Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Magn Reson Med ; 90(6): 2321-2333, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37526176

ABSTRACT

PURPOSE: CEST MRI has been used to probe changes in cardiac metabolism via assessment of CEST contrast from Cr. However, B1 variation across the myocardium leads to spatially variable Cr CEST contrast in healthy myocardium. METHODS: We developed a spatial-spectral (SPSP) saturation pulsed CEST protocol to compensate for B1 variation. Flip angle maps were used to individually tailor SPSP pulses comprised of a train of one-dimensional spatially selective subpulses selective along the principal B1 gradient dimension. Complete Z-spectra in the hearts of (n = 10) healthy individuals were acquired using conventional Gaussian saturation and SPSP schemes and supported by phantom studies. RESULTS: In simulations, the use of SPSP pulses reduced the average SD of the effective saturation B1 values within the myocardium (n = 10) from 0.12 ± 0.02 µT to 0.05 ± 0.01 µT (p < 0.01) and reduced the average SD of Cr CEST contrast in vivo from 10.0 ± 4.3% to 6.1 ± 3.5% (p < 0.05). Results from the hearts of human subjects showed a significant reduction of CEST contrast distribution at 2 ppm, as well as amplitude, when using SPSP saturation. Corresponding phantom experiments revealed PCr-specific contrast generation at body temperature when SPSP saturation was used but combined PCr and Cr contrast generation when Gaussian saturation was used. CONCLUSION: The use of SPSP saturation pulsed CEST resulted in PCr-specific contrast generation and enabled ratiometric mapping of PCr to total Cr CEST contrast in the human heart at 3T.

2.
Radiology ; 305(2): 329-338, 2022 11.
Article in English | MEDLINE | ID: mdl-35880980

ABSTRACT

Background The relationship between papillary muscle infarction (papMI) and the culprit coronary lesion has not been fully investigated. Delayed enhancement cardiac MRI may detect papMI, yet its accuracy is unknown. Flow-independent dark-blood delayed enhancement (FIDDLE) cardiac MRI has been shown to improve the detection of myocardial infarction adjacent to blood pool. Purpose To assess the diagnostic performance of delayed enhancement and FIDDLE cardiac MRI for the detection of papMI, and to investigate the prevalence of papMI and its relationship to the location of the culprit coronary lesion. Materials and Methods A prospective canine study was used to determine the accuracy of conventional delayed enhancement imaging and FIDDLE imaging for detection of papMI, with pathology-based findings as the reference standard. Participants with first-time myocardial infarction with a clear culprit lesion at coronary angiography were prospectively enrolled at a single hospital from 2015 to 2018 and compared against control participants with low Framingham risk scores. In canines, diagnostic accuracy was calculated for delayed enhancement and FIDDLE imaging. Results In canines (n = 27), FIDDLE imaging was more sensitive (100% [23 of 23] vs 57% [13 of 23], P < .001) and accurate (100% [54 of 54] vs 80% [43 of 54], P = .01) than delayed enhancement imaging for detection of papMI. In 43 participants with myocardial infarction (mean age, 56 years ± 16 [SD]; 28 men), the infarct-related artery was the left anterior descending coronary artery (LAD), left circumflex coronary artery (LCX), and right coronary artery in 47% (20 of 43), 26% (11 of 43), and 28% (12 of 43), respectively. The prevalence of anterior papMI was lower than posterior papMI (37% [16 of 43 participants] vs 44% [19 of 43 participants]) despite more LAD culprit lesions. Culprits leading to papMI were restricted to a smaller "at-risk" portion of the coronary tree for anterior papMI (subtended first diagonal branch of the LAD or first marginal branch of the LCX) compared with posterior (subtended posterior descending artery or third obtuse marginal branch of the LCX). Culprits within these at-risk portions were predictive of papMI at a similar rate (anterior, 83% [15 of 18 participants] vs posterior, 86% [18 of 21 participants]). Conclusion Flow-independent dark-blood delayed enhancement cardiac MRI, unlike conventional delayed enhancement cardiac MRI, was highly accurate in the detection of papillary muscle infarction (papMI). Anterior papMI was less prevalent than posterior papMI, most likely due to culprit lesions being restricted to a smaller portion of the coronary tree rather than because of redundant, dual vascular supply. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Kawel-Boehm and Bremerich in this issue.


Subject(s)
Myocardial Infarction , Papillary Muscles , Male , Humans , Dogs , Animals , Middle Aged , Papillary Muscles/diagnostic imaging , Papillary Muscles/pathology , Prospective Studies , Myocardial Infarction/diagnostic imaging , Coronary Vessels/pathology , Coronary Angiography/adverse effects , Infarction , Magnetic Resonance Imaging/adverse effects
3.
NMR Biomed ; 34(10): e4580, 2021 10.
Article in English | MEDLINE | ID: mdl-34251717

