Results 1 - 20 de 344
Filter
1.
Article in English | MEDLINE | ID: mdl-38842971

ABSTRACT

BACKGROUND: There is limited information on the mode of arrhythmia initiation in idiopathic ventricular fibrillation (IVF). A non-pause-dependent mechanism has been suggested to be the rule. OBJECTIVES: The aim of this study was to assess the mode and characteristics of initiation of polymorphic ventricular tachycardia (PVT) in patients with short or long-coupled PVT/IVF included in THESIS (THerapy Efficacy in Short or long-coupled idiopathic ventricular fibrillation: an International Survey), a multicenter study involving 287 IVF patients treated with drugs or radiofrequency ablation. METHODS: We reviewed the initiation of 410 episodes of ≥1 PVT triplet in 180 patients (58.3% females; age 39.6 ± 13.6 years) with IVF. The incidence of pause-dependency arrhythmia initiation (prolongation by >20 ms of the preceding cycle length) was assessed. RESULTS: Most arrhythmias (n = 295; 72%) occurred during baseline supraventricular rhythm without ambient premature ventricular complexes (PVCs), whereas 106 (25.9%) occurred during baseline rhythm including PVCs. Nine (2.2%) arrhythmias occurred during atrial/ventricular pacing and were excluded from further analysis. Mode of PVT initiation was pause-dependent in 45 (15.6%) and 64 (60.4%) of instances in the first and second settings, respectively, for a total of 109 of 401 (27.2%). More than one type of pause-dependent and/or non-pause-dependent initiation (mean: 2.6) occurred in 94.4% of patients with ≥4 events. Coupling intervals of initiating PVCs were <350 ms, 350-500 ms, and >500 ms in 76.6%, 20.72%, and 2.7% of arrhythmia initiations, respectively. CONCLUSIONS: Pause-dependent initiation occurred in more than a quarter of arrhythmic episodes in IVF patients. PVCs having long (between 350 and 500 ms) and very long (>500 ms) coupling intervals were observed at the initiation of nearly a quarter of PVT episodes.

2.
Heart Rhythm O2 ; 5(5): 257-265, 2024 May.
Article in English | MEDLINE | ID: mdl-38840763

ABSTRACT

Background: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology. Its potential value for repeat procedures after unsuccessful thermal ablation for atrial fibrillation has not been assessed. Objective: The purpose of this study was to summarize our initial experience with patients undergoing repeat procedures using PFA. Methods: Consecutive patients with arrhythmia recurrences after a prior thermal ablation undergoing a repeat procedure using a multipolar PFA catheter from May 2021 and December 2022 were included. After 3-dimensional electroanatomic mapping, reconnected pulmonary veins (PVs) were reisolated and veins with only ostial isolation wither ablated to widen antral PV isolation. Posterior wall ablation was performed if all PVs were durably isolated or in case of low-voltage areas on the posterior wall at the discretion of the operator. Patients underwent follow-up with 7-day Holter electrocardiography after 3, 6, and 12 months. Results: A total of 186 patients undergoing a repeat procedure using PFA were included. The median number of previous ablations was 1 (range 1-6). The prior ablation modality was radiofrequency in 129 patients (69.4%), cryoballoon in 51 (27.4%), and epicardial ablation in 6 (3.2%). At the beginning of the procedure, 258 of 744 PVs (35%) showed reconnections. Additional antral ablations were applied in 236 of 486 still isolated veins (49%). Posterior wall ablation was added in 125 patients (67%). Major complications occurred in 1 patient (transient ischemic attack 0.5%). Freedom from arrhythmia recurrence in Kaplan-Meier-analysis was 78% after 6 months and 54% after 12 months. Conclusion: PFA is a versatile and safe option for repeat procedures after failed prior thermal ablation.

