Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Zhongguo Gu Shang ; 35(4): 323-8, 2022 Apr 25.
Article in Chinese | MEDLINE | ID: mdl-35485146

ABSTRACT

OBJECTIVE: To investigate the short-term clinical effect of the computer virtual technique combined with pelvic reduction frame in the treatment of complex pelvic fractures. METHODS: Thirty patients with Tile C pelvic fractures treated by percutaneous minimally invasive pelvic reduction frame from April 2018 to April 2020 were retrospectively analyzed, including 21 males and 9 females, aged from 19 to 57 (39.40±9.85) years old. The patient's pelvic CT DICOM data were imported into Mimics software to reconstruct the virtual fracture model. Virtual reduction and nail placement were carried out on the fracture model, and then simulated fluoroscopy was carried out to record the ideal fluoroscopy orientation and angle to guide the correct fluoroscopy during operation. The operation time, fluoroscopy times and intraoperative blood loss were recorded. The quality of fracture reduction was evaluated by Matta image score standard, and the postoperative function was evaluated by Majeed function score standard. RESULTS: All 30 patients achieved closed reduction and percutaneous screw fixation. According to Matta score, the excellent and good rate of fracture reduction was 93.3%(28/30). A total of 67 channel screws were inserted, and the excellent and good rate was 98.5%(66/67). The operation time was (173.54±79.31) min, fluoroscopy time was (90.81±41.11) times, intraoperative blood loss was (81.21±43.97) ml. All incisions healed at one stage without broken nails or re-displacement of fractures. All patients were followed up for 12 months. At the final follow-up, Majeed function score was 73 to 94(85.66±5.33) scores. CONCLUSION: Computer virtual technology combined with pelvic reduction frame could rapidly, accurately and safely reduce and fix unstable pelvic fractures. Computer virtualization could help surgeons to recognition and understanding pelvic fractures, pelvic reduction frame could improve the surgeon's ability to manage complex and unstable pelvic injuries.


Subject(s)
Fractures, Bone , Pelvic Bones , Adult , Blood Loss, Surgical , Computers , Female , Fracture Fixation, Internal/methods , Fractures, Bone/surgery , Humans , Male , Middle Aged , Pelvic Bones/injuries , Retrospective Studies
2.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 35(2): 183-187, 2021 Feb 15.
Article in Chinese | MEDLINE | ID: mdl-33624471

ABSTRACT

OBJECTIVE: To explore the method and effectiveness of multidirectionally three-dimensional steel wire ring sleeve fixation in the treatment of inferior patellar pole avulsion fractures. METHODS: Betweern January 2015 and January 2019, 22 patients with inferior patellar pole avulsion fractures were admitted and treated. There were 12 males and 10 females. The age ranged from 20 to 69 years, with an average age of 39.4 years. The causes of injury included 9 cases of traffic accident and 13 cases of falling. All of them were unilateral closed injury of knee joint, including 7 cases of skin contusion around patella. Preoperative range of motion of the affected knee was (20.82±7.16)° (range, 10°-35°). The time from injury to operation ranged from 3 to 12 days, with an average of 5.9 days. During the operation, the inferior patellar avulsion fracture was reduced with forceps; the patella was circumferentially ligated through the distal bone surface of the fracture with 0.8 mm diameter steel wire; then 3 longitudinal bone tunnels were made in the upper patella, respectively. The 0.8 mm diameter steel wire passed through the bone tunnel, and the longitudinal ring was attached to the ring to fix the upper and inferior patellar fracture. Tighten the transverse and longitudinal rings with No.2 tendon suture line, then longitudinally ringed and sutured to strengthen the patella. The knee range of motion, fracture healing time, and complications were recorded. The functional recovery of the knee joint was evaluated by Böstman score. RESULTS: All incisions healed by first intention, and no incision related complications occurred. All the 22 patients were followed up 13 months to 5 years with an average of 26.7 months. The fracture healing time was 9-12 weeks (mean, 10.9 weeks). At last follow-up, the knee range of motion was (129.77±2.35)° (range, 126°-135°), showing significant difference when compared with preoperative one ( t=-67.022, P=0.000). The Böstman score ranged from 31 to 36, with an average of 34.3. No reduction loss, fracture of steel wire, failure of internal fixation, and other complications occurred during follow-up. CONCLUSION: Multidirectionally three-dimensional steel wire ring sleeve fixation in the treatment of inferior patellar pole avulsion fractures has the advantages of reliable fixation, early functional recovery, and fewer complications, so the effectiveness is satisfactory.


Subject(s)
Fractures, Avulsion , Adult , Aged , Bone Wires , Female , Humans , Male , Middle Aged , Patella/surgery , Retrospective Studies , Steel , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...