ABSTRACT

Despite clinical use of late gadolinium enhancement (LGE) for two decades, an efficient, robust fat suppression (FS) technique still does not exist for this CMR mainstay. In ischemic and non-ischemic heart disease, differentiating fibrotic tissue from infiltrating and adjacent fat is crucial. Multiple groups have independently developed an FS technique for LGE, double spectral attenuated inversion recovery (DSPAIR), but no comprehensive evaluation was performed. This study aims to fill this gap. DSPAIR uses two SPAIR pulses and one non-selective IR pulse to enable FS LGE, including compatibility with phase sensitive inversion recovery (PSIR). We implemented a magnitude (MAGN) and a PSIR variant and compared them with LGE without FS (CONTROL) and with spectral presaturation with inversion recovery (SPIR) in simulations, phantoms, and patients. Fat magnetization by SPIR, MAGN DSPAIR, and PSIR DSPAIR was simulated as a function of pulse B1 , readout (RO) pulse number, and fat TI . A phantom with fat, fibrosis, and myocardium compartments was imaged using all FS methods and modifying pulse B1 , RO pulse number, and heart rate. Signal was measured in SNR units. Fat, myocardium, and fibrosis SNR and fibrosis-to-fat CNR were obtained. Patient images were acquired with all FS techniques. Fat, myocardium, and fibrosis SNR, fibrosis-to-fat CNR, and image and FS quality were assessed. In the phantom, both DSPAIR variants provided superior FS compared with SPIR, independent of heart rate and RO pulse number. MAGN DSPAIR reduced fat signal by 99% compared with CONTROL, PSIR DSPAIR by 116%, and SPIR by 67% (25 RO pulses). In patients, both DSPAIR variants substantially reduced fat signal (MAGN DSPAIR by 87.1% ± 10.0%, PSIR DSPAIR by 130.5% ± 36.3%), but SPIR did not (35.8% ± 25.5%). FS quality was good to excellent for MAGN and PSIR DSPAIR, and moderate to poor for SPIR. DSPAIR provided highly effective FS across a wide range of parameters. PSIR DSPAIR performed best.


Subject(s)
Gadolinium/chemistry , Lipids/chemistry , Magnetic Resonance Imaging , Arrhythmogenic Right Ventricular Dysplasia/diagnostic imaging , Computer Simulation , Humans , Middle Aged , Phantoms, Imaging , Signal-To-Noise Ratio
4.
JACC Cardiovasc Imaging ; 14(7): 1338-1350, 2021 07.
Article in English | MEDLINE | ID: mdl-33454264

ABSTRACT

OBJECTIVES: The purpose of this study was to assess whether the presence and extent of fibrosis changes over time in patients with nonischemic, dilated cardiomyopathy (DCM) receiving optimal medical therapy and the implications of any such changes on left ventricular ejection fraction (LVEF) and clinical outcomes. BACKGROUND: Myocardial fibrosis on cardiovascular magnetic resonance (CMR) imaging has emerged as important risk marker in patients with DCM. METHODS: In total, 85 patients (age 56 ± 15 years, 45% women) with DCM underwent serial CMR (median interval 1.5 years) for assessment of LVEF and fibrosis. The primary outcome was all-cause mortality; the secondary outcome was a composite of heart failure hospitalization, aborted sudden cardiac death, left ventricular (LV) assist device implantation, or heart transplant. RESULTS: On CMR-1, fibrosis (median 0.0 [interquartile range: 0% to 2.6%]) of LV mass was noted in 34 (40%) patients. On CMR-2, regression of fibrosis was not seen in any patient. Fibrosis findings were stable in 70 (82%) patients. Fibrosis progression (increase >1.8% of LV mass or new fibrosis) was seen in 15 patients (18%); 46% of these patients had no fibrosis on CMR-1. Although fibrosis progression was on aggregate associated with adverse LV remodeling and decreasing LVEF (40 ± 7% to 34 ± 10%; p < 0.01), in 60% of these cases the change in LVEF was minimal (<5%). Fibrosis progression was associated with increased hazards for all-cause mortality (hazard ratio: 3.4 [95% confidence interval: 1.5 to 7.9]; p < 0.01) and heart failure-related complications (hazard ratio: 3.5 [95% confidence interval: 1.5 to 8.1]; p < 0.01) after adjustment for clinical covariates including LVEF. CONCLUSIONS: Once myocardial replacement fibrosis in DCM is present on CMR, it does not regress in size or resolve over time. Progressive fibrosis is often associated with minimal change in LVEF and identifies a high-risk cohort.


Subject(s)
Cardiomyopathy, Dilated , Heart Failure , Adult , Aged , Cardiomyopathy, Dilated/diagnostic imaging , Fibrosis , Heart Failure/diagnostic imaging , Humans , Middle Aged , Predictive Value of Tests , Stroke Volume , Ventricular Function, Left
5.
NMR Biomed ; 33(11): e4396, 2020 11.
Article in English | MEDLINE | ID: mdl-32875674

ABSTRACT

Recently developed dark-blood techniques such as Flow-Independent Dark-blood DeLayed Enhancement (FIDDLE) allow simultaneous visualization of tissue contrast-enhancement and blood-pool suppression. Critical to FIDDLE is the magnetization preparation, which accentuates differences between myocardium and blood-pool. Here, we compared magnetization transfer (MT)-preparation and T2-preparation for use with FIDDLE. Variants of FIDDLE were developed with MT- or T2-preparation modules and tested in 35 patients (11 at 1.5 T, 24 at 3 T). Images were acquired with each FIDDLE variant in an interleaved fashion 10 minutes after gadolinium administration with otherwise identical acquisition parameters. Images were visually and quantitatively assessed for artifacts and differences in right ventricle to left ventricle (RV-to-LV) blood-pool suppression. Bright artifacts, reflecting incomplete blood-pool suppression, were frequently observed in the left atrium with T2-preparation FIDDLE at 1.5 and 3 T (82% and up to 100% of patients, respectively). MT-preparation FIDDLE resulted in fewer patients with artifacts (0% at 1.5 T, 22% at 3 T; P < .01). Left atrial blood-pool signal was significantly more homogeneous with MT-preparation than with T2-preparation at 1.5 and 3 T (P < .001 for all comparisons). Visibly different RV-to-LV blood-pool suppression was observed with T2-preparation in 36% of patients at 1.5 T and up to 94% at 3 T. In these patients, RV blood-pool signal was elevated, reducing the conspicuity of the myocardial-RV blood-pool border. Conversely, there were no visible differences in RV-to-LV blood-pool suppression with MT-preparation. Quantitative assessment of differences in blood-pool suppression and blood-pool artifacts was consistent with visual analyses. We conclude that for dark blood-blood delayed-enhancement imaging of the heart, MT-preparation results in fewer bright blood-pool artifacts and more uniform blood-pool suppression than T2-preparation.