3.
Article in English | MEDLINE | ID: mdl-38752963

ABSTRACT

BACKGROUND: Pulmonary vein isolation is an effective treatment for atrial fibrillation (AF). Cryoballoon ablation using the Arctic Front cryoballoon (Medtronic) was found to be superior to antiarrhythmic drug treatment. Recently, a novel cryoballoon system was introduced (PolarX, Boston Scientific). OBJECTIVES: The purpose of this study was to compare the efficacy and safety of the 2 cryoballoons in a randomized controlled trial. METHODS: Patients with symptomatic paroxysmal AF were enrolled in 2 centers and randomized 1:1 to pulmonary vein isolation using the PolarX or the Arctic Front cryoballoon. All patients received an implantable cardiac monitor. The primary endpoint was first recurrence of atrial tachyarrhythmia (AF, atrial flutter, or atrial tachycardia [AT]) between days 91 and 365. Procedural safety was assessed by a composite of tamponade, phrenic nerve palsy lasting >24 hours, vascular complications, stroke/transient ischemic attack, atrioesophageal fistula or death up to 30 days. RESULTS: A total of 201 patients were enrolled. At 1 year, recurrence of atrial tachyarrhythmia had occurred in 41 of 99 patients (41.6%) assigned to the PolarX group and in 48 of 102 patients (47.1%) assigned to the Arctic Front group (HR: 0.85 [95% CI: 0.56-1.30]; P = 0.03 for noninferiority; P = 0.46 for superiority). The safety endpoint occurred in 5 patients (5%) in the PolarX group (n = 5 phrenic nerve palsies lasting >24 hours), whereas no safety endpoints occurred in the Arctic Front group (P = 0.03). CONCLUSIONS: In this randomized controlled trial using implantable cardiac monitors for continuous rhythm monitoring, the novel PolarX cryoballoon was noninferior compared with the Arctic Front cryoballoon regarding efficacy. However, the PolarX balloon resulted in significantly more phrenic nerve palsies. (Comparison of PolarX and the Arctic Front Cryoballoons for PVI in Patients With Symptomatic Paroxysmal AF [COMPARE-CRYO]; NCT04704986).

4.
Article in English | MEDLINE | ID: mdl-38819347

ABSTRACT

BACKGROUND: Catheter ablation for atrial fibrillation (AF) including pulmonary vein isolation and possibly further substrate ablation is the most common electrophysiological procedure. Severe complications are uncommon, but their detailed assessment in a large worldwide cohort is lacking. OBJECTIVES: The aim of this study was to determine the incidence of periprocedural severe complications and to provide a detailed characterization of the diagnostic evaluation and management of these complications in patients undergoing AF ablation. METHODS: Individual patient data were collected from 23 centers worldwide. Limited data were collected for all patients who underwent catheter ablation, and an expanded series of data points were collected for patients who experienced severe complications during periprocedural follow-up. Incidence, predictors, patient characteristics, management details, and overall outcomes of patients who experienced ablation-related complications were investigated. RESULTS: Data were collected from 23 participating centers at which 33,879 procedures were performed (median age 63 years, 30% women, 71% radiofrequency ablations). The incidence of severe complications (n = 271) was low (tamponade 6.8‰, stroke 0.97‰, cardiac arrest 0.41‰, esophageal fistula 0.21‰, and death 0.21‰). Age, female sex, a dilated left atrium, procedure duration, and the use of radiofrequency energy were independently associated with the composite endpoint of all severe complications. Among patients experiencing tamponade, 13% required cardiac surgery. Ninety-three percent of patients with complications were discharged directly home after a median length of stay of 5 days (Q1-Q3: 3-7 days). CONCLUSIONS: This large worldwide collaborative study highlighted that tamponade, stroke, cardiac arrest, esophageal fistula, and death are rare after AF ablation. Older age, female sex, procedure duration, a dilated left atrium, and the use of radiofrequency energy were associated with severe complications in this multinational cohort. One in 8 patients with tamponade required cardiac surgery.

