Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
3.
Expert Rev Med Devices ; 10(2): 185-99, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23480088

ABSTRACT

Transcatheter aortic-valve implantation is becoming the standard of care for inoperable patients with severe aortic stenosis and a valid alternative for those at high surgical risk. Since the first percutaneous transcatheter aortic-valve implantation in humans in 2002, over 50,000 transcatheter aortic valves have been implanted in the last decade, with progressive improvement in the available devices. Overall, there are two main families of transcatheter prosthesis: self-expandable and nonself-expandable. The self-expandable devices, for which CoreValve(®) (Medtronic CV Luxembourg S.a.r.l., Luxembourg) represents the prototype, are characterized by a structure composed of shape memory materials, usually nitinol, which acquire its final shape once released. By contrast, the non-self-expandable prostheses, mainly represented by the Edwards(®) valve (Edwards Life Sciences, Inc., CA, USA), require balloon dilatation to reach its final shape. Although several publications have already provided positive data on both technologies, new clinical studies with improved systems are currently being conducted in order to provide more solid data and potentially expand the spectrum of patients who can benefit from this therapy. Thus, the aim of the present paper is to review the salient features of the two most used systems today (third-generation CoreValve and Edwards SAPIEN XT(®)) as well as to provide data on other emerging valves and future perspectives.


Subject(s)
Aortic Valve Stenosis/therapy , Cardiac Catheterization , Heart Valve Prosthesis Implantation/methods , Aged , Aged, 80 and over , Animals , Aortic Valve Stenosis/diagnosis , Bioprosthesis , Cardiac Catheterization/adverse effects , Cardiac Catheterization/instrumentation , Female , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Humans , Male , Patient Selection , Prosthesis Design , Risk Factors , Severity of Illness Index , Treatment Outcome
6.
PLoS Negl Trop Dis ; 4(9)2010 Sep 21.
Article in English | MEDLINE | ID: mdl-20877635

ABSTRACT

INTRODUCTION: Chagas disease remains a major cause of mortality in several countries of Latin America and has become a potential public health problem in non-endemic countries as a result of migration flows. Cardiac involvement represents the main cause of mortality, but its diagnosis is still based on nonspecific criteria with poor sensitivity. Early identification of patients with cardiac involvement is desirable, since early treatment may improve prognosis. This study aimed to assess the role of diastolic dysfunction, abnormal myocardial strain and elevated brain natriuretic peptide (BNP) in the early identification of cardiac involvement in Chagas disease. METHODOLOGY/PRINCIPAL FINDINGS: Fifty-four patients divided into 3 groups--group 1 (undetermined form: positive serology without ECG or 2D-echocardiographic abnormalities; N = 32), group 2 (typical ECG abnormalities of Chagas disease but normal 2D-echocardiography; N = 14), and group 3 (regional wall motion abnormalities, left ventricular [LV] end-diastolic diameter >55 mm or LV ejection fraction <50% on echocardiography; N = 8)--and 44 control subjects were studied. Patients with significant non-cardiac diseases, other heart diseases and previous treatment with benznidazol were excluded. The median age was 37 (20-58) years; 40% were men. BNP levels, longitudinal and radial myocardial strain and LV diastolic dysfunction increased progressively from group 1 to 3 (p for trend <0.01). Abnormal BNP levels (>37 pg/ml) were noted in 0%, 13%, 29% and 63% in controls and groups 1 to 3, respectively. Half of patients in the undetermined form had impaired relaxation patterns, whereas half of patients with ECG abnormalities suggestive of Chagas cardiomyopathy had normal diastolic function. In group 1, BNP levels were statistically higher in patients with diastolic dysfunction as compared to those with normal diastolic function (27 ± 26 vs. 11 ± 8 pg/ml, p = 0.03). CONCLUSION/SIGNIFICANCE: In conclusion, the combination of diastolic function and BNP measurement adds important information that could help to better stratify patients with Chagas disease.


Subject(s)
Chagas Cardiomyopathy/diagnosis , Diastole/physiology , Natriuretic Peptide, Brain/blood , Adult , Biomarkers , Chagas Cardiomyopathy/physiopathology , Early Diagnosis , Echocardiography/methods , Female , Humans , Latin America , Male , Middle Aged , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...