Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 224
Filter
1.
Odontology ; 2024 Jul 24.
Article in English | MEDLINE | ID: mdl-39046588

ABSTRACT

To evaluate the microstructural characterization, mechanical properties and antimicrobial activity of acrylic resins incorporated with different concentrations of reduced graphene oxide (rGO). Specimens were made of self-cured and heat-cured acrylic resins for the control group and concentrations of 0.5%, 1%, and 3%. The microstructural characterization was evaluated by scanning electron microscopy (SEM) and energy-dispersive X-ray (EDS). For mechanical testing, flexural strength, and Knoop hardness tests were performed. Microbiological evaluations were performed by colony forming units (CFU) analysis, tetrazolium salt reduction (XTT), and SEM images. The modified acrylic resins showed increased mechanical properties at low concentrations (p < 0.05) and with reduced S. mutans (p < 0.05). Reduced graphene oxide interfered with the mechanical performance and microbiological properties of acrylic resins depending on the concentration of rGO, and type of polymerization and microorganism evaluated. The incorporation of graphene compounds into acrylic resins is an alternative to improve the antimicrobial efficacy and performance of the material.

2.
Cranio ; : 1-7, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-39010709

ABSTRACT

OBJECTIVE: Anxiety tends to increase muscle tension and painful symptoms; however, its symptoms can be associated with temporomandibular dysfunction (TMD). Therefore, it is crucial for professionals to identify the presence of both comorbidities and determine whether they are related. This study aims to systematically evaluate the literature and answer the question: "Is there an association between anxiety and TMD in adults?" METHODS: The study followed the PRISMA protocol and was registered in PROSPERO. The custom search was performed in PubMed, Embase, Scopus, and Lilacs databases, as inclusion criteria observational studies that evaluated the association between anxiety and TMD in adults. RESULTS: A total of 1640 articles were found. After removing duplicates, 988 were evaluated by title and abstract. Of these, 28 were selected for reading in full, of which 13 were included in the present review. CONCLUSION: The association of anxiety with TMD is positive, except for the minority indicating a low relationship between the disorders, which is explained by neuroscience.

3.
Future Microbiol ; : 1-11, 2024 Jul 09.
Article in English | MEDLINE | ID: mdl-38979570

ABSTRACT

Aim: To develop a ß-AgVO3 gel and evaluate its physicochemical stability and antifungal activity against Candida albicans. Materials & methods: The gel was prepared from the minimum inhibitory concentration (MIC) of ß-AgVO3. The physicochemical stability was evaluated by centrifugation, accelerated stability (AS), storage (St), pH, syringability, viscosity and spreadability tests and antifungal activity by the agar diffusion. Results: The MIC was 62.5 µg/ml. After centrifugation, AS and St gels showed physicochemical stability. Lower viscosity and higher spreadability were observed for the higher ß-AgVO3 concentration and the minimum force for extrusion was similar for all groups. Antifungal effect was observed only for the ß-AgVO3 gel with 20xMIC. Conclusion: The ß-AgVO3 gel showed physicochemical stability and antifungal activity.


We used silver and vanadium to make a gel that can kill fungi in the mouth. We looked at the color of the gel, it's smell and also checked how well it lasted. The gel turned yellow and had no smell and did not spoil for at least 2 months. When we tested the gel against a type of fungus, it worked as well as another medicine called chlorhexidine, which is sold in pharmacies. But when we compared it with another medicine called nystatin, our gel was not as effective in killing the fungus.

4.
Heliyon ; 10(11): e32029, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38868038

ABSTRACT

This study aimed to incorporate ß-AgVO3 and rGO into self-curing (SC) and heat-curing (HC) acrylic resins and to evaluate their physicochemical, mechanical, and antimicrobial properties while correlating them with the characterized material structure. Acrylic resin samples were prepared at 0 % (control), 0.5 %, 1 %, and 3 % for both nanoparticles. The microstructural characterization was assessed by scanning electron microscopy (SEM) (n = 1) and energy dispersive X-ray spectroscopy (EDS) (n = 1). The physicochemical and mechanical tests included flexural strength (n = 10), Knoop hardness (n = 10), roughness (n = 10), wettability (n = 10), sorption (n = 10), solubility (n = 10), porosity (n = 10), and color evaluation (n = 10). The microbiological evaluation was performed by counting colony-forming units (CFU/mL) and cell viability (n = 8). The results showed that the ß-AgVO3 samples showed lower counts of Candida albicans, Pseudomonas aeruginosa, and Streptococcus mutans due to their promising physicochemical properties. The mechanical properties were maintained with the addition of ß-AgVO3. The rGO samples showed higher counts of microorganisms due to the increase in physicochemical properties. It can be concluded that the incorporation of ß-AgVO3 into acrylic resins could be an alternative to improve the antimicrobial efficacy and performance of the material.