6.
Heart Rhythm ; 2024 May 16.
Article in English | MEDLINE | ID: mdl-38762133

ABSTRACT

BACKGROUND: Stroke remains one of the most serious complications in atrial fibrillation (AF) patients and has been linked to disturbances of the autonomic nervous system. OBJECTIVE: We hypothesized that impaired cardiac autonomic function might be associated with an enhanced stroke risk in AF patients. METHODS: We enrolled 1922 AF patients who were either in sinus rhythm (SR-group, n=1121) or AF (AF-group, n=801) on a 5-minute resting ECG recording. HRV triangular index (HRVI), standard deviation of normal-to-normal intervals, root mean square root of successive differences of normal-to-normal intervals, mean heart rate, 5-min total power and power in the high frequency, low frequency and very low frequency range were calculated. We constructed Cox regression models to examine the association of HRV parameters with the composite endpoint of stroke or systemic embolism. RESULTS: Mean age was 71±8 years in the SR group and 75±8 in the AF group. 37 patients in the SR group (3.4%) and 60 patients in the AF group (8.0%) experienced a stroke or systemic embolism during a follow-up time of 5 years. In patients with SR, HRVI <15 was the strongest HRV parameter to be associated with stroke or systemic embolism (hazard ratio 3.04; 95% confidence interval 1.3-7.0; p=0.009) after adjustment for multiple confounders. In the AF group, we found no HRV parameter to be associated with the composite endpoint. CONCLUSION: HRVI measured during SR on a single 5-minute ECG recording is independently associated with stroke or systemic embolism in AF patients. HRV analysis in SR may help to improve risk stratification in AF patients.

7.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38587017

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Latin America , Treatment Outcome , Catheters , Asia , Catheter Ablation/adverse effects , Catheter Ablation/methods
9.
Europace ; 26(4)2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38597211

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is increasingly performed in patients with atrial fibrillation (AF). Both AF phenotype and left atrial (LA) volume have been shown to influence ablation outcome. The inter-relationship of the two is incompletely understood. We aimed to investigate the impact of AF phenotype vs. LA volume on outcome after PVI. METHODS AND RESULTS: In a retrospective analysis of a prospective registry of patients undergoing a first PVI, the association of AF phenotype and LA volume index (LAVI) was assessed as well as their impact on AF recurrence during follow-up. Overall, 476 patients were enrolled (median age 63 years, 29% females, 65.8% paroxysmal AF). Obesity, hypertension, chronic kidney disease, and heart failure were all significantly more frequent in persistent AF. After 1 year, single-procedure, freedom from arrhythmia recurrence was 61.5%. Patients with paroxysmal AF had better outcomes compared with patients with persistent AF (65.6 vs. 52.7%, P = 0.003), as had patients with no/mild vs. moderate/severe LA dilation (LAVI <42 mL/m2 67.1% vs. LAVI ≥42 mL/m2 53%, P < 0.001). The combination of both parameters refined prediction of 1-year recurrence (P < 0.001). After adjustment for additional clinical risk factors in multivariable Cox proportional hazard analysis, both AF phenotype and LAVI ≥42 mL/m2 contributed significantly towards the prediction of 1-year recurrence. CONCLUSION: Atrial fibrillation phenotype and LA volume are independent predictors of outcome after PVI. Persistent AF with no/mild LA dilation has a similar risk of recurrence as paroxysmal AF with a moderate/severe LA dilation and should be given similar priority for ablation.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Female , Humans , Middle Aged , Male , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Atrial Fibrillation/etiology , Pulmonary Veins/surgery , Retrospective Studies , Treatment Outcome , Heart Atria/diagnostic imaging , Heart Atria/surgery , Phenotype , Recurrence , Catheter Ablation/adverse effects , Catheter Ablation/methods
10.
Article in English | MEDLINE | ID: mdl-38639700

