Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
Add more filters










Publication year range
1.
Environ Sci Technol ; 57(34): 12732-12740, 2023 08 29.
Article in English | MEDLINE | ID: mdl-37590181

ABSTRACT

Nonphotosynthetic microorganisms are typically unable to directly utilize light energy, but light might change the metabolic pathway of these bacteria indirectly by forming intermediates such as reactive oxygen species (ROS). This work investigated the role of light on nitrogen conversion by anaerobic ammonium oxidation (anammox) consortia. The results showed that high intensity light (>20000 lx) caused ca. 50% inhibition of anammox activity, and total ROS reached 167% at 60,000 lx. Surprisingly, 200 lx light was found to induce unexpected promotion of the nitrogen conversion rate, and ultraviolet light (<420 nm) was identified as the main contributor. Metagenomic and metatranscriptomic analyses revealed that the gene encoding cytochrome c peroxidase was highly expressed only under 200 lx light. 15N isotope tracing, gene abundance quantification, and external H2O2 addition experiments showed that photoinduced trace H2O2 triggered cytochrome c peroxidase expression to take up electrons from extracellular nonfermentative organics to synthesize NADH and ATP, thereby expediting nitrogen dissimulation of anammox consortia. External supplying reduced humic acid into a low-intensity light exposure system would result in a maximal 1.7-fold increase in the nitrogen conversion rate. These interesting findings may provide insight into the niche differentiation and widespread nature of anammox bacteria in natural ecotopes.


Subject(s)
Anaerobic Ammonia Oxidation , Cytochrome-c Peroxidase , Electrons , Hydrogen Peroxide , Reactive Oxygen Species , Nitrogen
2.
Bioresour Technol ; 363: 127896, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36070811

ABSTRACT

The anaerobic ammonium oxidation (anammox) process has the advantages of high efficiency and low energy consumption, so it has broad application prospects in biological denitrification of wastewater. However, the application of anammox technology to existing wastewater treatment is still challenging. The main problems are the insufficient supply of nitrite and the susceptibility of anammox bacteria to environmental factors. In this paper, from the perspective of the diversity of anammox bacteria, the habitats and characteristics of anammox bacteria of different genera were compared. At the same time, laboratory research and engineering applications of anammox technology in treating wastewater from different sources were reviewed, and the progress of and obstacles to the practical application of anammox technology were clarified. Finally, a focus for future research was proposed to intensively study the water quality barrier factors of anammox and its regulation strategies. Meanwhile, a combined process was developed and optimized on this basis.


Subject(s)
Ammonium Compounds , Nitrogen , Anaerobic Ammonia Oxidation , Anaerobiosis , Bacteria/genetics , Bioreactors/microbiology , Denitrification , Nitrites , Oxidation-Reduction , Sewage/microbiology , Wastewater/microbiology
3.
Water Res ; 223: 119033, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36058096

ABSTRACT

External stimulus such as light irradiation is able to deteriorate intracellular redox homeostasis and induce photooxidative damage to non-photogenic bacteria. Exploiting effective strategies to help bacteria resisting infaust stress is meaningful for achieving a stable operation of biological treatment system. In this work, selenium-doped carbon quantum dots (Se-CQDs) were blended into anaerobic ammonia oxidation (anammox) bacteria and an inorganic nanoparticle-microbe hybrid was successfully fabricated to evaluate its nitrogen removal performance under solar-simulated irradiation. It was found that the specific anammox activity decreased by 29.7 ± 5.2% and reactive oxygen species (ROS) content increased by 134.8 ± 4.1% under 50,000 lux light. Sludge activity could be completely recovered under the optimum dosage of 0.42 mL·(g volatile suspended solid) -1 Se-CQDs. Hydroxyl radical (·OH) and superoxide anion radical (·O2-) were identified as the leading ROS inducing lipid peroxidation and antioxidase function detriment. Also, the structure of ladderane lipids located on anammoxosome was destroyed by ROS and functional genes abundances declined accordingly. Although cell surface coated Se-CQDs could absorb ultraviolet light and partially mitigated the photoinhibition, the direct scavenging of ROS by intracellular Se-CQDs primarily contributed to the cellular redox homeostasis, antioxidase activity recovery and sludge activity improvement. The findings of this work provide in-depth understanding the metabolic response mechanism of anammox consortia to light irradiation and might be valuable for a more stable and sustainable nitrogen removal technology, i.e., algal-bacterial symbiotic system, development.