5.
Int J Sports Med ; 2024 Jun 19.
Article in English | MEDLINE | ID: mdl-38897226

ABSTRACT

Emerging evidence suggests that resistance training (RT) can mitigate respiratory muscle weakness in hemodialysis (HD) patients. However, the underlying mechanisms responsible for these beneficial effects remain unclear. The purpose of this study was to assess the impact of periodized RT on respiratory muscle strength and its relationship with handgrip strength (HGS), fat-free mass (FFM), nitric oxide (NO), and interdialytic weight gain (IWG) in HD patients. Thirty-three patients were randomly assigned to two groups: control (CTL; n=18) and RT (n=15). RT group did not perform any additional exercise training specific to the respiratory tract. Maximal inspiratory (MIP) and expiratory (MEP) pressures, peak expiratory flow (PEF), HGS, FFM, NO, and IWG were measured before and after the intervention period. Participants in the RT group engaged in a 24-week RT program, three times per week. RT resulted in significant improvements in MIP, MEP, PEF, as well as enhancements in HGS, FFM, NO, and IWG (p<0.05). Notably, inverse correlations were observed between MIP (r= -0.37, p=0.03) and PEF (r= -0.4, p=0.02) with IWG. Thus, the amelioration of HGS and FFM coincided with a reduction in respiratory muscle weakness among HD patients. Decreased IWG and increased circulating NO are plausible mechanisms contributing to these improvements.

6.
Am J Dent ; 37(3): 126-130, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38899991

ABSTRACT

PURPOSE: To evaluate the antimicrobial activity of dentifrices based on Malva sylvestris and propolis and the effect on the acrylic resin. METHODS: The inhibitory effect against Candida albicans, Enterococcus faecalis and Streptococcus mutans was determined. The specimens of resin were divided into groups: Control (brushing with distilled water); brushing with Colgate; brushing with Protex; brushing with Malvatricin, brushing with Proporalcare Dental Gel and brushing with Green Propolis Dental Gel. Brushing was carried out in a brushing machine. Roughness and color were assessed. The data were analyzed by ANOVA, followed by the Bonferroni post test (α= 0.05). RESULTS: The products evaluated showed antimicrobial activity against all microorganisms (P< 0.05), except Proporalcare Dental Gel, which was not effective against E. faecalis. Greater roughness (P< 0.05) was observed in the samples treated with Colgate. The samples from control and Protex groups showed the lowest color variation and the highest luminosity, with a difference in relation to the others (P< 0.05), which showed higher values, although clinically acceptable. CLINICAL SIGNIFICANCE: The dentifrices based on natural products can be indicated for cleaning prostheses, since they showed antimicrobial activity and did not cause perceptible color changes of the resin tested. The dentifrices did not produce adverse effects on the surface of the resin or did so less than the conventional dentifrice.


Subject(s)
Acrylic Resins , Candida albicans , Dentifrices , Denture Bases , Streptococcus mutans , Dentifrices/pharmacology , Streptococcus mutans/drug effects , Candida albicans/drug effects , Enterococcus faecalis/drug effects , Propolis/pharmacology , Surface Properties , Materials Testing , Color , Humans , Anti-Infective Agents/pharmacology , Toothbrushing , Toothpastes/pharmacology , Toothpastes/chemistry , Silicic Acid
7.
Future Microbiol ; 19(8): 655-665, 2024.
Article in English | MEDLINE | ID: mdl-38700286

ABSTRACT

Aim: To evaluate the biological and mechanical properties of an adhesive with nanostructured silver vanadate (AgVO3). Materials & methods: Specimens in poly(methyl methacrylate) (PMMA) were treated with Ultra Corega Cream (UCCA) denture adhesive with or without AgVO3. Biofilms of Candida albicans, Candida glabrata and Streptococcus mutans were grown and the viable cells counted. Fluorescence microscopy was used. The viability of the VERO cell and adhesive strength were evaluated. Results: All concentrations of AgVO3 reduced the biofilm formation and showed no cytotoxic effect. At 5 min and 24 h, UCCA with 5 and 10% AgVO3 showed better performance, respectively. Conclusion: AgVO3 promoted the antibiofilm activity of the adhesive, with a positive effect on the adhesive strength, and was biocompatible.


