Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
J Card Surg ; 29(3): 353-8, 2014 May.
Article in English | MEDLINE | ID: mdl-24762036

ABSTRACT

BACKGROUND: This study evaluated the long-term results of thoracic endovascular aortic repair (TEVAR) of nontraumatic rupture of the descending thoracic aorta. METHODS: This was a retrospective and observational single-center study. During the 10-year study period, 21 patients (6 males) with an average age of 66.1 ± 12.4 (range 31-81) years underwent emergency TEVAR for nontraumatic rupture of the descending thoracic aorta. The underlying aortic pathologies causing the rupture were degenerative aneurysms in 11 patients, complicated type B dissection in nine, and erosion hemorrhage due to neoplasia in one patient. RESULTS: The 30-day mortality rate was 9.5% (2/21). Two patients died postoperatively: one from a repeat aortic rupture and the other from pneumonia. Two patients underwent early endovascular reintervention. After a median follow-up of 65.6 ± 50.4 (range 1.5-44) months, 10 patients died, resulting in a late mortality of 52.6% (10/19). Six patients (31.5%) developed major complications requiring late reintervention. There was no mortality with reintervention. CONCLUSIONS: Endovascular treatment of the descending thoracic aorta in patients with nontraumatic rupture is a promising treatment option in an emergency setting with a relatively low mortality rate. Despite encouraging early results, TEVAR is associated with a high reintervention rate and poor survival due to nonaortic or procedure-related mortality in the long term.


Subject(s)
Aorta, Thoracic/surgery , Aortic Rupture/surgery , Endovascular Procedures/methods , Adult , Aged , Aged, 80 and over , Aortic Rupture/etiology , Emergencies , Endovascular Procedures/mortality , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Rupture, Spontaneous , Time Factors , Treatment Outcome
2.
J Card Surg ; 29(1): 66-73, 2014 Jan.
Article in English | MEDLINE | ID: mdl-24279879

ABSTRACT

BACKGROUND: Endovascular stent grafting of the descending thoracic aorta has evolved rapidly and is now the standard of care for certain patient subsets. However, the durability of this technique is limited by the development of technique-specific complications at mid-term follow-up. The aim of this study was to evaluate the incidence, techniques, and outcomes of secondary intervention for complications after stent grafting of the descending thoracic aorta. METHODS: Between March 2001 and November 2011, 152 patients underwent endovascular thoracic aortic repair (TEVAR). We identified 19 (12.5%) patients from this cohort who required secondary interventions. RESULTS: The indications for TEVAR were type B aortic dissection in 12 patients, thoracic aortic aneurysm in six patients, and intramural hematoma in one patient. The mean time between TEVAR and secondary intervention was 20.49 ± 24.90 months (range, 1.2-83 months). A secondary endovascular intervention was required in eleven patient, six patients required secondary surgical therapy, and hybrid procedures were performed in two patients. Endoleaks were the most common indication for a secondary intervention. The 30-day mortality rate was 10.5% (2/19). Two perioperative deaths were observed following surgical therapy. During the mean follow-up of 78.06 ± 37.37 months (range, 23-142 months) after TEVAR, four unrelated deaths occurred, two patients were lost to follow-up, and four patients required a further intervention. CONCLUSIONS: Secondary intervention after endovascular stent grafting of the descending thoracic aorta was not infrequently required and can be performed with acceptable risks. However, serial, systematic follow-up is essential to detect late complications and to perform secondary procedures, preferably under elective circumstances.


Subject(s)
Aorta, Thoracic/surgery , Aortic Aneurysm, Thoracic/surgery , Aortic Dissection/surgery , Endovascular Procedures/methods , Stents , Adult , Aged , Endoleak/surgery , Endovascular Procedures/mortality , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications/surgery , Reoperation , Risk , Survival Rate , Time Factors , Treatment Outcome
3.
J Vasc Surg ; 59(3): 675-83, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24342063

