Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
J Prosthet Dent ; 109(5): 319-24, 2013 May.
Article in English | MEDLINE | ID: mdl-23684282

ABSTRACT

STATEMENT OF PROBLEM: Although cement-retained implant prostheses are widely used, the quantification of optimal retention remains controversial, and new dental luting agents should be evaluated. PURPOSE: The purpose of this study was to compare, in vitro, the casting retention on implant abutments after cementation with 3 commercially available luting agents and an experimental luting agent (castor oil polyurethane, COP) with variable weight percentages (wt%) of calcium carbonate (CaCO3). MATERIAL AND METHODS: Seventy-two palladium-silver cast copings were fabricated and divided into 6 groups: Temp Bond interim cement (TB); zinc phosphate cement (ZP); Rely X ARC resin cement (RX); pure COP (COP); COP + 10% wt% CaCO3 filler (COP 10); and COP + 50% wt% CaCO3 filler (COP 50). After cementation, the specimens were stored in distilled water at 37°C for 24 hours and subjected to removal force tests in a universal testing machine (5 kN; 0.5 mm/min). Statistical analyses were performed with the Kruskal-Wallis and Student-Newman-Keuls tests (α=.05). RESULTS: The median values of casting retention (N) were as follows: TB=57.20 ±10.4; ZP=343.56 ±50.3; RX=40.07 ±9.7; COP=258.98 ±41.4; COP 10=466.57 ±79.3; and COP 50=209.63 ±31.4. The Kruskal-Wallis test showed significant differences among the groups (P<.01). TB and RX had the lowest mean retention values; COP, COP 10, and COP 50 were equal to ZP, and COP 10 had the highest retention. CONCLUSIONS: The casting retention on implant-abutments provided by COP was similar to that of copings cemented with zinc phosphate and may be influenced by the addition of calcium carbonate.


Subject(s)
Castor Oil/chemistry , Cementation/methods , Dental Cements/chemistry , Dental Implant-Abutment Design , Dental Prosthesis Retention , Bisphenol A-Glycidyl Methacrylate/chemistry , Calcium Carbonate/chemistry , Crowns , Dental Alloys/chemistry , Dental Stress Analysis/instrumentation , Eugenol/chemistry , Humans , Materials Testing , Palladium/chemistry , Polyethylene Glycols/chemistry , Polymethacrylic Acids/chemistry , Polyurethanes/chemistry , Resin Cements/chemistry , Resins, Plant/chemistry , Silver/chemistry , Stress, Mechanical , Temperature , Time Factors , Water/chemistry , Zinc Oxide/chemistry , Zinc Phosphate Cement/chemistry
2.
ISRN Dent ; 2012: 898051, 2012.
Article in English | MEDLINE | ID: mdl-22957262

ABSTRACT

Objective. The aim of this study was to evaluate the compressive strength and setting time of MTA and Portland cement (PC) associated with bismuth oxide (BO), zirconium oxide (ZO), calcium tungstate (CT), and strontium carbonate (SC). Methods. For the compressive strength test, specimens were evaluated in an EMIC DL 2000 apparatus at 0.5 mm/min speed. For evaluation of setting time, each material was analyzed using Gilmore-type needles. The statistical analysis was performed with ANOVA and the Tukey tests, at 5% significance. Results. After 24 hours, the highest values were found for PC and PC + ZO. At 21 days, PC + BO showed the lowest compressive strength among all the groups. The initial setting time was greater for PC. The final setting time was greater for PC and PC + CT, and MTA had the lowest among the evaluated materials (P < 0.05). Conclusion. The results showed that all radiopacifying agents tested may potentially be used in association with PC to replace BO.

SELECTION OF CITATIONS
SEARCH DETAIL
...