Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Acad Radiol ; 2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38453602

ABSTRACT

RATIONALE AND OBJECTIVES: We aimed to compare superb microvascular imaging (SMI)-based radiomics methods, and contrast-enhanced ultrasound (CEUS)-based radiomics methods to the American College of Radiology Thyroid Imaging Reporting and Data System (ACR TI-RADS) for classifying thyroid nodules (TNs) and reducing unnecessary fine-needle aspiration biopsy (FNAB) rate. MATERIALS AND METHODS: This retrospective study enrolled a dataset of 472 pathologically confirmed TNs. Radiomics characteristics were extracted from B-mode ultrasound (BMUS), SMI, and CEUS images, respectively. After eliminating redundant features, four radiomics scores (Rad-scores) were constructed. Using multivariable logistic regression analysis, four radiomics prediction models incorporating Rad-score and corresponding US features were constructed and validated in terms of discrimination, calibration, decision curve analysis, and unnecessary FNAB rate. RESULTS: The diagnostic performance of the BMUS + SMI radiomics method was better than ACR TI-RADS (area under the curve [AUC]: 0.875 vs. 0.689 for the training cohort, 0.879 vs. 0.728 for the validation cohort) (P < 0.05), and comparable with BMUS + CEUS radiomics method (AUC: 0.875 vs. 0.878 for the training cohort, 0.879 vs. 0.865 for the validation cohort) (P > 0.05). Decision curve analysis showed that the BMUS+SMI radiomics method could achieve higher net benefits than the BMUS radiomics method and ACR TI-RADS when the threshold probability was between 0.13 and 0.88 in the entire cohort. When applying the BMUS+SMI radiomics method, the unnecessary FNAB rate reduced from 43.4% to 13.9% in the training cohort and from 45.6% to 18.0% in the validation cohorts in comparison to ACR TI-RADS. CONCLUSION: The dual-modal SMI-based radiomics method is convenient and economical and can be an alternative to the dual-modal CEUS-based radiomics method in helping radiologists select the optimal clinical strategy for TN management.

2.
Cancer Imaging ; 24(1): 17, 2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38263209

ABSTRACT

BACKGROUND: American College of Radiology (ACR) Thyroid Imaging Reporting and Data System (TI-RADS, TR) 4 and 5 thyroid nodules (TNs) demonstrate much more complicated and overlapping risk characteristics than TR1-3 and have a rather wide range of malignancy possibilities (> 5%), which may cause overdiagnosis or misdiagnosis. This study was designed to establish and validate a dual-modal ultrasound (US) radiomics nomogram integrating B-mode ultrasound (BMUS) and contrast-enhanced ultrasound (CEUS) imaging to improve differential diagnostic accuracy and reduce unnecessary fine needle aspiration biopsy (FNAB) rates in TR 4-5 TNs. METHODS: A retrospective dataset of 312 pathologically confirmed TR4-5 TNs from 269 patients was collected for our study. Data were randomly divided into a training dataset of 219 TNs and a validation dataset of 93 TNs. Radiomics characteristics were derived from the BMUS and CEUS images. After feature reduction, the BMUS and CEUS radiomics scores (Rad-score) were built. A multivariate logistic regression analysis was conducted incorporating both Rad-scores and clinical/US data, and a radiomics nomogram was subsequently developed. The performance of the radiomics nomogram was evaluated using calibration, discrimination, and clinical usefulness, and the unnecessary FNAB rate was also calculated. RESULTS: BMUS Rad-score, CEUS Rad-score, age, shape, margin, and enhancement direction were significant independent predictors associated with malignant TR4-5 TNs. The radiomics nomogram involving the six variables exhibited excellent calibration and discrimination in the training and validation cohorts, with an AUC of 0.873 (95% CI, 0.821-0.925) and 0.851 (95% CI, 0.764-0.938), respectively. The marked improvements in the net reclassification index and integrated discriminatory improvement suggested that the BMUS and CEUS Rad-scores could be valuable indicators for distinguishing benign from malignant TR4-5 TNs. Decision curve analysis demonstrated that our developed radiomics nomogram was an instrumental tool for clinical decision-making. Using the radiomics nomogram, the unnecessary FNAB rate decreased from 35.3 to 14.5% in the training cohort and from 41.5 to 17.7% in the validation cohorts compared with ACR TI-RADS. CONCLUSION: The dual-modal US radiomics nomogram revealed superior discrimination accuracy and considerably decreased unnecessary FNAB rates in benign and malignant TR4-5 TNs. It could guide further examination or treatment options.


Subject(s)
Radiomics , Thyroid Nodule , Humans , Nomograms , Retrospective Studies , Biopsy
3.
Front Public Health ; 11: 1149964, 2023.
Article in English | MEDLINE | ID: mdl-37497023

ABSTRACT

Objective: Regular check-up with ultrasound in underserved rural and/or remote areas is hampered due to the limited availability of sonologists and ultrasound devices. This study aimed to assess the feasibility and satisfaction of health check-ups with a 5G-based robotic teleultrasound diagnostic system. Methods: In this prospective study, sonologists from two hospitals manipulated the telerobotic ultrasound system to perform teleultrasound check-ups of the liver, gallbladder, pancreas, spleen, kidneys, bladder, prostate (male), uterus and ovaries (female) for the subjects. The feasibility and satisfaction of health check-ups with a 5G-based robotic teleultrasound diagnostic system were evaluated in terms of examination results, examination duration, and satisfaction questionnaire survey. Results: A total of 546 subjects were included with the most frequently diagnosed being abdominal disorders (n = 343) and male reproductive illnesses (n = 97), of which fatty liver (n = 204) and prostatic calcification (n = 54) were the most. The median teleultrasound examination duration (interquartile range) for men and women was 9 (9-11) min and 9 (7-11) min (p = 0.236), respectively. All the subjects were satisfied with this new type of telerobotic ultrasound check-ups and 96% reported no fear of the robotic arm during the examination. Conclusion: The 5G-based teleultrasound robotic diagnostic system in health check-ups is feasible and satisfactory, indicating that this teleultrasound robot system may have significant application value in underserved rural and/or remote areas to mitigate disparity in achieving health equity.