Subject(s)
Quantum Dots , Selenium , Anaerobic Ammonia Oxidation , Anaerobiosis , Bacteria/metabolism , Bioreactors/microbiology , Carbon/metabolism , Hydroxyl Radical/metabolism , Lipids , Nitrogen/metabolism , Oxidation-Reduction , Reactive Oxygen Species/metabolism , Selenium/metabolism , Sewage/microbiology , Superoxides
4.
Sci Total Environ ; 830: 154733, 2022 Jul 15.
Article in English | MEDLINE | ID: mdl-35337860

ABSTRACT

The rapid development of chemical industry has induced to the large amount of phenolic wastewater production. When the promising anaerobic ammonium oxidation (anammox) was employed to treat the industrial wastewater, phenolic compounds would possibly inhibit the microbial performance. Extracellular polymeric substances (EPSs) play an essential role in protecting cells from being intoxicated by phenolic compound while the distinct mechanism remains elusive. In this work, the interaction of phenol with anammox sludge EPSs and transmembrane ammonium transport (Amt) domain was explored at molecular level by using spectral method and molecular docking simulation. It was found that phenol statically quenched the fluorescent components of EPSs and the protein component dominated the interaction between EPSs and phenol. The overall interaction was an entropy-driven process with hydrophobic interaction as the main driving force, and the CO vibration responded preferentially. As phenol continued to penetrate into the cell surface, there were hydrogen bond, hydrophobic interaction force and π-π base-stacking forces between the Amt domain and phenol. The interaction between phenol and amino acid residues of the Amt domain would interfere the NH4+ transport and further affect the activity of anammox sludge. This work is beneficial for in-depth understanding the role of EPSs in protecting anammox sludge from inhibiting by phenolic pollutants.


Subject(s)
Ammonium Compounds , Extracellular Polymeric Substance Matrix , Anaerobic Ammonia Oxidation , Anaerobiosis , Bioreactors , Molecular Docking Simulation , Nitrogen , Oxidation-Reduction , Phenol , Phenols , Sewage , Spectrum Analysis , Wastewater
5.
Sci Total Environ ; 817: 153065, 2022 Apr 15.
Article in English | MEDLINE | ID: mdl-35031359

ABSTRACT

As one of the most promising autotrophic biological nitrogen removal technology, anaerobic ammonia oxidation (anammox) has gained intense attention for the past decades and several full-scale facilities have been implemented worldwide. However, anammox bacteria are easily affected by disturbed external environmental factors, which commonly leads to the fluctuations in reactor performance. The response of anammox sludge to external stress results in changes in components and structural characteristics of intracellular and extracellular polymer substances. Real-time and convenient spectral analysis of anammox sludge metabolites can give early warning of performance deterioration under external stresses, which is of great significance to the stable operation of bioreactor. This review summarized the research progress on characterizing the intracellular and extracellular metabolites of anammox sludge through spectroscopic techniques. The correlation between anammox sludge activity and its key metabolites was analyzed. Also, the limitations and future prospects of applying spectral analytical techniques for anammox bioreactor monitoring were discussed and outlooked. This review may provide valuable information for both scientific study and engineering application of anammox based nitrogen removal technology.