ABSTRACT

BACKGROUND: Recurrence of paroxysmal atrial fibrillation (AF) following pulmonary vein isolation (PVI) is presumably caused by pulmonary vein (PV) reconnections. However, there is little data available on the durability of PVI and incidence of arrhythmia recurrence in patients with persistent AF. OBJECTIVES: To evaluate the lesion durability by means of an a priori planned remapping procedure in patients with persistent AF undergoing CLOSE-guided PVI. METHODS: In a prospective study, we included patients with symptomatic, persistent AF undergoing CLOSE-guided radiofrequency ablation. Irrespective of AF recurrence, a redo procedure was mandated 6 months following the index procedure to evaluate PV reconnections. The outcome of AF ablation was based on clinical recurrence and 7-day Holter electrocardiogram 3 and 6 months after the index procedure and 3, 6, and 12 months after the redo procedure. RESULTS: Of 30 patients included, 26 (81% men; median age 68 years) underwent the planned remapping study a median of 6 months after the index procedure, whereas 4 patients without recurrence refused a repeat procedure. In total, 78 of 102 (76%) PVs showed durable isolation and 15 patients (58%) presented complete isolation of all PVs. Beyond the blanking period, 6 of 26 patients (23%) had arrhythmia recurrence before the redo procedure. Recurrence had occurred in 33% of patients with complete isolation of all veins and in 9% of patients with PV reconnections (P = 0.197). After re-PVI in patients with PV reconnections and additional ablation in patients with recurrence but durable PVI, 17 of 26 patients (65%) were free of arrhythmia after 12 months. CONCLUSIONS: In patients with persistent AF, CLOSE-guided PVI resulted in durable rate of PVI on a per-vein and per-patient level of 76% and 58%, respectively. Arrhythmia recurrence was numerically higher in patients with durable PVI compared with patients without.

11.
Article in English | MEDLINE | ID: mdl-38630571

ABSTRACT

The first commercial dual-chamber leadless pacemaker (LLPM) was introduced recently. The system combines two separate implants situated in the right atrium and the right ventricle of the heart. Implant synchronization is accomplished with conductive intracardiac communication (CIC) using the myocardium and blood as transmission channel. Successful implant synchronization of this dual-chamber LLPM has been demonstrated. However, the continuously active synchronization transceivers, consuming about 800 nA, cause a 25-45% reduction in the projected device longevity. This work proposes an alternative strategy for power-optimized LLPM synchronization, which is based on synchronous duty-cycling of the transceivers and direct-digital CIC (DD-CIC). In line with this strategy, a novel low-power DD-CIC receiver for short-packet communication based on Manchester-encoded data and with fast startup time is presented. The circuit was fabricated in 180 nm CMOS technology and analyzed with respect to sensitivity, current consumption and startup time under highly duty-cycled operation. The receiver achieves a sensitivity of 81.6±7.4 µV at a data rate of 100 kb/s, with an active current consumption of 39.1±0.6 µA and a startup time below 250 µs. Operating the receiver as specified by the proposed LLPM synchronization strategy reduces the current consumption to a measured average value of 73 nA. In conclusion, this work suggests synchronous duty-cycling for CIC-based implant synchronization as a promising concept to severely reduce the current consumption of contemporary dual-chamber LLPMs. Consequently, device longevity may be increased significantly, potentially reducing the frequency of costly and complication-prone re-interventions.

12.
Article in English | MEDLINE | ID: mdl-38655610

ABSTRACT

AIMS: Pacemaker (PM) patients may require a subsequent upgrade to an implantable cardioverter defibrillator (ICD). Limited data exists on this patient population. We sought to characterize this population, to assess predictors for ICD upgrade, and to report the outcome. METHODS: From our prospective PM and ICD implantation registry, all patients who underwent PM and/or ICD implantations at our center were analyzed. Patient characteristics and outcomes of PM patients with subsequent ICD upgrade were compared to age- and sex-matched patients with de novo ICD implantation, and to PM patients without subsequent upgrade. RESULTS: Of 1'301 ICD implantations, 60 (5%) were upgraded from PMs. Median time from PM implantation to ICD upgrade was 2.6 years (IQR 1.3-5.4). Of 2'195 PM patients, 28 patients underwent subsequent ICD upgrades, corresponding to an estimated annual incidence of an ICD upgrade of at least 0.33%. Lower LVEF (p = .05) and male sex (p = .038) were independent predictors for ICD upgrade. Survival without death, transplant and LVAD implantation were worse both for upgraded ICD patients compared to matched patients with de novo ICD implantation (p = .05), as well as for PM patients with subsequent upgrade compared to matched PM patients not requiring an upgrade (p = .036). CONCLUSIONS: One of 20 ICD implantations are upgrade of patients with a PM. At least one of 30 PM patients will require an ICD upgrade in the following 10 years. Predictors for ICD upgrade are male sex and lower LVEF at PM implantation. Upgraded patients have worse outcomes.