What is this summary about? Some people wear false teeth called dentures. They use a special glue to keep these false teeth in their mouths. It is important to clean dentures well and remove the glue every day. If the dentures get dirty, they can cause infections of the gums. Doctors and dentists can help, but sometimes medicines do not work well. This study checked to see whether adding a medicine that can kill bacteria into the glue could stop gum swelling and other illnesses, or make them better.What were the results? The glue containing the medicine killed microbes like fungi and bacteria. It also stuck things together well and was safe to use.What do the results mean? Using this special glue could help people with dentures to avoid illness.


Subject(s)
Biofilms , Streptococcus mutans , Vanadates , Biofilms/drug effects , Vanadates/pharmacology , Animals , Vero Cells , Chlorocebus aethiops , Streptococcus mutans/drug effects , Biocompatible Materials/pharmacology , Candida albicans/drug effects , Candida albicans/physiology , Silver/pharmacology , Silver/chemistry , Dentures/microbiology , Materials Testing , Polymethyl Methacrylate/chemistry , Dental Cements/pharmacology , Dental Cements/chemistry , Bacterial Adhesion/drug effects , Adhesives/pharmacology , Adhesives/chemistry
8.
J Prosthet Dent ; 2024 May 09.
Article in English | MEDLINE | ID: mdl-38729792

ABSTRACT

STATEMENT OF PROBLEM: Incorporating and coating with antimicrobials are techniques that can confer antimicrobial action on polymethyl methacrylate (PMMA) denture bases, which can accumulate microorganisms and promote oral and systemic disease. PURPOSE: The purpose of this systematic review was to answer the question: "Do techniques for incorporating and coating antimicrobial agents in PMMA promote antimicrobial action?" MATERIAL AND METHODS: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) checklist guidelines were followed, and the SCOPUS, PubMed/Medline, EMBASE, and Science Direct databases searched. The studies were selected in 2 stages, reading the titles and abstracts and then reading the selected studies in full. The risk of bias was analyzed by adapting the quasi-experimental studies tool by the Joanna Briggs Institute (JBI). RESULTS: A total of 970 articles were found in the databases; 71 were duplicates and, after reading the abstracts, 38 were selected for full reading. From these, 6 were excluded because they did not fulfill the inclusion criteria, and 32 studies were included in this review. Autopolymerizing, heat- polymerizing, and light-polymerizing resins were evaluated, with the incorporating technique prevailing over the coating, but both techniques effectively promoted antimicrobial activity. CONCLUSIONS: Incorporating and coating antimicrobial agents are effective methods of promoting antimicrobial activity in PMMA. Combining the 2 methods led to increased antimicrobial activity compared with each individually.

9.
Saudi Dent J ; 36(5): 733-739, 2024 May.
Article in English | MEDLINE | ID: mdl-38766297

ABSTRACT

Introduction: Post-processing (PP) is performed to improve the surface, which can favor microbial adhesion and consequent pathological manifestations that impair the indication of polylactic acid (PLA) obtained by fused filament fabrication (FFF) for biomedical applications. This aims to evaluate the influence of chemical, thermal, and mechanical PP on the adhesion of Streptococcus mutants and Candida albicans, roughness, and wettability of the PLA obtained by FFF with and without thermal aging. Methods: The specimens were designed in the 3D modeling program and printed. The chemical PP was performed by immersion in chloroform, the thermal by the annealing method, and the mechanical by polishing. Thermal aging was performed by alternating the temperature from 5 °C to 55 °C with 5000 cycles. Colony-forming unit (CFU/mL) counting was performed on dual-species biofilm of C. albicans and S. mutans. Roughness was analyzed by rugosimeter and wettability by the sessile drop technique. Data were verified for normality using the Shapiro-Wilk test, two-way ANOVA (α = 0.05) applied for CFU and wettability, and Kruskal-Wallis (α = 0.05) for roughness. Results: Chemical, thermal, and mechanical PP methods showed no influence on CFU/mL of C. albicans (p = 0.296) and S. mutans (p = 0.055). Thermal aging did not influence microbial adhesion. Chemical PP had lower roughness, which had increased after aging. Wettability of the mechanical PP was lower. Conclusions: Post-processing techniques, do not present an influence on the adhesion of S. mutans and C. albicans in PLA obtained by FFF, chemical PP reduced roughness, and mechanical reduced wettability. Thermal aging did not alter the microbial adhesion and altered the roughness and wettability.