Subject(s)
Blood/diagnostic imaging , Magnetic Resonance Imaging , Adult , Artifacts , Heart Ventricles/diagnostic imaging , Humans , Signal Processing, Computer-Assisted , Signal-To-Noise Ratio
6.
NMR Biomed ; 32(7): e4104, 2019 07.
Article in English | MEDLINE | ID: mdl-31094042

ABSTRACT

Systolic cardiac function is typically preserved in obese adults, potentially masking underlying declines in cardiomyocyte metabolism that may contribute to heart failure. We used chemical exchange saturation transfer (CEST) MRI, a sensitive method for measurement of myocardial creatine, to examine whether myocardial creatine levels correlate with cardiac structure, contractile function, or visceral fat mass in obese adults. In this study, obese (body mass index, BMI > 30, n = 20) and healthy (BMI < 25, n = 11) adults were examined with dual-energy x-ray absorptiometry to quantify fat masses. Cine MRI and myocardial tagging were performed at 1.5 T to measure ventricular structure and global function. CEST imaging with offsets in the range of ±10 parts per million (ppm) were performed in one mid-ventricular slice, where creatine CEST contrast was calculated at 1.8 ppm following field homogeneity correction. Ventricular structure, global function (ejection fraction 69.4 ± 4.3% healthy versus 69.6 ± 9.3% obese, NS), and circumferential strain (-17.0 ± 2.3% healthy versus -16.5 ± 1.5% obese, NS) and strain rate were preserved in obese adults. However, creatine CEST contrast was significantly reduced in obese adults (6.8 ± 1.3% healthy versus 4.1 ± 2.7% obese, p = 0.001). Creatine CEST contrast was inversely correlated with total body fat% (ρ = -0.45, p = 0.011), visceral fat mass (ρ = -0.58, p = 0.001), and septal wall thickness (ρ = -0.44, p = 0.013), but uncorrelated to ventricular function or contractile function. In conclusion, creatine CEST-MRI reveals a strong correlation between heightened body and visceral fat masses and reduced myocardial metabolic function that is independent of ventricular structure and global function in obese adults.


Subject(s)
Creatine/metabolism , Heart Ventricles/pathology , Heart Ventricles/physiopathology , Intra-Abdominal Fat/diagnostic imaging , Intra-Abdominal Fat/pathology , Magnetic Resonance Imaging , Myocardium/metabolism , Obesity/physiopathology , Adult , Female , Humans , Intra-Abdominal Fat/physiopathology , Male , Middle Aged , Myocardial Contraction
7.
Int J Cardiovasc Imaging ; 34(6): 921-929, 2018 Jun.
Article in English | MEDLINE | ID: mdl-29305739

ABSTRACT

To develop a quantitative T1-mapping-based synthetic inversion recovery (IRsynth) approach to calculate the optimal inversion time (TI0) for late gadolinium enhancement (LGE) imaging. Prospectively enrolled patients (n = 130, 58 ± 16 years) underwent cardiac MRI on a 1.5T system including Look-Locker TI-scout (LL), modified LL IR (MOLLI)-based T1-mapping, and LGE acquisitions. Patients were randomized into two groups: LL group (TI-scout followed T1-mapping) or MOLLI group (T1-mapping followed TI-scout). In both groups, the second acquisition was used to determine the TI0 for LGE. IRsynth images were generated from T1-maps between TI = 200-400 ms in 5 ms increments. Image quality was rated on a 3-point scale and the remote/background signal intensity ratio (SIR) was calculated. In the LL group (n = 53), the TI-scout-based TI0 was significantly shorter compared to IRsynth [230 ms (219-242) vs. 280 ms (263-297), P < 0.0001]. The TI0 used for LGE was set 30-40 ms longer [261 ms (247-276), P < 0.0001] than the TI-scout-based TI0, resulting in a TI0 ~ 20 ms shorter than what was obtained by IRsynth (P = 0.0156). In the MOLLI group (n = 63), IRsynth-based TI0 was significantly longer than the TI-scout-based TI0 [298 ms (262-334) vs. 242 ms (217-267), P = 0.0313]. The quality of myocardial nulling was rated higher [2.4 (2.2-2.5) vs. 2.0 (1.8-2.1), P = 0.0042] and the remote/background SIR was found to be more optimal (1.6 [1.1-2.1] vs. 2.6 [1.8-3.3], P = 0.0256) in the MOLLI group. T1-based IRsynth selects TI0 for LGE more accurately than conventional TI-scout imaging. IRsynth improves TI0 selection by providing excellent visualization of the representative image contrast for LGE images, reducing operator dependence in LGE acquisition.


Subject(s)
Heart/diagnostic imaging , Magnetic Resonance Imaging/methods , Myocardium/pathology , Adolescent , Adult , Aged , Aged, 80 and over , Cardiac Imaging Techniques/methods , Cardiac Imaging Techniques/standards , Chronic Disease , Contrast Media , Female , Gadolinium , Humans , Magnetic Resonance Imaging/standards , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Time Factors , Young Adult
8.
JACC Cardiovasc Imaging ; 11(12): 1758-1769, 2018 12.
Article in English | MEDLINE | ID: mdl-29248655