Subject(s)
Anaerobic Ammonia Oxidation , Sewage , Anaerobiosis , Bioreactors/microbiology , Denitrification , Nitrogen/metabolism , Oxidation-Reduction , Sewage/microbiology , Spectrum Analysis
6.
Environ Sci Technol ; 55(24): 16627-16635, 2021 12 21.
Article in English | MEDLINE | ID: mdl-34889591

ABSTRACT

Antibiotics are widely found in nitrogen-containing wastewater, which may affect the operation stability of anaerobic ammonium oxidation (anammox)-based biological treatment systems. Extracellular polymeric substances (EPSs) of anammox sludge play a pivotal role in combining with antibiotics; however, the exact role and how the structure of the leading component of EPSs (i.e., extracellular proteins) changes under antibiotic stress remain to be elucidated. Here, the interaction between sulfamethoxazole and the extracellular proteins of anammox sludge was investigated via multiple spectra and molecular simulation. Results showed that sulfamethoxazole statically quenched the fluorescent components of EPSs, and the quenching constant of the aromatic proteins was the largest, with a value of 1.73 × 104 M-1. The overall binding was an enthalpy-driven process, with ΔH = -75.15 kJ mol-1, ΔS = -0.175 kJ mol-1 K-1, and ΔG = -21.10 kJ mol-1 at 35 °C. The O-P-O and C═O groups responded first under the disturbance of sulfamethoxazole. Excessive sulfamethoxazole (20 mg L-1) would decrease the ratio of α-helix/(ß-sheet + random coil) of extracellular proteins, resulting in a loose structure. Molecular docking and dynamic simulation revealed that extracellular proteins would provide abundant sites to bind with sulfamethoxazole, through hydrogen bond and Pi-Akyl hydrophobic interaction forces. Once sulfamethoxazole penetrates into the cell surface and combines with the transmembrane ammonium transport domain, it may inhibit the NH4+ transport. Our findings enhance the understanding on the interaction of extracellular proteins and sulfamethoxazole, which may be valuable for deciphering the response property of anammox sludge under the antibiotic stress.


Subject(s)
Ammonium Compounds , Sewage , Anaerobic Ammonia Oxidation , Anaerobiosis , Bioreactors , Molecular Docking Simulation , Nitrogen , Oxidation-Reduction , Sulfamethoxazole
7.
J Fluoresc ; 26(1): 317-22, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26563227

ABSTRACT

The unique photoproperties of quantum dots are promising for potential application in bioassays. In the present study, quantum dots were applied to a luminescent oxygen channeling assay. The reaction system developed in this study was based on interaction of biotin with streptavidin. Carboxyl-modified polystyrene microspheres doped with quantum dots were biotinylated and used as acceptors. Photosensitizer-doped carboxyl-modified polystyrene microspheres were conjugated with streptavidin and used as donors. The results indicated that the singlet oxygen that was released from the donor beads diffused into the acceptor beads. The acceptor beads were then exited via thioxene, and were subsequently fluoresced. To avoid generating false positives, a high concentration (0.01 mg/mL) of quantum dots is required for application in homogeneous immunoassays. Compared to a conventional luminescent oxygen channeling assay, this quantum dots-based technique requires less time, and would be easier to automate and miniaturize because it requires no washing to remove excess labels.


Subject(s)
Fluorescence , Fluorescent Dyes/chemistry , Immunoassay , Luminescent Measurements , Oxygen/chemistry , Quantum Dots , Fluorescent Dyes/chemical synthesis , Molecular Structure
8.
Anal Chim Acta ; 891: 277-83, 2015 Sep 03.
Article in English | MEDLINE | ID: mdl-26388387