10.
Dental Press J Orthod ; 29(2): e2423282, 2024.
Article in English | MEDLINE | ID: mdl-38775601

ABSTRACT

OBJECTIVE: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. METHODS: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. RESULTS: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. CONCLUSIONS: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


Subject(s)
Dental Alloys , Dental Implants , Flexural Strength , Materials Testing , Microscopy, Electron, Scanning , Orthodontic Anchorage Procedures , Stainless Steel , Surface Properties , Titanium , Torque , Titanium/chemistry , Stainless Steel/chemistry , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Dental Alloys/chemistry , In Vitro Techniques , Spectrometry, X-Ray Emission , Dental Stress Analysis , Humans , Stress, Mechanical , Bone Density
11.
Heliyon ; 10(9): e30108, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38774089

ABSTRACT

The objective of the systematic review is to find an answer to a question: "What is the influence of the building direction of titanium implants produced by additive manufacturing on their physical and mechanical properties?" This review followed the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA 2020) and was registered in the Open Science Framework (OSF) (osf.io/rdc84). Searches were performed in PubMed, Scopus, Science Direct, Embase, and Google Scholar databases on February 17th, 2024. Articles were chosen in 2 steps by 2 blinded reviewers based on previously selected inclusion criteria: In vitro studies that evaluated the influence of the impression direction of titanium implants produced by additive manufacturing on their physical and mechanical properties were selected. Articles were excluded that (1) did not use additive technology to obtain the implants, 2) used surfaces other than titanium, 3) did not evaluate the direction of impression, 4) Studies with only in vivo analyses, clinical studies, systematic reviews, book chapters, short communications, conference abstracts, case reports, and personal opinions.). In the initial search, 581 results were found. Of this total, 108 were excluded for duplication and, after applying the eligibility criteria, 16 articles were included in the present review. The risk of bias was analyzed using the RoBDEMAT. The risk of bias was analyzed using the RoBDEMAT. In addition, the coefficient of interagreement of the reviewers (Cohen's Kappa) and the certainty of evidence by GRADE were analyzed. In general, different impression angles showed variations in the physical and mechanical characteristics of the groups evaluated, including roughness, tensile strength, hardness, and modulus of elasticity. While some impression orientations resulted in greater strength or hardness, others showed greater elasticity or lower surface roughness. These findings suggest that print orientation plays a significant role in determining material properties. It can be concluded that printing directions influence the physical and mechanical properties of titanium implants and the studies included showed that the 0°, 45°, and 90° directions are the most evaluated as they present lower probabilities of structural anisotropies and provide better results in their roughness, hardness, tensile and compressive strength.

13.
Int J Oral Maxillofac Implants ; 39(2): 235-242, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38657216

ABSTRACT

PURPOSE: To analyze the effectiveness of coating of abutments with antimicrobial agents and their influence on the physicochemical and biologic properties of the coated materials. MATERIALS AND METHODS: This work was registered in Open Science Framework (osf.io/6tkcp) and followed the PRISMA protocols. A search of two independent reviewers of articles published up to October 29, 2021, was performed in the Embase, PubMed, Science Direct, and Scopus databases. RESULTS: The databases found a total of 1,474 references. After excluding the duplicates, 1,050 remained. After reading the titles and abstracts and applying the inclusion criteria, 13 articles remained and were read in full. A total of 8 articles were included in this systematic review. Different antimicrobial agents have been used to coat abutments, including graphene oxide, polydopamine, titanium and zirconium nitride, lactoferrin, tetracycline, silver, and doxycycline with varied release times. Titanium-coated silver showed a better antimicrobial agent release time of up to 28 days. Chemical analysis confirmed the presence of antimicrobials on the surface after coating. Different pathogenic microorganisms, such as Streptococcus sanguinis, Streptococcus oralis, and Staphylococcus aureus, were inhibited when in contact with the coated surface. CONCLUSIONS: This review showed that there is still no consensus on which is the better antimicrobial agent and which coated materials have the better performance. However, the association of surface coating of abutments with antimicrobials is feasible and can benefit many patients, which can support their clinical use to favor the healing process and prevent infections that can lead to treatment failure with dental implants.