ABSTRACT

OBJECTIVES: This study introduced and validated a novel flow-independent delayed enhancement technique that shows hyperenhanced myocardium while simultaneously suppressing blood-pool signal. BACKGROUND: The diagnosis and assessment of myocardial infarction (MI) is crucial in determining clinical management and prognosis. Although delayed enhancement cardiac magnetic resonance (DE-CMR) is an in vivo reference standard for imaging MI, an important limitation is poor delineation between hyperenhanced myocardium and bright LV cavity blood-pool, which may cause many infarcts to become invisible. METHODS: A canine model with pathology as the reference standard was used for validation (n = 22). Patients with MI and normal controls were studied to ascertain clinical performance (n = 31). RESULTS: In canines, the flow-independent dark-blood delayed enhancement (FIDDLE) technique was superior to conventional DE-CMR for the detection of MI, with higher sensitivity (96% vs. 85%, respectively; p = 0.002) and accuracy (95% vs. 87%, respectively; p = 0.01) and with similar specificity (92% vs, 92%, respectively; p = 1.0). In infarcts that were identified by both techniques, the entire length of the endocardial border between infarcted myocardium and adjacent blood-pool was visualized in 33% for DE-CMR compared with 100% for FIDDLE. There was better agreement for FIDDLE-measured infarct size than for DE-CMR infarct size (95% limits-of-agreement, 2.1% vs. 5.5%, respectively; p < 0.0001). In patients, findings were similar. FIDDLE demonstrated higher accuracy for diagnosis of MI than DE-CMR (100% [95% confidence interval [CI]: 89% to 100%] vs. 84% [95% CI: 66% to 95%], respectively; p = 0.03). CONCLUSIONS: The study introduced and validated a novel CMR technique that improves the discrimination of the border between infarcted myocardium and adjacent blood-pool. This dark-blood technique provides diagnostic performance that is superior to that of the current in vivo reference standard for the imaging diagnosis of MI.


Subject(s)
Magnetic Resonance Imaging , Myocardial Infarction/diagnostic imaging , Myocardium/pathology , Adult , Aged , Animals , Case-Control Studies , Contrast Media/administration & dosage , Coronary Circulation , Disease Models, Animal , Dogs , Humans , Middle Aged , Myocardial Infarction/pathology , Myocardial Infarction/physiopathology , Organometallic Compounds/administration & dosage , Pilot Projects , Predictive Value of Tests , Prognosis , Reproducibility of Results , Tissue Survival , Young Adult
9.
JACC Cardiovasc Imaging ; 10(10 Pt B): 1225-1236, 2017 10.
Article in English | MEDLINE | ID: mdl-29025576

ABSTRACT

OBJECTIVES: This study sought to determine the prevalence, correlates, and impact on cardiac mortality of right ventricular (RV) dysfunction in nonischemic cardiomyopathy. BACKGROUND: Current heart failure guidelines place little emphasis on RV assessment due to limited available data on determinants of RV function, mechanisms leading to its failure, and relation to outcomes. METHODS: We prospectively studied 423 patients with cardiac magnetic resonance (CMR). The pre-specified study endpoint was cardiac mortality. In 100 patients, right heart catheterization was performed as clinically indicated. RESULTS: During a median follow-up time of 6.2 years (interquartile range: 2.9 to 7.6 years), 101 patients (24%) died of cardiac causes. CMR right ventricular ejection fraction (RVEF) was a strong independent predictor of cardiac mortality after adjustment for age, heart failure-functional class, blood pressure, heart rate, serum sodium, serum creatinine, myocardial scar, and left ventricular ejection fraction (LVEF). Patients with the lowest quintile of RVEF had a nearly 5-fold higher cardiac mortality risk than did patients with the highest quintile (hazard ratio: 4.68; 95% confidence interval [CI]: 2.43 to 9.02; p < 0.0001). RVEF was positively correlated with LVEF (r = 0.60; p < 0.0001), and inversely correlated with right atrial pressure (r = -0.32; p = 0.001), pulmonary artery pressure (r = -0.34; p = 0.0005), transpulmonary gradient (r = -0.28; p = 0.006) but not with pulmonary wedge pressure (r = -0.15; p = 0.13). In multivariable logistic regression analysis of CMR, clinical, and hemodynamic data the strongest predictors of right ventricular dysfunction were LVEF (odds ratio [OR]: 0.85; 95% CI: 0.78 to 0.92; p < 0.0001), transpulmonary gradient (OR: 1.20; 95% CI: 1.09 to 1.32; p = 0.0003), and systolic blood pressure (OR: 0.97; 95% CI: 0.94 to 0.99; p = 0.02). CONCLUSIONS: CMR assessment of RVEF provides important prognostic information independent of established risk factors and LVEF in heart failure patients with nonischemic cardiomyopathy. Right ventricular dysfunction is strongly associated with both indices of intrinsic myocardial contractility and increased afterload from pulmonary vascular dysfunction.


Subject(s)
Cardiomyopathies/mortality , Ventricular Dysfunction, Right/mortality , Ventricular Function, Right , Aged , Cardiac Catheterization , Cardiomyopathies/diagnostic imaging , Cardiomyopathies/physiopathology , Cause of Death , Chi-Square Distribution , Female , Humans , Kaplan-Meier Estimate , Logistic Models , Magnetic Resonance Imaging, Cine , Male , Middle Aged , Multivariate Analysis , Myocardial Contraction , North Carolina/epidemiology , Odds Ratio , Prevalence , Prognosis , Proportional Hazards Models , Prospective Studies , Risk Factors , Stroke Volume , Time Factors , Ventricular Dysfunction, Right/diagnostic imaging , Ventricular Dysfunction, Right/physiopathology , Ventricular Function, Left
10.
J Magn Reson Imaging ; 45(5): 1429-1437, 2017 05.
Article in English | MEDLINE | ID: mdl-27690324