ABSTRACT

OBJECTIVE: To analyze early and late mortality, venous morbidity, reinfection, and freedom from reintervention after using the femoral vein (FV) for vascular reconstruction with infection of the aortoiliofemoral axis. METHODS: By reviewing our database, 86 patients could be identified with implantation of FV grafts in infected fields between November 1995 and July 2012. The patient records were retrospectively analyzed and follow-up information obtained from patients or their general physician. Seventy-one patients presented with prosthetic graft infection and 15 with an infected aneurysm. For data analysis, patients were divided into an aortoiliac (n = 67) and a femoral group (n = 19). Study end points assessed were early and late mortality, incidence of deep vein thrombosis of the FV donor limb, graft patency, limb salvage, reinfection, and freedom from reintervention. RESULTS: Sixty-seven aortoiliac reconstructions were performed using 84 FV grafts with an operative mortality of 9%. After a mean follow-up of 45 months, survival, patency, limb salvage, and freedom from reintervention were 45%, 97%, 94%, and 91%, respectively, at 5 years. Twenty FV grafts were employed for 19 femoral reconstructions with an operative mortality of 10.5%. Here, mean follow-up was 35 months and survival, patency, limb salvage, and freedom from reintervention were 29%, 87%, 93%, and 81%, respectively, at 5 years. Specimen culture confirmed Staphylococcus (epidermidis and aureus) as the predominant microorganism. Venous morbidity after FV harvest showed an incidence of deep venous thrombosis of 13.7% for popliteal and 10.6% for tibial level at a follow-up of 24 months with only mild clinical symptoms (21% limb swelling). CONCLUSIONS: Vascular reconstruction using autologous FV in arterial and graft infection of the aortoiliofemoral axis provides durable long-term results with acceptable mortality and morbidity.


Subject(s)
Aneurysm, Infected/surgery , Aortic Aneurysm/surgery , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis/adverse effects , Femoral Artery/surgery , Femoral Vein/transplantation , Iliac Aneurysm/surgery , Plastic Surgery Procedures/methods , Prosthesis-Related Infections/surgery , Aged , Aged, 80 and over , Aneurysm, Infected/diagnosis , Aneurysm, Infected/microbiology , Aneurysm, Infected/mortality , Aortic Aneurysm/diagnosis , Aortic Aneurysm/microbiology , Aortic Aneurysm/mortality , Aortography/methods , Autografts , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Female , Femoral Artery/diagnostic imaging , Femoral Artery/microbiology , Femoral Artery/physiopathology , Femoral Vein/physiopathology , Graft Occlusion, Vascular/etiology , Graft Occlusion, Vascular/physiopathology , Humans , Iliac Aneurysm/diagnosis , Iliac Aneurysm/microbiology , Iliac Aneurysm/mortality , Kaplan-Meier Estimate , Limb Salvage , Male , Middle Aged , Prosthesis-Related Infections/diagnosis , Prosthesis-Related Infections/microbiology , Prosthesis-Related Infections/mortality , Plastic Surgery Procedures/adverse effects , Plastic Surgery Procedures/mortality , Recurrence , Reoperation , Retrospective Studies , Risk Factors , Time Factors , Tomography, X-Ray Computed , Treatment Outcome , Vascular Patency , Venous Thrombosis/etiology , Venous Thrombosis/physiopathology
4.
Med Klin (Munich) ; 97(4): 204-8, 2002 Apr 15.
Article in German | MEDLINE | ID: mdl-11977575

ABSTRACT

BACKGROUND: Stentgrafts for endovascular treatment of abdominal aortic aneurysms (AAA) have been commercially available since 1994, with now large numbers of implantations all over the world. PATIENTS AND METHODS: From 1994-2001, 115 patients were treated with Stentor, Vanguard and Talent stentgrafts in our institution. RESULTS: Late complications of the first- and second-generation stentgrafts as radiologic or surgical interventions to maintain complete exclusion of the aneurysm amounted to 30% with an additional 22% for observed endoleaks and configuration changes of the stentgraft. Third-generation stentgrafts had a lower complication rate of 12.2% for interventions and 18.3% for late endoleaks and graft changes. CONCLUSION: High costs of the devices, a pretty high late complication rate, and the uncertain maintenance of stentgraft function to prevent aneurysm rupture currently limit the widespread application of this new technology, leaving conventional aneurysmectomy the standard for aneurysm treatment and reserving the endovascular method for selected patients.


Subject(s)
Angioplasty, Balloon , Aortic Aneurysm, Abdominal/therapy , Blood Vessel Prosthesis Implantation , Stents , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortography , Female , Follow-Up Studies , Humans , Male , Middle Aged , Outcome and Process Assessment, Health Care , Prosthesis Design , Prosthesis Failure
SELECTION OF CITATIONS
SEARCH DETAIL
...