Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Res Natl Inst Stand Technol ; 119: 644-73, 2014.
Article in English | MEDLINE | ID: mdl-26601051

ABSTRACT

In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, NIST and the ATF initiated a joint project, entitled the National Ballistics Imaging Comparison (NBIC). The NBIC project aims to establish a national traceability and quality system for ballistics identifications in crime laboratories utilizing ATF's National Integrated Ballistics Information Network (NIBIN). The original NBIC was completed in 2010. In the second NBIC, NIST Standard Reference Material (SRM) 2461 Cartridge Cases were used as reference standards, and 14 experts from 11 U.S. crime laboratories each performed 17 image acquisitions and correlations of the SRM cartridge cases over the course of about half a year. Resulting correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed quality system and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.

2.
Forensic Sci Int ; 216(1-3): 168-82, 2012 Mar 10.
Article in English | MEDLINE | ID: mdl-22014973

ABSTRACT

In response to the guidelines issued by the American Society of Crime Laboratory Directors/Laboratory Accreditation Board (ASCLD/LAB-International) to establish traceability and quality assurance in U.S. crime laboratories, a NIST/ATF joint project entitled National Ballistics Imaging Comparison (NBIC) was initialized in 2008. The NBIC project aims to establish a National Traceability and Quality System for ballistics identifications in crime laboratories within the National Integrated Ballistics Information Network (NIBIN) of the U.S. NIST Standard Reference Material (SRM) 2460 bullets and 2461 cartridge cases are used as reference standards. 19 ballistics examiners from 13 U.S. crime laboratories participated in this project. They each performed 24 periodic image acquisitions and correlations of the SRM bullets and cartridge cases over the course of a year, but one examiner only participated in Phase 1 tests of SRM cartridge case. The correlation scores were collected by NIST for statistical analyses, from which control charts and control limits were developed for the proposed Quality System and for promoting future assessments and accreditations for firearm evidence in U.S. forensic laboratories in accordance with the ISO 17025 Standard.

SELECTION OF CITATIONS
SEARCH DETAIL
...