ABSTRACT

PURPOSE: To evaluate a new dark-blood late gadolinium enhancement (LGE) technique called "T(Rho) And Magnetization transfer and INvErsion Recovery" (TRAMINER) for the ability to detect myocardial LGE versus standard "bright-blood" inversion recovery (SIR) imaging. MATERIALS AND METHODS: This Institutional Review Board (IRB)-approved, Health Insurance Portability and Accountability Act (HIPAA)-compliant prospective study included 40 patients (62 ± 14 years [mean ± standard deviation (SD)], 29 males) with suspected myocardial infarction (MI) referred for the assessment of myocardial viability. The patients underwent a 1.5T cardiac magnetic resonance imaging (MRI) including postcontrast SIR and TRAMINER acquisitions. Normalized images were evaluated by two readers. Subjective (3-point Likert scale) and objective image qualities were compared using Mann-Whitney U-test and paired t-test, respectively. Interobserver agreement, LGE detection rate, and level of certainty were compared using Cohen's kappa, Wilcoxon-test, and Mann-Whitney U-test, respectively. Results are reported as mean ± SD or mean [95% confidence interval]. RESULTS: Overall, image quality was rated similar between TRAMINER and SIR; however, TRAMINER performed better on a visual assessment of the ability to differentiate LGE from blood (Likert scale: 3.0 [3.0-3.0] vs. 2.0 [1.7-2.2], P < 0.0001). TRAMINER provided significantly higher signal intensity range (69.8 ± 10.2 vs. 9.6 ± 7.6, P < 0.0001) and a 4-fold higher signal intensity ratio (4.2 ± 1.9 vs. 1.1 ± 0.1, P < 0.0001) between LGE and blood signals. TRAMINER detected more patients (19/40 vs. 17/40) and segments (91/649 vs. 79/649) with LGE with higher level of certainty (2.9 [2.8-3.0] vs. 2.7 [2.5-2.8], P = 0.0185). Interobserver agreement was good to excellent for LGE detection. CONCLUSION: TRAMINER provides better contrast between LGE and blood and consequently may have increased ability to discriminate thin subendocardial and papillary muscle enhancement from the blood signal, which can have an indistinct appearance using SIR. LEVEL OF EVIDENCE: 2 J. MAGN. RESON. IMAGING 2017;45:1429-1437.


Subject(s)
Gadolinium/chemistry , Magnetic Resonance Imaging , Myocardial Infarction/diagnostic imaging , Myocardium/pathology , Aged , Contrast Media , Electrocardiography , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Observer Variation , Prospective Studies , Reproducibility of Results
11.
Magn Reson Med ; 78(4): 1442-1451, 2017 10.
Article in English | MEDLINE | ID: mdl-27868238

ABSTRACT

PURPOSE: We demonstrate an improved segmented inversion-recovery sequence that suppresses ghost artifacts arising from tissues with long T1 ( > 1.5 s). THEORY AND METHODS: Long T1 species such as pericardial fluid can create bright ghost artifacts in segmented, inversion-recovery MRI because of oscillations in longitudinal magnetization between segments. A single dummy acquisition at the beginning of the sequence can reduce oscillations; however, its effectiveness in suppressing long T1 artifacts is unknown. In this study, we systematically evaluated several test sequences, including a prototype (saturation post-pulse readout to eliminate spurious signal: SPPRESS) in simulations, phantoms, and patients. RESULTS: SPPRESS reduced artifact signal 90% ± 25% and 74% ± 28% compared with Control and Single-Dummy methods in phantoms. SPPRESS performed well at 1.5 Tesla (T) and 3T, with steady-state free precession (SSFP) and fast low-angle shot (FLASH) readout, with conventional and phase-sensitive reconstruction, and over a range of physiologic heart rates. A review of 100 consecutive clinical cardiac MRI scans revealed large fluid collections (eg, regions with long T1 ) in 14% of patients. In a prospectively enrolled cohort of 16 patients with visible long T1 fluids, SPPRESS appreciably reduced artifacts in all cases compared with Control and Single-Dummy methods. CONCLUSION: We developed and validated a new robust method, SPPRESS, for reducing artifacts due to long T1 species across a wide range of imaging and physiologic conditions. Magn Reson Med 78:1442-1451, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Subject(s)
Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Artifacts , Contrast Media , Gadolinium , Heart/diagnostic imaging , Humans , Phantoms, Imaging
12.
Eur Radiol ; 26(4): 951-8, 2016 Apr.
Article in English | MEDLINE | ID: mdl-26188657

ABSTRACT

OBJECTIVES: Due to the high prevalence of renal failure in transcatheter aortic valve replacement (TAVR) candidates, a non-contrast MR technique is desirable for pre-procedural planning. We sought to evaluate the feasibility of a novel, non-contrast, free-breathing, self-navigated three-dimensional (SN3D) MR sequence for imaging the aorta from its root to the iliofemoral run-off in comparison to non-contrast two-dimensional-balanced steady-state free-precession (2D-bSSFP) imaging. METHODS: SN3D [field of view (FOV), 220-370 mm(3); slice thickness, 1.15 mm; repetition/echo time (TR/TE), 3.1/1.5 ms; and flip angle, 115°] and 2D-bSSFP acquisitions (FOV, 340 mm; slice thickness, 6 mm; TR/TE, 2.3/1.1 ms; flip angle, 77°) were performed in 10 healthy subjects (all male; mean age, 30.3 ± 4.3 yrs) using a 1.5-T MRI system. Aortic root measurements and qualitative image ratings (four-point Likert-scale) were compared. RESULTS: The mean effective aortic annulus diameter was similar for 2D-bSSFP and SN3D (26.7 ± 0.7 vs. 26.1 ± 0.9 mm, p = 0.23). The mean image quality of 2D-bSSFP (4; IQR 3-4) was rated slightly higher (p = 0.03) than SN3D (3; IQR 2-4). The mean total acquisition time for SN3D imaging was 12.8 ± 2.4 min. CONCLUSIONS: Our results suggest that a novel SN3D sequence allows rapid, free-breathing assessment of the aortic root and the aortoiliofemoral system without administration of contrast medium. KEY POINTS: • The prevalence of renal failure is high among TAVR candidates. • Non-contrast 3D MR angiography allows for TAVR procedure planning. • The self-navigated sequence provides a significantly reduced scanning time.