13.
JAMA Cardiol ; 9(5): 480-485, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38568602

ABSTRACT

Importance: Arterial hypoxemia, electrolyte imbalances, and periodic breathing increase the vulnerability to cardiac arrhythmia at altitude. Objective: To explore the incidence of tachyarrhythmias and bradyarrhythmias in healthy individuals at high altitudes. Design, Setting, and Participants: This prospective cohort study involved healthy individuals at altitude (8849 m) on Mount Everest, Nepal. Recruitment occurred from January 25 to May 9, 2023, and data analysis took place from June to July 2023. Exposure: All study participants underwent 12-lead electrocardiogram, transthoracic echocardiography, and exercise stress testing before and ambulatory rhythm recording both before and during the expedition. Main Outcome: The incidence of a composite of supraventricular (>30 seconds) and ventricular (>3 beats) tachyarrhythmia and bradyarrhythmia (sinoatrial arrest, second- or third-degree atrioventricular block). Results: Of the 41 individuals recruited, 100% were male, and the mean (SD) age was 33.6 (8.9) years. On baseline investigations, there were no signs of exertional ischemia, wall motion abnormality, or cardiac arrhythmia in any of the participants. Among 34 individuals reaching basecamp at 5300 m, 32 participants climbed to 7900 m or higher, and 14 reached the summit of Mount Everest. A total of 45 primary end point-relevant events were recorded in 13 individuals (38.2%). Forty-three bradyarrhythmic events were documented in 13 individuals (38.2%) and 2 ventricular tachycardias in 2 individuals (5.9%). Nine arrhythmias (20%) in 5 participants occurred when climbers were using supplemental bottled oxygen, whereas 36 events (80%) in 11 participants occurred at lower altitudes when no supplemental bottled oxygen was used. The proportion of individuals with arrhythmia remained stable across levels of increasing altitude, while event rates per 24 hours numerically increased between 5300 m (0.16 per 24 hours) and 7300 m (0.37 per 24 hours) before decreasing again at higher altitudes, where supplemental oxygen was used. None of the study participants reported dizziness or syncope. Conclusion and Relevance: In this study, more than 1 in 3 healthy individuals experienced cardiac arrhythmia during the climb of Mount Everest, thereby confirming the association between exposure to high altitude and incidence of cardiac arrhythmia. Future studies should explore the potential implications of these rhythm disturbances.


Subject(s)
Altitude , Arrhythmias, Cardiac , Electrocardiography , Mountaineering , Humans , Male , Adult , Prospective Studies , Nepal/epidemiology , Arrhythmias, Cardiac/epidemiology , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/physiopathology , Female , Incidence , Exercise Test , Bradycardia/epidemiology , Bradycardia/physiopathology , Bradycardia/etiology , Echocardiography
14.
Article in English | MEDLINE | ID: mdl-38609733

