1.
Am Surg ; 80(11): 1124-7, 2014 Nov.
Article in English | MEDLINE | ID: mdl-25347503

ABSTRACT

Diaphragm injuries after blunt trauma are uncommon but require early diagnosis to expedite repair. The advancing technology of computed tomography (CT) scanners has improved the detection of almost all traumatic injuries; however, the literature regarding the diagnostic accuracy of CT scan for blunt diaphragm injuries is lacking. The purpose of this study was to determine the CT scan findings in the setting of known blunt diaphragm injury. We performed a retrospective review of all blunt trauma patients with a known diaphragm injury confirmed at laparotomy who also had a preoperative CT scan of the torso. Every CT scan was retrospectively reviewed by a board-certified radiologist for evidence of diaphragm injury as well as associated abdominal and thoracic injuries. Forty-two patients sustaining blunt trauma had preoperative CT scans of the torso and a diaphragm injury confirmed at laparotomy. Only 57 per cent of CT scans showed evidence of diaphragmatic injury. The most common thoracic injury identified was a pulmonary contusion (79%). Although the advancement of imaging technology has markedly improved the diagnosis and management of blunt traumatic injuries, the detection of diaphragm injuries using CT continues to be low and reconstructions do not help in finding diaphragm injuries.


Subject(s)
Diaphragm/injuries , Tomography, X-Ray Computed/methods , Wounds, Nonpenetrating/diagnostic imaging , Adult , Contrast Media , Diaphragm/surgery , Female , Humans , Iohexol , Male , Registries , Retrospective Studies , Wounds, Nonpenetrating/surgery
2.
J Trauma ; 66(3): 641-6; discussion 646-7, 2009 Mar.
Article in English | MEDLINE | ID: mdl-19276732

ABSTRACT

BACKGROUND: Efforts to determine the suitability of low-grade pancreatic injuries for nonoperative management have been hindered by the inaccuracy of older computed tomography (CT) technology for detecting pancreatic injury (PI). This retrospective, multicenter American Association for the Surgery of Trauma-sponsored trial examined the sensitivity of newer 16- and 64-multidetector CT (MDCT) for detecting PI, and sensitivity/specificity for the identification of pancreatic ductal injury (PDI). METHODS: Patients who received a preoperative 16- or 64-MDCT followed by laparotomy with a documented PI were enrolled. Preoperative MDCT scans were classified as indicating the presence (+) or absence (-) of PI and PDI. Operative notes were reviewed and all patients were confirmed as PI (+), and then classified as PDI (+) or (-). As all patients had PI, an analysis of PI specificity was not possible. PI patients formed the pool for further PDI analysis. As sensitivity and specificity data were available for PDI, multivariate logistic regression was performed for PDI patients using the presence or absence of agreement between CT and operative note findings as an independent variable. Covariates were age, gender, Injury Severity Score, mechanism of injury, presence of oral contrast, presence of other abdominal injuries, performance of the scan as part of a dedicated pancreas protocol, and image thickness < or =3 mm or > or =5 mm. RESULTS: Twenty centers enrolled 206 PI patients, including 71 PDI (+) patients. Intravenous contrast was used in 203 studies; 69 studies used presence of oral contrast. Eight-nine percent were blunt mechanisms, and 96% were able to have their duct status operatively classified as PDI (+) or (-). The sensitivity of 16-MDCT for all PI was 60.1%, whereas 64-MDCT was 47.2%. For PDI, the sensitivities of 16- and 64-MDCT were 54.0% and 52.4%, respectively, with specificities of 94.8% for 16-MDCT scanners and 90.3% for 64-MDCT scanners. Logistic regression showed that no covariates were associated with an increased likelihood of detecting PDI for either 16- or 64-MDCT scanners. The area under the curve was 0.66 for the 16-MDCT PDI analysis and 0.77 for the 64-MDCT PDI analysis. CONCLUSION: Sixteen and 64-MDCT have low sensitivity for detecting PI and PDI, while exhibiting a high specificity for PDI. Their use as decision-making tools for the nonoperative management of PI are, therefore, limited.


Subject(s)
Pancreas/injuries , Tomography, Spiral Computed/instrumentation , Wounds, Nonpenetrating/diagnostic imaging , Wounds, Penetrating/diagnostic imaging , Administration, Oral , Adolescent , Adult , Contrast Media/administration & dosage , Female , Humans , Infusions, Intravenous , Injury Severity Score , Laparotomy , Male , Middle Aged , Pancreas/surgery , Pancreatic Ducts/diagnostic imaging , Pancreatic Ducts/injuries , Pancreatic Ducts/surgery , Retrospective Studies , Sensitivity and Specificity , United States , Wounds, Nonpenetrating/surgery , Wounds, Penetrating/surgery , Young Adult