Subject(s)
Aortic Valve Stenosis/pathology , Aortic Valve Stenosis/surgery , Transcatheter Aortic Valve Replacement/methods , Adult , Aortic Valve/pathology , Aortic Valve/surgery , Contrast Media , Feasibility Studies , Healthy Volunteers , Humans , Imaging, Three-Dimensional , Magnetic Resonance Angiography/methods , Magnetic Resonance Imaging, Interventional/methods , Male , Prospective Studies
13.
Circ Res ; 117(3): 254-65, 2015 Jul 17.
Article in English | MEDLINE | ID: mdl-25972514

ABSTRACT

RATIONALE: After acute myocardial infarction (MI), delineating the area-at-risk (AAR) is crucial for measuring how much, if any, ischemic myocardium has been salvaged. T2-weighted MRI is promoted as an excellent method to delineate the AAR. However, the evidence supporting the validity of this method to measure the AAR is indirect, and it has never been validated with direct anatomic measurements. OBJECTIVE: To determine whether T2-weighted MRI delineates the AAR. METHODS AND RESULTS: Twenty-one canines and 24 patients with acute MI were studied. We compared bright-blood and black-blood T2-weighted MRI with images of the AAR and MI by histopathology in canines and with MI by in vivo delayed-enhancement MRI in canines and patients. Abnormal regions on MRI and pathology were compared by (a) quantitative measurement of the transmural-extent of the abnormality and (b) picture matching of contours. We found no relationship between the transmural-extent of T2-hyperintense regions and that of the AAR (bright-blood-T2: r=0.06, P=0.69; black-blood-T2: r=0.01, P=0.97). Instead, there was a strong correlation with that of infarction (bright-blood-T2: r=0.94, P<0.0001; black-blood-T2: r=0.95, P<0.0001). Additionally, contour analysis demonstrated a fingerprint match of T2-hyperintense regions with the intricate contour of infarcted regions by delayed-enhancement MRI. Similarly, in patients there was a close correspondence between contours of T2-hyperintense and infarcted regions, and the transmural-extent of these regions were highly correlated (bright-blood-T2: r=0.82, P<0.0001; black-blood-T2: r=0.83, P<0.0001). CONCLUSION: T2-weighted MRI does not depict the AAR. Accordingly, T2-weighted MRI should not be used to measure myocardial salvage, either to inform patient management decisions or to evaluate novel therapies for acute MI.


Subject(s)
Magnetic Resonance Imaging/methods , Myocardial Infarction/pathology , Myocardium/pathology , Adult , Aged , Animals , Coronary Circulation , Diagnosis, Differential , Dogs , Edema/pathology , Endpoint Determination , Female , Fluorescent Dyes , Heart/physiopathology , Humans , Male , Microspheres , Middle Aged , Myocardial Infarction/blood , Myocardial Infarction/chemically induced , Myocardial Infarction/physiopathology , Organ Size , Organometallic Compounds , Prospective Studies , Risk , Troponin T/blood
14.
Magn Reson Med ; 70(5): 1360-8, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23213005

ABSTRACT

A versatile method for generating T2 -weighting is a T2 -preparation module, which has been used successfully for cardiac imaging at 1.5T. Although it has been applied at 3T, higher fields (B0 ≥ 3T) can degrade B0 and B1 homogeneity and result in nonuniform magnetization preparation. For cardiac imaging, blood flow and cardiac motion may further impair magnetization preparation. In this study, a novel T2 -preparation module containing multiple adiabatic B1 -insensitive refocusing pulses is introduced and compared with three previously described modules [(a) composite MLEV4, (b) modified BIR-4 (mBIR-4), and (c) Silver-Hoult-pair]. In the static phantom, the proposed module provided similar or better B0 and B1 insensitivity than the other modules. In human subjects (n = 21), quantitative measurement of image signal coefficient of variation, reflecting overall image inhomogeneity, was lower for the proposed module (0.10) than for MLEV4 (0.15, P < 0.0001), mBIR-4 (0.27, P < 0.0001), and Silver-Hoult-pair (0.14, P = 0.001) modules. Similarly, qualitative analysis revealed that the proposed module had the best image quality scores and ranking (both, P < 0.0001). In conclusion, we present a new T2 -preparation module, which is shown to be robust for cardiac imaging at 3T in comparison with existing methods.


Subject(s)
Algorithms , Artifacts , Coronary Vessels/anatomy & histology , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Angiography/methods , Magnetic Resonance Imaging, Cine/methods , Blood Flow Velocity , Coronary Vessels/physiology , Female , Humans , Male , Middle Aged , Movement/physiology , Reproducibility of Results , Sensitivity and Specificity
15.
Acta Cardiol ; 66(3): 349-57, 2011 Jun.
Article in English | MEDLINE | ID: mdl-21744705