ABSTRACT

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

15.
Heart Rhythm ; 2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38614191

ABSTRACT

BACKGROUND: Pulsed-field ablation (PFA) has shown promising data in terms of safety and procedural efficiency for pulmonary vein isolation (PVI), with similar long-term outcomes compared to radiofrequency ablation (RFA) and cryoballoon ablation (CBA) in patients with paroxysmal atrial fibrillation (AF). OBJECTIVE: The purpose of this study was to compare the procedural and long-term outcomes in patients with persistent AF undergoing PVI using PFA, CBA, or RFA. METHODS: Consecutive patients with persistent AF undergoing first PVI with PFA, CBA, or RFA were included. Patients underwent 7-day Holter electrocardiography at 3, 6, and 12 months postablation. The primary outcome was recurrence of any atrial arrhythmia after a 90-day blanking period. Safety outcomes included the composite of in-hospital major adverse events. RESULTS: A total of 533 patients with persistent AF underwent PVI using PFA (n = 214, 39%), CBA (n = 190, 36%), or RFA (n = 129, 24%). Procedures with PFA guided by fluoroscopy were shorter than those with CBA (median 60 minutes; interquartile range [IQR] 53-80 minutes vs 84 minutes; IQR 68-101 minutes; P ≤ .001), and procedures with PFA in combination with 3-dimensional electroanatomic mapping were shorter than those with RFA (median 101 minutes; IQR 85-126 minutes vs 171 minutes; IQR 141-204 minutes; P < .001). Acute safety events occurred in 2.3%, 2.6%, and 0.8% in the PFA, CBA, and RFA groups, respectively (P = .545). The 1-year confounder-adjusted estimate for freedom from atrial arrhythmias was 62.1% for CBA, 55.3% for PFA, and 48.3% for RFA (CBA vs PFA: P = .79; CBA vs RFA: P = .009; PFA vs RFA: P = .010). CONCLUSION: In patients with persistent AF undergoing first PVI, 1-year confounder-adjusted outcomes are better with PFA and CBA than with RFA.

16.
Europace ; 26(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38449430

ABSTRACT

The second generation of transcatheter pacing systems, called Micra AV, can provide atrioventricular (AV) synchronous pacing via a new pacing algorithm relying on sensing mechanical atrial contraction. Several novel programming parameters were introduced to enable AV synchronous pacing, including an A3 window and A4 window as well as a conduction mode switch and an activity mode switch. In addition to several automated features, manual programming optimization of some of the novel parameters is key to improving AV synchrony. A solid knowledge of the features and their programming is essential for electrophysiologists implanting or following patients with Micra AV devices. Differences in programming optimization might partially explain the high variability of AV synchrony published in real-world data reports. This article reviews the key programming parameters of Micra AV. Subsequently, optimal programming recommendations for defined patient profiles are presented. Those were established by consensus within an expert panel comprised of 11 European electrophysiologists from high-volume Micra AV centres. The patient profiles were (1) high degree AV block and slow sinus rhythm; (2) high degree AV block and fast sinus rhythm; and (3) intermittent AV block. The panel recommended to evaluate the mechanical atrial activity on transthoracic echocardiography prior to implant. It was also agreed that Auto A3 Threshold and Tracking Check should be turned off in all patients, AV conduction mode switch should be turned off in all patients with high degree AV block, and the lower rate should be programmed to 50 bpm with exceptions based on individual clinical assessment. Future studies will be useful to evaluate the strength of those recommendations to improve the AV synchrony.


Subject(s)
Atrioventricular Block , Pacemaker, Artificial , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Cardiac Pacing, Artificial/adverse effects , Arrhythmias, Cardiac/therapy , Heart Rate/physiology
17.
JACC Clin Electrophysiol ; 10(5): 900-912, 2024 May.
Article in English | MEDLINE | ID: mdl-38430087

ABSTRACT

BACKGROUND: Pulmonary vein isolation (PVI) alone is insufficient to treat many patients with persistent atrial fibrillation (PersAF). Adjunctive left atrial posterior wall (LAPW) ablation with thermal technologies has revealed lack of efficacy, perhaps limited by the difficulty in achieving lesion durability amid concerns of esophageal injury. OBJECTIVES: This study aims to compare the safety and effectiveness of PVI + LAPW ablation vs PVI in patients with PersAF using pulsed-field ablation (PFA). METHODS: In a retrospective analysis of the MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-approval Clinical Use of Pulsed Field Ablation) registry, we studied consecutive PersAF patients undergoing post-approval treatment with a pentaspline PFA catheter. The primary effectiveness outcome was freedom from any atrial arrhythmia of ≥30 seconds. Safety outcomes included the composite of acute and chronic major adverse events. RESULTS: Of the 547 patients with PersAF who underwent PFA, 131 (24%) received adjunctive LAPW ablation. Compared to PVI-alone, patients receiving adjunctive LAPW ablation were younger (65 vs 67 years of age, P = 0.08), had a lower CHA2DS2-VASc score (2.3 ± 1.6 vs 2.6 ± 1.6, P = 0.08), and were more likely to receive electroanatomical mapping (48.1% vs 39.0%, P = 0.07) and intracardiac echocardiography imaging (46.1% vs 17.1%, P < 0.001). The 1-year Kaplan-Meier estimate for freedom from atrial arrhythmias was not statistically different between groups in the full (PVI + LAPW: 66.4%; 95% CI: 57.6%-74.4% vs PVI: 73.1%; 95% CI: 68.5%-77.2%; P = 0.68) and propensity-matched cohorts (PVI + LAPW: 71.7% vs PVI: 68.5%; P = 0.34). There was also no significant difference in major adverse events between the groups (2.2% vs 1.4%, respectively, P = 0.51). CONCLUSIONS: In patients with PersAF undergoing PFA, as compared to PVI-alone, adjunctive LAPW ablation did not improve freedom from atrial arrhythmia at 12 months.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Atria , Pulmonary Veins , Humans , Atrial Fibrillation/surgery , Male , Female , Aged , Catheter Ablation/methods , Catheter Ablation/adverse effects , Middle Aged , Retrospective Studies , Heart Atria/surgery , Pulmonary Veins/surgery , Treatment Outcome , Registries
18.
Article in English | MEDLINE | ID: mdl-38478165