Subject(s)
Anti-Infective Agents , Dental Abutments , Humans , Anti-Infective Agents/pharmacology , Coated Materials, Biocompatible/chemistry , Coated Materials, Biocompatible/pharmacology , Dental Abutments/microbiology , Surface Properties , Titanium/chemistry
14.
J Dent ; 145: 104984, 2024 06.
Article in English | MEDLINE | ID: mdl-38583645

ABSTRACT

OBJECTIVES: To incorporate the nanostructured silver vanadate decorated with silver nanoparticles (AgVO3) into denture base materials: heat-cured (HC) and 3D printed (3DP) resins, at concentrations of 2.5 %, 5 %, and 10 %; and to evaluate the antimicrobial activity in two multi-species biofilm: (1) Candida albicans, Candida glabrata, and Streptococcus mutans, (2) Candida albicans, Pseudomonas aeruginosa, and Staphylococcus aureus, and the wettability. METHODS: The AgVO3 was added to the HC powder, and printed samples were coated with 3DP with AgVO3 incorporated. After biofilm formation, the antimicrobial activity was evaluated by colony forming units per milliliter (CFU/mL), metabolic activity, and epifluorescence microscopy. Wettability was assessed by the contact angles with water and artificial saliva. RESULTS: In biofilm (1), HC-5 % and HC-10 % showed activity against S. mutans, HC-10 % against C. glabrata, and HC-10 % and 3DP-10 % had higher CFU/mL of C. albicans. 3DP-5 % had lower metabolic activity than the 3DP control. In biofilm (2), HC-10 % reduced S. aureus and P. aeruginosa, and HC-5 %, 3DP-2.5 %, and 3DP-5 % reduced S. aureus. 3DP incorporated with AgVO3, HC-5 %, and HC-10 % reduced biofilm (2) metabolic activity. 3DP-5 % and 3DP-10 % increased wettability with water and saliva. CONCLUSION: HC-10 % was effective against C. glabrata, S. mutans, P. aeruginosa, and S. aureus, and HC-5 % reduced S. mutans and S. aureus. For 3DP, 2.5 % and 5 % reduced S. aureus. The incorporation of AgVO3 into both resins reduced the metabolic activity of biofilms but had no effect on C. albicans. The wettability of the 3DP with water and saliva increased with the addition of AgVO3. CLINICAL SIGNIFICANCE: The incorporation of silver vanadate into the denture base materials provides antimicrobial efficacy and can prevent the aggravation of oral and systemic diseases. The incorporation of nanomaterials into printed resins is challenging and the coating is an alternative to obtain the inner denture base with antimicrobial effect.


Subject(s)
Biofilms , Candida albicans , Denture Bases , Metal Nanoparticles , Pseudomonas aeruginosa , Silver , Staphylococcus aureus , Streptococcus mutans , Vanadates , Wettability , Biofilms/drug effects , Streptococcus mutans/drug effects , Candida albicans/drug effects , Staphylococcus aureus/drug effects , Vanadates/pharmacology , Vanadates/chemistry , Pseudomonas aeruginosa/drug effects , Silver/pharmacology , Silver/chemistry , Denture Bases/microbiology , Metal Nanoparticles/chemistry , Anti-Infective Agents/pharmacology , Candida glabrata/drug effects , Printing, Three-Dimensional , Materials Testing , Humans , Nanostructures , Silver Compounds/pharmacology , Silver Compounds/chemistry , Dental Materials/chemistry , Dental Materials/pharmacology
15.
Biofouling ; 40(2): 114-129, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38538551

ABSTRACT

This study aimed to answer the question formulated according to the PICO strategy: 'Which essential oils show antimicrobial activity against biofilms formed on dental acrylic resin?' composed by population (dental acrylic resin), intervention (application of essential oils), comparison (denture cleansers, antifungal drugs, chlorhexidine, and oral mouthwashes), and outcome (antibiofilm activity). In vitro experimental studies evaluating the activity of EOs on biofilm formed on acrylic resin were included. PRISMA guidelines were followed, and the search was performed in the PubMed, Science Direct, Embase, and Lilacs databases and in the gray literature using Google Scholar and ProQuest in December 2023. A manual search of the reference lists of the included primary studies was performed. Of the 1467 articles identified, 37 were selected for full-text reading and 12 were included. Twelve EOs were evaluated, of which 11 showed activity against Candida spp., 3 against Staphylococcus aureus, and 1 against Pseudomonas aeruginosa. The EOs of Cymbopogon citratus, Cinnamomum zeylanicum, and Cymbopogon nardus showed higher action than chlorhexidine, C. nardus higher than Listerine, C. citratus higher than nystatin, and Melaleuca alternifolia higher than fluconazole and nystatin. However, chlorhexidine was more effective than Lippia sidoides and Salvia officinalis, sodium hypochlorite was more effective than L. sidoides, nystatin was more effective than Zingiber officinale, Amphotericin B more effective than Eucalyptus globulus and M. alternifolia. In conclusion, the EOs of C. zeylanicum, C. citratus, C. nardus, and M. alternifolia showed antimicrobial activity to reduce biofilm on dental acrylic resin.