ABSTRACT

OBJECTIVE: Papillary muscles and trabeculae for ventricular function analysis are known to significantly contribute to accurate volume and mass measurements. Fast imaging techniques such as three-dimensional steady-state free precession (3D SSFP) are increasingly being used to speed up imaging time, but sacrifice spatial resolution. It is unknown whether 3D SSFP, despite its reduced spatial resolution, allows for exact delineation of papillary muscles and trabeculations. We therefore compared 3D SSFP ventricular function measurements to those measured from standard multi-breath hold two-dimensional steady-state free precession cine images (standard 2D SSFP). METHODS AND RESULTS: 14 healthy subjects and 14 patients with impaired left ventricularfunction underwent 1.5 Tesla cine imaging. A stack of short axis images covering the left ventricle was acquired with 2D SSFP and 3D SSFP. Left ventricular volumes, ejection fraction, and mass were determined. Analysis was performed by substracting papillary muscles and trabeculae from left ventricular volumes. In addition, reproducibility was assessed. EDV, ESV, EF, and mass were not significantly different between 2D SSFP and 3D SSFP (mean difference healthy subjects: -0.06 +/- 3.2 ml, 0.54 +/- 2.2 ml, -0.45 +/- 1.8%, and 1.13 +/- 0.8 g, respectively; patients: 1.36 +/- 2.8 ml, -0.15 3.5 ml, 0.86 +/- 2.5%, and 0.91 +/- 0.9 g, respectively; P > or = 0.095). Intra- and interobserver variability was not different for 2D SSFP (P > or = 0.64 and P > or = 0.397) and 3D SSFP (P > or = 0.53 and P > or = 0.47). CONCLUSIONS: Differences in volumes, EF, and mass measurements between 3D SSFP and standard 2D SSFP are very small, and not statistically significant. 3D SSFP may be used for accurate ventricular function assessment when papillary muscles and trabeculations are to be taken into account.


Subject(s)
Magnetic Resonance Imaging, Cine/methods , Papillary Muscles/physiopathology , Ventricular Dysfunction, Left/physiopathology , Ventricular Function, Left/physiology , Adult , Aged , Diastole/physiology , Female , Heart/physiopathology , Humans , Imaging, Three-Dimensional , Middle Aged , Systole/physiology
16.
AJR Am J Roentgenol ; 196(2): 339-48, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21257885

ABSTRACT

OBJECTIVE: Delayed enhancement MRI using fast segmented k-space inversion recovery (IR) gradient-echo imaging is a well established "bright-blood" technique for identifying myocardial infarction and is used as the reference standard sequence in this study. The purpose of this study was to validate a recently developed dark blood-pool delayed enhancement technique in a porcine animal model, evaluate its performance in human patients, and quantify its performance compared with the reference standard in both. SUBJECTS AND METHODS: In an animal study, the reference standard and dark blood-pool delayed enhancement were assessed in three pigs with induced myocardial infarction. In a human study, 26 patients, 31-81 years old (19 men and seven women), with a known history of myocardial infarction were imaged using the reference standard and dark blood-pool delayed enhancement. Contrast-to-noise ratio (CNR), signal intensity ratio, signal-to-noise ratio (SNR), and qualitative scores of hyperenhancement were recorded. Measurements were compared using paired samples t test and Wilcoxon's signed rank test. RESULTS: In the animal study, the mean CNR of infarct to blood pool was 11 times higher for dark blood-pool delayed enhancement than for the reference standard. The mean SNR was 4.4 times higher for the reference standard. In the human study, the mean CNR and signal intensity ratio of hyperenhancing myocardium to the blood pool were 1.9 (p = 0.04) and 5.5 (p < 0.01) times higher, respectively, for dark blood-pool delayed enhancement compared with reference standard. The mean CNR and signal intensity ratio of hyperenhancing myocardium to normal myocardium and SNR were 2.8 (p < 0.01), 1.3 (p = 0.07), and 2.8 (p < 0.01) higher, respectively, for the reference standard. Qualitative analysis identified seven extra segments with grade 1 scars using dark blood-pool delayed enhancement (p < 0.01). CONCLUSION: Dark blood-pool delayed enhancement is complementary to the reference standard. It can detect more subendocardial foci of hyperenhancement, thus potentially identifying more infarcts and changing patient management.


Subject(s)
Endocardium/pathology , Image Enhancement/methods , Magnetic Resonance Imaging/methods , Myocardial Infarction/diagnosis , Myocardium/pathology , Adult , Aged , Aged, 80 and over , Animals , Female , Humans , Male , Middle Aged , Swine
17.
Radiology ; 247(1): 106-14, 2008 Apr.
Article in English | MEDLINE | ID: mdl-18292473

ABSTRACT

PURPOSE: To prospectively compare in canines the diagnostic accuracy for myocardial infarction (MI) of standard delayed-enhancement (DE) magnetic resonance (MR) imaging versus that of subsecond DE MR imaging with and without breath holding and/or cardiac arrhythmia, with histologic findings or absence of surgical creation of MI as the reference standard. MATERIALS AND METHODS: This study was approved by the Institutional Animal Care and Use Committee; 21 canines were imaged with one standard and two subsecond DE MR techniques in four conditions: condition 1, breath holding and steady gating; 2, non-breath holding and steady gating; 3, breath holding and irregular heart rhythm; and 4, non-breath holding and irregular heart rhythm. Images were randomized and scored for diagnostic accuracy, image quality, and observer confidence. Sensitivity, specificity, and diagnostic accuracy for MI detection were calculated for each technique and clinical condition separately. The chi(2), paired t, and McNemar tests were used for comparisons. RESULTS: Fifteen dogs had MIs. Among conditions 2-4, differences were not significant (P > .05); data were pooled and referred to as group B. Condition 1 was group A. Accuracy, image quality, and observer confidence, respectively, for standard DE MR imaging were 96%, 3.7 +/- 0.8, and 2.7 +/- 0.6 in group A but only 74%, 2.4 +/- 0.8, and 1.8 +/- 0.7 in group B (P < or = .004 for each). Corresponding scores for subsecond techniques were unaffected by respiratory motion and/or arrhythmia. Subsecond techniques had higher accuracy (82% and 86% vs 74%), better image quality (3.9 +/- 0.7 and 3.2 +/- 0.8 vs 2.4 +/- 0.8), and greater confidence (2.4 +/- 0.7 and 2.1 +/- 0.7 vs 1.8 +/- 0.7) (P < or = .0002 for each) than standard DE MR imaging. In group A, standard performed better than subsecond DE MR imaging. CONCLUSION: Standard DE MR imaging is appropriate for MI detection with breath holding and regular heart rhythm, while subsecond techniques are appropriate with an irregular heart rhythm and when breath holding is not possible.