ABSTRACT

BACKGROUND: CRAFT was an international, multicentre, randomised controlled trial across 11 sites in the United UK and Switzerland. Given the evidence that pulmonary vein triggers may be responsible for atrial flutter (AFL) as well as atrial fibrillation (AF), we hypothesised that cryoballoon pulmonary vein isolation (PVI) would provide greater symptomatic arrhythmia reduction than cavotricuspid isthmus (CTI) ablation, whilst also reducing the subsequent burden of AF. Twelve-month outcomes were previously reported. In this study, we report the extended outcomes of the CRAFT study to 36 months. METHODS: Patients with typical AFL and no evidence of AF were randomised 1:1 to cryoballoon PVI or radiofrequency CTI. All patients received an implantable loop recorder (ILR) for continuous cardiac rhythm monitoring. The primary outcome was time-to-symptomatic arrhythmia recurrence > 30 s. Secondary outcomes included time-to-first-AF episode ≥ 2 min. The composite safety outcome included death, stroke and procedural complications. RESULTS: A total of 113 patients were randomised to cryoballoon PVI (n = 54) or radiofrequency CTI ablation (n = 59). Ninety-one patients reconsented for extended follow-up beyond 12 months. There was no difference in the primary outcome between arms, with the primary outcome occurring in 12 PVI vs 11 CTI patients (HR 0.97; 95% CI 0.43-2.20; p = 0.994). AF ≥ 2 min was significantly less frequent in the PVI arm, affecting 26 PVI vs 36 CTI patients (HR 0.48; 95% CI 0.29-0.79; p = 0.004). The composite safety outcome occurred in 5 PVI and 6 CTI patients (p = 0.755). CONCLUSION: Cryoballoon PVI shows similar efficacy to radiofrequency CTI ablation in reducing symptomatic arrhythmia recurrence in patients presenting with isolated typical AFL but significantly reduces the occurrence of subsequent AF.