ABSTRACT

Alpha-fetoprotein (AFP), a primary marker for many diseases including various cancers, is important in clinical tumor diagnosis and antenatal screening. Most immunoassays provide high sensitivity and accuracy for determining AFP, but they are expensive, often complex, time-consuming procedures. A simple and rapid point-of-care system that integrates Eu (III) chelate microparticles with lateral flow immunoassay (LFIA) has been developed to determine AFP in serum with an assay time of 15 min. The approach is based on a sandwich immunoassay performed on lateral flow test strips. A fluorescence strip reader was used to measure the fluorescence peak heights of the test line (HT) and the control line (HC); the HT/HC ratio was used for quantitation. The Eu (III) chelate microparticles-based LFIA assay exhibited a wide linear range (1.0-1000 IU mL(-1)) for AFP with a low limit of detection (0.1 IU mL(-1)) based on 5ul of serum. Satisfactory specificity and accuracy were demonstrated and the intra- and inter-assay coefficients of variation (CV) for AFP were both <10%. Furthermore, in the analysis of human serum samples, excellent correlation (n = 284, r = 0.9860, p < 0.0001) was obtained between the proposed method and a commercially available CLIA kit. Results indicated that the Eu (III) chelate microparticles-based LFIA system provided a rapid, sensitive and reliable method for determining AFP in serum, indicating that it would be suitable for development in point-of-care testing.


Subject(s)
Chelating Agents/chemistry , Europium/chemistry , Fluoroimmunoassay/instrumentation , Reagent Strips/analysis , alpha-Fetoproteins/analysis , Equipment Design , Fluoroimmunoassay/economics , Humans , Limit of Detection , Point-of-Care Systems
9.
PLoS One ; 10(6): e0130481, 2015.
Article in English | MEDLINE | ID: mdl-26103625

ABSTRACT

In order to early screen and detect suspected biomarkers from pathogens and the human body itself, tracers or reaction strategies that can act as signal enhancers have been proposed forth at purpose. In this paper, we discussed the applicability of magnetic microparticles-assisted time-resolved fluoroimmunoassay (MMPs-TRFIA) for sensitive determination of potential analytes. Hepatitis B e antigen, antibody to hepatitis B surface antigen and free triiodothyronine were used as biomarker models to explore the reliability of the method. By coupling with bioprobes, MMPs were used as immunoassay carriers to capture target molecules. Under optimal condition, assay performance, including accuracy, precision and specificity, was outstanding and demonstrated satisfactory. To further evaluate the performance of the MMPs-TRFIA in patients, a total of 728 serum samples from hospital were analyzed for three biomarkers in parallel with the proposed method and chemiluminescence immunoassay kit commercially available. Fairly good agreements are obtained between the two methods via data analysis. Not only that but the reliability of MMPs-TRFIA has also been illustrated by three different reaction models. It is confirmed that the novel method modified with MMPs has been established and showed great potential applications in both biological detection and clinical diagnosis, including big molecule protein and low molecular weight haptens.


Subject(s)
Biomarkers/blood , Magnetics , Microspheres , Models, Biological , Fluorescent Antibody Technique , Humans , Reproducibility of Results
10.
Clin Biochem ; 47(6): 439-44, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24463229

ABSTRACT

OBJECTIVES: Diabetes mellitus is a chronic disease affecting millions of people globally and resulting in significant death rates each year. A fast, inexpensive alternative to traditional testing and monitoring techniques is desirable, since secretion of insulin and C-peptide is impaired in diabetes mellitus. DESIGN AND METHODS: A highly sensitive immunoassay was developed for the simultaneous measurement of C-peptide and insulin levels in human serum, utilizing dual-label time-resolved fluoroimmunoassay (TRFIA) and magnetic particle technologies. This assay was characteristic for a single-step sandwich-type immunoassay, wherein antibody-coated magnetic particles were used as the solid phase and Eu(3+) and Sm(3+) chelate labels were used for detection. RESULTS: Antibody-coated magnetic particles in a TRFIA format performed well in addressing a number of quantitative needs. CONCLUSIONS: The results of this assay correlated well with commercial chemiluminescence assays and provided a number a advantages, including reduced sample volume, reduced reagent and personnel costs and reduced assay time, while maintaining the required clinical sensitivity.