Subject(s)
Acrylic Resins , Biofilms , Oils, Volatile , Antifungal Agents/pharmacology , Biofilms/drug effects , Candida albicans , Chlorhexidine/pharmacology , Nystatin/pharmacology , Oils, Volatile/pharmacology
16.
J Sport Health Sci ; 13(4): 548-558, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38431193

ABSTRACT

BACKGROUND: Hemodialysis (HD) per se is a risk factor for thrombosis. Considering the growing body of evidence on blood-flow restriction (BFR) exercise in HD patients, identification of possible risk factors related to the prothrombotic agent D-dimer is required for the safety and feasibility of this training model. The aim of the present study was to identify risk factors associated with higher D-dimer levels and to determine the acute effect of resistance exercise (RE) with BFR on this molecule. METHODS: Two hundred and six HD patients volunteered for this study (all with a glomerular filtration rate of <15 mL/min/1.73 m2). The RE + BFR session consisted of 50% arterial occlusion pressure during 50 min sessions of HD (intradialytic exercise). RE repetitions included concentric and eccentric lifting phases (each lasting 2 s) and were supervised by a strength and conditioning specialist. RESULTS: Several variables were associated with elevated levels of D-dimer, including higher blood glucose, citrate use, recent cardiovascular events, recent intercurrents, higher inflammatory status, catheter as vascular access, older patients (>70 years old), and HD vintage. Furthermore, RE + BFR significantly increases D-dimer after 4 h. Patients with borderline baseline D-dimer levels (400-490 ng/mL) displayed increased risk of elevating D-dimer over the normal range (≥500 ng/mL). CONCLUSION: These results identified factors associated with a heightened prothrombotic state and may assist in the screening process for HD patients who wish to undergo RE + BFR. D-dimer and/or other fibrinolysis factors should be assessed at baseline and throughout the protocol as a precautionary measure to maximize safety during RE + BFR.


Subject(s)
Fibrin Fibrinogen Degradation Products , Renal Dialysis , Resistance Training , Thrombosis , Humans , Renal Dialysis/adverse effects , Resistance Training/methods , Fibrin Fibrinogen Degradation Products/analysis , Fibrin Fibrinogen Degradation Products/metabolism , Male , Thrombosis/etiology , Thrombosis/blood , Female , Middle Aged , Aged , Risk Factors , Blood Glucose/metabolism , Regional Blood Flow , Age Factors
17.
J Prosthet Dent ; 131(4): 742.e1-742.e8, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38383281

ABSTRACT

STATEMENT OF PROBLEM: To improve the osseointegration of dental implants and reduce microbiological growth, different micro- and nanoscale surface topographies can be used. PURPOSE: The purpose of this in vitro study was to evaluate the influence of Ti-6Al-4V with 4 surfaces, machined (DU), machined+hydroxyapatite (DUHAp), machined+acid-alkali treatment (DUAA), and additive manufacturing (DMA), on the physical, chemical, and microbiological properties. MATERIAL AND METHODS: The topography of Ti-6Al-4V disks with the 4 surfaces was evaluated by scanning electron microscopy (SEM), the chemical composition by energy dispersive X-ray spectroscopy (EDS), and the crystalline structure by X-ray diffraction (XRD). Physical and chemical properties were analyzed by using wettability and surface free energy, roughness, and microbial adhesion against Staphylococcus aureus by colony forming units (CFU). One-way ANOVA analysis of variance and the Tukey multiple comparisons test were applied to evaluate the data, except CFU, which was submitted to the Kruskal-Wallis nonparametric test (α=.05). RESULTS: DU photomicrographs showed a topography characteristic of a polished machined surface, DUHAp and DUAA exhibited patterns corresponding to the surface modifications performed, and in DMA the presence of partially fused spherical particles was observed. The EDS identified chemical elements inherent in the Ti-6Al-4V, and the DUHAp and DUAA disks also had the ions from the treatments applied. XRD patterns revealed similarities between DU and DMA, as well as characteristic peaks of hydroxyapatite (HA) in the DUHAp disk and the DUAA. Compared with DU and DMA the DUHAp and DUAA groups showed hydrophilic behavior with smaller contact angles and higher surface free energy (P<.05). DMA showed a higher mean value of roughness, different from the others (P<.05), and a higher CFU for S. aureus (P=.006). CONCLUSIONS: DUHAp and DUAA showed similar behaviors regarding wettability, surface free energy, and bacterial adhesion. Among the untreated groups, DMA exhibited higher roughness, bacterial adhesion, and lower wettability and surface free energy.