19.
Europace ; 26(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38385529

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is a well-established strategy for the treatment of paroxysmal atrial fibrillation (PAF). Despite randomized controlled trials and real-world data showing the promise of pulsed-field ablation (PFA) for this treatment, long-term efficacy and safety data demonstrating single-procedure outcomes off antiarrhythmic drugs remain limited. The aim of the FARA-Freedom Study was to evaluate the long-term efficacy and safety of PFA using the pentaspline catheter for PAF. METHODS AND RESULTS: FARA-Freedom, a prospective, non-randomized, multicentre study, enrolled patients with PAF undergoing de novo PVI with PFA, who were followed for 12 months with weekly transtelephonic monitoring and a 72-h Holter ECG at 6 and 12 months. The primary safety endpoint was a composite of device- or procedure-related serious adverse events out to 7 days post-ablation and PV stenosis or atrioesophageal (AE) fistula out to 12 months. Treatment success is a composite of acute PVI and chronic success, which includes freedom from any documented atrial tachyarrhythmia longer than 30 s, use of antiarrhythmic drugs or cardioversion after a 3-month blanking period, or use of amiodarone or repeat ablation at any time. The study enrolled 179 PAF patients (62 ± 10 years, 39% female) at 13 centres. At the index procedure, all PVs were successfully isolated with the pentaspline PFA catheter. Procedure and left atrial dwell times, with a 20-min waiting period, were 71.9 ± 17.6 and 41.0 ± 13.3 min, respectively. Fluoroscopy time was 11.5 ± 7.4 min. Notably, monitoring compliance was high, with 88.4 and 90.3% with weekly events and 72-h Holter monitors, respectively. Freedom from the composite primary effectiveness endpoint was 66.6%, and 41 patients had atrial tachyarrhythmia recurrence, mostly recurrent atrial fibrillation (31 patients). The composite safety endpoint occurred in two patients (1.1%), one tamponade and one transient ischaemic attack. There was no coronary spasm, PV stenosis, or AE fistula. There were four cases of transient phrenic nerve palsy, but all resolved during the index procedure. CONCLUSION: In this prospective, non-randomized, multicentre study, PVI using a pentaspline PFA catheter was effective in treating PAF patients despite rigourous endpoint definitions and high monitoring compliance and demonstrated favourable safety. REGISTRATION: Clinical Trials.gov Identifier: NCT05072964 (sponsor: Boston Scientific Corporation).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Fistula , Pulmonary Veins , Female , Humans , Male , Anti-Arrhythmia Agents , Atrial Fibrillation/surgery , Catheter Ablation/methods , Constriction, Pathologic/surgery , Fistula/surgery , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Tachycardia/surgery , Treatment Outcome , Middle Aged , Aged
20.
JACC Clin Electrophysiol ; 10(4): 698-708, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38340118

ABSTRACT

BACKGROUND: Pulsed-field ablation (PFA) is a novel nonthermal ablation technology with high procedural safety and efficiency for pulmonary vein isolation (PVI). Premarket data showed high PVI durability during mandatory remapping studies. Data on lesion durability in real-world patients with clinically indicated redo procedures are scarce. OBJECTIVES: This study sought to report PVI durability rates in patients undergoing a clinically indicated redo procedure after an index PVI using PFA. METHODS: Patients from 7 European centers undergoing an index PVI using PFA were included the EU-PORIA (European Real-world Outcomes With Pulsed Field Ablation in Patients With Symptomatic Atrial Fibrillation) registry. In patients with subsequent left atrial redo procedures due to arrhythmia recurrence, 3-dimensional electroanatomical maps were acquired. PVI durability was assessed on a per-vein and per-patient level, and sites of reconnections and predictors of lesion durability were identified. RESULTS: Of 1,184 patients (62% paroxysmal atrial fibrillation) undergoing an index PVI using PFA, 272 (23%) had an arrhythmia recurrence. Of these, 144 (53%) underwent a left atrial redo procedure a median of 7 (Q1-Q3: 5-10) months after the first ablation. Three-dimensional electroanatomical maps identified 404 of 567 pulmonary veins (71%) with durable isolation. In 54 patients (38%), all pulmonary veins were durably isolated. Prior operator experience with cryoballoon ablation was associated with a higher PVI durability compared to operators with only point-by-point radiofrequency experience (76% vs 60%; P < 0.001). Neither the operators' cumulative experience in atrial fibrillation ablation (≤5 vs >5 years) nor the size of the PFA device used (31 mm vs 35 mm) had an impact on subsequent lesion durability (both P > 0.50). CONCLUSIONS: In 144 patients with arrhythmia recurrence after PFA PVI, durable isolation was observed in 71% of the pulmonary veins during the redo procedure, and 38% of all patients showed durable isolation of all veins.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Registries , Humans , Pulmonary Veins/surgery , Atrial Fibrillation/surgery , Male , Female , Middle Aged , Catheter Ablation/methods , Aged , Europe , Treatment Outcome , Recurrence , Reoperation/statistics & numerical data