article in Spanish | IBECS | ID: ibc-77590

ABSTRACT

Introducción. La resistencia a los antibióticos en el grupode los estreptococos es un problema emergente de especialimportancia en las infecciones graves. El sistema automatizadoBD Phoenix para identificación y antibiograma esun instrumento diagnóstico recientemente disponible quepermite obtener resultados en 12 h.Métodos. Se ha llevado a cabo un estudio comparativoentre el sistema BD Phoenix con paneles SMIC/ID-9 y el métododisco-difusión para la realización de estudios de sensibilidada antibióticos. Se utilizaron 200 aislamientos clínicosde estreptococos: betahemolíticos (n=65), viridans (n=87) yStreptococcus pneumoniae (n=48).Resultados. De forma global, en relación con el métododisco-difusión, hubo un acuerdo entre categorías superioral 96,7% (94,8% en betahemolíticos y 97,9% en viridans).Las tasas de errores menores fueron inferiores al 10% paratodos los antibióticos. El mayor porcentaje de errores gravescorrespondió a eritromicina y clindamicina dentro del grupode los betahemolíticos (14,7 %). El porcentaje global deerrores muy graves fue inferior al 0,5%. Los resultados parapenicilina en estreptococos viridans y S. pneumoniae presentaronun acuerdo entre categorías del 89,7 y 91,7% frentea Etest, respectivamente.Conclusiones. El sistema automatizado BD Phoenix esun instrumento diagnóstico de gran utilidad y efectividadpara el ensayo cuantitativo de la sensibilidad a los antibióticosen el grupo de los estreptococos (AU)


Introduction. Antibiotic resistance is an emergingproblem among streptococcal species, especially for severeinfections. Automated diagnostic systems for antimicrobialsusceptibility testing, such as BD Phoenix, is arecently available instruments that makes it possible toobtain results within 12 h.Methods. Antimicrobial susceptibility testing resultsof the BD Phoenix system were compared to those obtainedfrom Clinical Laboratory Standards Institute (CLSI)disk-diffusion method. Two-hundred different clinicalisolates of streptococci were assayed: beta-hemolytic(n=65), viridans (n=87), S. penumoniae (n=48).Results. Overall, there was categorical agreement greaterthan 96.7% (94.8% for beta-hemolytic and 97.9% for viridansgroup) in relationship to the disk-diffusion method.The minor error rates were less than 10% for all the antibiotics.The greatest percentage of serious errors correspondedto erythromycin and clindamycin within the beta-hemolyticgroup (14.7%). Overall percentage of very serious errors wasless 0.5%. The results for penicillin in viridans streptococciand S. pneumoniae results showed 89.7% and 91.7% of categoricalagreement, respectively, using the Etest as reference.Conclusions. The automated BD Phoenix system is avery useful and effective diagnostic tool for quantitativetesting of sensitivity to antibiotics in the streptococci group (AU)


Subject(s)
Humans , Male , Female , Microbial Sensitivity Tests/classification , Microbial Sensitivity Tests/methods , Microbial Sensitivity Tests/statistics & numerical data , Microbial Sensitivity Tests , Streptococcus , Streptococcus/growth & development , Streptococcus/ultrastructure , Drug Resistance, Microbial/immunology , Drug Resistance, Microbial/physiology , Bacteria , Bacteria/immunology , Bacteria/pathogenicity , Bacteria/ultrastructure
SELECTION OF CITATIONS
SEARCH DETAIL
...