Subject(s)
Alloys , Titanium , Titanium/therapeutic use , Titanium/chemistry , Staphylococcus aureus , Durapatite/therapeutic use , Wettability , Surface Properties , Microscopy, Electron, Scanning
18.
Heliyon ; 10(4): e25525, 2024 Feb 29.
Article in English | MEDLINE | ID: mdl-38384570

ABSTRACT

Objective: The aim of this study was to evaluate the roughness, hardness, and color change of pit and fissure sealants of two commercial brands (Fluroshield ™ and Ultraseal XT ™) incorporated with nanostructured silver vanadate nanomaterial decorated with silver nanoparticles (ß-AgVO3) in concentrations (0% - control, 2.5% and 5%). Material and methods: Two commercial brands Fluroshield TM and Ultraseal XT ™ were used to make the samples with dimensions of 6 × 6 × 4 mm. The control group was made according to the manufacturer's instructions and in the groups with the addition of ß-AgVO3, the nanomaterial was added proportionally by mass at percentages of 2.5% and 5%. Roughness properties were evaluated using a 3D Laser Confocal Microscope (n = 10), Knoop microhardness by Microdurometer (n = 10), and color change by Portable Color Spectrophotometer on the CIEDE2000 system (n = 10). Data were evaluated by one-way ANOVA with Bonferroni adjustment and Tukey's mean comparison test at a 5% significance level. Results: Ultraseal XT ™ sealant roughness showed a significant difference between concentrations with the highest mean for the 5% group (P = 0.010). Regarding the hardness, both sealants showed no significant difference between the groups. Fluroshield ™ sealant showed a significant difference in ΔE00 between the control-2.5% 24.93 (3.49) and control-5% 28.41 (2.58). Conclusion: It may be concluded that the incorporation of ß-AgVO3 influenced the increase in roughness for Ultraseal XT ™ pit and fissure sealant, did not interfere with the microhardness of both sealants, and promoted a change in the color of Fluroshield ™ sealant within clinically acceptable limits.

19.
J Cachexia Sarcopenia Muscle ; 15(2): 718-725, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38272859

ABSTRACT

BACKGROUND: Short-daily haemodialysis (SDH) has been strongly recommended over conventional haemodialysis (CHD) for end-stage kidney disease patients, though few studies have directly compared the effects of these two haemodialysis (HD) modalities on clinical variables related to patient's health. METHODS: We conducted a cross-sectional study in individuals undergoing HD, comparing epidemiological, clinical, metabolic, inflammatory, anthropometric, bone health/metabolism, and skeletal muscle function according to dialysis modality. One-hundred seventy-eight patients (20.8% females, 62 ± 2.5 years old), were analysed in this study, 86 (48%) of whom were undergoing CHD versus 92 (51%) who were undergoing SDH. RESULTS: SDH patients had significantly higher serum albumin levels (3.93 vs. 3.66 g/dL, P < 0.0001) and higher Kt/v (2.6 vs. 2.38, P < 0.0001). SDH group presented a significantly lower number of erythropoietin-stimulating agents compared with CHD group (percentage: 53.3 vs. 83.7%, P < 0.0001) and had lower levels of serum phosphate (4.9 vs. 5.3 mg/dL, P = 0.004) and parathyroid hormone (PTH) (398.4 vs. 480.4 pg/mL, P < 0.001) compared with CHD patients. In terms of bone health and metabolism, SDH patients had significantly higher total BMD, femur BMD, lumbar BMD, and femoral neck BMD compared with CHD patients (all P < 0.05). SDH patients also had lower anti-osteogenic and inflammatory biomarkers, including FGF23, sclerostin, TNF, IL-18, IL-17a, and C-reactive peptide (all P < 0.05). CHD modality was demonstrated to be a risk factor for low BMD (odds ratio: 4.02; 95% CI: 1.59-10.2, P = 0.003). In terms of skeletal muscle function, SDH patients had significantly higher 6-minute walking test (444.6 vs. 424.9 m, P = 0.04) and higher fat-free mass (52.3 vs. 51.68 kg, P = 0.02) compared with CHD patients. Higher fat-free mass and handgrip strength were associated with a 34% and 23% lower risk of low BMD, respectively. SDH patients had lower levels of the uremic toxin asymmetric dimethyl-l-arginine (ADMA) (1.8 vs. 2.07 µM, P = 0.002) and fasting blood glucose (132.6 vs. 141.7 mg/dL, P < 0.02) than CHD group. SDH patients also displayed higher levels of haemoglobin when compared with CHD group (11.9 vs. 10.2 g/dL, P < 0.0001). CONCLUSIONS: The present study improves our understanding of the relationship between dialysis modality and clinical variables that may influence HD patient's health. Grip strength and lean mass were positively correlated with bone mineral density in HD patients regardless of dialysis modality. SDH was associated with better bone mineral density, inflammatory profile, and skeletal muscle function when compared with CHD patients. These findings provide more evidence of the clinical benefits of SDH that should be explored in greater detail.