Subject(s)
Arrhythmias, Cardiac/complications , Magnetic Resonance Imaging , Myocardial Infarction/diagnosis , Respiration , Animals , Dogs , Magnetic Resonance Imaging/methods , Movement , Myocardial Infarction/physiopathology , Myocardium/pathology , Radiographic Image Enhancement , Sensitivity and Specificity
18.
Magn Reson Med ; 58(1): 82-91, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17659624

ABSTRACT

To extend the signal longevity of magnetically excited spins in flowing fluids while in a state of global coherent free precession (GCFP), a refocusing radiofrequency (RF) pulse and bipolar gradient waveforms were combined with the GCFP sequence. The data demonstrate that RF refocusing in the presence of flowing blood is possible, but the improvement in signal amplitude depends on the static magnetic field homogeneity along the direction of motion and the displacement of the spins between the excitation and the RF refocusing pulse, as well as displacement during subsequent RF refocusing pulses. The least amount of phase dispersion and thus the longest lasting signal is obtained with the shortest echo spacing where only one line of data is recorded between two RF refocusing pulses. This approach was successfully used in a phantom and in vivo to image fast and slow blood flow. Depending on the experimental conditions, signal persistence is improved significantly compared to playing the same sequence without RF refocusing, but the improvement is limited by the product of blood flow velocity and the time between RF refocusing pulses.


Subject(s)
Magnetic Resonance Angiography/methods , Animals , Dogs , Phantoms, Imaging
19.
Expert Rev Cardiovasc Ther ; 5(2): 307-21, 2007 Mar.
Article in English | MEDLINE | ID: mdl-17338674

ABSTRACT

Cardiovascular magnetic resonance (CMR) imaging is a comprehensive clinical tool for assessing a large variety of cardiovascular diseases. Using the clinical service of the Duke Cardiovascular Magnetic Resonance Center as an example, we describe how to perform image contractile function, myocardial perfusion at stress and rest, myocardial viability, cardiovascular morphology, vascular anatomy and blood flow tests. The emergence of successful dedicated CMR services presents an opportunity to optimize patient throughput by streamlining the user interface of CMR scanners, standardizing the viewing format and reporting software, and customizing training programs to focus on the standardized CMR approaches. Accordingly, we discuss potential pathways to create these standards. Finally, we discuss several promising new CMR techniques we expect will complement existing clinical procedures.


Subject(s)
Cardiovascular Diseases/diagnosis , Magnetic Resonance Angiography/standards , Magnetic Resonance Imaging, Cine/standards , Radiographic Image Enhancement , Exercise Test/methods , Female , Forecasting , Humans , Magnetic Resonance Angiography/trends , Magnetic Resonance Imaging/standards , Magnetic Resonance Imaging/trends , Magnetic Resonance Imaging, Cine/trends , Male , Sensitivity and Specificity
20.
Circulation ; 115(2): 236-44, 2007 Jan 16.
Article in English | MEDLINE | ID: mdl-17200443

ABSTRACT

BACKGROUND: An ultrafast, delayed contrast-enhancement cardiovascular magnetic resonance technique that can acquire subsecond, "snapshot" images during free breathing (subsecond) is becoming widely available. This technique provides myocardial infarction (MI) imaging with complete left ventricular coverage in < 30 seconds. However, the accuracy of this technique is unknown. METHODS AND RESULTS: We prospectively compared subsecond imaging with routine breath-hold delayed contrast-enhancement cardiovascular magnetic resonance (standard) in consecutive patients. Two cohorts with unambiguous standards of truth were prespecified: (1) patients with documented prior MI (n=135) and (2) patients without MI and with low likelihood of coronary disease (lowest Framingham risk category; n=103). Scans were scored masked to identity and clinical information. Sensitivity, specificity, and accuracy of subsecond imaging for MI diagnosis were 87%, 96%, and 91%, respectively. Compared with the standard technique (98%, 100%, 99%), the subsecond technique had modestly reduced sensitivity (P=0.0001), but specificity was excellent. Missed infarcts were generally small or subendocardial (87%). Overall, regional transmural extent of infarction scores were highly concordant (2083/2294; 91%); however, 51 of 337 regions (15%) considered predominantly infarcted (> 50% transmural extent of infarction) by the standard technique were considered viable (< or = 25% transmural extent of infarction) by the subsecond technique. Quantitative analysis demonstrated moderately reduced contrast-to-noise ratios for subsecond imaging between infarct and remote myocardium (12.0+/-7.2 versus 20.1+/-6.6; P<0.0001) and infarct and left ventricular cavity (-2.5+/-2.7 versus 3.6+/-3.7; P<0.0001). CONCLUSIONS: MI can be rapidly detected by subsecond delayed contrast-enhancement cardiovascular magnetic resonance during free breathing with high accuracy. This technique could be considered the preferred approach in patients who are more acutely ill or unable to hold their breath. However, compared with standard imaging, sensitivity is mildly reduced, and the transmural extent of infarction may be underestimated.


Subject(s)
Magnetic Resonance Imaging/methods , Myocardial Infarction/diagnosis , Respiration , Adult , Aged , Cohort Studies , Contrast Media , Female , Humans , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Prospective Studies , Radiography , Respiratory Mechanics/physiology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...