Subject(s)
C-Peptide/blood , Fluoroimmunoassay/methods , Insulin/blood , Antibodies/metabolism , Calibration , Diabetes Mellitus/blood , Glucagon/pharmacology , Humans , Limit of Detection , Magnetic Phenomena , Reproducibility of Results , Sensitivity and Specificity , Time Factors
11.
Luminescence ; 29(6): 591-7, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24136927

ABSTRACT

Current clinically assays, such as enzyme-linked immunosorbent assay and chemiluminescence immunoassay, for hepatitis B surface antigen (HBsAg) are inferior in terms of either sensitivity and accuracy or rapid and high-throughput analysis. A novel assay based on magnetic beads and time-resolved fluoroimmunoassay was developed for the quantitative determination of HBsAg in human serum. HBsAg was captured using two types of anti-HBsAg monoclonal antibodies (B028, S015) immobilized on to magnetic beads and detected using europium-labeled anti-HBsAg polyclonal detection antibody. Finally, the assay yielded a high sensitivity (0.02 IU/mL) and a wide dynamic range (0.02-700 IU/mL) for HBsAg when performed under optimal conditions. Satisfactory accuracy, recovery and specificity were also demonstrated. The intra- and interassay coefficients of variation were 4.7-8.7% and 3.8-7.5%, respectively. The performance of this assay was further assessed against a well-established commercial chemiluminescence immunoassay kit with 399 clinical serum samples. It was revealed that the test results for the two methods were in good correlation (Y = 1.182X - 0.017, R = 0.989). In the current study, we demonstrated that this novel time-resolved fluoroimmunoassay could be used: as a highly sensitive, automated and high-throughput immunoassay for the diagnosis of acute or chronic hepatitis B virus infection; for the screening of blood or organ donors; and for the surveillance of persons at risk of acquiring or transmitting hepatitis B virus.


Subject(s)
Hepatitis B Surface Antigens/blood , Immunoassay , Magnetic Phenomena , Humans , Luminescence , Time Factors
12.
J Clin Lab Anal ; 27(4): 277-83, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23852784

ABSTRACT

BACKGROUND: Cytokeratin 19 fragment antigen (CYFRA 21-1) is used to diagnose and monitor neoplasms. However, the main disadvantages of the currently available CYFRA 21-1 assays include heterogenous technology, being time-consuming, and having low through-put with low insensitivity. This study investigated the use of amplified luminescent proximity homogeneous immunoassay (AlphaLISA) for the quantization of CYFRA 21-1 in human serum. METHODS: The AlphaLISA kit was developed based on AlphaScreen detection technology with two different anti-CYFRA 21-1 monoclonal antibodies. One was coated on AlphaLISA acceptor beads and the other was biotinylated. Donor beads were coated with streptavidin. The test conditions were optimized and analytical performance was studied. RESULTS: The measurement range of AlphaLISA CYFRA 21-1 kit was 0.08-500 ng/ml. Assay detection limit was 0.08 ng/ml. The intra- and interassay coefficients of variation were 3.00-9.00% and 4.00-10.00%, respectively. There was no cross-reaction to alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), neuron-specific enolase (NSE), cancer antigen 19-9 (CA19-9), cytokeratins 8 (CK8), and cytokeratins 18 (CK18). The correlation coefficient of blood samples involved was 0.974 between CYFRA 21-1-AlphaLISA assay and a commercial electrochemiluminescence immunoassay (ECLIA) CYFRA 21-1 kit (Roche). CONCLUSIONS: The AlphaLISA CYFRA 21-1 kit developed in this study had favorable performance characteristics for clinical application with acceptable analytical sensitivity, specificity, and accuracy.