Subject(s)
Bone Density , Kidney Failure, Chronic , Female , Humans , Middle Aged , Male , Bone Density/physiology , Hand Strength , Cross-Sectional Studies , Kidney Failure, Chronic/therapy , Kidney Failure, Chronic/complications , Renal Dialysis/adverse effects , Muscle Strength
20.
J Dent ; 145: 104836, 2024 06.
Article in English | MEDLINE | ID: mdl-38199325

ABSTRACT

OBJECTIVE: To investigate the impact of incorporating the antimicrobial nanomaterial ß-AgVO3 into orthodontic resin, focusing on degree of conversion, surface characteristics, microhardness, adhesion properties, and antimicrobial activity. METHODS: The 3 M Transbond XT resin underwent modification, resulting in three groups (Control, 2.5% addition, 5% addition) with 20 specimens each. Fourier transform infrared spectroscopy assessed monomer conversion. Laser confocal microscopy examined surface roughness, and microhardness was evaluated using Knoop protocols. Shear strength was measured before and after artificial aging on 36 premolar teeth. Microbiological analysis against S. mutans and S. sanguinis was conducted using the agar diffusion method. RESULTS: Degree of conversion remained unaffected by time (P = 0.797), concentration (P = 0.438), or their interaction (P = 0.187). The 5% group exhibited the lowest surface roughness, differing significantly from the control group (P = 0.045). Microhardness showed no significant differences between concentrations (P = 0.740). Shear strength was highest in the control group (P < 0.001). No significant differences were observed in the samples with or without thermocycling (P = 0.759). Microbial analysis revealed concentration-dependent variations, with the 5% group exhibiting the largest inhibition halo (P < 0.001). CONCLUSIONS: Incorporating ß-AgVO3 at 2.5% and 5% concentrations led to significant differences in surface roughness, adhesion, and antimicrobial activity. Overall, resin modification positively impacted degree of conversion, surface characteristics, microhardness, and antimicrobial activity. Further research is warranted to determine clinically optimal concentrations that maximize antimicrobial benefits while minimizing adverse effects on adhesion properties. CLINICAL SIGNIFICANCE: Incorporating ß-AgVO3 into orthodontic resin could improve patient quality of life by prolonging intervention durability and reducing the impact of cariogenic microorganisms. The study's findings also hold promise for the industry, paving the way for the development of new materials with antimicrobial properties for potential applications in the health sector.


Subject(s)
Materials Testing , Metal Nanoparticles , Shear Strength , Silver , Streptococcus mutans , Surface Properties , Vanadates , Streptococcus mutans/drug effects , Humans , Silver/chemistry , Silver/pharmacology , Vanadates/chemistry , Vanadates/pharmacology , Metal Nanoparticles/chemistry , Spectroscopy, Fourier Transform Infrared , Hardness , Resin Cements/chemistry , Streptococcus sanguis/drug effects , Orthodontic Brackets/microbiology , Microscopy, Confocal , Nanostructures/chemistry , Bacterial Adhesion/drug effects , Silver Compounds/pharmacology , Silver Compounds/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...