Subject(s)
Robotic Surgical Procedures , Humans , Male , Female , Prospective Studies , Feasibility Studies , Ultrasonography/methods , Liver
5.
Front Oncol ; 13: 1007464, 2023.
Article in English | MEDLINE | ID: mdl-36776305

ABSTRACT

Purpose: The aim of this study was to investigate the diagnostic efficacy of Acoustic Radiation Force Impulse (ARFI) for benign and malignant thyroid nodules in the presence and absence of non-papillary thyroid cancer (NPTC) and to determine the cut-off values of Shear Wave Velocity (SWV) for the highest diagnostic efficacy of Virtual Touch Quantification (VTQ) and Virtual Touch Tissue Imaging and Quantification (VTIQ). Methods: The diagnostic accuracy of ARFI for benign and malignant thyroid nodules was assessed by pooling sensitivity, specificity and area under the curve (AUC) in each group in the presence and absence of both non-papillary thyroid glands, using histology and cytology as the gold standard. All included studies were divided into two groups according to VTQ and VTIQ, and each group was ranked according to the magnitude of the SWV cutoff value to determine the SWV cutoff interval with the highest diagnostic efficacy for VTQ and VTIQ. Results: A total of 57 studies were collected on the evaluation of ARFI for the diagnosis of benign and malignant thyroid nodules. The results showed that the presence of non-papillary thyroid carcinoma led to differences in the specificity of VTIQ for the identification of benign and malignant thyroid nodules, and the differences were statistically significant. In addition, the diagnostic efficacy of VTQ was best when the cutoff value of SWV was in the interval of 2.48-2.55 m/s, and the diagnostic efficacy of VTIQ was best when the cutoff value of SWV was in the interval of 3.01-3.15 m/s. Conclusion: VTQ and VTIQ have a high diagnostic value for benign and malignant thyroid nodules; however, when the malignant nodules in the study contain non-papillary thyroid carcinoma occupying the thyroid gland, the findings should be viewed in a comprehensive manner.

7.
Front Oncol ; 12: 944859, 2022.
Article in English | MEDLINE | ID: mdl-36249056

ABSTRACT

Objective: The aim of this study was to evaluate the accuracy of deep learning using the convolutional neural network VGGNet model in distinguishing benign and malignant thyroid nodules based on ultrasound images. Methods: Relevant studies were selected from PubMed, Embase, Cochrane Library, China National Knowledge Infrastructure (CNKI), and Wanfang databases, which used the deep learning-related convolutional neural network VGGNet model to classify benign and malignant thyroid nodules based on ultrasound images. Cytology and pathology were used as gold standards. Furthermore, reported eligibility and risk bias were assessed using the QUADAS-2 tool, and the diagnostic accuracy of deep learning VGGNet was analyzed with pooled sensitivity, pooled specificity, diagnostic odds ratio, and the area under the curve. Results: A total of 11 studies were included in this meta-analysis. The overall estimates of sensitivity and specificity were 0.87 [95% CI (0.83, 0.91)] and 0.85 [95% CI (0.79, 0.90)], respectively. The diagnostic odds ratio was 38.79 [95% CI (22.49, 66.91)]. The area under the curve was 0.93 [95% CI (0.90, 0.95)]. No obvious publication bias was found. Conclusion: Deep learning using the convolutional neural network VGGNet model based on ultrasound images performed good diagnostic efficacy in distinguishing benign and malignant thyroid nodules. Systematic Review Registration: https://www.crd.york.ac.nk/prospero, identifier CRD42022336701.

8.
World J Gastroenterol ; 28(38): 5530-5546, 2022 Oct 14.
Article in English | MEDLINE | ID: mdl-36304086

ABSTRACT

Artificial intelligence (AI), especially deep learning, is gaining extensive attention for its excellent performance in medical image analysis. It can automatically make a quantitative assessment of complex medical images and help doctors to make more accurate diagnoses. In recent years, AI based on ultrasound has been shown to be very helpful in diffuse liver diseases and focal liver lesions, such as analyzing the severity of nonalcoholic fatty liver and the stage of liver fibrosis, identifying benign and malignant liver lesions, predicting the microvascular invasion of hepatocellular carcinoma, curative transarterial chemoembolization effect, and prognoses after thermal ablation. Moreover, AI based on endoscopic ultrasonography has been applied in some gastrointestinal diseases, such as distinguishing gastric mesenchymal tumors, detection of pancreatic cancer and intraductal papillary mucinous neoplasms, and predicting the preoperative tumor deposits in rectal cancer. This review focused on the basic technical knowledge about AI and the clinical application of AI in ultrasound of liver and gastroenterology diseases. Lastly, we discuss the challenges and future perspectives of AI.


Subject(s)
Carcinoma, Hepatocellular , Chemoembolization, Therapeutic , Gastroenterology , Liver Neoplasms , Humans , Artificial Intelligence , Gastroenterology/methods , Carcinoma, Hepatocellular/therapy , Chemoembolization, Therapeutic/methods , Liver Neoplasms/therapy
SELECTION OF CITATIONS
SEARCH DETAIL
...