Subject(s)
Antigens, Neoplasm/blood , Immunoassay/methods , Keratin-19/blood , Luminescent Measurements/methods , Biomarkers, Tumor/blood , Humans , Lung Neoplasms/diagnosis , Reagent Kits, Diagnostic , Reproducibility of Results , Sensitivity and Specificity
13.
Analyst ; 138(13): 3697-704, 2013 Jul 07.
Article in English | MEDLINE | ID: mdl-23671904

ABSTRACT

In this paper, a novel time-resolved fluoroimmunoassay (TRFIA) protocol using magnetic particles for the simultaneous determination of α-fetoprotein (AFP) and the free ß-subunit of human chorionic gonadotropin (free ß-hCG) in human serum is described. The new approach uses magnetic particles as an immobilization matrix and means of separation, while the luminescent europium and samarium chelates are used as probes. The proposed method was evaluated via a single-step, sandwich-type TRFIA immunoassay of AFP and free ß-hCG as model analytes in serum. With the advantages of magnetic particles, the TRFIA immunoassay exhibited a wide dynamic range for AFP of 0.1-750 ng mL(-1), with a lower detection limit of 0.05 ng mL(-1). The dynamic range for free ß-hCG was 0.16-450 ng mL(-1), with a lower detection limit of 0.08 ng mL(-1). Satisfactory specificity, reproducibility, and recovery of the immunoassay were demonstrated. Good correlations were obtained in the analysis of 446 human serum samples between the proposed method and a commercial TRFIA kit. These results demonstrate the feasibility and potential of the new method as a rapid and highly sensitive immunoassay that could be developed into a platform for multi-analyte determinations in clinical practice.


Subject(s)
Chorionic Gonadotropin, beta Subunit, Human/analysis , Fluoroimmunoassay/methods , Magnets , alpha-Fetoproteins/analysis , Biomarkers/blood , Chorionic Gonadotropin, beta Subunit, Human/blood , Female , Humans , Pregnancy , Reproducibility of Results , Time Factors
14.
J Fluoresc ; 23(4): 649-57, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23471623

ABSTRACT

Quantum dots are not widely used in clinical diagnosis. However, the homogeneous time-resolved fluorescence assay possesses many advantages over current methods for the detection of carcinoembryonic antigen (CEA), a primary marker for many cancers and diseases. Therefore, a novel luminescent terbium chelates- (LTCs) and quantum dots-based homogeneous time-resolved fluorescence assay was developed to detect CEA. Glutathione-capped quantum dots (QDs) were prepared from oil-soluble QDs with a 565 nm emission peak. Conjugates (QDs-6 F11) were prepared with QDs and anti-CEA monoclonal antibody. LTCs were prepared and conjugates (LTCs-S001) were prepared with another anti-CEA monoclonal antibody. The fluorescence lifetime of QDs was optimized for sequential analysis. The Förster distance (R0) was calculated as 61.9 Å based on the overlap of the spectra of QDs-6 F11 and LTCs-S001. Using a double-antibody sandwich approach, the above antibody conjugates were used as energy acceptor and donor, respectively. The signals from QDs were collected in time-resolved mode and analyzed for the detection of CEA. The results show that the QDs were suitable for time-resolved fluoroassays. The spatial distance of the donor-acceptor pair was calculated to be 61.9 Å. The signals from QDs were proportional to CEA concentration. The standard curve was LogY = 2.75566 + 0.94457 LogX (R = 0.998) using the fluorescence counts (Y) of QDs and the concentrations of CEA (X). The calculated sensitivity was 0.4 ng/mL. The results indicate that water-soluble QDs are suitable for the homogenous immunoassay. This work has expanded future applications of QDs in homogeneous clinical bioassays. Furthermore, a QDs-based homogeneous multiplex immunoassay will be investigated as a biomarker for infectious diseases in future research.


Subject(s)
Carcinoembryonic Antigen/analysis , Fluoroimmunoassay/methods , Quantum Dots , Water/chemistry , Animals , Chelating Agents/chemistry , Fluorescence Resonance Energy Transfer , Fluorescent Dyes/chemistry , Solubility , Terbium/chemistry , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...